Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLARIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Measurement of Length Distribution of 1D Nanoparticles in Solution via Optical Polarimetry

The efficient measurement of the length distribution of nanotubes, nanowires, and other one-dimensional (1D) nanoparticles in solution is important to enable their incorporation into materials and devices and to optimize their processing for properties of interest, such as thermal/electrical conductivity or mechanical strength, in suspensions and composites. We report an electric-field (E-field)-assisted optical-polarimetry technique to measure the length distribution of ensembles of high-aspect-ratio particles in dilute suspension. The degree of alignment of polarizable 1D particles suspended in a fluid under Brownian motion explicitly depends on the E-field strength and the particle length. We show that it is possible to extract the length distribution of 1D nanoparticles suspended in an insulating fluid by applying a range of E-fields and using optical polarimetry to measure the corresponding alignment order parameter. Notably, the method is relatively insensitive to the diameter of the 1D particles, which can be poorly known or vary within a sample. The technique is validated with silver nanowires and carbon nanotubes of known lengths, as well as polymer-depletion-length-separated single-wall carbon nanotube samples with length distributions independently measured with analytical ultracentrifugation. Finally, we demonstrate the ability of the optical-polarimetry technique to quantify changes in the length distribution of ultranarrow, sub-nanometer-diameter single-wall carbon nanotubes under different types and durations of ultrasonication. Within its range of applicability (polarizable 1D nanoparticles in the 0.5 to 15 μm length range, constrained by the voltage stability of the media and the suspended particles), the E-field-assisted optical-polarimetry method is a particularly efficient and accurate method to measure the length distribution of nanowires and nanotubes in suspension.

1D nanoparticles↗

Quantitative Nonlinear Optical Polarimetry with High Spatial Resolution

Nonlinear optical microscopy such as in the optical second-harmonic generation (SHG) modality has become a popular tool today for probing materials in the physical and biological sciences. While imaging and spectroscopy are widely used in the microscopy mode, nonlinear polarimetry, which can shed light on materials’ symmetry and microstructure, is relatively underdeveloped. This is partly because quantitative analytical modeling of the optical SHG response for anisotropic crystals and films largely assumes low-numerical aperture (NA) focusing of light, where the plane-wave approximation is sufficient. Tight focusing provides unique benefits in revealing out-of-plane polarization responses, which cannot be detected by near-plane-wave illumination at normal incidence. Here, we outline a method for quantitatively analyzing SHG polarimetry measurements obtained under high-NA focusing within a microscope geometry. Experiments and simulations of a variety of standard samples, from single crystals to thin films, are in good agreement, including measured and simulated spatial SHG maps of ferroelectric domains. A solution to the inverse problem is demonstrated, where the spatial distribution of an SHG tensor with unknown tensor coefficient magnitudes is determined by experimentally measured polarimetry. The ability to extract the out-of-plane component of the nonlinear polarization in normal incidence is demonstrated, which can be valuable for high-resolution polarimetry of 2D materials, thin films, heterostructures, and uniaxial crystals with a strong out-of-plane response.

36 MATERIALS SCIENCE↗

Development of a portable high-T c spherical neutron polarimetry device at the Oak Ridge National Laboratory

Spherical neutron polarimetry is a powerful polarized neutron scattering technique used to determine complex magnetic structures which are only partly accessible by other methods. This technique measures the full neutron polarization change upon scattering from a sample by fully decoupling the incoming and outgoing neutron polarization with a zero-field chamber placed at the sample position. Recent advancements and testing are presented for a new spherical neutron polarimetry device utilizing high-T c superconducting YBCO films, PHiTPAD, at the High Flux Isotope Reactor at Oak Ridge National Laboratory. Furthermore, we introduce a conceptual design that utilizes wavelength-independent adiabatic transitions to adapt spherical neutron polarimetry for use with pulsed neutron sources, thereby expanding its potential applications in neutron scattering research.

47 OTHER INSTRUMENTATION↗

The Instrument of the Imaging X-Ray Polarimetry Explorer

While X-ray spectroscopy, timing, and imaging have improved much since 1962 when the first astronomical nonsolar source was discovered, especially wi the launch of the Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer, and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, which in turn is a result of the fate of approved missions and because celestial X-ray sources appear less polarized than expected. Only one positive measurement has been available until now: the Orbiting Solar Observatory measured the polarization of the Crab Nebula in the 1970s. The advent of microelectronics techniques has allowed for designing a detector based on the photoelectric effect of gas in an energy range where the optics are efficient at focusing in X-rays. Here we describe the instrument, which is the major contribution of the Italian collaboration to the Small Explorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will launch in late 2021. The instrument is composed of three detector units based on this technique and a detector service unit. Three mirror modules provided by Marshall Space Flight Center focus X-rays onto the detectors. We show the technological choices, their scientific motivation, and results from the calibration of the instrument. IXPE will perform imaging, timing, and energy-resolved polarimetry in the 2–8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Post maximum light and late time optical imaging polarimetry of type I superluminous supernova 2020znr

ABSTRACT Optical imaging polarimetry was conducted on the hydrogen poor superluminous supernova 2020znr during three phases after maximum light (≈ +34 d, +288 d, and +289 d). After instrumental and interstellar polarization correction, all measurements are consistent with null-polarization detection. Modelling the light curve with a magnetar spin-down model shows that SN2020znr has similar magnetar and ejecta parameters to other SLSNe. A comparison of the best-fitting values discussed in the literature on SN 2017egm and SN 2015bn, two hydrogen poor SLSNe showing an increase of polarization after maximum light, suggests that SN 2020znr has higher mass ejecta that may prevent access to the geometry of the inner ejecta with optical polarimetry. The combined information provided by spectroscopy and light-curve analysis of type I SLSNe may be an interesting avenue to categorize the polarization properties of this class of transients. This approach would require to expand the sample of SLSNe polarimetry data currently available with early and late time epochs new measurements.

2015bn↗

Electron Polarimetry

Electron polarimetry benefits from the ability to use processes with well- known analyzing powers, hence enabling high precision measurements. Several techniques are employed to measure electron beam polarization, including Mott, Møller, and Compton polarimetry. Each technique has particular advantages and disadvantages, depending on the application. This chapter will focus on the tech- niques used to measure electron beam polarization, with particular emphasis on the challenges and requirements for achieving high precision. The development of a conceptual design of a Compton polarimeter for the future Electron Ion Collider will also be discussed.

Gaskell, David↗

Commercially Fabricated Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiment

We report on the development of commercially fabricated multi-chronic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. The orders of magnitude increase in detector count for next-generation CMB experiments require a new approach in detector wafer production to increase fabrication throughput. Here, we describe collaborative efforts with a commercial superconductor electronics fabrication facility (SeeQC, Inc.) to fabricate antenna-coupled TES bolometer detectors. We have successfully fabricated an operational dual-polarization, dichroic sinuous antenna-coupled TES detector array on a 150-mm-diameter wafer. The fabricated detector arrays have average yield of 95% and excellent uniformity across the wafer. Both RF characteristics and TES bolometer properties are suitable for CMB observations. We successfully fabricated different types of TES bolometers optimized for frequency multiplexing readout, time-domain multiplexing readout, and microwave SQUID multiplexing readout. We also demonstrated high production throughput. We discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

47 OTHER INSTRUMENTATION↗

Recent Developments of Commercially Fabricated Horn Antenna-Coupled Transition-Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiments

Here we report on the successful fabrication of orthomode transducer-coupled transition-edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments with the superconductor electronics fabrication facility at SEEQC Inc. Commercial microfabrication foundry could provide increase in detector fabrication throughput for a next-generation CMB experiment, CMB-S4, that would deploy approximately one order of magnitude more detectors than current CMB experiments. We also developed TES bolometers with two TESs in series that have two different superconducting temperatures (Tc) using a superconducting proximity effect between niobium (Nb) and aluminum-manganese (AlMn) alloy. We will discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments and other experiments that require TESs and superconducting RF circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the electron-ion collider

We analyze beam-induced depolarizing effects in the hydrogen jet target (HJET) at the relativistic heavy ion collider (RHIC), which has been used for absolute hadron beam polarimetry and shall be employed at the electron-ion collider (EIC). The EIC’s higher bunch repetition frequencies and shorter bunch durations shift beam harmonics to frequencies that can resonantly drive hyperfine transitions in hydrogen, threatening to depolarize the target atoms. Using frequency-domain analysis of beam harmonics and hyperfine transition frequencies, we establish a photon emission threshold above which beam-induced fields are too weak to cause significant depolarization. For EIC injection (23.5 GeV) and flattop (275 GeV), beam-induced depolarization through the bunch structure renders operation at the current RHIC magnetic guide field at the target (𝐵 0 =120⁢ mT) untenable. Increasing the magnetic guide field at the target to 𝐵 0 ≈ 400⁢ mT moves all hyperfine transition frequencies to at least 3 times the cutoff frequency, ensuring reliable absolute beam polarimetry with the required 1% precision at the EIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of a Goldstone mode in the broken helix by time-resolved optical polarimetry

Magnets with isotropic easy-plane symmetry host Goldstone modes that can be leveraged for efficient spin transport. Here, we present a time-resolved optical polarimetry technique that allows us to detect and characterize such low-frequency modes, and use it to observe the Goldstone mode in the multi-Q broken helix phase of EuIn2As2. The strength of our technique comes from the ability to distinguish between nematic and magnetization dynamics in order to yield information about the mode structure, in addition to its frequency. We find that the nearly uniform spin precession characteristic of a Goldstone mode is realized only when a small magnetic field is used to unpin the broken helix from local strain generated during crystal growth. In this regime, the mode frequency scales linearly with the applied field due to the ground state C2z symmetry of the broken helix. Our work shows how optical polarimetry can be used to study the Goldstone modes of complex magnets.

Liebman-Peláez, A↗

Detecting axion dark matter with black hole polarimetry

The axion, as a leading dark matter candidate, is the target of many ongoing and proposed experimental searches based on its coupling to photons. Ultralight axions that couple to photons can also cause polarization rotation of light which can be probed by the cosmic microwave background. In this work, we show that a large axion field is inevitably developed around black holes due to the Bose-Einstein condensation of axions, enhancing the induced birefringence effects. Therefore, measuring the modulation of supermassive black hole imaging polarization angles is a strong probe to the axion-photon coupling due to the formation of the axion condensation (axion star) which enhances the axion field. The oscillating axion field around black holes induces polarization rotation on the black hole image, which is detectable and distinguishable from astrophysical effects on the polarization angle, as it exhibits distinctive temporal variability and frequency invariability. In this work, we perform the theoretical calculation on the axion star formation rate and correspondingly the enhanced axion field value near supermassive black holes. Then, we present the range of axion-photon couplings within the axion mass range 10 − 21 – 10 − 16 eV that can be probed by the Event Horizon Telescope. The axion parameter space probed by black hole polarimetry will expand with the improvement in sensitivity on the polarization measurement and more black hole polarimetry targets with determined black hole masses. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Disentangling x-ray dichroism and birefringence via high-purity polarimetry

High-brilliance synchrotron radiation sources have opened new avenues for x-ray polarization analysis that go far beyond conventional polarimetry in the optical domain. With linear x-ray polarizers in a crossed setting, polarization extinction ratios down to 10 -10 can be achieved. This renders the method sensitive to probe the tiniest optical anisotropies that would occur, for example, in strong-field quantum electrodynamics due to vacuum birefringence and dichroism. Here we show that high-purity polarimetry can be employed to reveal electronic anisotropies in condensed matter systems with utmost sensitivity and spectral resolution. Taking CuO and La 2 CuO 4 as benchmark systems, we present a full characterization of the polarization changes across the Cu K-absorption edge and their separation into dichroic and birefringent contributions. At diffraction-limited synchrotron radiation sources and x-ray lasers, where polarization extinction ratios of 10 -12 can be achieved, our method has the potential to assess birefringence and dichroism of the quantum vacuum in extreme electromagnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron polarimetry at EIC

The Electron-Ion Collider will be the first collider to use both polarized electron beams and polarized protons and light ions . This will offer unique opportunities to study the structure of protons and nuclei and answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of the uncertainties are critical for the success of the spin program at the EIC. The requirements for beam polarimetry are non-destructive with uncertainty less than 1%. At the Electron Storage Ring (ESR) and the Rapid Cycling Synchrotron (RCS), the electron beam polarization will be measured using wellestablished Compton polarimetry techniques. However, the EIC Compton polarimeter will face unique challenges, demanding further developments. A Mott polarimeter will also be employed at the source for initial polarization measurements. Both longitudinal and transverse polarization will be measured, with the capability to monitor polarization on a bunch-by-bunch basis. Achieving these precise measurements will be critical to controlling systematic uncertainties and ensuring the overall success of the EIC’s physics objectives.

Zhang, Zhengqiao (ORCID:0009000742521735)↗

Detecting Axion Dark Matter with Black Hole Polarimetry

The axion, as a leading dark matter candidate, is the target of many on-going and proposed experimental searches based on its coupling to photons. Ultralight axions that couple to photons can also cause polarization rotation of light which can be probed by cosmic microwave background. In this work, we show that a large axion field is inevitably developed around black holes due to the Bose-Einstein condensation of axions, enhancing the induced birefringence effects. Therefore, we propose measuring the modulation of supermassive black hole imaging polarization angles as a new probe to the axion-photon coupling of axion dark matter. The oscillating axion field around black holes induces polarization rotation on the black hole image, which is detectable and distinguishable from astrophysical effects on the polarization angle, as it exhibits distinctive temporal variability and frequency invariability. We present the range of axion-photon couplings within the axion mass range $10^{-21}-10^{-16}\text{eV}$ that can be probed by the Event Horizon Telescope. The axion parameter space probed by black hole polarimetry will expand with the improvement in sensitivity on the polarization measurement and more black hole polarimetry targets with determined black hole masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗

Analysis of Polarimetry Data with Angular Uncertainties

For a track based polarimeter, such as the Imaging X-ray Polarimetry Explorer (IXPE), the sensitivity to polarization depends on the modulation factor, which is a strong function of energy. In previous work, a likelihood method was developed that would account for this variation in order to estimate the minimum detectable polarization (MDP). That method essentially required that the position angles of individual events should be known precisely. In a separate work, however, it was shown that using a machine-learning method for measuring event tracks can generate track angle uncertainties, which can be used in the analysis. Here, the maximum likelihood method is used as a basis for revising the estimate of the MDP in a general way that can include uncertainties in event track position angles. The resultant MDP depends solely upon the distribution of track angle uncertainties present in the input data. Due to the physics of the IXPE detectors, it is possible to derive a simple relationship between these angular uncertainties and the energy-dependent modulation function as a step in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limits on X-Ray Polarization at the Core of Centaurus A as Observed with the Imaging X-Ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the 2–8 keV band from the nucleus of the radio galaxy Centaurus A (Cen A), using a 100 ks observation from the Imaging X-ray Polarimetry Explorer (IXPE). Nearly simultaneous observations of Cen A were also taken with the Swift, NuSTAR, and INTEGRAL observatories. No statistically significant degree of polarization is detected with IXPE. These observations have a minimum detectable polarization at 99% confidence (MDP 99 ) of 6.5% using a weighted, spectral model-independent calculation in the 2–8 keV band. The polarization angle ψ is consequently unconstrained. Spectral fitting across three orders of magnitude in X-ray energy (0.3–400 keV) demonstrates that the SED of Cen A is well described by a simple power law with moderate intrinsic absorption (N H ~ 10 23 cm -2 ) and a Fe Kα emission line, although a second unabsorbed power law is required to account for the observed spectrum at energies below 2 keV. This spectrum suggests that the reprocessing material responsible for this emission line is optically thin and distant from the central black hole. Our upper limits on the X-ray polarization are consistent with the predictions of Compton scattering, although the specific seed photon population responsible for the production of the X-rays cannot be identified. The low polarization degree, variability in the core emission, and the relative lack of variability in the Fe Kα emission line support a picture where electrons are accelerated in a region of highly disordered magnetic fields surrounding the innermost jet.

79 ASTRONOMY AND ASTROPHYSICS↗