Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PTFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tribological properties of PDA + PTFE coating in oil-lubricated condition

In this work the tribological properties of 45 ± 2 μm-thick polytetrafluoroethylene (PTFE) and polydopamine (PDA) + PTFE coatings in oil-lubricated conditions were investigated under a normal load of 10 N and a linear reciprocating speed of 0.1 m/s. Both the PTFE and the PDA + PTFE coatings were deposited using an in-house spray-coating method. The PDA + PTFE coating was five times more durable compared to the PTFE coating in oil-lubricated conditions. Both PTFE and PDA + PTFE coatings showed lower COF in oil-lubricated conditions than in dry conditions. The nanomechanical properties measured by PeakForce Quantitative Nanomechanical (PFQNM) characterization method showed an increase in Young’s modulus and adhesion force for the PDA + PTFE coatings compared to the PTFE coatings. Chemical analysis showed that the cross-linking between PDA and PTFE polymer chains occurred during the high-temperature sintering procedure. Finally, the higher adhesion of PDA + PTFE coating to the cast iron substrate and the stronger cohesion due to the cross-linking between PDA and PTFE contributed to the higher durability of the PDA + PTFE composite coatings.

36 MATERIALS SCIENCE↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the Chemistry of the Cathodic Electrolyte Interphase for PTFE-Based Dry-Processed Cathodes

Dry processing is a promising method for high-performance and low-cost lithium-ion battery manufacturing which uses polytetrafluoroethylene (PTFE) as a binder. However, the electrochemical stability of the PTFE binder in the cathodes and the generated chemistry of the cathode electrolyte interphase (CEI) layers are rarely reported. In this work, the CEI properties and PTFE electrochemical stability are studied via cycling the high-loading dry-processed electrodes in electrolytes with LiPF 6 or LiClO 4 salt. Using LiClO 4 salt can eliminate other possible F sources, allowing the decomposition of PTFE to be studied. The detection of LiF in cells with the LiClO 4 salt confirms that PTFE undergoes side reaction(s) in the cathodes. When compared with LiClO 4 , the CEI layer is much thicker when LiPF 6 is used as the electrolyte salt. These results provide insights into the CEI layer and may potentially enlighten the development of binders and electrolytes for the high efficiency and long durability of DP-based LIBs.

25 ENERGY STORAGE↗

Promoting propane dehydrogenation over PtFe bimetallic catalysts by optimizing the state of Fe species

Optimizing the structure of Pt-based bimetallic catalysts is of utmost importance toward improving the propane dehydrogenation performance. It is challenging to precisely synthesize uniform PtFe alloy nanoparticles without excess unalloyed Fe species on the support as these Fe species lead to low propylene selectivity, coke deposition, and poor stability. Herein, we report an effective strategy to optimize the structure of PtFe bimetallic catalysts with minimal coke and high turnover frequency (8.2 s -1 ). For the optimized catalyst, 1Pt3Fe@S-1, most Fe species is in the framework of the zeolite S-1, which significantly suppresses the formation of coke. In addition, the extra-framework Fe and Pt species encapsulated in the channel of zeolite form uniform PtFe alloy nanoparticles, which significantly improves the C 3 H 6 selectivity, catalytic stability, and recycling performance. In conclusion, these findings provide insights into the structure-performance relationship of PtFe bimetallic catalysts and shall be beneficial to future design and optimization of similar catalytic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stable Cycling with Intimate Contacts Enabled by Crystallinity–Controlled PTFE–Based Solvent–Free Cathodes in All–Solid–State Batteries

All-solid-state batteries (ASSBs) employing Li-metal anodes and inorganic solid electrolytes are attracting great attention due to high safety and energy density for next-generation energy storage devices. However, the volume change of cathode active materials can cause contact loss, resulting in charge carrier isolation, heterogeneous current distribution, and poor electrochemical properties in ASSBs. Here, a simple, yet effective, solvent-free electrode engineering approach with polytetrafluoroethylene (PTFE) as a binder for ASSBs is reported, enabling intimate contact and stable interfaces with the cathode. It is substantiated that the crystallinity of PTFE can be controlled depending on the heat history, and highly crystalline PTFE displays robust mechanical properties. High-nickel LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode prepared with crystalline PTFE show improved cycle and rate performances in ASSBs. In addition, it is revealed that the intimate contact between cathode particles with a stable cathode electrolyte layer is maintained during cycling by postmortem studies. Furthermore, this simple engineering method can be applied to prepare cathodes with a variety of active materials and solid electrolytes in ASSBs.

25 ENERGY STORAGE↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. Here, in this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200 nm, 260 nm, and 450 nm. The results show that TPB-coated PTFE has a reflectance of approximately 92% for thicknesses ranging from 5 mm to 10 mm at 450 nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5 mm to 10 mm does not affect significantly the light response at 128 nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10 mm can be used in particle physics detectors without compromising the light signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX

Abstract Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring very low radiation doses in PTFE for nuclear forensic enrichment reconstruction

Every country that has made nuclear weapons has used uranium enrichment to do so. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment in the open literature that can be used to perform forensic verification of historically produced weapons on gas centrifuges. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon’s quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing detection of tampering and a method for analyzing field samples useful for treaty verification. Furthermore, this work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measuring Very Low Radiation Doses in PTFE for Nuclear Forensic Enrichment Reconstruction

Every country that has made nuclear weapons has used uranium enrichment. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment that can be used to perform forensic verification of historically produced weapons. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon's quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing a detection of tampering and a method for analyzing field samples useful for treaty verification. This work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

Connick, Rachel↗

Unraveling the multi-step crystallization mechanism of polytetrafluoroethylene, modified polytetrafluoroethylene, and their nanocomposites with boron nitride nanobarbs: Experimental insights and theoretical analysis

The non-isothermal crystallization behavior and kinetics of polytetrafluoroethylene (PTFE) composites with boron nitride nanobarb (BNNB), a new generation nanostructure with unique surface morphology and mechanical “barbs” have been analyzed, understanding these properties is essential for their high-end applications as thermal interface materials (TIM) for microwave, 5G and microelectronic devices. The analysis of the crystallization parameters includes crystallization onset, peak and end temperatures, crystallization half-life and overall crystallinity of PTFE, modified PTFE and their BNNB composites. The results were further analyzed using theoretical models such as the combined Avrami-Ozawa model. It was found that BNNB supports crystallization in the modified PTFE but shows minimal effect on the crystallization of PTFE. Due to the limitation of the classical theoretical models used above in fully characterizing the multi-step crystallization process of PTFE, an in-depth analysis using the model-free advanced isoconversional computation was used to characterize the PTFE crystallization based on the evolution of activation energy with fractional crystallinity and for the first time with temperature. Three kinetic regions were identified in the crystallization mechanism. Here, this study investigated the molecular organization and microstructural evolution of PTFE, modified PTFE and their composites during non-isothermal crystallization using advanced X-ray scattering measurements. An insight into the changes undergone by the material's microstructural units including crystallite size and morphology, lamellar thickness and lamellar interfacial layer thickness, and crystallographic phase dynamics during non-isothermal cooling from the melt, was provided here in this work. The effect of copolymer modification of PTFE and the inclusion of pristine and functionalized BNNB (a thermally conductive and electrically insulating ceramic) are both new investigations that provide valuable knowledge for the development of materials with strong matrix-nanofiller interaction and guidance for optimizing sintering and cooling cycles, two key steps in PTFE processing that largely affect the material microstructural features. Overall, the result of the three-part investigation demonstrates that BNNB supports crystallization in the modified PTFE up to 20 wt% concentration and at low and high cooling rates typically used in the industrial processing of PTFE.

36 MATERIALS SCIENCE↗

Development of Nanocomposite Coatings for Future Large-Scale Time Projection Chambers

In the context of this award we tested the performance of thin high-resistivity coatings for their potential usage as field shaping systems in future large scale xenon Time Projection Chambers (TPC). A successful implementation of such thin coatings would likely simplify the design of potential future detectors, allowing to overcome some of the challenges observed with traditional systems constituted by massive discrete electrodes. We studied a wide range of materials and characterized their optical and electrical performances as functions of temperature and wavelength. The measurement campaign indicated that uniform coatings covering the full PTFE substrate (usually used as reflector in LXe TPCs) impact too severely on the light collection performance of such detectors when used with deep UV light. Despite tuning the composition and thicknesses of nanocomposite coatings, we were not able to identify a single coating, properly working at LXe temperature, that would simultaneously fulfill the resistance and optical requirements. Following the risk mitigation strategy identified in the proposal we moved the focus of the R&D to identify proper materials that, when coated with grid-like patterns on PTFE, would not alter meaningfully its optical properties (with respect to bare PTFE panels) but would still serve as effective field shaping systems, properly containing the drift field in TPC detectors. Among the various materials we identified germanium as the most promising one, providing a good adhesion to PTFE and the proper range of sheet resistivity. The Ge-patterned coating tested within a small scale LXe TPC showed good performance as a field shape system and, as desired, did not reduce the detector light yield. These results are encouraging and such technology should further be investigated as a potential alternative to more traditional field shaping electrodes. Incidentally, in the context of this R&D, we stumbled upon an unexpected behavior suggesting that some of the treatments performed on the PTFE panels, in preparation of the coatings, meaningfully boosted the PTFE reflectivity. The most probable candidate is the O2 plasma cleaning procedure. This hypothesis will be tested in the near future by operating the small scale TPC at UChicago first with regular PTFE panels and then with panels bombarded with O2 plasma (but no coatings). This finding, if confirmed, might open up the possibility of further boosting UV light collection in future large detectors by performing such a treatment on the PTFE surfaces.

36 MATERIALS SCIENCE↗

Effect of Cu nanoparticles on the tribological performance of polydopamine + polytetrafluoroethylene coatings in oil-lubricated condition

For this study, the effect of Cu nanoparticles (NPs) on the tribological performance of the thick polydopamine (PDA) + polytetrafluoroethylene (PTFE) coatings in DTE-32 Mobil lubricated condition was investigated. PDA + PTFE + Cu NP coatings with 45 µm thickness were spray-coated with 0.12, 0.25, and 0.50 wt% of Cu NPs in an aqueous PDA + PTFE solution, respectively. The mechanical properties were studied by PeakForce quantitative nanomechanical (PFQNM) characterization and nanoindentation. The Young's modulus increased, and the coefficient of friction (COF) reduced with the addition of Cu NPs compared to PDA + PTFE coating. The PDA + PTFE + 0.25 wt% Cu and PDA + PTFE + 0.50 wt% Cu coatings increased the durability by 52% and 33%, respectively, compared to the coating without Cu NPs. The better tribological performance of the nanocomposite coatings is contributed by the better mechanical properties, better adherence, and enhanced cross-linking between the constituents of the nanocomposite coatings due to the presence of Cu NPs. The addition of 0.25 wt% Cu NPs in PDA + PTFE increased the thermal conductivity by 12%.

36 MATERIALS SCIENCE↗

Dry-processed electrodes enabled by polytetrafluoroethylene fibrillation for high-performance lithium-ion batteries

The dry processing technique of polytetrafluoroethylene (PTFE) fibrillation offers significant advancements in cost reduction, environmental impact, and electrochemical performance. Dry processing alone allows for ∼ 20–60% cost reduction and increases of up to 40 mg cm⁻2 of areal loading – it typically comes at a reduction of rate capability. By leveraging the network structure of fibers, this method enhances rate capability and cycling performance, providing a compelling alternative to the conventional and currently predominant wet processing. The review delves into PTFE fibrillation mechanisms and examines critical influencing factors including material properties and processing parameters. It also discusses challenges associated with the electrodes fabricated by PTFE fibrillation, including structural instability due to insufficient PTFE fibrillization, compromised electrical conductivity from an insufficient conductive network, inhomogeneous dispersion resulting from the absence of solvents, restricted ionic transport due to increased electrode thickness, inadequate adhesion to current collector because of low surface energy of PTFE, electrochemical degradation due to low lowest unoccupied molecular orbital (LUMO) level of PTFE, particle damage during processing and environmental concerns related PTFE being a perfluoroalkyl and polyfluoroalkyl substances (PFAS). Recent research innovations aimed at mitigating these issues, their application in beyond-lithium batteries, and future research directions are thoroughly discussed.

Park, Hyunji↗

Manufacturing Cathodes via Dry-Processing for Lithium-Ion Batteries

Conventional lithium-ion battery (LIB) electrodes are prepared through a wet slurry process with n-methyl pyrrolidone solvent, especially for cathodes. The wet slurry process encounters several disadvantages such as binder migration, electrode cracking in thick electrodes, energy intense heat-dry NMP solvent removal, and costly NMP recovery. The cost and energy consumption of coating and drying of electrode are about 11.5 % and > 46 % in LIB manufacturing, respectively. Thereby, it is essential to develop a facile roll-to-roll solvent-free LIB electrode processing for reducing the cost and energy consumption. Recently, the Maxwell-type dry processing (DP) shines new lights on LIB manufacturing, which mainly bases on dry mixing (DM) of electrode component powder followed by calendering into electrode films and laminating onto current collectors, realizing the rapid manufacturing of LIB electrodes in a powder-to-film manner for industries. This report shares some recent progress on the DP from our group. We aim to further advance the manufacturing science of DP by correlating the processing conditions with electrode properties and performance. Particularly, we investigate the effect of DM, and compression on the polytetrafluoroethylene (PTFE) binder fiberization, porosity, mechanical properties, electrical conductivity and electrochemical behaviors of electrodes. The DM study suggests that PTFE fiberization heavily relies on the degree of DM. Insufficient DM results in poor PTFE fiberization while outrageous DM damages the formed PTFE fibers. Both negatively affect the mechanical behaviors of the electrodes and their rate capability. However, moderate DM is highly beneficial. In addition, our study of the porosity impact reveals that LiNi0.8Mn0.1Co0.1O2 (NMC) secondary particles can be broken into primary particles due to compression, especially at low porosity. Those fractured NMC secondary particles exhibit lower modulus. We propose that a moderate porosity of around 32% favors the electronic conductivity, charge transfer impedance and rate capability. The study of the cathodic electrolyte interphase layer of PTFE-based DPed electrode confirms that side reactions of PTFE binder due to the formation of LiF in LiClO4-based electrolyte.

Tao, Runming↗