Capacitance-coupled wiper increases potentiometer life

Capacitively-coupled wiper reduces the friction between the sliding contact and the potentiometer element in conventional potentiometers. A small preamplifier employed close to the wiper reduces errors caused by output cable capacitance. The device is friction free with resultant low wear and has high speed and high resolution.

Dimeff, J.

Potentiometer, constant tension and lubrication device

Wiper assembly is described for feedback potentiometers which provides self cleaning, self lubrication, and tension within controlled limits. Each end of the assembly contains loose fitting leather pad thoroughly soaked in wiper lubricating fluid. Cleaning and lubrication of potentiometer resulting from use of lubrication soaked leather accomplishes noise free operation.

Smith, H. J.

Ganged series potentiometer mixer networks

A ganged potentiometer with the interesting property of a constant 10k ohm or greater series impedance for all rotations of the shaft was rediscovered. The device provided a versatile passive mixer circuit when used with most signal sources and can be used as a variable series input summing resistor in operational amplifier networks. The potentiometer gave simple solutions to missing problems with a single control knob.

Burhans, R. W.

Eroding Potentiometers

Eroding potentiometers have been devised for measuring the time-dependent positions of char fronts advancing through layers of insulating material subject to intense heating from one side. In the original application, the material layers of interest are thermal insulators in rocket motors and the heat comes from firing of the motors, but the principle of operation is equally applicable to other insulating materials subject to intense heating (e.g., ablative fire-retardant materials). Measuring the thickness decrement of propellant (in hybrid motors in particular) is another possible application of this transducer. Telemetry informs mission control of the propellant left after each burn. An eroding potentiometer could be characterized, more precisely, as an eroding two-wire resistor. It includes a twisted pair of thin, insulated wires oriented along the thickness of, and embedded in, the layer of thermal-insulation material to be tested (see figure). The electrical insulation material on the wires should be one for which the charring temperature is about the same as (or perhaps slightly less than) that of the thermal- insulation material to be tested. In the original rocket-motor application, the wires have a diameter of 0.003 in. (.0.08 mm), are made of manganin, and are coated with polyimide for electrical insulation. Outside the thermal insulation on the cold side, the wire leads are connected to a Wheatstone bridge circuit for measurement of electrical resistance change.

Eggett, Mark

String Potentiometers for Supersonic Split-Line Thrust Vector Amplification Factor Verification

The static fire of NASA’s Mars Ascent Vehicle (MAV) first stage Solid Rocket Motor (SRM1) Demonstration Motor-1 (DM-1) occurred at Edwards Air Force Base (AFB) on April 7, 2023. Among other objectives, this test successfully demonstrated the Thrust Vector Control (TVC) system, including the Technology Readiness Level (TRL) of the Supersonic Split-Line (SSSL) nozzle. An essential characteristic of the SSSL is the thrust vector amplification factor (TVAF) it exhibits; however, empirically quantifying this behavior is difficult due to the limitations of measuring the internal nozzle gas dynamics of a Solid Rocket Motor (SRM) during burn. Using four string potentiometers mounted inside the test chamber connected to the nozzle and motor case and a thrust measurement system (TMS), the TVAF can be derived from the known nozzle and motor geometry. Increasing the accuracy of the TVAF is essential for certain groups working on the MAV including the Guidance, Navigation, and Control (GN&C) group, who prior to DM-1, solely relied on Computational Fluid Dynamics (CFD) data in their Monte Carlo simulations for TVAF. The methodology shown in this paper can be generally applied to any test article implementing a SSSL nozzle, presuming string potentiometers are a viable option and the facility is conducive of their implementation.

Supersonic Split-Line

Mars Exploration Rover potentiometer problems, failures and lessons learned

During qualification testing of three types of nonwire-wound precision potentiometers for the Mars Exploration Rover, a variety of problems and failures were encountered. This paper will describe some of the more interesting problems, detail their investigations and present their final solutions. The failures were found to be caused by design errors, manufacturing errors, improper handling, test errors, and carelessness. A trend of decreasing total resistance was noted, and a resistance histogram was used to identify an outlier. A gang fixture is described for simultaneously testing multiple pots, and real time X-ray imaging was used extensively to assist in the failure analyses. Lessons learned are provided.

potentiometer

A Multiple-range Self-balancing Thermocouple Potentiometer

A multiple-range potentiometer circuit is described that provides automatic measurement of temperatures or temperature differences with any one of several thermocouple-material pairs. Techniques of automatic reference junction compensation, span adjustment, and zero suppression are described that permit rapid selection of range and wire material, without the necessity for restandardization, by setting of two external tap switches.

INSTRUMENTS, LABORATORY

Mars Exploration Rover Potentiometer Problems, Failures and Lessons Learned

During qualification testing of three types of non-wire-wound precision potentiometers for the Mars Exploration Rover, a variety of problems and failures were encountered. This paper will describe some of the more interesting problems, detail their investigations and present their final solutions. The failures were found to be caused by design errors, manufacturing errors, improper handling, test errors, and carelessness. A trend of decreasing total resistance was noted, and a resistance histogram was used to identify an outlier. A gang fixture is described for simultaneously testing multiple pots, and real time X-ray imaging was used extensively to assist in the failure analyses. Lessons learned are provided.

Balzer, Mark

Signal conditioner for potentiometer type transducers

Low cost method is described for signal conditioning of pot-type transducers utilizing printed circuitry. Conditioner fits into standard rack, accommodates 56 channels, and can be operated by one attendant.

Armentrout, E. C.