At least 19 records

Photon position measure

The positive operator valued measure (POVM) for a photon counting array detector is derived and found to equal photon flux density integrated over pixel area and measurement time. Since photon flux density equals number density multiplied by the speed of light, this justifies theoretically the observation that a photon counting array provides a coarse-grained measurement of photon position. The POVM obtained here can be written as a set of projectors onto a basis of localized states, consistent with the description of photon position in a recent quantum imaging proposal [Tsang, Phys. Rev. Lett. 102, 253601 (2009)]. The wave function that describes a photon counting experiment is the projection of the photon state vector onto this localized basis. Collapse is to the electromagnetic vacuum and not to a localized state, thus violating the textbook rules of quantum mechanics but compatible with the theory of generalized observables and the nonlocalizability of an incoming photon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contactless Position Measurement System for Remote Alignment of Highly Reflective Objects

The Contactless Position Measurement System (CPMS) permits automatic alignment of highly-reflecting components that cannot or should not be touched by human hands, such as those used in SRF cavities. CPMS also has application during maintenance of fusion reactors, when the components in the reactor are radioactive. The length of time for which humans can handle the components in order to carry out maintenance or repairs is limited. We would like to measure the relative positions of such objects so we can bring them into alignment with motorized stages, thus eliminating the need for human contact. The CPMS is a computer vision system that measures the location of highly reflective components to within a fraction of a millimeter by finding the edges of silhouette images. This is done by placing a uniform, infrared backlight behind the components, and viewing each component with two low-aberration, infrared cameras. Each of these stereoscopic cameras are located within a coordinate system we set up with reference platforms, light sources, and survey cameras distributed around the perimeter of the string assembly room, or fusion reactor. We obtain stereoscopic silhouette images of each component, and we use these to determine the position of the component within our string assembly coordinate system. The CPMS combines the silhouette images with knowledge of the dimensions of the objects to obtain the relative positions of components in its field of view. These position measurements then allow us to mechanically maneuver the components into contact. Once we know where they are, we can move the components to where they are supposed to be with motorized stages or other mechanical means, check they are in the right place, and bolt them together. In Phase I, we built a prototype infrared backlights and cameras, tested it, wrote an analysis program to fit the images. At a range of 50 cm, we are able to measure the relative positions of two stainless steel flanges with an accuracy of 150 μm rms. The next steps are to test the analysis program with motorized stages, build a full-size prototype, and implement it in an cleanroom with SRF cavity assembly. This can be done in a cost effective way given the materials with which the system is designed. As Open Source Instruments achieved more in Phase I than anticipated, despite not receiving a Phase II SBIR grant, we hope to move forward with product development and sales with a testing partner.

43 PARTICLE ACCELERATORS↗

Subwavelength position measurements with running-wave driving fields

Subwavelength position measurement of quantum particles is discussed. Our setup is based on a closed-loop driving-field configuration, which enforces a sensitivity of the particle dynamics to the phases of the applied fields. Thus, running wave fields are sufficient, avoiding limitations associated with standing-wave-based localization schemes. Reversing the directions of the driving laser fields switches between different magnification levels for the position determination. This allows us to optimize the localization, and at the same time eliminates the need for additional classical measurements common to all previous localization schemes based on spatial periodicity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-inductive vertical position measurements by Faraday-effect polarimetry on EAST tokamak

Vertical instability control in an elongated plasma is highly desirable for a tokamak reactor. A multi-channel 694 GHz far-infrared laser-based polarimeter-interferometer system has been used to provide a non-inductive vertical position measurement in the long-pulse EAST tokamak. A detailed comparison of vertical position measurements by polarimetry and external inductive flux loops has been used to validate Faraday-effect polarimetry as an accurate high-time response vertical position sensor.

47 OTHER INSTRUMENTATION↗

Maximal violation of Bell inequalities by position measurements

We show that it is possible to find maximal violations of the Clauser-Horne-Shimony-Holt (CHSH) Bell inequality using only position measurements on a pair of entangled nonrelativistic free particles. The device settings required in the CHSH inequality are done by choosing one of two times at which position is measured. For different assignments of the '+' outcome to positions, namely, to an interval, to a half-line, or to a periodic set, we determine violations of the inequalities and states where they are attained. These results have consequences for the hidden variable theories of Bohm and Nelson, in which the two-time correlations between distant particle trajectories have a joint distribution, and hence cannot violate any Bell inequality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton beam position measurement in air using a BPM

A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.

43 PARTICLE ACCELERATORS↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Non-inductive plasma vertical position measurement for the 1056 s discharge on EAST

Vertical position stability plays a crucial role in maintaining safe and reliable plasma operation for long-pulse fusion devices. In general, the vertical position is measured by using inductive magnetic coils installed inside the vacuum vessel; however, the integration drift effects are inherent for steady-state or long-pulse plasma operation. Further, developing a non-magnetic approach provides a fusion reactor-relevant steady-state solution that avoids the negative impact of integration drift. In this paper, we compare the non-inductively determined vertical position achieved by line-integrated interferometer and polarimeter measurements to that employing an inductive flux loop for a 1056 s discharge recently achieved on EAST (Experimental Advanced Superconducting Tokamak). Experimental results show that the non-inductive measurement is more robust than flux loops after 300 s if the integrator is not reset to suppress integrator drift. Real-time vertical position control using the non-inductive system is proposed for the next EAST experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New printed circuit boards magnetic coils in the vacuum vessel of J-TEXT tokamak for position measurement

Four sets of magnetic diagnostic coils, which are printed on machinable ceramic printed circuit boards (PCB), are designed, fabricated, installed, and tested in the Joint Texas Experimental Tokamak (J-TEXT) vacuum vessel for detecting the plasma radial and vertical displacements relative to the geometric center of the vacuum vessel in Ohmic discharges. Each coordinate is determined by a pair of variable cross-section Rogowski and saddle coils, which measure the tangential and normal magnetic fields (relative to the coil surface). These coils are suitable for mass production and offer advantages in vacuum compatibility and temperature tolerance that are important for J-TEXT. Position measurements using PCB coils are compared with those from soft x-ray image system and match the position well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NGEE Arctic Tram: Overview of Tram-mounted Instruments, Co-located Data, Measurement Position, Elevation and Polygon Characterization, Utqiagvik (Barrow), Alaska, 2014-2018

The NGEE-Arctic Tram operated from 2014 - 2018. It was installed on the Barrow Environmental Observatory in Barrow, Alaska in late May of 2014 and operated through mid-November 2014. The subsequent 2015 through 2018 years followed a similar schedule, but with different deployment dates and data gaps, with the goal always to capture the surface dynamics of the snow melt, growing, and freeze-up seasons. This Tram overview dataset has three objectives: (1) provide new data users with a brief description of the Tram system and its research purposes; (2) provide generally useful Tram site characterization details, including measurement position ground surface elevation, characteristics of the Arctic polygonal tundra under the Tram, vegetation community composition (future), and derived image products; and (3) reference all of the data products and archived datasets that were collected with the Tram-mounted sensors and co-located instruments. This dataset contains two csv files, two zipped files, one tif file, and one pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Multi-bit quantum random number generation by measuring positions of arrival photons

We report upon the realization of a novel multi-bit optical quantum random number generator by continuously measuring the arrival positions of photon emitted from a LED using MCP-based WSA photon counting imaging detector. A spatial encoding method is proposed to extract multi-bits random number from the position coordinates of each detected photon. The randomness of bits sequence relies on the intrinsic randomness of the quantum physical processes of photonic emission and subsequent photoelectric conversion. A prototype has been built and the random bit generation rate could reach 8 Mbit/s, with random bit generation efficiency of 16 bits per detected photon. FPGA implementation of Huffman coding is proposed to reduce the bias of raw extracted random bits. The random numbers passed all tests for physical random number generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

"DIAGNOSTIC" PULSE FOR SINGLE-PARTICLE-LIKE BEAM POSITION MEASUREMENTS DURING ACCUMULATION/PRODUCTION MODE IN THE LOS ALAMOS PROTON STORAGE RING

Beam position monitors (BPMs) are the primary diagnostic in the Los Alamos Proton Storage Ring (PSR). When injecting one turn, the transversemotion is approximated as a single particle with initial betatron position and angle {rvec x}{sub 0} and {rvec x}'{sub 0}. With single-turn injection, we fit the betatron tune, closed orbit (CO), and injection offset ({rvec x}{sub 0} and {rvec x}'{sub 0} at the injection point) to the turn-by-turn beam position. In production mode, we accumulate multiple turns, the transverse phase space fills after 5 injections (horizontal and vertical fractional betatron tunes {approx}0.2) resulting in no coherent betatron motion, and only the CO may be measured. The injection offset, which determines the accumulated beam size and is very sensitive to steering upstream of the ring, is not measurable in production mode. We describe our approach and ongoing efforts to measure the injection offset during production mode by injecting a 'diagnostic' pulse {approx}50 {micro}s after the accumulated beam is extracted. We also study the effects of increasing the linac RF gate length to accommodate the diagnostic pulse on the production beam position, transverse size, and loss.

43 PARTICLE ACCELERATORS↗

A beam profile and position measurement system for the IPF target

Currently one determines the size and position of the proton beam at the IPF target using plastic films. These films are installed in a target carrier, lowered into position, exposed to the beam, raised back up to the hot cell, removed from the target carrier, and assessed via a video feed. About an hour is required for each cycle of measurement. Because of this high cost in terms of time the users usually settle for a beam that is good enough to meet their needs, but not as good as they would like. I propose here a diagnostic device that would enable a measurement of under two seconds. This would enable delivery of a better-quality beam in less time.

43 PARTICLE ACCELERATORS↗

Simultaneous Momentum and Position Measurement and the Instrumental Weyl-Heisenberg Group

The canonical commutation relation, [Q,P]=iℏ, stands at the foundation of quantum theory and the original Hilbert space. The interpretation of P and Q as observables has always relied on the analogies that exist between the unitary transformations of Hilbert space and the canonical (also known as contact) transformations of classical phase space. Now that the theory of quantum measurement is essentially complete (this took a while), it is possible to revisit the canonical commutation relation in a way that sets the foundation of quantum theory not on unitary transformations but on positive transformations. This paper shows how the concept of simultaneous measurement leads to a fundamental differential geometric problem whose solution shows us the following. The simultaneous P and Q measurement (SPQM) defines a universal measuring instrument, which takes the shape of a seven-dimensional manifold, a universal covering group we call the instrumental Weyl-Heisenberg (IWH) group. The group IWH connects the identity to classical phase space in unexpected ways that are significant enough that the positive-operator-valued measure (POVM) offers a complete alternative to energy quantization. Five of the dimensions define processes that can be easily recognized and understood. The other two dimensions, the normalization and phase in the center of the IWH group, are less familiar. The normalization, in particular, requires special handling in order to describe and understand the SPQM instrument.

47 OTHER INSTRUMENTATION↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Position measurements in the de Broglie-Bohm interpretation of quantum mechanics

The de Broglie-Bohm interpretation of quantum mechanics assigns positions and trajectories to particles. We analyze the validity of a formula for the velocities of Bohmian particles which makes the analysis of these trajectories particularly simple. We apply it to particle detectors of four different types and show that the detectors of three of these types lead to 'surrealistic trajectories', i.e., leave a trace where the Bohmian particle was not present. - Highlights: Black-Right-Pointing-Pointer We perform computer simulation of Bohmian trajectories for position detectors. Black-Right-Pointing-Pointer A simplified velocity formula provides very precise (or exact) Bohmian trajectories. Black-Right-Pointing-Pointer Spin, phase, and Bohmian velocity type detectors exhibit surrealistic trajectories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute position measurement in a gas time projection chamber via transverse diffusion of drift charge

Time Projection Chambers (TPCs) with charge readout via micro pattern gaseous detectors can provide detailed measurements of charge density distributions. We here report on measurements of alpha particle tracks, using a TPC where the drift charge is amplified with Gas Electron Multipliers and detected with a pixel ASIC. We find that by measuring the 3-D topology of drift charge and fitting for its transverse diffusion, we obtain the absolute position of tracks in the drift direction. For example, we obtain a precision of 1~cm for 1~cm-long alpha track segments. To our knowledge this is the first demonstration of such a measurement in a gas TPC. This technique has several attractive features: it does not require knowledge of the initial specific ionization, is robust against bias from diffuse charge below detection threshold, and is also robust against high charge densities that saturate the detector response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗