Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The miR-183 family cluster alters zinc homeostasis in benign prostate cells, organoids and prostate cancer xenografts

The miR-183 cluster, which is comprised of paralogous miRs-183, -96 and -182, is overexpressed in many cancers, including prostate adenocarcinoma (PCa). Prior studies showed that overexpression of individual pre-miRs-182, -96 and -183 in prostate cells decreased zinc import, which is a characteristic feature of PCa tumours. Zinc is concentrated in healthy prostate 10-fold higher than any other tissue, and an >80% decrease in zinc is observed in PCa specimens. Here, we studied the effect of overexpression of the entire 4.8 kb miR-183 family cluster, including the intergenic region which contains highly conserved genomic regions, in prostate cells. This resulted in overexpression of mature miR-183 family miRs at levels that mimic cancer-related changes. Overexpression of the miR-183 cluster reduced zinc transporter and intracellular zinc levels in benign prostate cells, PCa xenografts and fresh prostate epithelial organoids. Microarray analysis of miR-183 family cluster overexpression in prostate cells showed an enrichment for cancer-related pathways including adhesion, migration and wound healing. An active secondary transcription start site was identified within the intergenic region of the miR-183 cluster, which may regulate expression of miR-182. Taken together, this study shows that physiologically relevant expression of the miR-183 family regulates zinc levels and carcinogenic pathways in prostate cells.

Science & Technology - Other Topics↗

SU-E-J-150: Impact of Intrafractional Prostate Motion On the Accuracy and Efficiency of Prostate SBRT Delivery: A Retrospective Analysis of Prostate Tracking Log Files

Purpose: To measure intrafractional prostate motion by time-based stereotactic x-ray imaging and investigate the impact on the accuracy and efficiency of prostate SBRT delivery. Methods: Prostate tracking log files with 1,892 x-ray image registrations from 18 SBRT fractions for 6 patients were retrospectively analyzed. Patient setup and beam delivery sessions were reviewed to identify extended periods of large prostate motion that caused delays in setup or interruptions in beam delivery. The 6D prostate motions were compared to the clinically used PTV margin of 3–5 mm (3 mm posterior, 5 mm all other directions), a hypothetical PTV margin of 2–3 mm (2 mm posterior, 3 mm all other directions), and the rotation correction limits (roll ±2°, pitch ±5° and yaw ±3°) of CyberKnife to quantify beam delivery accuracy. Results: Significant incidents of treatment start delay and beam delivery interruption were observed, mostly related to large pitch rotations of ≥±5°. Optimal setup time of 5–15 minutes was recorded in 61% of the fractions, and optimal beam delivery time of 30–40 minutes in 67% of the fractions. At a default imaging interval of 15 seconds, the percentage of prostate motion beyond PTV margin of 3–5 mm varied among patients, with a mean at 12.8% (range 0.0%–31.1%); and the percentage beyond PTV margin of 2–3 mm was at a mean of 36.0% (range 3.3%–83.1%). These timely detected offsets were all corrected real-time by the robotic manipulator or by operator intervention at the time of treatment interruptions. Conclusion: The durations of patient setup and beam delivery were directly affected by the occurrence of large prostate motion. Frequent imaging of down to 15 second interval is necessary for certain patients. Techniques for reducing prostate motion, such as using endorectal balloon, can be considered to assure consistently higher accuracy and efficiency of prostate SBRT delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transurethral Resection of the Prostate (TURP) Versus Original and PErFecTED Prostate Artery Embolization (PAE) Due to Benign Prostatic Hyperplasia (BPH): Preliminary Results of a Single Center, Prospective, Urodynamic-Controlled Analysis

PurposeTo compare clinical and urodynamic results of transurethral resection of the prostate (TURP) to original and PErFecTED prostate artery embolization (PAE) methods for benign prostatic hyperplasia.MethodsWe prospectively randomized 30 patients to receive TURP or original PAE (oPAE) and compared them to a cohort of patients treated by PErFecTED PAE, with a minimum of 1-year follow-up. Patients were assessed for urodynamic parameters, prostate volume, international prostate symptom score (IPSS), and quality of life (QoL).ResultsAll groups were comparable for all pre-treatment parameters except bladder contractility and peak urine flow rate (Q{sub max}), both of which were significantly better in the TURP group, and IIEF score, which was significantly higher among PErFecTED PAE patients than TURP patients. All groups experienced significant improvement in IPSS, QoL, prostate volume, and Q{sub max}. TURP and PErFecTED PAE both resulted in significantly lower IPSS than oPAE but were not significantly different from one another. TURP resulted in significantly higher Q{sub max} and significantly smaller prostate volume than either original or PErFecTED PAE but required spinal anesthesia and hospitalization. Two patients in the oPAE group with hypocontractile bladders experienced recurrence of symptoms and were treated with TURP. In the TURP group, urinary incontinence occurred in 4/15 patients (26.7 %), rupture of the prostatic capsule in 1/15 (6.7 %), retrograde ejaculation in all patients (100 %), and one patient was readmitted for temporary bladder irrigation due to hematuria.ConclusionsTURP and PAE are both safe and effective treatments. TURP and PErFecTED PAE yield similar symptom improvement, but TURP is associated with both better urodynamic results and more adverse events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostatic Artery Embolization for Enlarged Prostates Due to Benign Prostatic Hyperplasia. How I Do It

Prostatic artery embolization (PAE) has emerged as an alternative to surgical treatments for benign prostatic hyperplasia (BPH). Patient selection and refined technique are essential for good results. Urodynamic evaluation and magnetic resonance imaging are very important and technical limitations are related to elderly patients with tortuous and atherosclerotic vessels, anatomical variations, difficulty visualizing and catheterizing small diameter arteries feeding the prostate, and the potential risk of bladder and rectum ischemia. The use of small-diameter hydrophilic microcatheters is mandatory. Patients can be treated safely by PAE with low rates of side effects, reducing prostate volume with clinical symptoms and quality of life improvement without urinary incontinence, ejaculatory disorders, or erectile dysfunction. A multidisciplinary approach with urologists and interventional radiologists is essential to achieve better results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Offline multiple adaptive planning strategy for concurrent irradiation of the prostate and pelvic lymph nodes

Purpose: Concurrent irradiation of the prostate and pelvic lymph nodes (PLNs) can be challenging due to the independent motion of the two target volumes. To address this challenge, the authors have proposed a strategy referred to as Multiple Adaptive Planning (MAP). To minimize the number of MAP plans, the authors’ previous work only considered the prostate motion in one major direction. After analyzing the pattern of the prostate motion, the authors investigated a practical number of intensity-modulated radiotherapy (IMRT) plans needed to accommodate the prostate motion in two major directions simultaneously. Methods: Six patients, who received concurrent irradiation of the prostate and PLNs, were selected for this study. Nine MAP-IMRT plans were created for each patient with nine prostate contours that represented the prostate at nine locations with respect to the PLNs, including the original prostate contour and eight contours shifted either 5 mm in a single anterior-posterior (A-P), or superior-inferior (S-I) direction, or 5 mm in both A-P and S-I directions simultaneously. From archived megavoltage cone beam CT (MV-CBCT) and a dual imaging registration, 17 MV-CBCTs from 33 available MV-CBCT from these patients showed large prostate displacements (>3 mm in any direction) with respect to the pelvic bones. For each of these 17 fractions, one of nine MAP-IMRT plans was retrospectively selected and applied to the MV-CBCT for dose calculation. For comparison, a simulated isocenter-shifting plan and a reoptimized plan were also created for each of these 17 fractions. The doses to 95% (D95) of the prostate and PLNs, and the doses to 5% (D5) of the rectum and bladder were calculated and analyzed. Results: For the prostate, D95 > 97% of the prescription dose was observed in 16, 16, and 17 of 17 fractions for the MAP, isocenter-shifted, and reoptimized plans, respectively. For PLNs, D95 > 97% of the prescription doses was observed in 10, 3, and 17 of 17 fractions for the three types of verification plans, respectively. The D5 (mean ± SD) of the rectum was 45.78 ± 5.75, 45.44 ± 4.64, and 44.64 ± 2.71 Gy, and the D5 (mean ± SD) of the bladder was 45.18 ± 2.70, 46.91 ± 3.04, and 45.67 ± 3.61 Gy for three types of verification plans, respectively. Conclusions: The MAP strategy with nine IMRT plans to accommodate the prostate motions in two major directions achieved good dose coverage to the prostate and PLNs. The MAP approach can be immediately used in clinical practice without requiring extra hardware and software.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0.86%, and the prostate volume Dice overlap coefficient was 91.89% ± 1.19%. Conclusions: The authors have developed a novel approach to improve prostate contour utilizing intraoperative TRUS-based prostate volume in the CT-based prostate HDR treatment planning, demonstrated its clinical feasibility, and validated its accuracy with MRIs. The proposed segmentation method would improve prostate delineations, enable accurate dose planning and treatment delivery, and potentially enhance the treatment outcome of prostate HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

Influence of volumes of prostate, rectum, and bladder on treatment planning CT on interfraction prostate shifts during ultrasound image-guided IMRT

Purpose: The purpose of this study was to analyze the relationship between prostate, bladder, and rectum volumes on treatment planning CT day and prostate shifts in the XYZ directions on treatment days. Methods: Prostate, seminal vesicles, bladder, and rectum were contoured on CT images obtained in supine position. Intensity modulated radiation therapy plans was prepared. Contours were exported to BAT-ultrasound imaging system. Patients were positioned on the couch using skin marks. An ultrasound probe was used to obtain ultrasound images of prostate, bladder, and rectum, which were aligned with CT images. Couch shifts in the XYZ directions as recommended by BAT system were made and recorded. 4698 couch shifts for 42 patients were analyzed to study the correlations between interfraction prostate shifts vs bladder, rectum, and prostate volumes on planning CT. Results: Mean and range of volumes (cc): Bladder: 179 (42-582), rectum: 108 (28-223), and prostate: 55 (21-154). Mean systematic prostate shifts were (cm, {+-}SD) right and left lateral: -0.047{+-}0.16 (-0.361-0.251), anterior and posterior: 0.14{+-}0.3 (-0.466-0.669), and superior and inferior: 0.19{+-}0.26 (-0.342-0.633). Bladder volume was not correlated with lateral, anterior/posterior, and superior/inferior prostate shifts (P>0.2). Rectal volume was correlated with anterior/posterior (P<0.001) but not with lateral and superior/inferior prostate shifts (P>0.2). The smaller the rectal volume or cross sectional area, the larger was the prostate shift anteriorly and vice versa (P<0.001). Prostate volume was correlated with superior/inferior (P<0.05) but not with lateral and anterior/posterior prostate shifts (P>0.2). The smaller the prostate volume, the larger was prostate shift superiorly and vice versa (P<0.05). Conclusions: Prostate and rectal volumes, but not bladder volumes, on treatment planning CT influenced prostate position on treatment fractions. Daily image-guided adoptive radiotherapy would be required for patients with distended or empty rectum on planning CT to reduce rectal toxicity in the case of empty rectum and to minimize geometric miss of prostate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel approach for evaluation of prostate deformation and associated dosimetric implications in IGRT of the prostate

Purpose: Prostate deformation is assumed to be a secondary correction and is typically ignored in the planning target volume (PTV) margin calculations. This assumption needs to be tested, especially when planning margins are reduced with daily image-guidance. In this study, deformation characteristics of the prostate and seminal vesicles were determined, and the dosimetric impact on treatment plans with different PTV margins was investigated. Methods: Ten prostate cancer patients were retrospectively selected for the study, each with three fiducial markers implanted in the prostate. Two hundred CBCT images were registered to respective planning CT images using a B-spline-based deformable image registration (DIR) software. A manual bony anatomy-based match was first applied based on the alignment of the pelvic bones and fiducial landmarks. DIR was then performed. For each registration, deformation vector fields (DVFs) of the prostate and seminal vesicles (SVs) were quantified using deformation-volume histograms. In addition, prostate rotation was evaluated and compared with prostate deformation. For a patient demonstrating small and large prostate deformations, target coverage degradation was analyzed in each of three treatment plans with PTV margins of 10 mm (6 mm at the prostate/rectum interface), as well as 5, and 3 mm uniformly. Results: Deformation of the prostate was most significant in the anterior direction. Maximum prostate deformation of greater than 10, 5, and 3 mm occurred in 1%, 17%, and 76% of the cases, respectively. Based on DVF-histograms, DVF magnitudes greater than 5 and 3 mm occurred in 2% and 27% of the cases, respectively. Deformation of the SVs was most significant in the posterior direction, and it was greater than 5 and 3 mm in 7.5% and 44.9% of the cases, respectively. Prostate deformation was found to be poorly correlated with rotation. Fifty percent of the cases showed rotation with negligible deformation and 7% of the cases showed significant deformation with minimal rotation (<3°). Average differences in the D{sub 95} dose to the prostate + SVs between the planning CT and CBCT images was 0.4% ± 0.5%, 3.0% ± 2.8%, and 6.6% ± 6.1%, respectively, for the plans with 10/6, 5, and 3 mm margins. For the case with both a large degree of prostate deformation (≈10% of the prostate volume) and rotation (≈8°), D{sub 95} was reduced by 0.5% ± 0.1%, 6.8% ± 0.6%, and 20.9% ± 1.6% for 10/6, 5, and 3 mm margin plans, respectively. For the case with large prostate deformation but negligible rotation (<1°), D{sub 95} was reduced by 0.4 ± 0.3, 3.9 ± 1.0, and 11.5 ± 2.5 for 10/6, 5, and 3 mm margin plans, respectively. Conclusions: Prostate deformation over a course of fractionated prostate radiotherapy may not be insignificant and may need to be accounted for in the planning margin design. A consequence of these results is that use of highly reduced planning margins must be viewed with caution.

60 APPLIED LIFE SCIENCES↗

Prostate-Specific Natural Health Products (Dietary Supplements) Radiosensitize Normal Prostate Cells

Purpose: Prostate-specific health products (dietary supplements) are taken by cancer patients to alleviate the symptoms linked with poor prostate health. However, the effect of these agents on evidence-based radiotherapy practice is poorly understood. The present study aimed to determine whether dietary supplements radiosensitized normal prostate or prostate cancer cell lines. Methods and Materials: Three well-known prostate-specific dietary supplements were purchased from commercial sources available to patients (Trinovin, Provelex, and Prostate Rx). The cells used in the study included normal prostate lines (RWPE-1 and PWR-1E), prostate tumor lines (PC3, DU145, and LNCaP), and a normal nonprostate line (HaCaT). Supplement toxicity was assessed using cell proliferation assays [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide] and cellular radiosensitivity using conventional clonogenic assays (0.5-4Gy). Cell cycle kinetics were assessed using the bromodeoxyuridine/propidium iodide pulse-labeling technique, apoptosis by scoring caspase-3 activation, and DNA repair by assessing gammaH2AX. Results: The cell growth and radiosensitivity of the malignant PC3, DU145, and LNcaP cells were not affected by any of the dietary prostate supplements (Provelex [2mug/mL], Trinovin [10mug/mL], and Prostate Rx [50 mug/mL]). However, both Trinovin (10mug/mL) and Prostate Rx (6mug/mL) inhibited the growth rate of the normal prostate cell lines. Prostate Rx increased cellular radiosensitivity of RWPE-1 cells through the inhibition of DNA repair. Conclusion: The use of prostate-specific dietary supplements should be discouraged during radiotherapy owing to the preferential radiosensitization of normal prostate cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate and seminal vesicle volume based consideration of prostate cancer patients for treatment with 3D-conformal or intensity-modulated radiation therapy

Purpose: The purpose of this article was to determine the suitability of the prostate and seminal vesicle volumes as factors to consider patients for treatment with image-guided 3D-conformal radiation therapy (3D-CRT) or intensity-modulated radiation therapy (IMRT), using common dosimetry parameters as comparison tools. Methods: Dosimetry of 3D and IMRT plans for 48 patients was compared. Volumes of prostate, SV, rectum, and bladder, and prescriptions were the same for both plans. For both 3D and IMRT plans, expansion margins to prostate+SV (CTV) and prostate were 0.5 cm posterior and superior and 1 cm in other dimensions to create PTV and CDPTV, respectively. Six-field 3D plans were prepared retrospectively. For 3D plans, an additional 0.5 cm margin was added to PTV and CDPTV. Prescription for both 3D and IMRT plans was the same: 45 Gy to CTV followed by a 36 Gy boost to prostate. Dosimetry parameters common to 3D and IMRT plans were used for comparison: Mean doses to prostate, CDPTV, SV, rectum, bladder, and femurs; percent volume of rectum and bladder receiving 30 (V30), 50 (V50), and 70 Gy (V70), dose to 30% of rectum and bladder, minimum and maximum point dose to CDPTV, and prescription dose covering 95% of CDPTV (D95). Results: When the data for all patients were combined, mean dose to prostate and CDPTV was higher with 3D than IMRT plans (P<0.01). Mean D95 to CDPTV was the same for 3D and IMRT plans (P>0.2). On average, among all cases, the minimum point dose was less for 3D-CRT plans and the maximum point dose was greater for 3D-CRT than for IMRT (P<0.01). Mean dose to 30% rectum with 3D and IMRT plans was comparable (P>0.1). V30 was less (P<0.01), V50 was the same (P>0.2), and V70 was more (P<0.01) for rectum with 3D than IMRT plans. Mean dose to bladder was less with 3D than IMRT plans (P<0.01). V30 for bladder with 3D plans was less than that of IMRT plans (P<0.01). V50 and V70 for 3D plans were the same for 3D and IMRT plans (P>0.2). Mean dose to femurs was more with 3D than IMRT plans (P<0.01). For a given patient, mean dose and dose to 30% rectum and bladder were less with 3D than IMRT plans for prostate or prostate+SV volumes <65 (38/48) and 85 cm{sup 3} (39/48), respectively (P<0.01). The larger the dose to rectum or bladder with 3D plans, the larger also was the dose to these structures with IMRT (P<0.001). For both 3D and IMRT plans, dose to rectum and bladder increased with the increase in the volumes of prostate and seminal vesicles (P<0.02 to 0.001). Conclusions: Volumes of prostate and seminal vesicles provide a reproducible and consistent basis for considering patients for treatment with image-guided 3D or IMRT plans. Patients with prostate and prostate+SV volumes <65 and 85 cm{sup 3}, respectively, would be suitable for 3D-CRT. Patients with prostate and prostate+SV volumes >65 and 85 cm{sup 3}, respectively, might get benefit from IMRT.

60 APPLIED LIFE SCIENCES↗

Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Pretreatment Prostate Volume on Severe Acute Genitourinary Toxicity in Prostate Cancer Patients Treated With Intensity-Modulated Radiation Therapy

Purpose: To assess the impact of pretreatment prostate volume on the development of severe acute genitourinary toxicity in patients undergoing intensity-modulated radiation therapy (IMRT) for prostate cancer. Methods and Materials: Between 2004 and 2007, a consecutive sample of 214 patients who underwent IMRT (75.6 Gy) for prostate cancer at two referral centers was analyzed. Prostate volumes were obtained from computed tomography scans taken during treatment simulation. Genitourinary toxicity was defined using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 3.0 guidelines. Acute toxicity was defined as any toxicity originating within 90 days of the completion of radiation therapy. Patients were characterized as having a small or large prostate depending on whether their prostate volume was less than or greater than 50 cm{sup 3}, respectively. Genitourinary toxicity was compared in these groups using the chi-square or Fisher's exact test, as appropriate. Bivariate and multivariate logistic regression analysis was performed to further assess the impact of prostate volume on severe (Grade 3) acute genitourinary toxicity. Results: Patients with large prostates (>50 cm{sup 3}) had a higher rate of acute Grade 3 genitourinary toxicity (p = .02). Prostate volume was predictive of the likelihood of developing acute Grade 3 genitourinary toxicity on bivariate (p = .004) and multivariate (p = .006) logistic regression. Every 27.0 cm{sup 3} increase in prostate volume doubled the likelihood of acute Grade 3 genitourinary toxicity. Conclusions: Patients with larger prostates are at higher risk for the development of severe acute genitourinary toxicity when treated with IMRT for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-17: Intra-Fractional Prostate Movement Correction During Treatment Delivery Period for Prostate Cancer Using the Intra-Fractional Orthogonal KV-MV Image Pairs

Purpose: To evaluate the intra-fractional prostate movement range during the beam delivery and implement new IGRT method to correct the prostate movement during the hypofractionated prostate treatment delivery. Methods: To evaluate the prostate internal motion range during the beam delivery, 11 conventional treatments were utilized. Two-arc RapidArc plans were used for the treatment delivery. Orthogonal KV imaging is performed in the middle of the treatment to correct intra-fractional prostate movement. However, it takes gantry-mounted on-board imaging system relative long time to finish the orthogonal KV imaging because of gantry rotation. To avoid gantry movement and accelerate the IGRT processing time, orthogonal KV-MV image pair is tested using the OBI daily QA Cube phantom. Results: The average prostate movement between two orthogonal KV image pairs was 0.38cm (0.20cm ∼ 0.85cm). And the interval time between them was 6.71 min (4.64min ∼ 9.22 min). 2-arc beam delivery time is within 3 minutes for conventional RapidArc treatment delivery. Hypofractionated treatment or SBRT need 4 partial arc and possible non-coplanar technology, which need much longer beam delivery time. Therefore prostate movement might be larger. New orthogonal KV-MV image pair is a new method to correct the prostate movement in the middle of the beam delivery if real time tracking method is not available. Orthogonal KV-MV image pair doesn’t need gantry rotation. Images were acquired quickly which minimized possible new prostate movement. Therefore orthogonal KV-MV image pair is feasible for IGRT. Conclusion: Hypofractionated prostate treatment with less PTV margin always needs longer beam delivery time. Therefore prostate movement correction during the treatment delivery is critical. Orthogonal KV-MV imaging pair is efficient and accurate to correct the prostate movement during treatment beam delivery. Due to limited fraction number and high dose per fraction, the MV imaging dose is negligible.

60 APPLIED LIFE SCIENCES↗

A Preliminary Analysis of Calcifying Particles in the Serum and Prostates of Patients with Prostatic Inflammation

Chronic diseases of the prostate such as benign prostatic hyperplasia (BPH) & chronic pelvic pain syndrome (CPPS) have associated findings of chronic inflammation, despite a lack of causal relationship. Numerous attempts to define an infectious agent responsible for the clinical findings have been inconsistent. The possibility of an infectious agent, that has not been uncovered with routine culturing methods, forms the basis for this study. Serum from 940 healthy Finnish men were compared with serum from 40 Crohn's, 40 path dx prostatitis, & 40 with path dx carcinoma, using an enzyme-linked immunosorbant assay (ELISA), to detect antigens specific to Nanobacteria(NB) utilizing monoclonal antibodies (Ab) 5/3 and 8D10. This ELISA has not been validated for detecting NB-associated with clinical prostatic disease, yet cross-reactivity with other bacterial species is low. Immunohistochemistry was performed on de-paraffinized prostatic tissue slides, de-calcified with EDTA and stained with the DAKO Catalyzed Signal Amplification kit, employing 8D10 as the primary (target/antigen-detecting) Ab. The mean (plus or minus SD) & median concentrations of NB antigen (U/50 L) were 379.59 (plus or minus 219.28) & 640.00 for patients with prostatitis (BPH) vs 3.31 (plus or minus 3.55) & 2.94 for prostate adenocarcinoma, 1.88 (plus or minus 2.94) & 0.80 for Crohn's disease, & 7.43 (plus or minus 25.57) & 0.00 for patients with no clinical prostatic disease. Unpaired t-tests revealed statistically significant differences between the prostatitis (BPH) sera & each of the other groups with p less than 0.005, but no differences between the other groups themselves. Preliminary studies with immunohistochemistry & 3-D confocal microscopy reveal 16/24 tissue sections + for NB Ag in BPH vs. only 2/22 tissue sections with prostate cancer. The preliminary findings of this serum screening study suggest that NB antigen may be commonly found in the serum of patients with the pathological diagnosis of prostatitis. Preliminary immunohistologic studies, suggest that NB may be found within the gland itself at a higher rate in patients with BPH relative to patients with adenocarcinoma, however confirmatory studies with a more specific ELISA technique, primary cultures, & with larger numbers of patients in a prospective design are required to determine if 1) NB are a causative organism for clinical hyperplastic and inflammatory disease, & if 2) serological testing can be used to discriminate patients with nanobacterial-associated prostatic disease.

Jones, Jeffrey A.↗

Acute Urinary Retention After I-125 Prostate Brachytherapy in Relation to Dose in Different Regions of the Prostate

Purpose: To assess the influence of dose in different prostate regions, and the influence of anatomic variation on the risk of acute urinary retention (AUR) after I-125 prostate brachytherapy. Methods and Materials: In this case-control study, dosimetry and anatomy were compared between 50 patients with AUR (cases) and 50 patients without AUR (controls). Cases and controls were randomly selected from our database. The following structures were delineated on magnetic resonance imaging: prostate, urethra, peripheral zone, transitional zone, apex, base, midprostate, lower sphincter, and bladder neck. The dosimetric parameters analyzed were D{sub 10}, D{sub 50}, D{sub 90}, V{sub 100}, V{sub 150}, and V{sub 200}. The anatomic parameters analyzed were prostate protrusion into the bladder, bladder overlap, urethra angle, and urethra-bladder angle. The delineator was blinded to the patient's AUR status. Logistic regression analysis was used to investigate the association of these factors with AUR. Results: The dose delivered to different regions of the prostate was not significantly associated with the risk of AUR. Only dose to the bladder neck was significantly associated with AUR (odds ratio 1.13 per 10 Gy; 95% CI 1.02;1.26; p = 0.023). Mean bladder neck D{sub 90} was 65 Gy in AUR cases vs. 56 Gy in controls (p = 0.016), and mean bladder neck D{sub 10} was 128 Gy vs. 107 Gy, respectively (p = 0.018). Furthermore, on univariate analysis, a larger extent of both bladder overlap and of prostate protrusion were associated with a higher risk of AUR (odds ratio 1.16; 95% CI 1.04-1.28; p = 0.005, and odds ratio 1.83; 95% CI 1.37-2.45; p < 0.001, respectively). The mean extent of prostate protrusion was 3.5 mm in AUR cases vs. 1.0 mm in controls (p < 0.001). Odds ratios did not change substantially after adjustment for potential confounders. On multivariate analysis, the extent of prostate protrusion seemed to be a stronger risk factor for AUR than bladder overlap. Conclusion: The risk of AUR is not associated with dose delivered to different regions of the prostate. However, a higher dose to the bladder neck and a larger extent of prostate protrusion into the bladder are risk factors for the development of AUR after I-125 prostate brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Importance of Small Prostate Size in Men Receiving Definitive Prostate Brachytherapy

Purpose: To assess whether small prostate size is an adverse prognostic factor in men undergoing brachytherapy in the same manner in which it seems to be for men undergoing radical prostatectomy. Methods and Materials: From April 1995 to June 2008, 2024 patients underwent brachytherapy by a single brachytherapist. Median follow-up was 7.4 years. The role of small prostate size ({<=}20 cm{sup 3}) as a prognostic factor for biochemical progression-free survival, cause-specific survival, and all-cause mortality was investigated. The differences in survival between men with small and larger prostates were compared using Kaplan-Meier curves and log-rank tests. Results: Median prostate size for the entire cohort was 32.7 cm{sup 3}. For the 167 men with small prostates, median prostate size was 17.4 cm{sup 3}. There was no difference in biochemical progression-free survival (95.2% vs 96.2%, P=.603), cause-specific survival (97.7% vs 98.3%, P=.546), or all-cause mortality (78.0% vs 77.2%, P=.838) at 10 years for men with small prostates compared with men with larger prostates. On univariate and multivariate analysis, small prostate size was not associated with any of the primary outcome measures. Conclusion: Men with small prostates treated with brachytherapy have excellent outcomes and are at no higher risk of treatment failure than men with larger glands. High-quality implants with adequate margins seem sufficient to address the increased adverse risk factors associated with small prostate size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Prostatic Artery Embolization on the Dynamic Component of Benign Prostate Hyperplasia as Assessed by Ultrasound Elastography: A Pilot Series

Purpose: To determine the effects of prostatic artery embolization (PAE) on prostatic elasticity as assessed by Ultrasound Elastography (US-E), as well as to describe the feasibility and role of US-E as a novel tool in both pre- and post-PAE evaluation. Materials and Methods: This is a prospective, single-center investigation that included eight patients undergoing PAE for treatment of lower urinary tract symptoms (LUTS) attributed to benign prostate hyperplasia (BPH). Baseline and 3-month follow-up evaluations were performed and included prostate-specific antigen (PSA), uroflowmetry, pelvic magnetic resonance imaging and clinical assessment using the International Prostate Symptom Score (IPSS) questionnaire and the IPSS-Quality of life (QoL) item. US-E with measurement of the prostatic Elastic Modulus (EM) was performed before PAE and at 1-month follow-up. Results: After PAE, US-E showed a significant reduction of prostatic EM as assessed in kPa (33.14 vs. 47.24, − 29.8%, p = 0.002) and in m/s (3.75 vs. 4.63, − 19.0%, p < 0.001). Also, the transitional/peripheral zone ratio was significantly reduced by 45.36% (0.53 vs. 0.97, p < 0.05). All eight patients presented with significant LUTS improvement after PAE (p < 0.05 for IPSS, QoL, prostate volume, peak urinary flow rate and PSA). Conclusions: Findings described in this study suggest that PAE significantly reduces prostatic EM, leading to a positive effect on BPH dynamic component related to prostatic elasticity. Also, it features US-E as an additional tool for pre- and post-PAE evaluation, describing a novel indication for this technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiographic and Anatomic Basis for Prostate Contouring Errors and Methods to Improve Prostate Contouring Accuracy

Purpose: Use of highly conformal radiation for prostate cancer can lead to both overtreatment of surrounding normal tissues and undertreatment of the prostate itself. In this retrospective study we analyzed the radiographic and anatomic basis of common errors in computed tomography (CT) contouring and suggest methods to correct them. Methods and Materials: Three hundred patients with prostate cancer underwent CT and magnetic resonance imaging (MRI). The prostate was delineated independently on the data sets. CT and MRI contours were compared by use of deformable registration. Errors in target delineation were analyzed and methods to avoid such errors detailed. Results: Contouring errors were identified at the prostatic apex, mid gland, and base on CT. At the apex, the genitourinary diaphragm, rectum, and anterior fascia contribute to overestimation. At the mid prostate, the anterior and lateral fasciae contribute to overestimation. At the base, the bladder and anterior fascia contribute to anterior overestimation. Transition zone hypertrophy and bladder neck variability contribute to errors of overestimation and underestimation at the superior base, whereas variable prostate-to-seminal vesicle relationships with prostate hypertrophy contribute to contouring errors at the posterior base. Conclusions: Most CT contouring errors can be detected by (1) inspection of a lateral view of prostate contours to detect projection from the expected globular form and (2) recognition of anatomic structures (genitourinary diaphragm) on the CT scans that are clearly visible on MRI. This study shows that many CT prostate contouring errors can be improved without direct incorporation of MRI data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗