A Novel High Capacity Positive Electrode Material with Tunnel-Type Structure for Aqueous Sodium-Ion Batteries
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.
The energy levels and γ-ray decay scheme of the positive-parity states in the Tz=12 nucleus 67As have been studied by using the 40Ca(36Ar,2αp)67As reaction at a beam energy of 145 MeV. Two new band structures have been identified which can be connected to the previously known levels. The results for these bands are compared with configuration-dependent cranked Nilsson–Strutinsky calculations. The good level of agreement between theory and experiment suggests that these structures can be interpreted in terms of configurations that involve three g92 particles and that both possess noncollective terminating states.
Highlights: • APT measurement of Al/Cu alloy is simulated with a combined electrostatics and molecular dynamics (MD) approach. • Results show segregation of dilute Cu at [111] poles in correspondence to experimental measurements. • No temperature is involved. The effect originates in both disparate evaporation field and bond-energies in the alloy. While thermal or field-induced surface migration has been invoked often in past literature to rationalize the experimental observations of solute and impurity atoms segregation to specific poles and zones lines in atom probe tomography (APT) reconstructions, it does not satisfactorily explain all experimental results. Using a combined finite-element and molecular dynamics simulation approach that models the field evaporation process from mechanically relaxed emitter structures, we show that an additional mechanism, athermal relaxation, can also drive significant solute migration. The mechanism is illustrated for Cu in solid solution in Al, which exhibits segregation of Cu to 111 poles and along [110] zone lines in reconstructed APT data. The higher bonding energy of Cu atoms on the surface, confirmed using density-functional theory calculations, causes longer retention on the surface and preferential evaporation of neighboring Al atoms with subsequent athermal relaxation of Cu into higher-neighbor-count sites left vacant by evaporating Al neighbors. This in turn results in barrier-free long-range migration of the Cu atoms by a series of relaxation events that follow the receding terrace ledges towards high-neighbor count poles and zone lines. This mechanism fundamentally limits spatial resolution in the limit of zero temperature.
Purpose: Many cancer centers treat colorectal patients in the prone position on a belly board to minimize dose to the small bowel. That may potentially Result in patient setup instability with corresponding impact on dose delivery accuracy for highly conformal techniques such as IMRT/VMAT. Two aims of this work are 1) to investigate setup accuracy of rectum patients treated in the prone position on a belly board using CBCT and 2) to evaluate dosimetric impact on bladder and small bowel of treating rectum patients in supine vs. prone position. Methods: For the setup accuracy study, 10 patients were selected. Weekly CBCTs were acquired and matched to bone. The CBCT-determined shifts were recorded. For the dosimetric study, 7 prone-setup patients and 7 supine-setup patients were randomly selected from our clinical database. Various clinically relevant dose volume histogram values were recorded for the small bowel and bladder. Results: The CBCT-determined rotational shifts had a wide variation. For the dataset acquired at the time of this writing, the ranges of rotational setup errors for pitch, roll, and yaw were [−3.6° 4.7°], [−4.3° 3.2°], and [−1.4° 1.4°]. For the dosimetric study: the small bowel V(45Gy) and mean dose for the prone position was 5.6±12.1% and 18.4±6.2Gy (ranges indicate standard deviations); for the supine position the corresponding dose values were 12.9±15.8% and 24.7±8.8Gy. For the bladder, the V(30Gy) and mean dose for prone position were 68.7±12.7% and 38.4±3.3Gy; for supine position these dose values were 77.1±13.7% and 40.7±3.1Gy. Conclusion: There is evidence of significant rotational instability in the prone position. The OAR dosimetry study indicates that there are some patients that may still benefit from the prone position, though many patients can be safely treated supine.
On the basis of FluoroBancroft linear-algebraic method [S.B. Andersson, Opt. Exp. 16, 18714 (2008)] three highly-resolved positioning methods were proposed for wavelength-shifting fiber (WLSF) neutron detectors. Using a Gaussian or exponential-decay light-response function (LRF), the non-linear relation of photon-number profiles vs. x-pixels was linearized and neutron positions were determined. The proposed algorithms give an average 0.03-0.08 pixel position error, much smaller than that (0.29 pixel) from a traditional maximum photon algorithm (MPA). The new algorithms result in better detector uniformity, less position misassignment (ghosting), better spatial resolution, and an equivalent or better instrument resolution in powder diffraction than the MPA. Moreover, these characters will facilitate broader applications of WLSF detectors at time-of-flight neutron powder diffraction beamlines, including single-crystal diffraction and texture analysis.
Abstract We define and study the totally nonnegative part of the Chow quotient of the Grassmannian, or more simply the nonnegative configuration space . This space has a natural stratification by positive Chow cells , and we show that nonnegative configuration space is homeomorphic to a polytope as a stratified space. We establish bijections between positive Chow cells and the following sets: (a) regular subdivisions of the hypersimplex into positroid polytopes, (b) the set of cones in the positive tropical Grassmannian, and (c) the set of cones in the positive Dressian. Our work is motivated by connections to super Yang–Mills scattering amplitudes, which will be discussed in a sequel.
Purpose: The target volume for Whole Breast Irradiation (WBI) is dictated by location of tumor mass, breast tissue distribution, and involvement of lymph nodes. Dose coverage and Organs at Risk (OARs) sparing can be difficult to achieve in patients with unfavorable thoracic geometries. For these cases, inverse-planned and 3D-conformal prone treatments can be alternatives to traditional supine 3D-conformal plans. A dosimetric comparison can determine which of these techniques achieve optimal target coverage while sparing OARs. Methods: This study included simulation datasets for 8 patients, 5 of whom were simulated in both supine and prone positions. Positioning devices included breast boards and Vaclok bags for the supine position, and prone breast boards for the prone position. WBI 3-D conformal plans were created for patients simulated in both positions. Additional VMAT and IMRT WBI plans were made for all patients in the supine position. Results: Prone and supine 3D conformal plans had comparable PTV coverage. Prone 3D conformal plans received a significant 50% decrease to V20, V10, V5 and V30% for the ipsilateral lung in contrast to the supine plans. The heart also experienced a 10% decrease in maximum dose in the prone position, and V20, V10, V5 and V2 had significantly lower values than the supine plan. Supine IMRT and VMAT breast plans obtained comparable PTV coverage. The heart experienced a 10% decrease in maximum dose with inverse modulated plans when compared to the supine 3D conformal plan, while V20, V10, V5 and V2 showed higher values with inverse modulated plans than with supine 3D conformal plans. Conclusion: Prone 3D-conformal, and supine inverse planned treatments were generally superior in sparing OARs to supine plans with comparable PTV coverage. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions.
The synthesis and spectroscopic characterization of CpC5F4NFe(PtBu2NBn2)Cl, [3-Cl] (where C5F4N is the tetrafluorpyridyl substituent and PtBu2NBn2 = 1,5-di(tert-butyl)-3,7-di(benzyl)-1,5-diaza-3,7-diphosphacyclooctane) are reported. Complex 3-Cl and previously reported [CpC5F4NFe(PtBu2NtBu2)Cl], 4-Cl, are precursors to intermediates in the catalytic oxidation of H2, including CpC5F4NFe(PtBu2NBn2)H (3-H), CpC5F4NFe(PtBu2NtBu2)H (4-H), [CpC5F4NFe(PtBu2NBn2)]BArF4 ([3](BArF4), [CpC5F4NFe(PtBu2NtBu2)]BArF4 ([4](BArF4), [CpC5F4NFe(PtBu2NBn2)(H2)]BArF4 ([3-H2]BArF4), and [CpC5F4NFe(PtBu2NtBu2H)H]BArF4 ([4-FeH(NH)]BArF4). All of these complexes were characterized by spectroscopic and electrochemical studies; 3-Cl, 3-H and 4-Cl were also characterized by single crystal diffraction studies. 3-H and 4-H are electrocatalysts for H2 (1.0 atm) oxidation in the presence of a excess of the amine base N-methylpyrrolidine, with turnover frequencies at 22 °C of 2.5 s-1 and 0.5 s-1, and overpotentials at Ecat/2 of 235 mV and 95 mV, respectively. Studies of individual chemical and/or electrochemical reactions of the various intermediates provide important insights into the factors governing the overall catalytic activity for H2 oxidation, and provide important insights into the role of the pendant base of the [FeFe] hydrogenase active site. This work was supported by the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy.
The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.
Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.
Summary Understanding of microbial metal reduction is based almost solely on studies of G ram‐negative organisms. In this study, we focus on D esulfotomaculum reducens MI ‐1, a G ram‐positive metal reducer whose genome lacks genes with similarity to any characterized metal reductase. Using non‐denaturing separations and mass spectrometry identification, in combination with a colorimetric screen for chelated F e( III )‐ NTA reduction with NADH as electron donor, we have identified proteins from the D . reducens proteome not previously characterized as iron reductases. Their function was confirmed by heterologous expression in E scherichia coli . Furthermore, we show that these proteins have the capability to reduce soluble C r( VI ) and U ( VI ) with NADH as electron donor. The proteins identified are NADH : flavin oxidoreductase ( D red_2421) and a protein complex composed of oxidoreductase flavin adenine dinucleotide/ NAD ( P )‐binding subunit ( D red_1685) and dihydroorotate dehydrogenase 1B ( D red_1686). D red_2421 was identified in the soluble proteome and is predicted to be a cytoplasmic protein. D red_1685 and D red_1686 were identified in both the soluble as well as the insoluble protein fraction, suggesting a type of membrane association, although PSORTb predicts both proteins are cytoplasmic. This study is the first functional proteomic analysis of D . reducens and one of the first analyses of metal and radionuclide reduction in an environmentally relevant G ram‐positive bacterium.
Potential induced degradation of the polarization type (PID-p) can reduce module performance in a relatively short period of time. PID-p can occur at both voltage polarities, but most studies are focused on degradation under a negative bias. This paper uses commercial bifacial passivated emitter and rear contact (PERC) cells within a monofacial glass-backsheet module construction to evaluate the impact of PID-p under a positive bias on the front side. Using the aluminum-foil (Al-foil) method, the module was stressed for PID in an environmental chamber. After the stress, the maximum power (Pmax) showed a decline of 3.1% at 1000 W/m2 and 6.2% at 200 W/m2. Recovery under light was also investigated. Complete recovery was observed at high irradiance, while a partial recovery was seen at lower irradiance. The outcomes of this study can help in understanding PID-p degradation under a positive bias and its recovery under the light.
This work provides a detailed derivation of a generalized quantum Fokker-Planck equation (GQFPE) appropriate for photo-induced quantum dynamical processes. The path integral method pioneered by Caldeira and Leggett (CL) [Physica A 121, 587 (1983)] is extended by utilizing a nonequilibrium influence functional applicable to different baths for the ground and the excited electronic states. Both nonequilibrium and non-Markovian effects are accounted for consistently by expanding the paths in the exponents of the influence functional up to the second order with respect to time. This procedure results in approximations involving only single time integrations for the exponents of the influence functional but with additional time dependent boundary terms that have been ignored in previous works. The boundary terms complicate the derivation of a time evolution equation but do not affect position dependent physical observables or the dynamics in the steady state limit. For an effective density operator with the boundary terms factored out, a time evolution equation is derived, through short time expansion of the effective action and Gaussian integration in analytically continued complex domain of space. This leads to a compact form of the GQFPE with time dependent kernels and additional terms, which renders the resulting equation to be in the Dekker form [Phys. Rep. 80, 1 (1981)]. Major terms of the equation are analyzed for the case of Ohmic spectral density with Drude cutoff, which shows that the new GQFPE satisfies the positive definiteness condition in medium to high temperature limit. Steady state limit of the GQFPE is shown to approach the well-known expression derived by CL in the high temperature and Markovian bath limit and also provides additional corrections due to quantum and non-Markovian effects of the bath.
A method for achieving good position resolution of low-intensity electron signals using a microchannel plate resistive anode detector is demonstrated. Electron events at a rate of 7 counts s{sup −1} are detected using a Z-stack microchannel plate. The dependence of position resolution on both the distance and the potential difference between the microchannel plate and resistive anode is investigated. Using standard commercial electronics, a measured position resolution of 170 μm (FWHM) is obtained, which corresponds to an intrinsic resolution of 157 μm (FWHM)
Diamond X-ray detectors with conducting nitrogen-incorporated ultra-nanocrystalline diamond (N-UNCD) films as electrodes were fabricated to measure X-ray beam flux and position. Structural characterization and functionality tests were performed for these devices. The N-UNCD films grown on unseeded diamond substrates were compared with N-UNCD films grown on a seeded silicon substrate. Here, the feasibility of the N-UNCD films acting as electrodes for X-ray detectors was confirmed by the stable performance in a monochromatic X-ray beam. The fabrication process is able to change the surface status which may influence the signal uniformity under low bias, but this effect can be neglected under full collection bias.
Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source (APS). The next generation XBPMs for high heat load front ends (HHL FEs) have been designed to meet these requirements by utilizing Cu K-edge x-ray fluorescence (XRF) from a pair of copper absorbers and have been installed at the front ends (FEs) of the APS. Commissioning data showed a significant performance improvement over the existing photoemission-based XBPMs. While a similar design concept can be applied for the canted undulator front ends, where two undulator beams are separated by 1.0-mrad, the lower beam power (< 10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from the diamond blades placed edge-on to the x-ray beam. A prototype of the Compton scattering XBPM system was installed at 24-ID-A in May 2015. In this report, the design and test results for XRF-based XBPM and Compton scattering based XBPM are presented. Ongoing research related to the development of the next generation XBPMs on thermal contact resistance of a joint between two solid bodies is also discussed.