Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Investigation of boosted proton energies through proton radiography of target normal sheath acceleration fields in the multi-ps regime

Multi-kilojoule, multi-picosecond short-pulse lasers, such as the National Ignition Facility-Advanced Radiographic Capability laser and the OMEGA-Extended Performance laser, which have been constructed over the last two decades, enable exciting opportunities to produce high-brightness, high-energy laser-driven proton sources for applications in high-energy-density science like proton fast ignition for inertial fusion energy, particle radiography, and materials science studies. Results on these platforms have demonstrated enhanced accelerated proton energies and electron temperatures when compared to established scaling laws. Recent work has developed a new scaling for proton TNSA in the multi-ps regime. However, this new physics in the multi-ps regime motivates the need to understand the origin of the enhancement in proton energies. Toward this goal, here this work presents the first measurements of the TNSA accelerating sheath field in the multi-ps regime for pulse durations of 0.6, 5, and 10 ps. This measurement was achieved by using a separate TNSA proton source to radiograph the spatiotemporal profile of the accelerating sheath that is responsible for proton acceleration. The use of stacked radiochromic film detectors allows for a discrete time profile of the radiographs, thus enabling the measurement of the temporal and spatial evolution of the accelerating field. In performing this measurement, we extract quantities such as the sheath strength as a function of time and pulse duration, which shows that longer pulse durations sustain a stronger electric field for a longer duration when compared to sub-ps laser pulses, which may enable the observed boosted proton energies and proton conversion efficiencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermally Grown Oxide Stress in PS-PVD and EB-PVD Thermal Barrier Coatings Observed at Various Lifetimes Via Synchrotron X-ray Diffraction

The current standard application method for thermal barrier coatings (TBCs) on turbine blades for jet engines is electron-beam physical vapor deposition (EB-PVD) due to its high strain tolerance and low thermal conductivity. An emerging deposition method, plasma-spray physical vapor deposition (PS-PVD), presents an opportunity for a tailorable microstructure, and non-line-of-sight deposition that is faster and less expensive. To compare the lifetime behavior of both PS-PVD and EB-PVD coatings, samples subjected to 300 and 600 thermal cycles were measured during a 1 h thermal cycle to determine the strains, which were converted to stress, in the thermally grown oxide (TGO) layer of the TBCs using synchrotron X-ray diffraction (XRD). Room temperature XRD measurements indicated among samples that PS-PVD coatings experienced greater variation in in-plane room temperature strain in the TGO after cycling than the EB-PVD coatings. In-situ XRD measurements indicated similar high-temperature strain and no spallation after 600 thermal cycles for both coatings. Further, microscopy imaging after cycling showed greater rumpling in PS-PVD coatings that led to different failure modes between the two coatings’ TGO layers. The tailorability of PS-PVD coatings allows for adjustments in the processing parameters to improve their overall performance after aging and bridge the differences between the two deposition methods.

36 MATERIALS SCIENCE↗

Site Disorder Drives Cyanide Dynamics and Fast Ion Transport in Li 6 PS 5 CN

Halide argyrodite solid-state electrolytes of the general formula Li 6 PS 5 X exhibit complex static and dynamic disorder that plays a crucial role in ion transport processes. Here, we unravel the rich interplay between site disorder and dynamics in the plastic crystal argyrodite Li 6 PS 5 CN and the impact on ion diffusion processes through a suite of experimental and computational methodologies, including temperature-dependent synchrotron powder X-ray diffraction, AC electrochemical impedance spectroscopy, 7 Li solid-state NMR, and machine learning-assisted molecular dynamics simulations. Sulfide and (pseudo)halide site disorder between the two anion sublattices unilaterally improves long-range lithium diffusion irrespective of the (pseudo)halide identity, which demonstrates the importance of site disorder in dictating bulk ionic conductivity in the argyrodite family. Furthermore, we find that anion site disorder modulates the presence and time scales of cyanide rotational dynamics. Ordered configurations of anions enable fast, quasi-free rotations of cyanides that occur on time scales of 10 11 Hz at T = 300 K. In contrast, we find that cyanide dynamics are slow or frozen in Li 6 PS 5 CN when site disorder between the cyanide and sulfide sublattices is present at T = 300 K. We rationalize the observed differences in cyanide dynamics in the context of elastic dipole interactions between neighboring cyanide anions and local strain induced by the configurations of site disorder that may impact the energetic landscape for cyanide rotational dynamics. Through this study, we find that anion disorder plays a decisive role in dictating the extent and time scales of both lithium ion and cyanide dynamics in Li 6 PS 5 CN.

36 MATERIALS SCIENCE↗

Single-shot ultrafast dynamics of nanosecond pulsed plasmas: Transition from ps–ns nonequilibrium to near-full ionization

The ultrafast multi-stage evolution of state-defining properties in atmospheric-pressure nanosecond pulsed plasmas is quantified using single-discharge, jitter-free, continuous streak-sweep spectroscopy of N 2 (C → B) molecular and N + /O + ionic species with a single-shot time resolution as short as ∼160 ps. An early period of extreme nonequilibrium is observed with vibrational temperatures [T V (C)] dropping from ∼8000 K at <200 ps after plasma breakdown to <4000 K within ∼1 ns, with near-ambient rotational temperatures [T R (C)] ∼ 300 K due to limited collisional energy transfer. This early-time T V (C) trend is representative of a direct and unquenched look into the high-energy tail of the electron energy distribution function; thus, it tracks real-time changes in the mean electron energy via the N2(C) emission signatures. This is followed by the rapid onset of N + /O + ionic emission after a distinct time delay of ∼14.9 ns due to multistep chemical kinetics. The ionic emission enables determination of electron densities (n e ) >2 × 10 19 cm −3 and electron temperatures (T e ) >36 000 K, indicating the transition to a nearly fully ionized regime. The ps–ns temporal dynamics are also compared between air and N 2 plasmas to assess the influence of collisional partners, as well as across the anode, cathode, and central gap regions to identify spatial variations in plasma behavior. Finally, this work demonstrates versatile continuously probing approach capable of spectro-temporal and spatially resolved single-shot measurements of key state variables in the ps–ns evolution of atmospheric-pressure nanosecond pulsed plasmas.

Electric discharges↗

High-energy, low-jitter, narrowband ps probe laser for kHz-rate fs/ps coherent anti-Stokes Raman scattering

Hybrid fs/ps coherent anti-Stokes Raman scattering (CARS) thermometry often utilizes ps probe pulses derived from pulse shaping or spectrally filtering the primary laser source or by synchronization with a low repetition rate external laser. This results in limited energy, spectral resolution, and/or repetition rate of the ps probe. In this work, a master-oscillator power-amplifier (MOPA) laser was synchronized to the oscillator of a Ti:sapphire regenerative amplifier to achieve high-energy (600 µJ), narrowband (58 ps) probe pulses at kHz repetition rates. Furthermore, temporal filtering allows the pulse characteristics to be adjusted for each application. At 25 Torr, relevant to high-speed flows, the kHz-rate MOPA system generated signal-to-noise ratios 3× higher in nitrogen and had improved precision relative to a 10 ps probe derived from spectral filtering and the power-amplifier. The MOPA system also enabled single-shot ro-vibrational hybrid fs/ps CARS thermometry in 650 K heated air.

47 OTHER INSTRUMENTATION↗

PS: A nonprocedural language with data types and modules

The Problem Specification (PS) nonprocedural language is a very high level language for algorithm specification. PS is suitable for nonprogrammers, who can specify a problem using mathematically-oriented equations; for expert programmers, who can prototype different versions of a software system for evaluation; and for those who wish to use specifications for portions (if not all) of a program. PS has data types and modules similar to Modula-2. The compiler generates C code. PS is first shown by example, and then efficiency issues in scheduling and code generation are discussed.

Gokhale, M. B.↗

Doubly excited 3P(e) resonant states in Ps(-)

Doubly excited 3P(e) resonant states in Ps(-) are calculated using a method of complex-coordinate rotation. Resonance parameters (both resonance positions and widths) for doubly excited states associated with the n = 2, 3, 4, 5, and 6 thresholds of positronium atoms are evaluated using elaborate Hylleraas-type functions. In addition to ten Feshbach-type resonances lying below various Ps thresholds, three shape resonances were identified, one each lying above the n = 2, 4, and 6 Ps thresholds. It is further noted that the energy levels for the present 3P(e) states are nearly degenerate with respect to the previously calculated 1P(0) states. Such a symmetric character suggests that the highly and doubly excited Ps(-), similar to its counterpart in H(-), would exhibit rovibrational behaviors analogous to those of XYX triatomic molecules.

Ho, Y. K.↗

Polarizabilities of the Ps Negative Ion

We have calculated polarizabilities (alpha(sub l), beta(sub 1), gamma(sub l), alpha(sub 2), beta(sub 2), and gamma(sub 2)) of Ps(sup -) by the pseudostate method. These parameters can be used to calculate Rydberg states of Ps(sup -) in the presence of an external electron with high quantum numbers N and L. They are also of importance in a system containing Ps(sup -) bound to a proton [PsH], and also Rydberg states of Ps(sub 2).

Bhatia, A. K.↗

The Photodetachment of Ps ion and Low-Energy e(+) -H Collisions

Two calculations in the area of positron collisions are presented. The first is the calculation of the photodetachment cross section of the positronium negative ion (Ps-) using accurate variational wave functions for both the initial bound-state and the final P continuum state. The second is the calculation of partial wave cross sections for Ps(1s)-formation in ef -H(ls) collisions using the hyperspherical hidden crossing method. Since the S-wave Stiickelberg phase is close to pi, the very small S-wave Ps(1s) formation cross section can be understood in terms of destructive interference. Other examples in positron collisions are given where it is either known or expected that destructive interference is the cause of the small S-wave Ps(1s) formation cross section. In addition, examples are presented of processes in atomic physics where the Stiickelberg phase is a multiple of pi/2.

Ward, S.J.↗

Leveraging Multi-Primary PS-InSAR Configurations for the Robust Estimation of Coastal Subsidence

InSAR is a key technique used to constrain contributions of diverse processes to coastal subsidence, also known as vertical land motion (VLM). However, coastal environments can pose major challenges for InSAR due to natural disturbances that degrade interferogram quality. We describe a new multi-primary pairing strategy for persistent scatterer InSAR (PS-InSAR) to estimate subsidence in challenging coastal environments. Our method retains only consistent PS candidates across multiprimary substacks and solves for redundant velocity observations using SVD-based inversion, similar to the conventional small baseline subset (SBAS) method. Through simulations and a case study comparing with single-primary PS-InSAR and conventional SBAS techniques, we show that our pairing strategy reduces temporal and spatial uncertainty in subsidence estimates in the presence of strong but temporary decorrelation loss, even with increased distance from the reference point. Moreover, our method visibly dampens time-series variation and decreases standard error in our time series fit by nearly 2x in our case study. Thus, we find that implementing a multi-primary PS-InSAR configuration is a simple method of increasing the robustness of VLM estimates in challenging coastal environments.

Persistent scatterer InSAR↗

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of LAPPD timing at CERN PS testbeam

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Arbitrary Time Interval Generator Base on Vernier Clocks with 0.67 ps Adjustable Steps Implemented in FPGA

In TDC testing and timing system implementations, it is often necessary to generate signal pulses with finely adjustable time intervals. In delay cell–based schemes, the adjustment resolution is constrained by the propagation delay of the cells—typically 15–20 ps per step—and is sensitive to temperature and supply voltage variations. This document presents a fully digital approach that uses two vernier clocks, generated by two stages of cascaded phase-locked loops (PLLs) with a slight frequency difference, to achieve adjustable timing intervals through accumulated phase differences. The scheme was validated on two families of low-cost FPGA devices, achieving adjustable step sizes of 0.67 ps and 0.97 ps.

Wu, Jin-yuan [Fermilab] (ORCID:0000000344329521)↗

Understanding the Role of Borohydride Doping in Electrochemical Stability of Argyrodite Li 6 PS 5 Cl Solid‐State Electrolyte

This work elucidates the mechanism by which lithium borohydride (LiBH 4 ) doping into argyrodite-type Li 6 PS 5 Cl (LBH-LPSCl) solid-state electrolyte (SSE) enhances electrochemical stability. State-of-the-art electrochemical performance is achieved with 5 wt% borohydride. Symmetric cells achieve critical current density (CCD) of 7.3 mA cm −2 , versus 2.6 mA cm −2 for baseline-LPSCl. All solid-state batteries (ASSBs) employing lithium metal and NMC811 cathode are stable over 400 cycles at 0.5C, with capacity retention of 83%. An anode-free ASSB (AF-ASSB) is stable over 600 cycles, with capacity loss of 0.04% per cycle. 5LBH-LPSCl allows for enhanced low temperature operation, down to −14 °C. Yet the difference in electrolytes’ bulk microstructures and hardnesses are minimal, while ionic conductivity is incrementally improved (≈50%). Theoretical modeling indicates limited effect of substitution on thermodynamic stability of PS 4 3- units, which decompose when contacting Li. Instead, enhanced electrochemical stability is site-specific kinetic effect: In situ electrodeposition experiments using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) reveal tri-layer SEI based predominately on Li 3 P/LiBH 4 /Li 2 S that blocks electrons while facilitating ion transport. This SEI manifests reduced interface resistance and accelerated nucleation and growth of metallic Li. With baseline-LPSCl the SEI based on Li 3 P/Li 2 S is substantially thicker, generating localized stresses that promote interfacial cracking while cycling.

argyrodite↗

Observations of a gradual transition between Ps 6 activity with auroral torches and surgelike pulsations during strong geomagnetic disturbances

This paper describes a long-lasting large-amplitude pulsation event, which occurred on January 10, 1983 in the ionosphere and magnetosphere and was characterized by Steen and Rees (1983). Over the 4-h period (0200-0600 UT), the characteristics of the pulsations in the ionosphere changed from being Ps 6 auroral torches toward substorms and back to Ps 6. At GEO, the corresponding characteristics were a modulation of the high-energy particle intensity and plasma dropouts. Based on the ideas presented by Rostoker and Samson (1984), an interpretation of the event is offered, according to which the pulsations are caused by the Kelvin-Helmholtz instability during an interval of strong magnetospheric convection. On the basis of this explanation, a new interpretation of the substorm time sequence is proposed.

Steen, A.↗