Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PULSE RISE TIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A hybrid model for simulation of secondary electron emission in plasma immersion ion implantation under different pulse rise time

A hybrid fluid Particle in Cell–Monte Carlo Collision (PiC–MCC) model is presented to study the effect of secondary electron emission on the plasma immersion ion implantation process under different pulse rise time. The model describes the temporal evolution of various parameters of plasma such as ion density, ion velocity, secondary electron density, and secondary electron current for different rise times. A 3D–3 V PiC–MCC model is developed to simulate the secondary electrons which are emitted from the sample surface while the plasma ions and electrons are treated using a 1D fluid model. The simulation results indicate that the secondary electron density and secondary electron current increase as the rise time decreases. The main differences between the results for different rise times are found during the initial phase of the pulse. The results are explained through studying the fundamental parameters of plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed oscillation of a diode-pumped passively Q-switched Ca{sub 3}Ga{sub 2}Ge{sub 3}O{sub 12}:Nd{sup 3+} laser

Pulsed oscillation of a diode-pumped passively Q-switched Nd{sup 3+}:Ca{sub 3}Ga{sub 2}Ge{sub 3}O{sub 12} (Nd:CGGG) solid-state laser is studied. For the absorbed pump power of 0.8 W, the pulse energy was 3.5 {mu}J and the pulse rise time, duration and decay time were 6, 11 and 13 ns, respectively. The pulse repetition rate varied from 3 to 13 kHz when the absorbed pump power was changed from 0.45 to 1 W. It is shown that all the temporal parameters of the generated pulse decrease with increasing the absorbed pump power. The sensitivities of these parameters and the pulse repetition rate to changes in the absorbed pump power and the laser resonator length are measured. The results of the research are compared with the corresponding results for the pulsed Nd:YAG laser operating under the same conditions. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of Off-Line-of-Sight Propagation in Geomagnetic EMP Formation

The author’s synchrotron radiation based 3D geomagnetic EMP code MACSYNC has been used to explore the impact on pulse rise time and air conductivity of EMP propagation paths to the observer that are located off the direct line-of-sight (LOS) between gamma source and observer. This geometry is always present because, for an isotropic source, most the gammas are emitted at an angle with respect to the LOS. Computations for a 1 kt near-surface burst observed from space yield two principal findings: 1. The rise time is generated by the combined actions of a) electron spreading along the LOS due to the Compton electron emission angular distribution folded with electron multiple scattering effects, and b) radiation arrival time spreading due to length differences for different off-LOS propagation paths. The pulse rise time does not depend on the rise time of the conductivity. The conductivity rise time determines the pulse amplitude. 2. One-dimensional legacy EMP codes are inherently incapable of producing the correct pulse shape because they cannot treat the dependence of the conductivity on two dimensions, i.e. the radius from the source and the angle of the propagation path with the LOS. This divergence from one-dimensionality begins at a small fraction of a nanosecond for a sea-level burst. This effect will also be present in high-altitude bursts, however, determination of its onset time and magnitude requires high-altitude computations which have not yet been done.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Research and development of RHIC injection kicker upgrade with nano second FID pulse generator

Our recent effort to test a 50 kV, 1 kA, 50 ns pulse width, 10 ns pulse rise time FID pulse generator with a 250 ft transmission cable, resistive load, and existing RHIC injection kicker magnet has produced unparalleled results. This is the very first attempt to drive a high strength fast kicker magnet with a nano second high pulsed power (50 MVA) generator for large accelerator and colliders. The technology is impressive. We report here the result and future plan of RHIC Injection kicker upgrade.

43 PARTICLE ACCELERATORS↗

Lightning Observations above and below clouds

The quantitative optical characteristics of cloud to ground (CG) and intracloud (IC) lightning above clouds were studied. A data base of a number of pulse paramaters such as energy, rise times, pulse widths and pulse intervals was complied and categorized for first return strokes, subsequent strokes, the intracloud part of CG flashes and IC flashes. It is found that: (1) single stroke CG's are more readily distinguishable from IC flashes than multiple stroke CG's; (2) there is no significant difference between the energy of first and subsequent return stroke pulses; and (3) the pulse rise times and pulse widths are time broadened. Lightning activity in a mesoscale convective weather system (MCS) was examined. The CG flash rates average almost 50 per minute for 7 hours. It is shown that lightning above storms embedded within the MCS IC lightning activity can be much greater than CG activity at certain times in the MCS lifecycle.

Goodman, S. J.↗

Lasing from the domain of collision of ionisation waves produced due to electric field concentration at electrodes with a small radius of curvature

The characteristics of UV lasing in nitrogen and of diffusive discharge produced without an additional ionisation source were experimentally investigated in a nonuniform electric field formed by electrodes with different profiles. High-voltage nanosecond pulses were applied to the blade- and cylinder-shaped electrodes. It was determined that the gap breakdown at elevated pressure was caused by diffusive jets which propagate from the electrodes with a small radius of curvature. The electric field increased in the intersection of counter-propagating jets, with the effect that the threshold of lasing in the C{sup 3}{Pi}{sub u} - B{sup 3}{Pi}{sub g} ({lambda} = 337.1 nm) molecular nitrogen band was attained for low average electric fields (below 60 V cm{sup -1} Torr{sup -1}) and at pressures of 760 Torr and above. With lowering the pressure from 760 to 20 Torr, the voltage of gap breakdown in the nonuniform electric field was observed to increase for a voltage pulse rise time of {approx}300 ps and to decrease for a pulse rise time of {approx}2 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of fusion fuel conditions and instability development in shocklessly compressed MagLIF implosion simulations

Magnetized liner inertial fusion (MagLIF) implosions on the Z accelerator have almost exclusively been driven by ∼100-ns rise time current pulses. The rise time is selected to be as short as achievable on Z partially to minimize the time during which deleterious implosion instabilities can develop. Modifying the shape of the current pulse could provide benefits for MagLIF, including more efficient compression of the fusion fuel and the magnetic flux inside the liner cavity. Quasi-isentropic compression of the liner prevents formation of shocks in the liner material and reduces the amount of entropy generation within the liner. This allows for more final compression of the liner and fuel assembly. We present results from one-dimensional (1D) radiation-magnetohydrodynamic (rad-MHD) simulations comparing thermonuclear fuel conditions in MagLIF implosions driven with two different current pulses: a ∼100-ns rise time, ∼21.5 MA peak current “short pulse” and a ∼200-ns rise time, ∼21.5 MA peak current “shockless” pulse. We also quantify and compare the instability development in three-dimensional (3D) MHD implosion simulations driven by these two different pulse shapes. Our 1D simulations indicate that the shocklessly compressed MagLIF implosion performs better than the short pulse driven implosion with a >50% higher thermonuclear neutron yield, and 3D simulations indicate comparable implosion instability development, suggesting that pulse shaping could enable improvements to MagLIF performance on Z without compromising implosion stability.

Shipley, G. A. (ORCID:0000000205364001)↗

Microstructural evolution during dynamic deformation of cubic metals: copper

Shockwave shape can influence dynamic damage evolution. Features such as rise time, pulse duration, peak shock pressure, pull back, and release rate are influenced as wave shape changes. However, their individual influence on dynamic damage evolution is not well understood. Specifically, changing from a square to triangular or Taylor wave loading profile can alter the release kinetics from peak shock pressure and the volume of material sampled during release. This creates a spatial influence. In high purity metals, because damage is often linked to boundaries within the microstructure (grain or twin), changing the volume of material sampled during release, can have a drastic influence on dynamic damage evolution as the number of boundaries or defects sampled is altered. In this study, model-driven dynamic experiments have been conducted on eu with four different grain sizes to examine, for a given shockwave shape, how the spatial effect of boundary distribution influences dynamic damage evolution. Both two and three dimensional damage characterization techniques have been utilized. This study shows the critical influence of spatial effects, in this case boundary density, on dynamic damage evolution. As the boundary density decreases, the damage evolution transitions from nucleation controlled to growth controlled. It also shows that specific boundaries, those with high Schmid factor orientations on either side, maybe a necessary condition for void formation.

36 MATERIALS SCIENCE↗

MO-F-CAMPUS-J-01: Acoustic Range Verification of Proton Beams: Simulation of Heterogeneity and Clinical Proton Pulses

Purpose: Through simulation, to assess acoustic-based range verification of proton beams (protoacoustics) under clinical conditions. Methods: Pressure waves generated by the energy deposition of a 150 MeV, 8 mm FWHM pulsed pencil proton beam were numerically simulated through two Methods: 1) For a homogeneous water medium, an analytical wave-equation solution was used to calculate the time-dependent pressure measured at detector points surrounding the proton Bragg peak. 2) For heterogeneity studies, a CT tissue image was used to calculate the proton dose deposition and define the acoustic properties of the voxels through which numerical pressure wave propagation was simulated with the k-Wave matlab toolbox. The simulations were used to assess the dependence of the acoustic amplitude and range-verification accuracy on proton pulse rise time and tissue heterogeneity. Results: As the proton pulse rise time is increased from 1 to 40 µs, the amplitude of the expected acoustic emission decreases (a 60% drop distal to the Bragg peak), the central frequency of the expected signal decreases (from 45 to 6 kHz), and the accuracy of the range-verification decreases (from <1 mm to 16 mm at 5 cm distal to the Bragg peak). For a 300 nA pulse, the expected pressure range is on the order of 0.1 Pa, which is observable with commercial detectors. For the heterogeneous medium, our test case shows that pressure waves emitted by an anterior pencil beam directed into the abdomen and detected posteriorly can determine the Bragg peak range to an accuracy of <2mm for a 1 µs proton pulse. Conclusion: For proton pulses with fast rise-times, protoacoustics is a promising potential method for monitoring penetration depth through heterogeneous tissue. The loss of range-verification accuracy with increasing rise-times, however, suggests the need for comparisons to modeling to improve accuracy for slower cyclotron proton sources.

07 ISOTOPE AND RADIATION SOURCES↗

Bipolar high-repetition-rate high-voltage nanosecond pulser

The pulser designed is mainly used for producing corona plasma in waste water treatment system. Also its application in study of dielectric electrical properties will be discussed. The pulser consists of a variable dc power source for high-voltage supply, two graded capacitors for energy storage, and the rotating spark gap switch. The key part is the multielectrode rotating spark gap switch (MER-SGS), which can ensure wider range modulation of pulse repetition rate, longer pulse width, shorter pulse rise time, remarkable electrical field distortion, and greatly favors recovery of the gap insulation strength, insulation design, the life of the switch, etc. The voltage of the output pulses switched by the MER-SGS is in the order of 3-50 kV with pulse rise time of less than 10 ns and pulse repetition rate of 1-3 kHz. An energy of 1.25-125 J per pulse and an average power of up to 10-50 kW are attainable. The highest pulse repetition rate is determined by the driver motor revolution and the electrode number of MER-SGS. Even higher voltage and energy can be switched by adjusting the gas pressure or employing N{sub 2} as the insulation gas or enlarging the size of MER-SGS to guarantee enough insulation level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on nanosecond pulsed atmospheric pressure discharge with particle-in-cell Monte Carlo collision simulation

Nanosecond pulsed atmospheric pressure discharge becomes an active research topic because of its promising prospect of applications in many areas. To understand its dynamics, the discharge process was studied by one-dimensional implicit particle-in-cell Monte Carlo collision (PIC-MCC) simulation coupled with a particle renormalization algorithm, in which multiple electron Monte Carlo collisions per step were considered to improve the computation efficiency. In the simulation, the effects of discharge conditions such as plateau voltage, pulse rise time, and initial charged particle density were investigated. It is found that the plateau voltage in the pulse waveform is a major factor controlling the final charged particle density in the plasma bulk, and the built-up time and steady thickness of cathode sheath are proportional to the pulse rise time, whereas reversely proportional to the initial charged particle density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi}{approx_equal}10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle in cell simulation of peaking switch for breakdown evaluation

Marx generator connected to peaking capacitor and peaking switch can generate Ultra-Wideband (UWB) radiation. A new peaking switch is designed for converting the existing nanosecond Marx generator to a UWB source. The paper explains the particle in cell (PIC) simulation for this peaking switch, using MAGIC 3D software. This peaking switch electrode is made up of copper tungsten material and is fixed inside the hermitically sealed derlin material. The switch can withstand a gas pressure up to 13.5 kg/cm{sup 2}. The lower electrode of the switch is connected to the last stage of the Marx generator. Initially Marx generator (without peaking stage) in air; gives the output pulse with peak amplitude of 113.75 kV and pulse rise time of 25 ns. Thus, we design a new peaking switch to improve the rise time of output pulse and to pressurize this peaking switch separately (i.e. Marx and peaking switch is at different pressure). The PIC simulation gives the particle charge density, current density, E counter plot, emitted electron current, and particle energy along the axis of gap between electrodes. The charge injection and electric field dependence on ionic dissociation phenomenon are briefly analyzed using this simulation. The model is simulated with different gases (N{sub 2}, H{sub 2}, and Air) under different pressure (2 kg/cm{sup 2}, 5 kg/cm{sup 2}, 10 kg/cm{sup 2}). (author)

43 PARTICLE ACCELERATORS↗

Optical observations of lightning from a high-altitude airplane

Near-infrared optical measurements of about 1300 optical pulses produced by 79 lightning flashes were obtained by a NASA U-2 high-altitude airplane. Ninety percent of the flashes produced peak radiant energy densities of 4.7 microJ/sq m per sr or greater relative to the full field of view of the instrument. A median pulse rise time of 240 microsec and FWHM of 370 microsec are found, and these slow optical rise times and broad pulse widths are suggested to be due to multiple scattering within the cloud. The spectral characteristics in the near-infrared of the neutral emission lines noted above the clouds are shown to be similar to those found with ground-based measurements.

Christian, H. J.↗

Rise time of voltage pulses in NbN superconducting single photon detectors

We have found experimentally that the rise time of voltage pulse in NbN superconducting single photon detectors increases nonlinearly with increasing the length of the detector L. The effect is connected with dependence of resistance of the detector R{sub n}, which appears after photon absorption, on its kinetic inductance L{sub k} and, hence, on the length of the detector. This conclusion is confirmed by our calculations in the framework of two temperature model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗