Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PULSE HEIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estimating Scaled Cloud Height in Pulse Jet Mixed Vessels

To suspend and mix radioactive slurries without pumps or impellers, the performance of pulsed jet mixed vessels has been investigated. The slurry in the pulse tubes is expelled impinging upon the vessel floor and lifting solids to a “cloud height” in a cyclic process. Experiments measuring cloud height for a variety of waste simulants have been conducted for vessel configurations that varied vessel diameter, fill height and pulse tube number, volume, and nozzle diameter. The elevation to which suspended particles rise is termed the cloud height and derives from a balance between the fluid forces of the jet and the gravitational forces acting on the particle ensemble. Here we use scaling to estimate the cloud height based on conservation of mass and momentum and jet similarity. We find that the cloud height varies with the nozzle exit velocity to the 2/3 power in agreement with observations.

cloud height, effective cleaning radius, effective

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Performance assessment after long-term irradiation of ATLAS Micromegas detectors using 120 GeV muons at the Gamma Irradiation Facility at CERN

The ATLAS muon spectrometer will face an increased particle rate as a result of the increased instantaneous luminosity expected during the High-Luminosity LHC (HL-LHC) upgrade. The HL-LHC will provide a luminosity of $\mathscr{L}$ = 7.5 × 10 34 cm −2 s −1 and 3000 fb −1 of integrated luminosity in 10 years, about 9 times more data of the ones so far collected by the ATLAS experiment. Micromegas chambers are used in the New Small Wheel(s), the first forward muon spectrometer station, to provide tracking and triggering at the intense particle rates expected. The detectors are operated with a ternary gas mixture composed of Ar + 5%CO 2 + 2%iC 4 H 10 , providing good high voltage stability and a large pulse height, important for inclined track reconstruction of particles crossing the detector. To ensure the long-term stable operation of the detector during the whole HL-LHC period, and due to the hydrocarbon content in the mixture, an extensive aging campaign has been ongoing since 2021 at the CERN Gamma Irradiation Facility, where spare production chambers are long-term exposed to a 14 TBq 137 Cs 𝛾-source, accumulating so far, a charge equivalent to five years of HL-LHC operations under the highest expected background rate. This paper describes the results of the Micromegas chamber performance studies after two years of gamma irradiation and using the SPS/H4 120 GeV muon beams at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ

Experimental investigation of longitudinal scraping of H- bunches via photo-detachment

Longitudinal emittance growth is a significant challenge in RF linacs, especially for poorly bunched beams. This stems from particles occupying outer synchrotron oscillation orbits in the LBET, causing unwanted bunch-bunch interactions and degraded beam quality. To address this, we proposed using temporally spaced laser pulses to selectively photo-detach electrons from the longitudinal head and tail regions of H- ion bunches. This approach aims to reduce particle density in extreme orbits, enhancing beam uniformity and limiting emittance growth. Our experiments employed Fermilab's 'LaserNotcher' system at the font end of the linac, delivering 1.6 MW peak power with sub-nanosecond precision. By neutralizing the first and last half-nanosecond of several H- bunches, we measured their propagation injection into the booster. Measurements of pulse width, average height, and temporal spacing over booster cycles were compared between the scraped and unscraped bunches. Statistical analysis evaluated the results’ significance, highlighting the feasibility of laser-based scraping for future linac designs to achieve higher beam energies with improved emittance control.

Landon, Parker [Boston U.]

Experimental investigation of longitudinal scraping of $H-$ bunches via photo-detachment

Longitudinal emittance growth is a significant challenge in RF linacs, especially for poorly bunched beams. This stems from particles occupying outer synchrotron oscillation orbits in the LBET, causing unwanted bunch-bunch interactions and degraded beam quality. To address this, we proposed using temporally spaced laser pulses to selectively photo-detach electrons from the longitudinal head and tail regions of H- ion bunches. This approach aims to reduce particle density in extreme orbits, enhancing beam uniformity and limiting emittance growth. Our experiments employed Fermilab's 'LaserNotcher' system at the font end of the linac, delivering 1.6 MW peak power with sub-nanosecond precision. By neutralizing the first and last half-nanosecond of several H- bunches, we measured their propagation injection into the booster. Measurements of pulse width, average height, and temporal spacing over booster cycles were compared between the scraped and unscraped bunches. Statistical analysis evaluated the results’ significance, highlighting the feasibility of laser-based scraping for future linac designs to achieve higher beam energies with improved emittance control.

Landon, P. [Boston U.; Fermilab]

Near-Complete Sampling of Forest Structure from High-Density Drone Lidar Demonstrated by Ray Tracing

Drone lidar has the potential to provide detailed measurements of vertical forest structure throughout large areas, but a systematic evaluation of unsampled forest structure in comparison to independent reference data has not been performed. Here, we used ray tracing on a high-resolution voxel grid to quantify sampling variation in a temperate mountain forest in the southwest Czech Republic. We decoupled the impact of pulse density and scan-angle range on the likelihood of generating a return using spatially and temporally coincident TLS data. We show three ways that a return can fail to be generated in the presence of vegetation: first, voxels could be searched without producing a return, even when vegetation is present; second, voxels could be shadowed (occluded) by other material in the beam path, preventing a pulse from searching a given voxel; and third, some voxels were unsearched because no pulse was fired in that direction. We found that all three types existed, and that the proportion of each of them varied with pulse density and scan-angle range throughout the canopy height profile. Across the entire data set, 98.1% of voxels known to contain vegetation from a combination of coincident drone lidar and TLS data were searched by high-density drone lidar, and 81.8% of voxels that were occupied by vegetation generated at least one return. By decoupling the impacts of pulse density and scan angle range, we found that sampling completeness was more sensitive to pulse density than to scan-angle range. There are important differences in the causes of sampling variation that change with pulse density, scan-angle range, and canopy height. Our findings demonstrate the value of ray tracing to quantifying sampling completeness in drone lidar.

47 OTHER INSTRUMENTATION

Quantification and assessment of the atmospheric boundary layer height measured during the AWAKEN experiment by a scanning LiDAR

The atmospheric boundary layer (ABL) height plays a key role in many atmospheric processes as one of the dominant flow length scales. However, a systematic quantification of the ABL height over the entire range of scales (i.e., with periods ranging from one minute to one year) is still lacking in literature. In this work, the ABL height is quantified based on high-resolution measurements collected by a scanning pulsed Doppler LiDAR during the recent American WAKE experimeNt (AWAKEN) campaign. The high availability of ABL height estimates (≈2200 collected over one year and each of them based on 10-min averaged statistics) allows to robustly assess five different ABL height models, i.e., one for convective thermal conditions and four for stable conditions. Thermal condition is quantified by a stability parameter spanning three orders of magnitude and probed by near-ground 3D sonic anemometry. The free-atmosphere stability, quantified by the Brunt–Väisälä frequency, is both calculated from simultaneous radiosonde measurements and obtained from the best fit of two of the chosen ABL height models. Good agreement is found between the data and three of the chosen models, quantified by mean absolute errors on the ABL height between 281 and 585 m. Furthermore, the seasonal variability of the convective ABL height model parameters (−15% to +23% with respect to the year baseline) agrees with the variability of buoyancy-generated turbulence caused by the variation in solar radiation throughout the year.

17 WIND ENERGY

Activity Convergence between Continuous- and Pulsed-Deposition NiFe Hydroxide Anodes in Liquid Alkaline Electrolyzers

Improving the activity of anodes for the alkaline oxygen evolution reaction (OER) is of interest because of the importance of the reaction in electrochemical technology. There is an abundance of studies which confirm that NiFe hydroxide, often prepared by electrodeposition, is the most active catalyst for the alkaline OER. This relatively high level of confidence in the optimal OER catalyst chemistry suggests that exploration of methods which improve on features besides the chemistry of the films, such as their microstructure, could access new heights of activity. In this study, the possible benefits of pulsed current deposition relative to the conventional continuous current approach to the deposition of NiFe hydroxides were investigated. Pulsed deposition densified the film surfaces by preventing metal ion depletion at the electrode surface during film formation. The Fe content, redox reversibility, and OER activity were higher for the pulsed deposition films relative to their continuous deposition counterparts. Though pulsed deposition imparted a higher OER performance of the films compared to continuous deposition at the three-electrode level, this improved performance was not retained during electrolyzer operation. Rather, a convergence of the cell performance is seen irrespective of the deposition approach. This phenomenon was attributed to the way electrolyzer conditionsrelatively high temperature, base concentration, and current densitycan drive alternate mechanisms for observed performance.

08 HYDROGEN

Scanning tunneling microscope tip-induced formation of Bi bilayers on Bi 2 Te 3

We report the formation of Bi(111) bilayer islands and crater structures on Bi 2 Te 3 (111) surfaces induced by voltage pulses from a scanning tunneling microscope tip. Pulses above a threshold voltage (+3 V) produce craters ∼0.5μm in diameter, similar to the size of the tip. Redeposited material self-assembles into a network of atomically ordered islands with a lattice constant identical to the underlying Bi2Te3 surface. The island size monotonically decreases over several micrometers from the pulse site, until the pristine Bi 2 Te 3 surface is recovered. We assign these islands to Bi bilayer based on atomic resolution images, analysis of step heights, and tunneling spectroscopy. Here, the dependence of bilayer formation on bias polarity and the evidence for defect diffusion together suggest a mechanism driven by the interplay of field evaporation and tunneling-current-induced Joule heating.

Bi bilayer