The effect of pulse rise time on nanosecond switching in magnetic thin films
Pulse rise time effect on nanosecond magnetic thin film switching with flux reversal and stray field interaction
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Pulse rise time effect on nanosecond magnetic thin film switching with flux reversal and stray field interaction
Development and characteristics of electric circuitry for detecting electrical pulses rise time and amplitude
The quantitative optical characteristics of cloud to ground (CG) and intracloud (IC) lightning above clouds were studied. A data base of a number of pulse paramaters such as energy, rise times, pulse widths and pulse intervals was complied and categorized for first return strokes, subsequent strokes, the intracloud part of CG flashes and IC flashes. It is found that: (1) single stroke CG's are more readily distinguishable from IC flashes than multiple stroke CG's; (2) there is no significant difference between the energy of first and subsequent return stroke pulses; and (3) the pulse rise times and pulse widths are time broadened. Lightning activity in a mesoscale convective weather system (MCS) was examined. The CG flash rates average almost 50 per minute for 7 hours. It is shown that lightning above storms embedded within the MCS IC lightning activity can be much greater than CG activity at certain times in the MCS lifecycle.
Near-infrared optical measurements of about 1300 optical pulses produced by 79 lightning flashes were obtained by a NASA U-2 high-altitude airplane. Ninety percent of the flashes produced peak radiant energy densities of 4.7 microJ/sq m per sr or greater relative to the full field of view of the instrument. A median pulse rise time of 240 microsec and FWHM of 370 microsec are found, and these slow optical rise times and broad pulse widths are suggested to be due to multiple scattering within the cloud. The spectral characteristics in the near-infrared of the neutral emission lines noted above the clouds are shown to be similar to those found with ground-based measurements.
Simple circuit with high input and low output impedance generates a fast rise-time pulse synchronized with an input pulse of slower rise and fall times. Circuit requires no external power.
Heavy positive ions pulse counting by spiral-type continuous channel electron multipier, noting long pulse rise time composed of numerous after pulsing
A batch program written in FORTRAN IV which does D.C. and transient analysis of MOS circuits is presented. Circuits employing N-MOS transistors and/or P-MOS transistors in either a bulk technology or an SOS technology, or almost any combination of R-C elements may be analyzed. The program requires as input data the complete circuit topology, device parameters, process parameters, and control parameters. The user can specify initial node conditions and the input pulse format. For example, pulse rise time, fall time, width and time between succeeding pulses are all independently controllable. The program contains a sophisticated mathematical model that can accurately handle either NMOS, P-MOS, Bulk or SOS devices. Sensitivity to process changes is maintained by requiring such process parameters as threshold voltage and doping level as program inputs.
A Position Sensitive Transition-Edge Sensor (PoST) is a microcalorimeter device capable of one-dimensional imaging spectroscopy. The device consists of two Transition-Edge Sensors (TESs) connected to the ends of a long X-ray absorbing strip. The energy of a photon hitting the absorber and the position of the absorption event along the strip is measured from the response in the two sensors by analyzing the relative signal sizes, pulse rise times, and the sum of the pulses measured at each sensor, We report on the recent PoST effort at Goddard for applications to large field of view, high-energy- resolution, X-ray astrophysics.
The objective of this research is to investigate system level performance and design issues associated with magnetic flux compression devices for aerospace power generation and propulsion. The proposed concept incorporates the principles of magnetic flux compression for direct conversion of nuclear/chemical detonation energy into electrical power. Specifically a magnetic field is compressed between an expanding detonation driven diamagnetic plasma and a stator structure formed from a high temperature superconductor (HTSC). The expanding plasma cloud is entirely confined by the compressed magnetic field at the expense of internal kinetic energy. Electrical power is inductively extracted, and the detonation products are collimated and expelled through a magnetic nozzle. The long-term development of this highly integrated generator/propulsion system opens up revolutionary NASA Mission scenarios for future interplanetary and interstellar spacecraft. The unique features of this concept with respect to future space travel opportunities are as follows: ability to implement high energy density chemical detonations or ICF microfusion bursts as the impulsive diamagnetic plasma source; high power density system characteristics constrain the size, weight, and cost of the vehicle architecture; provides inductive storage pulse power with a very short pulse rise time; multimegajoule energy bursts/terawatt power bursts; compact pulse power driver for low-impedance dense plasma devices; utilization of low cost HTSC material and casting technology to increase magnetic flux conservation and inductive energy storage; improvement in chemical/nuclear-to-electric energy conversion efficiency and the ability to generate significant levels of thrust with very high specific impulse; potential for developing a small, lightweight, low cost, self-excited integrated propulsion and power system suitable for space stations, planetary bases, and interplanetary and interstellar space travel; potential for attaining specific impulses approaching 10 (exp 6) seconds, which would enable missions to the outer planets within ten years and missions at interstellar distances within fifty years.
During the initial phase of a lightning strike attachment on an aircraft, fast current pulses (rise time approximately 100 ns, I(sub max) approximately few kA) were measured, which can create equipment upsets or disturbances. This threat, made of repetitive pulses and usually called 'multiple bursts', can be reproduced at the equipment interfaces assuming that the transfer function of the structure was determined. The normalized waveform H (10 kA - 100 ns rise time) is the reference for one of these pulses. The importance of the coaxial return path termination for the injection of the wave H is emphasized. According to the constitutive materials of the test bed, and the adaptation of the line, the natural oscillations of the structure and the internal coupling mechanisms can be modified. As a conclusion, various test configurations in relation with the nature of the test bed and the characteristics of the generator are detailed, for a more accurate ground simulation of the attachment phase.
Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.
Semiconductor photoconductive switches generate electrical pulses containing submillimeter-wavelength carrier signals (frequency between 300 and 3,000 GHz) and harmonics thereof when illuminated with short-rise-time pulses from lasers. Device of this type used as local oscilator in heterodyne submillimeter-wave receiver. Electrical output of device coupled via transmission line, waveguide, or antenna to mixer circuitry of receiver. Phase delays between optically activated semiconductor switches determine output carrier frequencies. N electrical pulses generated by each laser pulse. Thus, fundamental output frequency is N times laser-pulse-repetition rate.
Electrical pulse generator uses power transistors and silicon controlled rectifiers for producing a high current pulse having fast rise and fall times. At quiescent conditions, the standby power consumption of the circuit is equal to zero.
The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.
This presentation discusses the use of magnetic flux compression for space flight applications as a propulsion and other power applications. The qualities of this technology that make it suitable for spaceflight propulsion and power, are that it has high power density, it can give multimegawatt energy bursts, and terawatt power bursts, it can produce the pulse power for low impedance dense plasma devices (e.g., pulse fusion drivers), and it can produce direct thrust. The issues of a metal vs plasma armature are discussed, and the requirements for high energy output, and fast pulse rise time requires a high speed armature. The plasma armature enables repetitive firing capabilities. The issues concerning the high temperature superconductor stator are also discussed. The concept of the radial mode pulse power generator is described. The proposed research strategy combines the use of computational modeling (i.e., magnetohydrodynamic computations, and finite element modeling) and laboratory experiments to create a demonstration device.
The consequence of frequency domain multiple access channelization in a satellite communications system is that the ground- and space-based components often are required to operate in a linear region to prevent the generation of distortion signals. Components of a time division multiple access (TDMA) satellite system, such as a traveling-wave tube (TWT), can operate in the highest output power state because the channelization technique is relatively insensitive to the distortions resulting from saturated operation. A 30 GHz TWT was tested to determine the suitability of such a device in a TDMA system. Testing was focused on the ability of the TWT's output signal to rise up to full power at the leading edge of TDMA bursts, simulated by a pulse train. A peak power meter was used to display and measure the pulsed signal waveform. Measurements on the TWT output pulse rise time indicate that the TWT lengthened the rise time by 10 to 20 ns. Imposing modulator turn on timing that precedes the data burst by the TWT rise time is a logical approach to coordination of the two subsystem specification.
Pulsed or steady outputs up to 20 kV produced by commercial components. Circuit produces adjustable high-voltage output in response to low-voltage input. Output voltage changes approximately linearly up to 20 kilovolts as input voltage varied from 0 to 5 volts. Output steady, or sine wave varied at rates up to 100 pulses per second. Output current about 100 microamperes. Reduction in output-filter capacitance confers additional benefit by reducing pulse rise time.
Electric circuit for producing high current pulse having fast rise and fall time