Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUTONIUM 239”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Options for the Removal of Cesium and Strontium from Acidic Uranyl Sulfate Solutions from Molybdenum-99 Production

A small laboratory-scale column process aimed at removing fission products from prototypical acidic sulfate solution wastes from a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (0.4 wt % 235 U), plutonium ( 239 Pu), neptunium ( 237 Np), non-radioactive surrogates of common fission products (including Cs and Sr) and two promising absorbents AMP-PAN and CST R91290-B. The goal of this work was to demonstrate the removal and concentration of high specific activity isotopes which are expected to dominate the classification of the low-level waste from the production of 99 Mo. Both AMP-PAN and CST R9120-B are attractive absorbents for the removal of 137 Cs from an acidic sulfate waste stream. They do not provide a solution for the removal of 90 Sr from the acidic solutions, but CST should be investigated at a higher pH. Limited removal of transuranic species and almost no removal of uranium was observed in this testing. This could be important due to the relatively large amount of uranium expected to be present in such waste streams. The capacity of these absorbents for 137 Cs will likely be dependent on the Cs concentration in the solutions processed but loading in the range of 0.2 to 5 mg Cs per gram of absorbent appears to be achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Options for the Removal of Cesium and Strontium from Acidic Uranyl Sulfate Solutions from Molybdenum-99 Production: Part II The Effect of Sodium Carbonate Adjustment to pH 9 on Strontium Removal

A small laboratory-scale column process aimed at removing fission products from prototypical acidic sulfate solution wastes from a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (0.4 wt % 235 U), plutonium ( 239 Pu), neptunium ( 237 Np), non-radioactive surrogates of common fission products (including Cs and Sr) and two promising absorbents – AMP-PAN and CST R9120-B. The goal of this work was to demonstrate the removal and concentration of high specific activity isotopes which are expected to dominate the classification of the low-level waste from the production of 99 Mo. Both AMP-PAN and CST R9120-B are attractive absorbents for the removal of 137 Cs from an acidic sulfate waste stream. They do not provide a solution for the removal of 90 Sr from the acidic solutions. CST was shown to be useful at removing both Cs and Sr after adjustment of the acidic sulfate solution with sodium carbonate to pH 9. Limited removal of transuranic species and almost no removal of uranium was observed for CST R9120B absorbent. This could be important due to the relatively large amount of uranium expected to be present in such waste streams. The capacity of these absorbents for 137 Cs will likely be dependent on the Cs concentration in the solutions processed but loading in excess of 0.7 mg Cs per gram of CST absorbent while loading 0.14 mg Sr per gram of CST absorbent appears to be achievable from pH 9 carbonate solution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In the Lab with Nuclear Scientists: Critical and Subcritical Assemblies

This presentation talks on the Critical experiments performed on the NCERC machines. Plutonium ( 239 Pu and 240 Pu), Highly Enriched Uranium, Low-Temperature (-40°C). This is all based on a simple design useful for modeling and validation. The design is made to incorporate materials of interest such as Tantalum, hafnium, lithium & more.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expanded Intercomparison of Nuclear Data Libraries Using Jupiter and Jupiter High-240 Experiments

There is a limited availability of plutonium experiments with sensitivity to lead in the ICSBEP (International Handbook of Evaluated Criticality Safety Benchmark Experiments) Handbook. The Jupiter and Jupiter High-240 experiments were performed at the National Criticality Experiments Research Center as a collaborative effort between Los Alamos National Laboratory and the Japan Atomic Energy Agency to assess lead void coefficients in a plutonium-lead system containing weapons- and reactor-grade plutonium, respectively. Concurrent with benchmark development, an intercomparison of calculations using different nuclear data libraries has been performed to assess the usability of the experimental data for nuclear data adjustment in a “softer-that-fast” neutron energy spectrum. Eigenvalue calculations using MCNP with the ENDF/B-VIII.0 and TENDL-2021 nuclear data libraries calculate closest to the benchmark values for Jupiter. Calculations using JENDL-5 and ENDF/B-VIII.1 match best with the Jupiter High-240 values. Lead void worth calculations using the various nuclear data libraries are all within 3σ of their respective measured values. Perturbation studies between ENDF/B-VIII.0 and ENDF/B-VIII.1 demonstrate an approximate increase in calculated eigenvalues for the Jupiter series experiments by ~240 pcm for plutonium (mostly 239 Pu) and ~120 pcm for lead accompanied by a decrease contributed by ~113 pcm for copper and ~13 pcm for stainless steel. Nuclear data sensitivities and uncertainties investigated using Whisper show slightly lower sensitivity to scatter than a lead-reflected plutonium sphere but greater sensitivity to neutron capture. The sensitivities between Jupiter and Jupiter High-240 for lead are very similar for both ENDF/B-VIII.0 and ENDF/B-VIII.1 nuclear data. These benchmarks are more sensitive to neutron capture in lead than other plutonium benchmark experiments and would be useful for both lead and 240 Pu validation. In conclusion, with the high degree of compensating effects between copper, lead, and plutonium cross sections, additional isolated Pb-Pu and Cu-Pu benchmarks would be beneficial in improving these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A refined assessment of nuclear data target accuracy requirements for ALFRED

The interest in target accuracy assessment has been recently renewed within the OECD/NEA Working Party on International Nuclear Data Evaluation Cooperation with an update exercise, thanks to the invaluable initiative of Massimo Salvatores. This work, moving from evaluations on the main core integral parameters of the Advanced Lead-cooled Fast Reactor European Demonstrator (ALFRED), and the identification of the associated target accuracies needed for improving its design, approaches the retrieval of target accuracy requirements for nuclear data, as the inverse problem of uncertainty quantification. The preliminary results obtained in a previous work are here refined by explicitly taking into account the total contribution due to correlations among variables in the optimization constraint, while its various components are evaluated individually. Moreover, three different sets of cost parameters are considered to introduce a bias in the solution in order to take in due account the relative difficulties in the execution of new differential experiments as needed for achieving the proposed target accuracies. By this, the obtained results are deemed usefully informative, and proposed for the update of a High Priority List which identifies the isotopes-reaction couples of most interest for future refinement experiments, especially when integrated with further analogous information collected on other advanced nuclear systems. Among the cross-sections whose refinement contributes the most to the reduction of the multiplication factor, the fission of Pu{sup 239} was found, which needs to be fixed below 1% in the range of interest for ALFRED (2 keV-4 MeV). Another contribution for the amelioration of the multiplication factor calculation accuracy, is due to the capture channel of Pu{sup 239}, for which the initial high uncertainty (around 15%) can be significantly reduced resorting to easily practicable experiments. The same occurs for the inelastic of Pb{sup 207}, for which the initial uncertainty value of around 50% can be drastically reduced up to target values between 4% and 7%.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector

SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of fission yield covariance matrices on decay heat uncertainty quantification with the DARWIN2 package

Although fission yields are strongly correlated, correlations between them are usually not taken into account when performing decay heat uncertainty calculations with the CEA DARWIN2 package due to the lack of reference covariance matrices associated to the JEFF-3.1.1 evaluation. However, covariance matrices for {sup 235}U and {sup 239}Pu thermal fission yields have been produced recently by the subgroup 37 of OECD/NEA Working Party on International Nuclear Data Evaluation Cooperation (WPEC). The study presented in this paper evaluates the effect of those covariances on the decay heat uncertainty calculation, both on fission burst experiments and on integral decay heat measurements that are part of the DARWIN2 experimental validation database. Although some differences are observed, partly due to the variety of models used to produce the matrices, the propagation of fission yield covariances always leads to a reduction of the decay heat uncertainty for cooling time above 10 seconds, indicating that not taking them into account is a conservative hypothesis from a safety point of view. Nevertheless, the strong impact of those covariances on the decay heat uncertainty also highlights the need of documented and consistent fission yield uncertainties and correlation data. On top of that, all the covariance matrices used for this study represent the correlation between the physical model parameters, but none of them includes the experimental correlations. An evaluation of the experimental correlations would also be of strong interest for decay heat uncertainty calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validating ENDF/B-VIII.1beta1 with LLNL Pulsed-Sphere Neutron-Leakage Spectra [Slides]

In this presentation 6 Li Distinct changes are observed. 235 U Discussion shows Improvements (seen in VIII.1beta0) are coming from new PFNS informed by Chi-Nu experimental data. Additionally, 239 Pu large changes coming from inelastic scattering. 9 Be ENDF/B-VIII.0 shows to be better right after elastic peak while 16 O had slight changes. 19 F had small improvements in ENDF/B-VIII.1 and 56 Fe had noticeable changes in thicker spheres. Examples of negligible changes for the sake of completeness are given.

16-Oxygen↗

Refreshing Waste Tracking Software for the 2020's - 20059

The Waste Compliance and Tracking System (WCATS) is a software application designed to manage waste operations from cradle to grave. The system provides the support needed for characterization, generation, processing, and shipment of all waste generated or stored at Los Alamos National Laboratory (LANL). Waste is tracked with task records for containers in real-time via both desktop and mobile device applications. The software allows application administrators to configure sites with appropriate limits for Pu-239 equivalent Curies (PE-Ci), fissile gram equivalents (FGEs), volume limits, as well as custom limits for site-specific technical safety requirements (TSRs). WCATS was developed based on a need at Los Alamos National Laboratory for a modern, customizable waste tracking system that could support many different waste types. The application is built using Oracle{sup R} database and Oracle{sup R} ADF Swing application framework. The technologies and software frameworks selected for the system were finalized in 2006. Although Oracle{sup R} Database has proven to be robust, the user interface and application framework interface with the database have been deprecated and need to be replaced. The technologies selected for modernization follow the open-source model, which allows the WCATS team to more easily recruit developers, improve the speed of development, and ease the deployment and adoption of the system. The tools that support the re-engineering effort are Vue.js{sup R}, a JavaScript{sup R} framework, and Spring Boot{sup R}, an API (application programming interface) development tool written in Java{sup R}. An API allows for simplified communication from the database to the user interface of the application. In addition, legacy Crystal Reports{sup R} will be replaced with reports developed with the open source Pentaho{sup TM}f Report Designer community edition. Because the application uses HTML and JavaScript{sup R}, it builds upon tools that have been used for many years in web development. These tools have large community support and their proven track record will ensure that enhancements to WCATS can continue for years to come. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Local aging effects in PuB 4 : Growing inhomogeneity and slow dynamics of local field fluctuations probed by 239 Pu NMR

Plutonium-based correlated electron materials host exotic physical phenomena ranging from unconventional heavy-fermion superconductivity to topological Kondo insulating states. Self-irradiation damage can influence many properties of such radioactive materials. Structural disorder effects due to α radiation have been frequently studied using techniques such as transport, thermodynamics, and x-ray diffraction. Here, in this study, we use 239 Pu nuclear magnetic resonance (NMR) to study the long-term influence of self-damage on the lattice and local electronic structures in a single crystal of the candidate topological insulator plutonium tetraboride (PuB 4 ). We first characterize the anisotropy of the 239 Pu resonance and confirm the local axial-site symmetry inferred from previous polycrystalline measurements. Aging effects are then evaluated over the time frame of six years. We find that, though the static 239 Pu NMR spectra show a slight modulation in their shape, their field-rotation pattern reveals no change in 239 Pu local site symmetry over time, suggesting that aging has a surprisingly small impact on the spatial distribution of the static hyperfine field. Further, ligand-site 11 B NMR finds little time-dependent change in the size of electric field gradient around 11 B sites. By contrast, aging has a prominent impact on the 239 Pu NMR relaxation processes and signal intensity. Specifically, aging-induced damage manifests itself as an increase in the spin-lattice relaxation time 𝑇 1 , an increased distribution of 𝑇 1 , and a signal intensity that decreases linearly by 20% per year. An effective spin-spin relaxation time 𝑇 2,eff in the aged sample shortens drastically towards lower temperature, suggesting growth of slow fluctuations of the hyperfine field that are linked to radiation-damage-induced inhomogeneity. Our NMR study sheds light on the interplay of radiation damage and local magnetic interactions in correlated insulators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Rapid Sequential Separation Method for Determination of Actinides and TENORM in Fracking Wastes - 20223

With recent advances in unconventional drilling technology in the US and around the world, the risks of environmental contamination and exposure due to technologically enhanced naturally occurring radioactive materials (TENORM) from fracking wastes have also surfaced. Although the Permian Basin (southeastern New Mexico, western Texas) has long been a modest producer of oil, the advent of fracking technology a decade ago turned it into hot property for producers. A 2018 assessment of undiscovered, technically recoverable continuous oil and gas resources by the U.S. Geological Survey estimates an average 46.3 billion barrels of oil and 281 trillion cubic feet of gas. This is likely to increase the use of unconventional drilling and TENORM generation. TENORM concentrations in oil and gas exploration and production waste can be several hundred to several thousand times higher than background TENORM concentrations. Both the thorium and uranium decay chains contribute to airborne radionuclides arising from the radon gas escaping the ground and subsequently decaying as airborne particulates. Additionally, radon decay products {sup 210}Pb and {sup 210}Po can build up in scale on the internal surfaces of oil and gas handling pipes and in sludge in refineries, becoming potential inhalation and ingestion hazards for workers. Furthermore, southeastern NM is also home to world's only licensed and operating transuranic nuclear waste repository, the DoE's Waste Isolation Pilot Plant (WIPP). Plutonium isotopes ({sup 239+240}Pu) and {sup 241}Am, are expected to account for more than 99% of the total radioactivity scheduled for disposal in the WIPP repository. Thus, an improved understanding of the environmental fate and transport of TENORM, liberated by unconventional drilling, is essential to assess how best to protect individuals and the environment. In this context, accurate measurement of TENORM and actinides in environmental and biological samples is essential. In this presentation, a new sequential method for the separation and pre-concentration of actinides (Pu, Am, Np) and TENORM (Po, U and Th) derived from oil and gas exploration is proposed. The TEVA method involves a rapid co-precipitation step to remove matrix interferences from the samples, followed by plutonium oxidation state adjustment to Pu (IV) and an incubation period of ∼ 1 hour at 50-60 deg. C to allow the resultant Po (II) to oxidize into Po(IV). The polonium, neptunium, thorium and plutonium are then separated on a TEVA column, while americium and uranium are separated on a TRU column. After separation, the alpha counting source was prepared by micro-precipitation with copper sulfide (CuS) for polonium and neodymium fluoride (NdF{sub 3}) for actinides. The efficiency and reliability of the procedures were tested by analyzing filter, drinking water and frack sand samples. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Rossi-alpha Measurements of Plutonium Using Organic Scintillators

In this work, Rossi-alpha measurements were simultaneously performed with a 3 He-based detection system and an organic scintillator-based detection system. The assembly is 15 kg of plutonium (93 wt% 239 Pu) reflected by copper and moderated by lead. The goal of Rossi-alpha measurements is to estimate the prompt neutron decay constant, alpha. Simulations estimate $k_{eff}$ = 0:624 and α = 52:3 ± 2:5 ns for the measured assembly. The organic scintillator system estimated α = 47:4 ± 2:0 ns, having a 9.37% error (though the 1.09 standard deviation confidence intervals overlapped). The 3 He system estimated α = 37 μs. The known slowing down time of the 3 He system is 35-40 μs, which means the slowing down time dominates and obscures the prompt neutron decay constant. Subsequently, the organic scintillator system should be used for assemblies with alpha much less than 35 μs.

3He↗

Dose reconstruction for plutonium-239 intakes at the Rocky Flats Plant

Purpose: The Rocky Flats (RF) Plant was a weapons manufacturing facility that operated from the early 1950s to 1989. Its primary missions were the production of plutonium (Pu) pits for thermonuclear weapons and the processing of retired weapons for Pu recovery. The purpose of this study was to estimate radiation doses to a cohort of 4499 RF workers from an intake of 239 Pu, the primary plutonium isotope handled at the site. Materials and methods: The latest biokinetic models of the International Commission on Radiological Protection, or site-specific variations of those models, were used to estimate 239 Pu intakes for each worker based on model fits to bioassay data often coupled with lung measurements. Results: Urinary excretion and lung retention data for most 239 Pu intakes could be fit reasonably well by a mixture of Pu dioxide and moderately soluble material. For some workers, better fits were obtained by application of other absorption types including Type S, 239 Pu nitrate, or pure 239 Pu dioxide, or by assuming intake via a wound. The lungs typically received the highest tissue doses, with fifty-year committed equivalent doses in the range of 0.5–1 Sv for 275 workers, 1–5 Sv for 115 workers, and greater than 5 Sv for 12 workers. Conclusions: RF was a unique site regarding a large number of lung measurements available for determining the appropriate absorption types for inhaled material. Further, this provided higher confidence in reconstructed 239 Pu doses than is generally gained from urinary data alone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Feasibility of Recycling Discharged Microreactor Heavy Metal in Light Water and Sodium-Cooled Fast Reactors: A Neutronics Analysis

Nuclear microreactors (MRs) offer unique advantages, such as rapid deployment, potability, low maintenance requirements, and operational flexibility. Their compact size makes them a promising solution for decentralized power generation, particularly in remote areas, military bases, and disaster-stricken regions. However, MRs face challenges, including unutilized fissile material at the end of life, economic inefficiency, increased heavy metal (HM) waste complicating disposal, and the accumulation of plutonium (Pu) with high 239 Pu concentrations raising proliferation risks. Here, this study investigated the neutronics feasibility of a novel three-stage fuel cycle where discharged HM from MRs is recycled and burned in light water reactors and sodium-cooled fast reactors. This approach converts discharged HM into valuable fuel, enhancing the efficiency of MR deployments while improving the safeguardability of their final waste products. Neutronics analysis demonstrated that the safety characteristics of reactor designs in each stage were minimally impacted by the proposed cycle. For two representative MR designs, a fast-spectrum MR with solid pellet fuel and a thermal-spectrum MR with TRISO (TRi-structural-ISOtropic) fuel compacts, the proposed fuel cycle reduced the uranium disposal mass flow rate by ~60%, decreased the 235 U enrichment of the discharge fuel to ~1 wt%, eliminated plutonium disposal, and increased the cumulative fuel burnup to ~580 gigawatt-day per metric ton of initial heavy metal (GWd/t-iHM) or 60% fissions per initial metal atom. Despite the significant differences between the two MR designs, the performance and infrastructure requirements of the developed fuel cycles were remarkably similar, indicating its generalizability to a broader class of MRs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Nondestructive and destructive assay for forensics characterization of weapons-grade plutonium produced in LEU irradiated in a thermal neutron spectrum

A post-irradiation examination (PIE) of an enriched uranium sample was performed to advance a nuclear forensics methodology, based on intra-elemental nuclide ratios. The PIE was carried out on a few milligrams of low enriched uranium dioxide (LEUO 2 ) sample, irradiated to a burnup of 1 GWd/MTU. The PIE of the LEUO 2 sample provided the concentration of selected plutonium and fission product nuclides ( 239 Pu, 240 Pu, 241 Pu, 91 Y, 95 Zr, 95 Nb, 103 Ru, 133 Cs, 134 Cs, 135 Cs, 137 Cs, 136 Ba, 138 Ba, 140 Ba, 140 La, 141 Ce, 144 Ce, 149 Sm, 150 Sm, 152 Sm, 153 Eu, and 154 Eu). The PIE supported validation of the MCNP (Monte Carlo N-Particle neutronics simulation code) predicted concentration of these nuclides in the irradiated LEUO 2 sample. This study showed that most of the MCNP predicted nuclide concentrations were within 15% and several within 10% compared to the PIE results. Furthermore, gamma and mass spectrometry of nuclides in irradiated LEUO 2 enabled the determination of uranium burnup and time since irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗