Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUTONIUM CHLORIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Application of an Empirical Density Law via Python for Aqueous Plutonium Chloride Systems in MCNP6

Current aqueous plutonium processing models for criticality safety often contain significant bias due to material modeling assumptions. These solutions include plutonium chloride solutions, which are modeled as fictitious plutonium metal-water mixtures because little is known about the actual density of the solution. Furthermore, there is no current predictive capability for modeling plutonium metal-water mixtures that is approved for use at Los Alamos National Laboratory (LANL). Recent density measurements for aqueous plutonium chloride systems (PuCl 3 -HCl-H 2 O) now allow for the development and application of a more realistic density law. This work develops a Python-based density law for this ternary solution using an empirical method. This code can be used in conjunction with an MCNP6 input to determine the density and composition of a solution based upon user inputs of plutonium concentration, hydrochloric acid concentration, and temperature. The tool allows users to input plutonium and acid content of a solution in terms of molality, molarity, or concentration, and predicts density within the current data range within 1.4% of experimental data. Current preliminary MCNP6 calculations utilizing this tool have demonstrated a minimum decrease in system reactivity of 5% in comparison to the current modeling conventions. Thus, this tool enables more accurate criticality safety operational limits by better crediting chorine content while still maintaining necessary conservatism.

Density Law↗

Application of an Empirical Density Law via Python for Aqueous Plutonium Chloride Systems for MCNP6

Criticality safety models for aqueous plutonium chloride systems often contain a significant bias due to assumptions in material compositions. These systems are currently modeled as a fictitious metal-water mixture because little is known about the true solution density. Furthermore, no predictive density tools or capabilities for modeling aqueous plutonium chloride systems are approved for use at Los Alamos National Laboratory. Recent density measurements of this ternary system (PuCl 3 -HCl-H 2 O) have allowed for the development of a more realistic density law, which is applied in this work via an empirical method based in Python. This tool, entitled PuCS (Plutonium Chloride Solution tool) may be used to determine solution density and composition based on the plutonium content, acid content, and temperature for MCNP6 inputs. PuCS has been found to predict density within 2% of experimental data. In conclusion, MCNP6 calculations have found that crediting minimal amounts of free acid (0.5 M) may correspond to a ~12% decrease in peak reactivity in comparison to current modeling methods.

42 ENGINEERING↗

A Python Tool for Aqueous Plutonium Nitrate Density Law Input Preprocessing in MCNP6

Here, this work develops a predictive density tool in Python, named Plutonium Nitrate Solutions (PuNS), to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer method and an empirical method were implemented into the PuNS tool to generate atom densities for use in MCNP6 material cards. These material cards are directly prepared into an MCNP6 input text file and are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, and plutonium isotope weight percentages. The PuNS tool is validated and verified against the International Criticality Safety Benchmark Evaluation Project Handbook experiments and is observed to predict densities within a root mean square error of 0.89% for the Pitzer method and 1.82% for the empirical method. These errors in density lead to up to 1569 pcm difference in MCNP6 calculated k eff for the Pitzer method and up to a 1751 pcm difference for the empirical method when compared to experimental benchmarks. Simultaneous work is also being performed at Los Alamos National Laboratory and the University of New Mexico to create a similar tool for plutonium chloride solutions, named Plutonium Chloride Solution, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also facilitate an improved understanding of solution systems and a potential relaxation in the conservatism of current aqueous plutonium processing criticality safety limits.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effects of Chlorine Capture and a Proposed Density Law on the Reactivity of Plutonium Solution Systems

During fissionable material processing, all normal and credible abnormal conditions must remain safely subcritical. Nuclear Criticality Safety (NCS) uses a number of methods to determine subcriticality, one of which is the use of neutron transport codes such as MCNP6. In order to create models for use with MCNP6, both the geometry and materials in fissionable material processes must be known, or assumptions must be made and quantified for the impact to bias. One of the systems with a significant amount of bias due to material modeling assumptions is in the area of aqueous plutonium processing. These solutions are typically plutonium nitrate solutions or plutonium chloride solutions, which are modeled as fictitious plutonium metal-water mixtures because little is known about the actual density of the solution and there is no current predictive capability approved for use at Los Alamos National Laboratory (LANL) for modeling them. This research is currently underway to fill the gap and develop an algorithm for use with MCNP6 to model the density of plutonium chloride solutions. The method is to be validated with experimental data for density, and also validated with critical experiments using MCNP6. Note that the Chlorine Worth Study (CWS) was performed in December 2021 to help bridge the gap in chlorine data for critical experiments, and is currently awaiting International Criticality Safety Benchmark Evaluation Project (ICSBEP) review. This study was performed by LANL at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS). Additional information regarding this experiment may currently be found in LA-UR- 22-29180. Additionally, the Chemistry-Actinide Analytical Chemistry (C-AAC) at LANL has performed a number of solution density measurements for PuCl 3 -HC 1 -H 2 O, allowing for such data be used to create a semi-empirical density via the Pitzer method. The published dataset for the measurements is documented in LA-UR-22-25454. This method has already been tested successfully for aqueous plutonium nitrate solutions in SCALE. Current solution density measurements exist of plutonium concentrations of 0-~142g/L, all at 2M HC1, at temperatures 20-40°C. Additional data was taken for HC1-corrected density values, which essentially mimics the data for a pure PuCl x -water solution. The calculations in this report aim to support the current research by demonstrating the difference in system reactivity for the current modeling method when compared to the new proposed modeling with a density law implementation, which is being written as a Python tool to be used with MCNP6.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Experimental Steps toward a Density Law for Chlorine-Crediting Criticality Models of Aqueous Plutonium solutions

Criticality accident prevention is an essential safety consideration for all operations involving fissionable and fissile materials. Predictive criticality calculations using advanced neutron transport codes, such as Monte Carlo N-Particle Transport (MCNP), are invaluable tools for designing and implementing operational limits. While indispensable, these tools are limited by the quality and accuracy of the inputs that the user provides to define the modeled system. Parameters such as atomic composition, shape, and material density must be accurately defined to obtain a meaningful result. In the case of material property details for a plutonium model, accurate material characterization data is sometimes sparse. Thus limitations in calculation accuracy can be reduced by improving our knowledge of material properties in the targeted fissile systems. One of the biggest remaining challenges to accurately defining fissile systems is the description of aqueous fissile solutions. Even simple properties, such as density, are not well-known for fissile solutions relevant to nuclear energy and security. Described here are initial efforts undertaken to improve criticality calculation inputs for fissile plutonium chloride solutions in water. This effort is focused on experimentally determining accurate solution characteristics for ternary plutonium chloride/hydrochloric acid/water systems, by measurement of water activity and solution density. The effect of inputting experimental densities for these solutions into MCNP criticality calculations is compared to the traditional approach of modeling an idealized (and fictitious) plutonium-water mixture. Expansion of these efforts to a working density law for aqueous plutonium chloride solutions is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Water Solubility of Plutonium and Uranium Compounds and Residues at TA-55

Understanding the water solubility of plutonium and uranium compounds and residues at TA-55 is necessary to provide a technical basis for appropriate criticality safety, safety basis and accountability controls. Individual compound solubility was determined using published solubility data and solution thermodynamic modeling. Residue solubility was estimated using a combination of published technical reports and process knowledge of constituent compounds. The scope of materials considered includes all compounds and residues at TA-55 as of March 2016 that contain Pu-239 or U-235 where any single item in the facility has more than 500 g of nuclear material. This analysis indicates that the following materials are not appreciably soluble in water: plutonium dioxide (IDC=C21), plutonium phosphate (IDC=C66), plutonium tetrafluoride (IDC=C80), plutonium filter residue (IDC=R26), plutonium hydroxide precipitate (IDC=R41), plutonium DOR salt (IDC=R42), plutonium incinerator ash (IDC=R47), uranium carbide (IDC=C13), uranium dioxide (IDC=C21), U 3 O 8 (IDC=C88), and uranium filter residue (IDC=R26). This analysis also indicates that the following materials are soluble in water: plutonium chloride (IDC=C19) and uranium nitrate (IDC=C52). Equilibrium calculations suggest that PuOCl is water soluble under certain conditions, but some plutonium processing reports indicate that it is insoluble when present in electrorefining residues (R65). Plutonium molten salt extraction residues (IDC=R83) contain significant quantities of PuCl 3 , and are expected to be soluble in water. The solubility of the following plutonium residues is indeterminate due to conflicting reports, insufficient process knowledge or process-dependent composition: calcium salt (IDC=R09), electrorefining salt (IDC=R65), salt (IDC=R71), silica (IDC=R73) and sweepings/screenings (IDC=R78). Solution thermodynamic modeling also indicates that fire suppression water buffered with a commercially-available phosphate buffer would significantly reduce the solubility of PuCl 3 by the precipitation of PuPO 4 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigations into validation of plutonium solutions for criticality safety analysis

Plutonium solution chemistry is among the most complex of all the elements in the periodic table. Under acidic conditions up to four different oxidation states can be present in significant amounts in a single solution. From the perspective of nuclear criticality safety, accurate information regarding the concentration of plutonium and other constituents in solution must be well-known in order to correctly model plutonium solution systems for analysis. This requires knowledge of the solution system along with the ability to make accurate assumptions and predictions of the chemical and physical properties of the solution system. If neutron transport methods are used to assess subcriticality in a nuclear criticality safety analysis, the models must be compared with benchmark experiments which are similar and the suitability of the computer code system must be quantified. This paper describes some investigations undertaken to support the validation of plutonium solution systems for nuclear criticality safety analysis and how the Whisper sensitivity/uncertainty (S/U) tool can provide information to support validation of such systems. Case study results for various solution systems such as aqueous plutonium nitrate, aqueous plutonium chloride and hypothetical metal-water mixture are presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aqueous Chloride Operations Overview: Plutonium and Americium Purification/Recovery

Acqueous Chloride mission is to recover plutonium and americium from pyrochemical residues (undesirable form for utilization and storage) and generate plutonium oxide and americium oxide. Plutonium oxide is recycled into Pu metal production flowsheet. It is suitable for storage. Americium oxide is a valuable product, sold through the DOE-OS isotope sales program.

61 RADIATION PROTECTION AND DOSIMETRY↗

Chlorine Validation through Critical Integral Experiments

An increased interest in the validation of chlorine nuclear data, specifically 35Cl, in recent years has led to the prioritization of conducting chlorine critical experiments for nuclear data validation and criticality safety evaluations. A previous experiment was conducted with PVC and CPVC (chlorinated polyvinyl chloride) to reduce the margin of subcriticality for PF-4 operations with aqueous plutonium chloride solutions. Challenges in determining the composition of specific polymers, namely the CPVC, made it difficult to characterize, and therefore benchmark. Additional materials that were utilizable for chlorine validation were not immediately clear, as form, strength, purity, and composition are all important. A series of possible absorber materials were identified and studied, but ultimately granular sodium chloride was chosen. In addition to the needs of LANL’s PF-4 other industry collaborators have brought attention to the need for chlorine validation. Specifically, the need for HEU electrorefining with LiCl salts at Y-12 was taken into consideration for this experiment, with the experimental configurations being finely tuned to best meet their needs. Needs for validation were also presented by Idaho National Lab (INL) and TerraPower for validation of their Molten Chloride Reactor Experiment (MCRE) and Molten Chloride Fast Reactor (MCFR) and have also been considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Chloride Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

Uranium electrorefining operations at Y-12 require validation for chlorine absorption and reflection. Plutonium chloride solution operations at Los Alamos National Laboratory require chlorine absorption validation. The growing need for chlorine validation is evident to the wider criticality safety community, with multiple attendees at the recent TEX 2.0 meeting at Lawrence Livermore National Laboratory (May 2023) requesting validation for chlorine (Idaho National Laboratory (INL), Institute de radioprotection et de surete nucleaire (IRSN), Savannah River Nuclear Site (SRNS), LANL, and Y-12). Los Alamos National Laboratory has recently performed, and benchmarked, an experiment titled Chlorine Worth Study (CWS) for the internal operations at the lab, but due to the difficulties in precisely characterizing the material compositions of the chlorine absorbers it is advantageous to perform a complimentary study with a different chlorine-based absorber material. Furthermore, having a uranium-based vs plutonium-based experiment provides a separate and important validation basis for criticality safety and nuclear data evaluation. The original final design report for the study of chlorine absorption using the TEX-HEU experimental base was presented in 2022, but used the same chlorine-bearing materials that were found to be difficult to characterize in the LANL benchmark. A complete redesign of the experiment has been performed looking at alternative absorber materials in various forms to produce an experiment that is fully characterizable. This report presents five novel chlorine experiments using the TEX-HEU test bed which provides direct comparison to the Y-12 and INL/Terrapower application needs, utilizing sodium chloride (NaCl) absorber plates. The absorber plates will consist of granulated NaCl (≥99.5% pure), which will be fully encapsulated in aluminum tins, providing a simple but effective chlorine-based absorber material that can be completely characterized. Of the five configurations presented in this report, it is expected that two or three configurations will be down selected for the actual experiment, with the other configurations being alternates. Three of the configurations are in the standard configuration, where the absorber is placed directly on the HEU fuel plates, and two in the sandwich configuration, where the absorber is surrounded by polyethylene moderators to force additional neutron thermalization prior to reaching the absorber. There are two thicknesses of NaCl absorber plates: 3/16” and 1/4” active thicknesses (i.e. not including the encapsulation). Both variations of the absorbers have an active absorber radius of 6” and a total radius of 7.5” to match the diameter of the HEU plates, with the outer 1.5” being aluminum encapsulation. The high-density polyethylene (HDPE) moderators are of the thicknesses: 27/16”, 7/4”, 1/8”, 11/16”, and 3/4”. The final configurations have six (one sandwich and one standard configuration), eight (one sandwich and one standard configuration), and 18 total fuel layers (standard configuration). The standard and sandwich configurations were designed such that the differences in moderator thicknesses are 1” HDPE, which were already procured for the original CED-2. The proposed configurations were precisely tuned to closely match the sensitivity profiles and neutron spectra of the Y-12 upset cases and were also compared to the INL/Terrapower upset cases. The assessment of experimental uncertainties of the non-absorber components was predicted to be 0.00114 Δk eff . The assessment of uncertainties resulting from the absorbers was predicted to be 0.00029 Δk eff . This results in a total uncertainty of 0.00118 Δk eff . Many of the largest uncertainties, namely the moderator densities, may be reduced with precision dimensional inspection of the components. The 1” HDPE moderators as well as the HDPE reflectors from the original CED-2 were incorporated in the final designs presented here. Additional HDPE moderator plates must be fabricated to complete the configurations. NaCl absorber plates will by fabricated at LLNL. The total additional cost is expected to be $\$$54,250 for the remaining components. Precise inspection, including dimensional, mass, density, and impurity, is recommended for all components. LLNL estimates that these costs are around $\$$12,000. It is expected, based on previous TEX-HEU experiments, that three weeks of experimental facility time is needed to complete the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of a Density Law via Python for Aqueous Plutonium Nitrate

A predictive density tool has been developed in Python to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer Method and an empirical method were implemented into the tool, allowing for plutonium nitrate density calculations. Additionally, the Python tool can generate atom densities for a MCNP6.2 material card using the density from the selected method and directly the densities into a prepared MCNP6 input text file. The material card and density are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, plutonium isotope weight percentages and impurity concentrations. The Python tool has been validated and verified against the International Handbook of Evaluated Criticality Safety Benchmark Experiments to predict densities within a root mean square error of 1.0% for the Pitzer method and 1.8% for the empirical method. These errors in density were shown to lead to a ±0.5% error in MCNP6.2 calculated k effective for the Pitzer method and a ±1.7% error for the Empirical method. Simultaneous work is also being done at the University of New Mexico and Los Alamos National Laboratory to create a similar tool for plutonium chloride solutions, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also lead the way towards a better understanding of solution systems and potential relaxation in the conservatism of the current aqueous plutonium processing limits.

97 MATHEMATICS AND COMPUTING↗

A Semi-Empirical Density Law for Ternary, Homogeneous PuCl 3 /HCl/H 2 O Solutions

Nuclear material operations pose unique hazards that are not encountered in other chemical, energy, or manufacturing industries. One of these hazards is the potential for a nuclear criticality accident when handling fissile isotopes such as 235 U and 239 Pu. These hazards are particularly high when fissile material is dissolved in solution as the neutron behaviors of the system can change rapidly with the physical and chemical changes accessible in solution. Current estimates of solution density used for criticality safety are outdated and hinder fissile material handling. Developing new estimates for these safety calculations requires experimental characterization and the derivation of empirical density models. We have derived a density law describing PuCl 3 /HCl/H 2 O solutions from experimental data characterizing solution density. Density data was treated using a Pitzer-derived eight-parameter equation, defining density as a function of analyte concentrations, temperature, and interactions between these variables. The model is predictive across the concentration and temperature ranges from which it was derived. The potential effects of varying oxidation states of plutonium, which are easily accessible in aqueous media, on the bulk solution density of the ternary system were also investigated. The resulting Pitzer-derived density law was applied to a nuclear criticality safety model, and the impact of the experimental characterization of solution density relative to previous estimates was demonstrated to be significant and suggest that the current approach to estimating density in nuclear criticality safety calculations may lead to overly conservative controls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LOCALIZED CORROSION OF AUSTENITIC STAINLESS STEELEXPOSED TO MIXTURES OF PLUTONIUM OXIDE AND CHLORIDE SALTS

Laboratory corrosion tests were conducted to investigate the corrosivity of moist plutonium oxide/chloride (PuO{sub 2}/Cl-) salt mixtures on 304L and 316L stainless steel coupons. The tests exposed flat coupons for pitting evaluation and 'teardrop' stressed coupons for stress corrosion cracking (SCC) evaluation at room temperature to various mixtures of PuO{sub 2} and chloride-bearing salts for periods up to 500 days. The two flat coupons were placed so that the solid oxide/salt mixture contacted about one half of the coupon surface. One teardrop coupon was placed in contact with solid mixture; the second teardrop was in contact with the headspace gas only. The mixtures were loaded with nominally 0.5 wt % water under a helium atmosphere. Observations of corrosion ranged from superficial staining to pitting and SCC. The extent of corrosion depended on the total salt concentration and on the composition of the salt. The most significant corrosion was found in coupons that were exposed to 98 wt % PuO{sub 2}, 2 wt % chloride salt mixtures that contained calcium chloride. SCC was observed in two 304L stainless steel teardrop coupons exposed in solid contact to a mixture of 98 wt % PuO{sub 2}, 0.9 wt % NaCl, 0.9 wt % KCl, and 0.2 wt % CaCl{sub 2}. The cracking was associated with the heat-affected zone of an autogenous weld that ran across the center of the coupon. Cracking was not observed in coupons exposed to the headspace gas, nor in coupons exposed to other mixtures with either 0.92 wt% CaCl{sub 2} or no CaCl{sub 2}. The corrosion results point to the significance of the interaction between water loading and the concentration of the hydrating salt CaCl{sub 2} in the susceptibility of austenitic stainless steels to corrosion.

36 MATERIALS SCIENCE↗

Aqueous Chloride Operations Overview: Plutonium and Americium Purification/Recovery

These are a set of slides intended for an information session as part of recruiting activities at Brigham Young University. It gives an overview of aqueous chloride operations, specifically on plutonium and americium purification/recovery. This presentation details the steps taken perform these processes, from plutonium size reduction, dissolution, solvent extraction, oxalate precipitation, to calcination. For americium recovery, it details the CLEAR (chloride extraction and actinide recovery) Line, oxalate precipitation and calcination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decontamination of Plutonium from Fluoride and Chloride during Oxalate Precipitation, Filtration and Calcination Processes

Due to analytical limitations for the determination of fluoride (F) and chloride (Cl) in a previous anion exchange study, an additional study of the decontamination of Pu from F and Cl by oxalate precipitation, filtration and calcination was performed. Anion product solution from the previous impurity study was precipitated as an oxalate, filtered, and calcined to produce an oxide for analysis by pyrohydrolysis for total Cl and F. Analysis of samples from this experiment achieved the purity specification for Cl and F for the proposed AFS-2 process. Decontamination factors (DF's) for the overall process (including anion exchange) achieved a DF of ~5000 for F and a DF of ~100 for Cl. Similar experiments where both HF and HCl were spiked into the anion product solution to a ~5000 μg /g Pu concentration showed a DF of 5 for F and a DF of 35 for Cl across the combined precipitation-filtration-calcination process steps.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EVIDENCE OF CORROSIVE GAS FORMED BY RADIOLYSIS OF CHLORIDE SALTS IN PLUTONIUM-BEARING MATERIALS

Corrosion and pitting have been observed in headspace regions of stainless steel containers enclosing plutonium oxide/salt mixtures. These observations are consistent with the formation of a corrosive gas, probably HCl, and transport of that gas to the headspace regions of sealed containers. The NH{sub 4}Cl films found on the walls of the sealed containers is also indicative of the presence of HCl gas. Radiolysis of hydrated alkaline earth salts is the probable source of HCl.

36 MATERIALS SCIENCE↗