Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Quantifying agricultural productive use of energy load in Sub-Saharan Africa and its impact on microgrid configurations and costs

The use of advanced energy technologies for agricultural purposes—such as irrigation, refrigeration, crop processing, and egg incubation—has the potential to increase crop yield, reduce vulnerability to changing precipitation patterns, increase shelf life, strengthen income and employment opportunities in rural areas, and reduce emissions by displacing fossil fuel-based technologies. These productive uses of energy (PUE) in remote areas could potentially be powered by microgrids that additionally serve otherwise unelectrified communities, most of which are located in rural Sub-Saharan Africa. Here, in this paper, we use high-resolution geospatial data to estimate the end-use electricity demand for a range of agricultural PUE across Sub-Saharan Africa, and we share these data in an open-access mapping tool. Next, we use REopt®, a techno-economic optimization model of energy systems, to determine the cost and system sizing implications of incorporating agricultural PUE into microgrid designs in Kenya and Zambia. We estimate the upper bound of agricultural PUE demand for irrigation, milling, shelling, refrigeration, and egg incubation across Sub-Saharan to be 16.8 TWh/yr. We find that incorporating local agricultural PUE into microgrid system designs increases the required system sizing while having minimal impact on the levelized cost of energy of these systems. Our analysis is the first to demonstrate the PUE potential in the agricultural sector at a 10x10-kilometer resolution across Sub-Saharan Africa and to show, at scale, how site-specific PUE can impact the cost and sizing of microgrids that are otherwise deployed to serve local household and community load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

Empowering Rural Electrification in Honduras: An Integrated Assessment of PV/BESS and Productive Uses of Electricity in Gracias a Dios

Honduras faces significant challenges in its energy sector, particularly in rural areas where access to reliable and affordable electricity remains limited. The flagship rural electrification initiative for Honduras Secretary of Energy (SEN) is the Politica de Acceso Universal a la Electricidad (PAUEH - Universal Electricity Access Policy), a key solution for addressing this energy poverty is the deployment of more than 1700 distributed solar and hybrid mini-grid solutions. In late 2023 as a first step towards supporting SEN's electrification efforts, the National Renewable Energy Laboratory (NREL) developed a literature review of SEN electrification policy documents and conducted a series of technical capacity-building workshops with SEN and other energy sector stakeholders in Honduras focused on using NREL's open-source REopt tool to conduct techno-economic assessments and develop least-cost optimizations for potential solar + storage mini-grid systems. Building on some initial capacity building on mini-grid modeling, the National Renewable Energy Laboratory (NREL) worked with SEN to develop a detailed techno-economic assessment for electrifying two schools, a healthcare clinic, and a hospital in a hypothetical community within the department of Gracias a Dios. The analysis also evaluates the business case for cold storage productive use of energy (PUE) applications for the fisheries value chain and how the incorporation of these PUE loads potentially impacts both the viability of the PV+BESS solutions as well as local economic development. By assessing the potential for deployment of integrated PV/BESS systems to both support critical community services like education and healthcare, as well as potential for downstream enterprise and economic development, this analysis represents a first step that can help to inform specific strategies for development of pilot PV+BESS projects aligned with national priorities and sector level planning under PAUEH.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fortalecimiento de la Electrificación Rural en Honduras: Una Evaluación Integrada de PV+BESS y Usos Productivos de la Electricidad en Gracias a Dios, Honduras [Empowering Rural Electrification in Honduras: An Integrated Assessment of PV/BESS and Productive Uses of Electricity in Gracias a Dios] (Spanish Translation)

Honduras faces significant challenges in its energy sector, particularly in rural areas where access to reliable and affordable electricity remains limited. The flagship rural electrification initiative for Honduras Secretary of Energy (SEN) is the Politica de Acceso Universal a la Electricidad (PAUEH - Universal Electricity Access Policy), a key solution for addressing this energy poverty is the deployment of more than 1700 distributed solar and hybrid mini-grid solutions. In late 2023 as a first step towards supporting SEN's electrification efforts, the National Renewable Energy Laboratory (NREL) developed a literature review of SEN electrification policy documents and conducted a series of technical capacity-building workshops with SEN and other energy sector stakeholders in Honduras focused on using NREL's open-source REopt tool to conduct techno-economic assessments and develop least-cost optimizations for potential solar + storage mini-grid systems. Building on some initial capacity building on mini-grid modeling, the National Renewable Energy Laboratory (NREL) worked with SEN to develop a detailed techno-economic assessment for electrifying two schools, a healthcare clinic, and a hospital in a hypothetical community within the department of Gracias a Dios. The analysis also evaluates the business case for cold storage productive use of energy (PUE) applications for the fisheries value chain and how the incorporation of these PUE loads potentially impacts both the viability of the PV+BESS solutions as well as local economic development. By assessing the potential for deployment of integrated PV/BESS systems to both support critical community services like education and healthcare, as well as potential for downstream enterprise and economic development, this analysis represents a first step that can help to inform specific strategies for development of pilot PV+BESS projects aligned with national priorities and sector level planning under PAUEH. This is the Spanish translation of NREL/TP-7A40-90865.

14 SOLAR ENERGY↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Genomics and physiology of Catenibacillus, human gut bacteria capable of polyphenol C-deglycosylation and flavonoid degradation

The genusCatenibacillus(familyLachnospiraceae, phylumBacillota) includes only one cultivated species so far,Catenibacillus scindens,isolated from human faeces and capable of deglycosylating dietary polyphenols and degrading flavonoid aglycones. Another human intestinalCatenibacillusstrain not taxonomically resolved at that time was recently genome-sequenced. We analysed the genome of this novel isolate, designatedCatenibacillus decagia, and showed its ability to deglycosylateC-coupled flavone and xanthone glucosides andO-coupled flavonoid glycosides. Most of the resulting aglycones were further degraded to the corresponding phenolic acids. Including the recently sequenced genome ofC. scindensand ten faecal metagenome-assembled genomes assigned to the genusCatenibacillus, we performed a comparative genome analysis and searched for genes encoding potentialC-glycosidases and other polyphenol-converting enzymes. According to genome data and physiological characterization, the core metabolism ofCatenibacillusstrains is based on a fermentative lifestyle with butyrate production and hydrogen evolution. BothC. scindensandC. decagiaencode a flavonoidO-glycosidase, a flavone reductase, a flavanone/flavanonol-cleaving reductase and a phloretin hydrolase. Several gene clusters encode enzymes similar to those of the flavonoidC-deglycosylation system ofDoreastrain PUE (DgpBC), while separately located genes encode putative polyphenol-glucoside oxidases (DgpA) required forC-deglycosylation. The diversity ofdgpAanddgpBCgene clusters might explain the broadC-glycoside substrate spectrum ofC. scindensandC. decagia. The otherCatenibacillusgenomes encode only a few potential flavonoid-converting enzymes. Our results indicate that severalCatenibacillusspecies are well-equipped to deglycosylate and degrade dietary plant polyphenols and might inhabit a corresponding, specific niche in the gut.

Genetics & Heredity↗

Integrating Energy-Efficient Computing with Computational Research to Accelerate Energy Technology

NREL's computational sciences center hosts the largest high performance computing (HPC) capabilities dedicated to energy research while functioning as a living laboratory for energy-efficient computing. NREL's HPC capabilities support the research needs of the Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). In ten years of operation, HPC use in EERE-sponsored research has grown by a factor of 30, including work in electricity generation, energy efficiency, transportation, and energy system modeling. This paper analyzes this research portfolio, providing examples of individual use cases. The paper documents NREL's history of operating one of the world's most energy-efficient data centers while examining pathways to reduce economic and environmental impact beyond reduction of Power Usage Efficiency (PUE). This paper concludes by examining the unique opportunities created for accelerating improvements in data center efficiency created by combining an HPC system dedicated to energy research and a research program in energy-efficient computing.

97 MATHEMATICS AND COMPUTING↗

Expanding a Supercomputer Facility Using Modular Data Center Technology

With the expansion of high-end computing resources needed to support NASA's increasing demands for physics-based simulations, the facility housing Pleiades-the agency's largest supercomputer-recently reached its power and cooling capacity. In response, the NASA Advanced Supercomputing Division at Ames Research Center undertook a prototype project that resulted in a new facility based on modular data center technology. The facility, a ~1000 square-foot module on a concrete pad with room for 16-18 compute racks, was completed in fall 2016 and an SGI computer system, named Electra, was deployed there in early 2017. Cooling is performed via an evaporative system built into the module, and preliminary experience shows a Power Usage Effectiveness (PUE) of ~1.03. Electra achieved over a petaflop on the LINPACK benchmark, sufficient to rank number 96 on the November 2016 TOP500 list. The system consists of 1,152 InfiniBand-connected Intel Xeon Broadwell-based nodes. Its users access their files on a facility wide file system shared by all compute assets via Mellanox MetroX InfiniBand extenders, which connect the Electra fabric to Lustre routers InfiniBand fabric over fiber-optic links about 300 meters long. The prototype has exceeded expectations and is serving as a blueprint for future expansions.*†

Facility↗

Electra: A Modular-Based Expansion of NASA's Supercomputing Capability

NASA has increasingly relied on high-performance computing (HPC) re- sources for computational modeling, simulation, and data analysis to meet the science and engineering goals of its missions in space exploration, aeronautics, and Earth and space science. The NASA Advanced Supercomputing (NAS) Division at Ames Research Center in Silicon Valley, Calif., hosts NASA’s premier supercomputing resources, integral to achieving and enhancing the success of the agency’s missions. NAS provides a balanced environment, funded under the High-End Computing Capability (HECC) project, comprised of world-class supercomputers, including its flagship distributed-memory cluster, Pleiades; high-speed networking; and massive data storage facilities, along with multi-disciplinary support teams for user support, code porting and optimization, and large-scale data analysis and scientific visualization. However, as scientists have increased the fidelity of their simulations and engineers are conducting larger parameter-space studies, the requirements for supercomputing resources have been growing by leaps and bounds. With the facility housing the HECC systems reaching its power and cooling capacity, NAS undertook a prototype project to investigate an alternative approach for housing supercomputers. Modular supercomputing, or container-based computing, is an innovative concept for expanding NASA’s HPC capabilities. With modular supercomputing, additional containers—similar to portable storage pods—can be connected together as needed to accommodate the agency’s ever-increasing demand for computing resources. In addition, taking advantage of the local weather permits the use of cooling technologies that would additionally save energy and reduce annual water usage. The first stage of NASA’s Modular Supercomputing Facility (MSF) prototype, which resulted in a 1,000 square-foot module on a concrete pad with room for 16 compute racks, was completed in Fall 2016 and an SGI (now HPE) computer system, named Electra, was deployed there in early 2017. Cooling is performed via an evaporative system built into the module, and preliminary experience shows a Power Usage Effectiveness (PUE) measurement of 1.03. Electra achieved over a petaflop on the LINPACK benchmark, sufficient to rank number 96 on the November 2016 TOP500 list [14]. The system consists of 1,152 InfiniBand-connected Intel Xeon Broadwell-based nodes. Its users access their files on a facility-wide file system shared by all HECC compute assets via Mellanox MetroX InfiniBand extenders, which connect the Electra fabric to Lustre routers in the primary facility over fiber-optic links about 900 feet long. The MSF prototype has exceeded expectations and is serving as a blueprint for future expansions. In the remainder of this chapter, we detail how modular data center technology can be used to expand an existing compute resource. We begin by describing NASA’s requirements for supercomputing and how resources were provided prior to the integration of the Electra module-based system.

Biswas, Rupak↗

Configuration trade-offs for the Space Infrared Telescope Facility pointing control system

Conceptual pointing control system designs for the Space Infrared Telescope Facility (SIRTF) are examined in terms of fine guidance pointing and large-angle slewing accuracies. In particular, basic trade-offs between body pointing only and body pointing plus image motion compensation (IMC) are considered using a steady-state linear covariance analysis to compute rms pointing errors. It is shown that body pointing can provide good performance during nominal fine pointing but limits the telescope capability to rapidly slew and acquire targets. Overall, body pointing plus IMC would offer superior performance but must be judged against the difficulties posed by the attitude sensor noise and the higher cost and complexity of IMC. It is recommended that improved sensor designs be pursued while slewing performance be enhanced by a combination of an appropriate command profile and control compensation.

Pue, A. J.↗

Guide de base pour l'energie solaire hors reseau en Haiti: 10. Utilisation productive de l'energie

Cette formation donne un apercu des informations et des concepts cles de l'energie solaire hors reseau en Haiti, renforcant ainsi les connaissances fondamentales et la capacite de catalyser l'interet pour l'energie solaire hors reseau pour l'electrification rurale en Haiti. Ce cours a rythme libre est offert en anglais et en francais et couvre une variete de sujets lies a l'acces a l'energie en Haiti, notamment les produits solaires hors reseau, le potentiel du marche en Haiti, les considerations liees a l'offre et a la demande, la conception, l'installation et la maintenance du systeme, -modeles commerciaux solaires en reseau, modelisation financiere, genre et acces a l'energie, utilisation productive de l'energie et adaptation au climat. La formation est destinee aux etudiants universitaires, aux partenaires gouvernementaux, aux ONG, aux bailleurs de fonds, aux partenaires de developpement, aux professionnels, etc. Aucune connaissance prealable du solaire hors reseau ou d'Haiti n'est requise pour beneficier de cette formation. See NREL/PR-7A40-89253 for the English translation of this document.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗