Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER EQUIVALENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A reconsideration of the noise equivalent power and the data analysis procedure for the infrared imaging video bolometers

The infrared imaging video bolometer (IRVB) used for measurement of the two-dimensional (2D) radiation profiles from the Large Helical Device has been significantly upgraded recently to improve its signal to noise ratio, sensitivity, and calibration, which ultimately provides quantitative measurements of the radiation from the plasma. The reliability of the quantified data needs to be established by various checks. The noise estimates also need to be revised and more realistic values need to be established. It is shown that the 2D heat diffusion equation can be used for estimating the power falling on the IRVB foil, even with a significant amount of spatial variation in the thermal diffusivity across the area of the platinum foil found experimentally during foil calibration. The equation for the noise equivalent power density (NEPD) is re-derived to include the errors in the measurement of the thermophysical and the optical properties of the IRVB foil. The theoretical value estimated using this newly derived equation matches closely, within 5.5%, with the mean experimental value. The change in the contribution of each error term of the NEPD equation with rising foil temperature is also studied and the blackbody term is found to dominate the other terms at elevated operating temperatures. The IRVB foil is also sensitive to the charge exchange (CX) neutrals escaping from the plasma. The CX neutral contribution is estimated to be marginally higher than the noise equivalent power (NEP) of the IRVB. It is also established that the radiation measured by the IRVB originates from the impurity line radiation from the plasma and not from the heated divertor tiles. The change in the power density due to noise reduction measures such as data smoothing and averaging is found to be comparable to the IRVB NEPD. The precautions that need to be considered during background subtraction are also discussed with experimental illustrations. Finally, the analysis algorithm with all the improvements is validated and found to reproduce the input power well within 10% accuracy. This article answers many fundamental questions relevant to the IRVB and illustrates the care to be exercised while processing the IRVB data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute response and noise equivalent power of cyclotron resonance-assisted InSb detectors at submillimeter wavelengths

Spectra are presented of the responsivity and noise equivalent power (NEP) of liquid-helium-cooled InSb detectors as a function of magnetic field in the range 20-110 per cm. The measurements are all made using a Fourier transform spectrometer with thermal sources. The results show a discernable peak in the detector response at the conduction electron cyclotron resonance (CCR) frequency for magnetic fields as low as 3 kG. The magnitude of responsivity at the resonance peaks is roughly constant with magnetic field and is comparable to the low-frequency hot-electron bolometer response. The NEP at the peaks is found to be comparable to the best long wavelength results previously reported. For example, NEP = 4.5 x 10 to the 13th W/(square root of Hz) at 4.2 K, 6 kG, and 40 per cm was measured. The InSb CCR will provide a much improved detector for laboratory spectroscopy, as compared with hot electron bolometers, in the 20-100 per cm range.

Brown, E. R.↗

Equivalence of optical and electrical noise equivalent power of hybrid NbTiN-Al microwave kinetic inductance detectors

We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on the resonance feature of hybrid MKIDs. We determine an electrical noise equivalent power (NEP) from the measured temperature responsivity, quasiparticle recombination time, superconducting transition temperature, and noise spectrum, all of which can be measured in a dark environment. For the two hybrid NbTiN-Al MKIDs studied in detail, the electrical NEP is within a factor of two of the optical NEP, which is measured directly using a blackbody source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanobolometer with ultralow noise equivalent power

Since the introduction of bolometers more than a century ago, they have been used in various applications ranging from chemical sensors, consumer electronics, and security to particle physics and astronomy. However, faster bolometers with lower noise are of great interest from the fundamental point of view and to find new use-cases for this versatile concept. We demonstrate a nanobolometer that exhibits roughly an order of magnitude lower noise equivalent power, 20 zW / $\sqrt{Hz}$, than previously reported for any bolometer. Importantly, it is more than an order of magnitude faster than other low-noise bolometers, with a time con- stant of 30 μs at 60 zW / $\sqrt{Hz}$. These results suggest a calorimetric energy resolution of 0.3 zJ = h × 0.4 THz with a time constant of 30 μs. Further development of this nanobolometer may render it a promising candidate for future applications requiring extremely low noise and high speed such as those in quantum technology and terahertz photon counting.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MCT Avalanche Photodiode Detector for Two-Micron Active Remote Sensing Applications

Mercury Cadmium Telluride electron initiated avalanche photodiodes demonstrated a breakthrough in lidar active remote sensing technology. A lidar detection system, based on an array of these devices, was integrated and characterized for 2-μm applications. Characterization experiments were focused on evaluating the dark current, gain and responsivity variations with bias voltage. Quantum efficiency and input dynamic range including noise-equivalent-power and maximum detectable power, were calculated from these results. Operating the detection system using four pixels at 77.6 K, 12 V bias resulted in a current responsivity of 615.8 A/W and a voltage responsivity of 1.45 GV/W. Minimum detectable power of 14 pW was obtained, which is equivalent to 5.7 fW/Hz(exp 1/2) noise-equivalent-power, indicating an average noise-equivalent-power of 1.4 fW/Hz(exp 1/2) per pixel. Work is in progress to integrate and validate this detection system using a newly developed triple-pulse integrated path differential absorption lidar for simultaneous and independent atmospheric measurements of water vapor and carbon dioxide.

Refaat, Tamer F.↗

Signal-to-noise ratios of multiplexing spectrometers in high backgrounds

Signal-to-noise ratios and the amount of multiplexing gain achieved with a Michelson spectrometer during detector and background noise are studied. Noise caused by the warm background is found in 10 and 20-micron atmospheric windows in high resolution Fourier spectroscopy. An equation is derived for the signal-to-noise ratio based on the number of channels, total time to obtain the complete spectrum, the signal power in one spectral element, and the detector noise equivalent power in the presence of negligible background. Similar expressions are derived for backgrounds yielding a noise equivalent power to a spectral element, and backgrounds having flat spectra in the frequency range under investigation.

Knacke, R. F.↗

Anomalous response of superconducting titanium nitride resonators to terahertz radiation

We present an experimental study of kinetic inductance detectors (KIDs) fabricated of atomic layer deposited TiN films and characterized at radiation frequencies of 350 GHz. The responsivity to radiation is measured and found to increase with the increase in radiation powers, opposite to what is expected from theory and observed for hybrid niobium titanium nitride/aluminium (NbTiN/Al) and all-aluminium (all-Al) KIDs. The noise is found to be independent of the level of the radiation power. The noise equivalent power improves with higher radiation powers, also opposite to what is observed and well understood for hybrid NbTiN/Al and all-Al KIDs. We suggest that an inhomogeneous state of these disordered superconductors should be used to explain these observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dry in-pile fracture test (DRIFT) for separate-effects validation of ceramic fuel fracture models

Fracture is an important component of nuclear fuel behavior, and significant efforts have been invested into developing fuel performance models that are capable of accurately representing fracture. Usable data on the process of fracture propagation in nuclear fuel under realistic service conditions are very limited. To address this need, a series of separate-effects experiments were developed and performed at Idaho National Laboratory's Transient Reactor Test (TREAT) facility. These experiments employ a heat sink to radially remove heat from the fuel in a manner that approximates the effect of coolant in an operating light-water reactor (LWR). The test holder for these experiments is known as the Dry In-pile Fracture Test (DRIFT). A series of experiments employing DRIFT and TREAT were performed to provide data on the extent and nature of fracture in fresh fuel at various points during a ramp to full power. Novel aspects of these experiments include the way they employ a heat sink to replicate steady-state LWR conditions, as well as the use of fiber optic sensors for in-reactor thermal instrumentation. Details on the development of this experiment, experimental conditions, and resulting data (including in situ thermal measurements and post-irradiation imaging of fracture) are provided in this work. LWR-equivalent powers ranging from 10 to 25 kW/m were tested using this apparatus. Cracking was visible at all power levels, with increasing cracking extent as the power level increased, although there was little difference in the cracking between the two highest-power tests, which had LWR-equivalent powers of 20 and 25 kW/m.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IR detectors - Heterodyne and direct

Recent developments in the area of wide-bandwidth infrared detectors, both for direct and heterodyne detection, are reviewed with emphasis on the differences and tradeoffs between photodiodes and photoconductors. In the direct-detection mode, where amplifier noise is an important consideration, the state-of-the-art detection noise equivalent power is approximated by 500 (B/10 MHz) pW. At short wavelengths (less than 1.7 micron), avalanche photodiodes offer superior performance, with a detection noise equivalent power of about 50 (B/10 MHz) pW. In heterodyne operation, near-ideal sensitivities of about 0.3 (B/10 MHz) pW have been achieved with 77K photodiodes. At 10 microns, HgCdTe photoconductors offer very good heterodyne performance at elevated temperatures: 2 (B/10 MHz) pW at 195 K and potentially 3 (B/10 MHz) pW at 250 K.

Spears, D. L.↗

Some n-p (Hg,Cd)Te photodiodes for 8-14 micrometer heterodyne applications

The results describing the dc and CO2 laser heterodyne characteristics of a three element photodiode array and single element and four element photodiode arrays are presented. The measured data shows that the n(+)-p configuration is capable of achieving bandwidths of 475 to 725 MHz and noise equivalent powers of 3.2 x 10 to the minus 20th power W/Hz at 77 K and 1.0 x 10 to the minus 19th power W/Hz at 145 K. The n(+)-n(-)-p photodiodes exhibited wide bandwidths (approximately 2.0 GHz) and fairly good effective heterodyne quantum efficiencies (approximately 13-30 percent at 2.0 GHz). Noise equivalent powers ranging from 1.44 x 10 to the minus 19th power W/Hz to 6.23 x 10 to the minus 20th power W/Hz were measured at 2.0 GHz.

Shanley, J. F.↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Preliminary design of a tangentially viewing imaging bolometer for NSTX-U

The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm{sup 2} for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-sensitivity receiver for infrared laser communications.

Description of a high-sensitivity wide-bandwidth 10.6-micron heterodyne receiver for space and ground operational use. The receiver includes a cooled HgCdTe infrared mixer diode, a conical scanner for spatial tracking, an acquisition channel for spatial search and station alignment, and an automatic frequency-control channel to maintain a fixed laser frequency offset. The infrared mixer is designed to provide nearly quantum-noise-limited operation over an extended range of mixer temperature, bias voltage, and intermediate frequency. The resultant experimental receiver has a measured noise equivalent power of less than 10 to the minus 19th W/Hz over the 15- to 40-MHz i.f. band for mixer temperatures from 85 to 115 K, and less than 2 x 10 to the minus 19th W/Hz up to 140 K. Mixer 3-dB cutoff frequencies as high as 420 MHz were measured at a mixer temperature of 125 K. An analysis and engineering equations are given for receiver noise components, noise equivalent power, available mixer conversion gain, mixer transducer gain, and quantum-noise factor in terms of such factors as mixer parameters, quantum efficiency, mixer temperature, dynamic conductance, bias voltage, local oscillator power, and i.f. amplifier characteristics.

Peyton, B. J.↗

Progress on Background-Limited Membrane-Isolated TES Bolometers for Far-IR/Submillimeter Spectroscopy

To determine the lowest attainable phonon noise equivalent power (NEP) for membrane-isolation bolometers, we fabricated and measured the thermal conductance of suspended Si3N4 beams with different geometries via a noise thermometry technique. We measured beam cross-sectional areas ranging from 0.35 x 0.5 (micro)m(sup 2) to 135 x 1.0 (micro)m(sup 2) and beam lengths ranging from (micro)m to 8300 (micro)m. The measurements directly imply that membrane-isolation bolometers are capable of reaching a phonon noise equivalent power (NEP) of 4 x 10(sup -20)W/Hz(sup 1)/O . This NEP adequate for the Background-Limited Infrared-Submillimeter Spectrograph (BLISS) proposed for the Japanese SPICA observatory, and adequate for NASA's SAFIR observatory, a 10-meter, 4 K telescope to be deployed at L2. Further, we measured the heat capacity of a suspended Si 3N 4 membrane and show how this result implies that one can make membrane-isolation bolometers with a response time which is fast enough for BLISS.

submillimeter spectrometer↗

Broadband Solenoidal Haloscope for Terahertz Axion Detection

We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [ 10 - 3 , 1 ] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m 2 barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires < 10 - 20 W / Hz sensor noise equivalent power with a 10 T solenoid and 10 m 2 barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.

Liu, Jesse↗