Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PORFLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PORFLOW Modeling Supporting The H-Tank Farm Performance Assessment

Numerical simulations of groundwater flow and contaminant transport in the vadose and saturated zones have been conducted using the PORFLOW code in support of an overall Performance Assessment (PA) of the H-Tank Farm. This report provides technical detail on selected aspects of PORFLOW model development and describes the structure of the associated electronic files. The PORFLOW models for the H-Tank Farm PA, Rev. 1 were updated with grout, solubility, and inventory changes. The aquifer model was refined. In addition, a set of flow sensitivity runs were performed to allow flow to be varied in the related probabilistic GoldSim models. The final PORFLOW concentration values are used as input into a GoldSim dose calculator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PORFLOW Simulations Supporting Saltstone Disposal Unit Design Optimization

SRNL was requested by SRR to perform PORFLOW simulations to support potential cost-saving design modifications to future Saltstone Disposal Units in Z-Area (SRR-CWDA-2015-00120). The design sensitivity cases are defined in a modeling input specification document SRR-CWDA-2015-00133 Rev. 1. A high-level description of PORFLOW modeling and interpretation of results are provided in SRR-CWDA-2015-00169. The present report focuses on underlying technical issues and details of PORFLOW modeling not addressed by the input specification and results interpretation documents. Design checking of PORFLOW modeling is documented in SRNL-L3200-2015-00146.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CODE-TO-CODE BENCHMARKING OF THE PORFLOW AND GOLDSIM CONTAMINANT TRANSPORT MODELS USING A SIMPLE 1-D DOMAIN - 11191

An investigation was conducted to compare and evaluate contaminant transport results of two model codes, GoldSim and Porflow, using a simple 1-D string of elements in each code. Model domains were constructed to be identical with respect to cell numbers and dimensions, matrix material, flow boundary and saturation conditions. One of the codes, GoldSim, does not simulate advective movement of water; therefore the water flux term was specified as a boundary condition. In the other code, Porflow, a steady-state flow field was computed and contaminant transport was simulated within that flow-field. The comparisons were made solely in terms of the ability of each code to perform contaminant transport. The purpose of the investigation was to establish a basis for, and to validate follow-on work that was conducted in which a 1-D GoldSim model developed by abstracting information from Porflow 2-D and 3-D unsaturated and saturated zone models and then benchmarked to produce equivalent contaminant transport results. A handful of contaminants were selected for the code-to-code comparison simulations, including a non-sorbing tracer and several long- and short-lived radionuclides exhibiting both non-sorbing to strongly-sorbing characteristics with respect to the matrix material, including several requiring the simulation of in-growth of daughter radionuclides. The same diffusion and partitioning coefficients associated with each contaminant and the half-lives associated with each radionuclide were incorporated into each model. A string of 10-elements, having identical spatial dimensions and properties, were constructed within each code. GoldSim's basic contaminant transport elements, Mixing cells, were utilized in this construction. Sand was established as the matrix material and was assigned identical properties (e.g. bulk density, porosity, saturated hydraulic conductivity) in both codes. Boundary conditions applied included an influx of water at the rate of 40 cm/yr at one end of the string and no-flow lateral flow boundaries. A unit quantity of each contaminant was introduced at the influx boundaries and the rate of outflux at the opposite end of the 10-element string was recorded to make the comparisons. Saturated conditions were assumed in this evaluation. Under these carefully controlled conditions the two codes produced essentially identical results, demonstrating that both codes appear to be accurately implementing the contaminant transport mechanisms. The conclusion is that a satisfactory basis was established to justify the exercise in which 1-D GoldSim model was benchmarked against the 2-D unsaturated zone and 3-D saturated zone Porflow models used at the Savannah River Site (SRS).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PORFLOW modeling of Vadose zone flow and transport for the E-area intermediate level vault

In support of the E-Area Performance Assessment, a two-dimensional model of water flow and radionuclide transport through the E-Area Intermediate Level Vault (ILV) and local vadose zone has been developed using the PORFLOWTM software. The purpose of the model is to calculate flux to the water table for radionuclides eluted from the ILV during its operational life, the period of institutional control, and times following site closure. Results of model calculations will be used by a three-dimensional PORFLOW model of transport through the aquifer to determine radionuclide concentrations at a hypothetical 100 meter well and at the site boundary where contaminated groundwater could be assessed by members of the public following site closure. While newly developed, the model structure closely follows that used in the 2008 PA while incorporating a refined computational mesh, updated material properties for the vadose zone soil and vault concrete, revised infiltration rates, and new solid-liquid distribution coefficients. The model also addresses degradation of concrete hydraulic properties by blending soil and concrete water retention curves over a 500 year period. That is, the hydraulic properties of ILV concrete start out as fresh concrete at the time of site closure and degrade to soil properties over a 500 year time period. This approach has not been used previously in E-Area PA’s. The model has been used to calculate water flow through the ILV vadose zone and, on a trial basis, transport of a limited number of radionuclides from the waste region inside the ILV to the water table. Figure ES-1 provides a view of the model and an example of water flow after the concrete has substantially degraded. Figure dimensions are in centimeters. The red area in the left hand side figure is the waste disposal region within the ILV. Colored bands in the figures indicate different soil and concrete regions. Figure ES-2 shows a calculation of flux to the water table (mol/yr) for U-234 and its one-year half-life decay chain (U-234 → Th-230 → Ra-226 → Pb-210). Pb-210 flux is too small to show on the same scale used for Th-230 and Ra-226 in Figure ES-2. The model has also been used to make a preliminary evaluation of the release of tritium from TPBAR disposal containers that will be place in the ILV. A separately calculated tritium release rate as a function of time was used as a source in the PORFLOW model. The TPBAR disposal schedule and tritium release rate differ from the values used in the 2008 PA. Results from these initial trial runs are compared to calculations made for the 2008 PA ILV analysis. In brief, a new PORFLOW model of flow and transport through the ILV vadose zone has been developed and tested. The model is ready to be used for PA calculations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ABSTRACTION OF INFORMATION FROM 2- AND 3-DIMENSIONAL PORFLOW MODELS INTO A 1-D GOLDSIM MODEL - 11404

The Savannah River National Laboratory has developed a 'hybrid' approach to Performance Assessment modeling which has been used for a number of Performance Assessments. This hybrid approach uses a multi-dimensional modeling platform (PorFlow) to develop deterministic flow fields and perform contaminant transport. The GoldSim modeling platform is used to develop the Sensitivity and Uncertainty analyses. Because these codes are performing complementary tasks, it is incumbent upon them that for the deterministic cases they produce very similar results. This paper discusses two very different waste forms, one with no engineered barriers and one with engineered barriers, each of which present different challenges to the abstraction of data. The hybrid approach to Performance Assessment modeling used at the SRNL uses a 2-D unsaturated zone (UZ) and a 3-D saturated zone (SZ) model in the PorFlow modeling platform. The UZ model consists of the waste zone and the unsaturated zoned between the waste zone and the water table. The SZ model consists of source cells beneath the waste form to the points of interest. Both models contain 'buffer' cells so that modeling domain boundaries do not adversely affect the calculation. The information pipeline between the two models is the contaminant flux. The domain contaminant flux, typically in units of moles (or Curies) per year from the UZ model is used as a boundary condition for the source cells in the SZ. The GoldSim modeling component of the hybrid approach is an integrated UZ-SZ model. The model is a 1-D representation of the SZ, typically 1-D in the UZ, but as discussed below, depending on the waste form being analyzed may contain pseudo-2-D elements. A waste form at the Savannah River Site (SRS) which has no engineered barriers is commonly referred to as a slit trench. A slit trench, as its name implies, is an unlined trench, typically 6 m deep, 6 m wide, and 200 m long. Low level waste consisting of soil, debris, rubble, wood, etc. is disposed within the trench which is then covered with soil and a cap. The filled trench resembles the surrounding soil, albeit with a higher porosity. As a result, the flow field through the trench is essentially 1-dimensional. This dimensionality makes the abstraction of information from this waste form fairly simple. Engineered waste forms present challenges not seen in the slit trench because of their higher dimensionality. Flow fields must conform to the barriers and are therefore subject to changes in direction. This paper will examine one case and show how this multidimensional flow field can be abstracted into a 1-dimensional flow field while retaining characteristics important to the transport of radioactive contaminants. One complication not addressed by the two preceding examples is that of multiple sources. This presents quite a challenge to the benchmarking exercise, but a fairly robust method has been developed to deal with it. While the PorFlow analyses can treat all sources as independent in space, this is not possible with a 1-D model. This problem has been addressed by constructing multiple 1-D models of the waste forms and using plume overlaps at the assessment points to address the multiple sources which can contribute to a distinct assessment point.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PORFLOW 6.42.9 Testing and Verification Document

This report is a continuation of the series of PORFLOW QA documents including (Aleman, 2007; Whiteside, 2007, 2008, 2010a,c,b, 2016b,a, 2017a,b). In this report we have updated the test cases where necessary to account for new features in PORFLOW and to ensure those features perform as described in the documentation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Porflow modeling for a preliminary assessment of the performance of new saltstone disposal unit designs

At the request of Savannah River Remediation (SRR), SRNL has analyzed the expected performance obtained from using seven 32 million gallon Saltstone Disposal Units (SDUs) in the Z-Area Saltstone Disposal Facility (SDF) to store future saltstone grout. The analysis was based on preliminary SDU final design specifications. The analysis used PORFLOW modeling to calculate the release of 20 radionuclides from an SDU and transport of the radionuclides and daughters through the vadose zone. Results from this vadose zone analysis were combined with previously calculated releases from existing saltstone vaults and FDCs and a second PORFLOW model run to calculate aquifer transport to assessment points located along a boundary 100 m from the nearest edge of the SDF sources. Peak concentrations within 12 sectors spaced along the 100 m boundary were determined over a period of evaluation extending 20,000 years after SDF closure cap placement. These peak concentrations were provided to SRR to use as input for dose calculations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Porflow Modeling Supporting the FY13 Saltstone Special Analysis

PORFLOW modeling supporting the concurrent Saltstone FY13 Special Analysis (SA) is described in this report. The present simulations are based on the 2009 Performance Assessment and subsequent modeling to support a response to NRC Request for Additional Information PA-8. Notable changes to the baseline PA-8 model include revised degradation of cementitious materials and associated hydraulic properties, inclusion of floor joints and roof support columns in model representations, and a revised Tc-99 shrinking-core model to implement combined redox and solubility controls. Also presented are new and further justifications for key model assumptions, and verification test cases for selected model attributes. Results are presented for the nominal value simulation case, a flow sensitivity parametric study, and Tc-99 transport sensitivity cases. Further discussion of PORFLOW model setup and simulation results is presented in the Saltstone FY13 SA, including dose results.

Cementitious Materials↗

Porflow modeling supporting the FY14 salstone special analysis

PORFLOW related analyses supporting the Saltstone FY14 Special Analysis (SA) described herein are based on prior modeling supporting the Saltstone FY13 SA. Notable changes to the previous round of simulations include: a) consideration of Saltstone Disposal Unit (SDU) design type 6 under “Nominal” and “Margin” conditions, b) omission of the clean cap fill from the nominal SDU 2 and 6 modeling cases as a reasonable approximation of greater waste grout fill heights, c) minor updates to the cementitious materials degradation analysis, d) use of updated I-129 sorption coefficient (Kd) values in soils, e) assignment of the pH/Eh environment of saltstone to the underlying floor concrete, considering down flow through an SDU, and f) implementation of an improved sub-model for Tc release in an oxidizing environment. These new model developments are discussed and followed by a cursory presentation of simulation results. The new Tc release sub-model produced significantly improved (smoother) flux results compared to the FY13 SA. Further discussion of PORFLOW model setup and simulation results will be presented in the FY14 SA, including dose results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical convergence improvements for porflow unsaturated flow simulations

Section 3.6 of SRNL (2016) discusses various PORFLOW code improvements to increase modeling efficiency, in preparation for the next E-Area Performance Assessment (WSRC 2008) revision. This memorandum documents interaction with Analytic & Computational Research, Inc. (http://www.acricfd.com/default.htm) to improve numerical convergence efficiency using PORFLOW version 6.42 for unsaturated flow simulations.

97 MATHEMATICS AND COMPUTING↗

PORFLOW Simulations Supporting the Saltstone Performance Assessment Revision

The most recent Performance Assessment (PA) of the Z-Area Saltstone Disposal Facility (SDF) was performed in 2009, and three Special Analyses were subsequently conducted. Currently the SDF PA analysis is being revised by the Savannah River Remediation (SRR) Waste Disposal Authority group to reflect updated input information and assumptions, and improved understanding of disposal system performance. In support of the PA revision, Savannah River National Laboratory has developed revised methods for simulating the transport of I-129 and Tc-99 through porous media in a shrinking core model using the PORFLOW code. The revised methods are based on updated reduction capacity, I-129 distribution coefficient, and Tc-99 solubility values from SRR. PORFLOW simulations of aquifer transport have been revised to reflect a recent update to the General Separations Area groundwater flow model and improved treatment of plume dispersion. Hydraulic properties for some soils / sediments have been revised based on E-Area PA maintenance work. Example simulation results are provided to illustrate the behavior of the new I-129 and Tc-99 shrinking core models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PORFLOW Modeling of Vadose Zone Flow and Transport for the E- Area Low Activity Waste Vault

In support of the E-Area Performance Assessment, a two-dimensional model of water flow and radionuclide transport through the E-Area Low Activity Waste Vault (LAWV) and local vadose zone has been developed using the PORFLOW TM software. The purpose of the model is to calculate flux to the water table for radionuclides eluted from the LAWV during its operational life, the period of institutional control, and times following site closure. Results of model calculations will be used by a three-dimensional PORFLOW model of transport through the aquifer to determine radionuclide concentrations at a hypothetical 100 meter well and at the site boundary where contaminated groundwater could be accessed by members of the public following site closure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PORFLOW Modeling of Vadose Zone Flow and Transport for E-Area Intermediate Level Vault

In support of the E-Area Performance Assessment, a two-dimensional model of water flow and radionuclide transport through the E-Area Intermediate Level Vault (ILV) and local vadose zone has been developed using the PORFLOW TM software. The purpose of the model is to calculate flux to the water table for radionuclides eluted from the ILV during its operational life, the period of institutional control, and times following site closure. Results of model calculations will be used by a three-dimensional PORFLOW model of transport through the aquifer to determine radionuclide concentrations at a hypothetical 100 meter well and at the site boundary where contaminated groundwater is accessible to members of the public following site closure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PORFLOW Implementation of Vadose Zone Conceptual Model for Naval Reactor Component Disposal Area in the E-Area Low Level Waste Facility Performance Assessment

PORFLOW models have been developed to implement the proposed conceptual models for the two Naval Reactor Component Disposal Areas (NRCDAs), 643-7E and 643-26E, for the purpose of evaluating dose impacts and producing disposal limits for the E-Area Low-Level Facility (LLWF). New NRCDA conceptual models were proposed by Wohlwend and Butcher (2019) for two areas within/adjacent to the E-Area LLWF used as storage/disposal sites for reactor components from the U.S. Navy since 1987. Naval Reactor (NR) waste is comprised of highly radioactive components consisting of activated corrosion-resistant metal alloy contained within welded thick-walled steel casks, and auxiliary equipment primarily contaminated with lower levels of Activated Corrosion Products (ACPs) residing on the metal surfaces and contained within thinner-walled bolted containers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommended Strategy for Implementing PORFLOW Subsidence Infiltration Boundary Conditions

This technical memorandum summarizes a limited-in-scope sensitivity analysis that addresses uncertainty in the conservatism of blending infiltration rates for use as input boundary conditions in PORFLOW vadose zone simulations as opposed to blending flux-to-the-water-table outputs for different subsidence infiltration scenarios, as has been done historically.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Limited-In-Scope Comparison of Subsidence Scenarios For 3D Vadose Zone PORFLOW Trench Models

This technical memorandum summarizes the results from two separate sequences of 3D PORFLOW vadose zone flow and contaminant transport models that were used to test the impact of different spatial distributions of subsidence boundary conditions. More specifically, the two simulation setups used a general conceptual model for an engineered trench (ET): one with a subsided region specified in the center of the trench and one with a subsided region located at the end of the trench. Both subsided regions had the same geometric specifications (e.g., length, width, orientation), but used water infiltration rate boundary conditions that appropriately accounted for surface runoff and lateral drainage from the adjacent upslope intact regions of the final closure cap. Because of the substantially higher water infiltration rate associated with the subsided region at the end of the trench, this geometry produced higher absolute peak fluxes to the water table for all six radionuclides that were simulated. However, the slower release rate of the centrally located subsided hole geometry produced a higher flux to the water table in the time period subsequent to the absolute peak. A third model was implemented as a control, where the water infiltration rate that corresponds to the centrally located subsided region was applied at the end of the trench to highlight the purely geometric effects. The results show that a higher water infiltration rate produces a sharper peak, while a lower infiltration rate leads to a broader peak. A centrally located hole impacts more of the waste zone, producing a higher peak when an equal infiltration rate is applied. These generalized qualitative differences, and their impacts on the overall modeling workflow (i.e., from vadose zone models to limits and dose calculations), should receive appropriate consideration during the development of conceptual models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Porflow Implementation of Vadose Zone Conceptual Model for Slit and Engineered Trenches in the E-Area Low Level Waste Facility Performance Assessment

A summary of the conceptual models to be used in representing slit (ST) and engineered trenches (ET) in PORFLOW (ACRi 2018) simulations as part of the performance assessment (PA) of the E-Area Low Level Waste Facility (ELLWF) is presented. Key details that are discussed include: model geometries, spatially dependent hydro-stratigraphic representations, model dimensionality, and boundary conditions (i.e., infiltration rates, cover overhangs, subsidence). Accounting for differences in the percent of non-crushable materials, eighteen unique models, defined by seven hydro-stratigraphic groupings, will be used to represent slit and engineered trenches.

42 ENGINEERING↗

PORFLOW Implementation of Special Waste from Models for Slit and Engineered Trenches in the E-Area Low Level Waste Facility Performance Assessment

The implementation of special waste forms (SWFs) in the deterministic PORFLOW Slit Trench (ST) and Engineered Trench (ET) models to be used in the next revision of the E-Area Low Level Waste Facility’s (ELLWFs) Performance Assessment (PA) is outlined in this report. Four SWF implementation methods will be used: effective K d , delayed release, solubility-controlled/diffusion-controlled release, and complex SWF model updates. In addition, the implementation of models that address the presence of tall used equipment storage boxes in ST08-10 is considered a special waste form and will be described.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗