Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PUMPS, FUEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control

ResStock Measure Documentation: Dual Fuel Heat Pump

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Dual Fuel Heat Pump" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST

Design of a High-Pressure Fuel System for Use with Dimethyl Ether

The paper documents the modeling and experimental work on a common rail fuel injection system for Dimethyl Ether, a potential diesel substitute with a low carbon intensity signature. The DME fuel system is deployed on a light duty 2.2L compression ignition engine. The paper describes the injector optimization to shift to higher flows to account for the lower heating value and density of the DME when compared to diesel. The type of the injection system used for the DME application is an advanced rendering of the Common rail noted for a one-piece piston-needle injector construction and a solenoid driven spill valve featuring a pressure balanced poppet. A dedicated high-pressure fuel pump designed to pressurize DME is used. The design results in a fast acting open and close injection event, reduced leakage, with reduced cavitation in the fuel injector volume. Design parameters for system optimization included fill and spill orifices, needle lift, bias spring, and injector hole size. The design model provides good correlation of the instantaneous rates of injection with experiments across a wide range of pressure and injection timings. Proposed performance milestones for the design included similar DME injection duration to the diesel counterpart for same fuel energy injected into the cylinder to retain high engine cycle efficiency. Here, the dedicated DME design provided reduced hydraulic delays of 50%. Tests demonstrated sustained operation at pressures of 1000 bar, with capability to reach 1500bar. Durability tests showed no cavitation-deterioration over a 200-hour test cycle by means of spray imaging and hardware inspection.

De Ojeda, William [WM International Engineering, L

Sticking Coefficients of Fusion Reactor Impurities from Molecular Dynamics Simulations for the Design of Cryopumps

A cryopump can be utilized as an impurity removal component of a direct internal recirculation (DIR) system for the fusion fuel cycle. The DIR facilitates a low fuel inventory by continuously pumping unburnt fuel while removing impurities from the fusion exhaust stream. A cryopump can target multiple impurity species by maintaining a temperature lower than the gas triple-point temperature that promotes desublimation. The desublimation/condensation of gases in cryopumps can be characterized by the sticking coefficient, which is defined as the probability for a gas particle to stick to a (cryo-)surface upon collision. The sticking coefficient is one of the important design/operation parameters for cryopumps, and it depends on a variety of surface and gas properties. Here, in this study, molecular dynamics simulations were utilized to estimate the sticking coefficients of typical fusion gas impurity species N 2 , CO 2 , and CH 4 over a Cu surface for a range of gas temperatures and surface coverages. The molecular dynamics study showed that the sticking coefficients for gases decrease with an increase in gas temperature. The presence of a single full monolayer of condensate on the metallic surface showed an adverse effect on the sticking of gases; however the sticking improved with two full monolayers of condensate on the surface. The sticking of gases over the mixed condensate on a surface was more favorable than the condensate of the same species for N 2 and CH 4 , with an exception for CO 2 , which showed a decrease in sticking over the mixed condensate.

cryopump

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Rheology and engine performance of very low sulfur fuel oil blended with 10% fast pyrolysis and hydrothermal liquefaction oils in a 2-stroke crosshead engine

The performance and emissions for a downscaled single-cylinder 2-stroke crosshead engine were determined for a very low sulfur fuel oil (VLSFO) when blended with 10 wt.% fast pyrolysis (FP) or hydrothermal liquefaction (HTL) bio-intermediates. The FP and HTL oils were derived from biomass and were observed to contain lower molecular weight (MW) hydrocarbons than neat VLSFO (which was evaluated as a baseline comparison). The addition of either biofuel reduced the overall viscosity of the VLSFO. Aging tests at 50, 90, and 120°C showed that the dynamic viscosity of VLSFO increased with exposure time up to two weeks. Similar trends were observed for the FP and HTL blends, but a pronounced spike in viscosity occurred for these fuels during the early period of exposure. None of the viscosity increases exceeded the operational limits of fuel system pumps. Engine performance studies were conducted under low, medium and high load operational settings. The relative performance of the test fuels was highly dependent on operating condition. In general, the engine results for the three test fuels were similar, but modest improvements in brake thermal efficiency and brake specific fuel consumption were observed, which may be attributed to the heightened reactivity of low molecular weight fraction of the FP and HTL oils.

09 BIOMASS FUELS

Advected carbon younger than the sediment fuels microbial metabolism in a pumped deep aquifer

Ever deeper wells are drilled worldwide to pump potable groundwater. Recent studies argue that overpumping compresses clays and releases reactive dissolved organic carbon (DOC), which in turn drives a series of microbial reactions that affect groundwater potability including arsenic concentrations. Here, we use a novel method to measure the radiocarbon ages of microbial RNA to determine the source of reactive or metabolizable DOC and argue against the compression of clays as the sole source of carbon. We show that microbial RNA (5,230; 5,550; 6,250 yr; n = 3 wells), DOC (280-10,800 yr; n = 13), and methane (modern to 6,240 yr; n = 3), from an overpumped deep aquifer in Bangladesh are much younger than the overlying clay layers deposited during the Pleistocene over 12,000 years ago. Mass-balance indicates that at least half of the carbon incorporated into RNA has to come from reactive DOC or methane that is advected downward via vertical recharge. This metabolism of advected organic carbon could have implications for the quality of water pumped from deep aquifers.

Biological and medical sciences

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY

Methanol mixing−controlled compression ignition enabled via homogeneous charge compression ignition of dimethyl ether through catalytic decomposition of methanol

Methanol is a potentially attractive fuel for marine and off−road engines owing to its availability at bunkering and global distribution locations. Although methanol is well−distributed worldwide, its fuel chemistry and ignition properties make it poorly suited as a direct drop−in replacement for diesel fuel in compression−ignition engines. However, industrial processes are regularly used to convert methanol, via catalytic dehydration, to dimethyl ether (DME) over nonprecious metal catalysts. This chemical conversion can occur at relatively low pressures, temperatures, and catalyst space velocities, highlighting a potential opportunity to generate DME via onboard catalytic dehydration of methanol. DME’s fuel kinetic and ignition properties for compression ignition are much more favorable than those of methanol or even diesel fuel, but DME is more challenging than diesel fuel or methanol to pump, store, and deliver through conventional diesel fueling injection hardware. Thus, a potential opportunity exists to use the ignition and kinetic properties of DME, with the transportation and delivery advantages of methanol, in a methanol−fueled mixing−controlled compression−ignition engine. The present work explores performance, combustion behavior, and emissions reduction opportunities for methanol mixing−controlled combustion, enabled by a HCCI of DME that represents a small fraction of the total fuel energy that can be generated onboard via catalytic dehydration of methanol.

Splitter, Derek [ORNL] (ORCID:0000000174044047)

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

The impact of helium on plasma-driven hydrogen permeation and implications for direct internal recycling in the fusion fuel cycle

Abstract Metal foil pumps (MFPs) are the leading technology for direct internal recycling (DIR) of hydrogen isotopes from the plasma exhaust in future fusion plants. MFPs rely on the concept of superpermeation, where superthermal H atoms directly absorb into the metal foil, rapidly diffuse, and desorb downstream. To date, studies of superpermeation have predominantly employed either pure hydrogen or in some cases trace levels of impurities. The plasma exhaust is expected to contain just ∼1% helium, but in DIR the source gas would be enriched in helium as hydrogen isotopes are extracted. In this work, we explore the impact of helium on hydrogen superpermeation at low temperature (75 °C–200 °C) using Pd-based foils. To first order, the flux scaled linearly with the hydrogen mole fraction. Stable permeation was observed until the helium fraction reached ∼80%, where the flux began to decline slowly with time. In addition, short term (1–5 min) exposure to pure helium plasma significantly attenuated subsequent hydrogen plasma permeation, and the degree was more dramatic at elevated temperature. This attenuation was correlated with He retention in the foils, which was detected by time-of-flight secondary ion mass spectrometry at low levels (<0.1 at. %) and limited to the near surface (<10 nm). Similar trends were observed among all alloys (Pd, PdAg, PdCu), and the foils were restored to full performance with an Ar + sputter clean. The potential for helium plasma exposure to impact MFP performance under these conditions has not been previously reported, and these findings have significant implications to the design and implementation of practical DIR systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil

Computational Study of a Cryopump Design for Fusion Exhaust Gas Purification Using Direct Simulation Monte Carlo

Cryopump-based direct internal recycling (DIR) of fusion fuel is an attractive prospect because it provides pumping of helium ash from a reactor along with separation of helium and other impurities from the fuel. Previous studies have demonstrated a continuously regenerating cryopump, referred to as the Snail pump, that separates helium ash from fusion fuel for reactor-relevant flow rates. Here, in this study, a conceptual cryopump was designed as a proof-of-principle study to target other impurities, besides helium ash, from the fusion exhaust that would complement the Snail pump. The impurity-removal cryopump consists of four sets of chevron fins, two sets operating at 80 K and the other two at 30 K. A computational study using direct simulation Monte Carlo (DSMC) was performed with a gas mixture of 96.5% D2, 2.0% He, and 0.5% each of CO2, N2, and CH4. In this configuration, 80 K chevron fin sets are capable of capturing CO2 and 30 K sets capable of capturing CO2, N2, and CH4. The computational study showed that the cryopump is capable of reducing the impurity content by more than two orders of magnitude from the flow.

Adhikari, Nirajan [Oak Ridge National Laboratory (

Continued Testing and Modeling of the AirSquared All-Metal Tritium Scroll Pump

The implementation of fusion energy requires the processing of the deuterium-tritium mixture used to fuel the reaction. Many gas processing operations require either a gas-motive force or a pressure gradient across a system; both are achieved using vacuum pumps. However, because of the material challenges of working with tritium, specialized pumps are required that use only metal on wetted surfaces. This prevents tritium retention and degradation of materials such as oils and polymers and reduces the generation of tritiated waste. Typical gas handling systems for tritium operations involve metal bellows pumps, all-metal scroll pumps, and metal turbomolecular pumps, depending on the pressure requirements. With the industry standard Normetex Type 15 m 3 /h (typically referred to as the Normetex 15) pump no longer available, the fusion market requires viable alternatives. In this study, we test an American-made pump, the AirSquared V16H034A-C01, and compare its performance to the Normetex. A performance model of the AirSquared pump is also produced, which can be applied to general process models to generate an accurate description of pressures and flows through various unit operations.

08 HYDROGEN