Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PLOTTING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of icing cloud instruments for 1982-1983 icing season flight program

A number of modern and old style liquid water content (LWC) and droplet sizing instruments were mounted on a DeHavilland DHC-6 Twin Otter and operated in natural icing clouds in order to determine their comparative operating characteristics and their limitations over a broad range of conditions. The evaluation period occurred during the 1982-1983 icing season from January to March 1983. Time histories of all instrument outputs were plotted and analyzed to assess instrument repeatability and reliability. Scatter plots were also generated for comparison of instruments. The measured LWC from four instruments differed by as much as 20 percent. The measured droplet size from two instruments differed by an average of three microns. The overall effort demonstrated the need for additional data, and for some means of calibrating these instruments to known standards.

Ide, R. F.

Comparison of icing cloud instruments for 1982-1983 icing season flight program

A number of modern and old style liquid water content (LWC) and droplet sizing instruments were mounted on a DeHavilland DHC-6 Twin Otter and operated in natural icing clouds in order to determine their comparative operating characteristics and their limitations over a broad range of conditions. The evaluation period occurred during the 1982-1983 icing season from January to March 1983. Time histories of all instrument outputs were plotted and analyzed to assess instrument repeatability and reliability. Scatter plots were also generated for comparison of instruments. The measured LWC from four instruments differed by as much as 20 percent. The measured droplet size from two instruments differed by an average of three microns. The overall effort demonstrated the need for additional data, and for some means of calibrating these instruments to known standards.

Ide, R. F.

Plots of ground coverage achieveable by global change monitoring instruments and spacecraft

Low Earth Orbit (LEO) and Geosynchronous Earth Orbit (GEO) satellite plots are given. All satellites are in an 800 km circular orbit at an inclination of 98.6 deg (sun synchronous). Specifics of the instrument package are given. Additionally, the time period of the plot and the percentage of the Earth covered during the time period are listed.

Knight, Heather R.

Application of the Langley plot method to the calibration of the solar backscattered ultraviolet instrument on the Nimbus 7 satellite

The concept of the well-known Langley plot technique, used for the calibration of ground-based instruments, has been generalized for application to satellite instruments. In polar regions, near summer solstice, the solar backscattered ultraviolet (SBUV) instrument on the Nimbus 7 satellite samples the same ozone field at widely different solar zenith angles. These measurements are compared to assess the long-term drift in the instrument calibration. Although the technique provides only a relative wavelength-to-wavelength calibration, it can be combined with existing techniques to determine the drift of the instrument at any wavelength. Using this technique, we have generated a 12-year data set of ozone vertical profiles from SBUV with an estimated accuracy of +/- 5% at 1 mbar and +/- 2% at 10 mbar (95% confidence) over 12 years. Since the method is insensitive to true changes in the atmospheric ozone profile, it can also be used to compare the calibrations of similar SBUV instruments launched without temporal overlap.

Bhartia, P. K.

Design and development of a fast scan infrared detection and measurement instrument

Infrared microscope instrument measures and plots the infrared profile of semiconductor chips, transistors and integrated circuits. Infrared analyses yields information on electrical and physical properties, enabling manufacturing improvements in semiconductor performance and reliability. Operational performance and main sections of the instrument are given.

Dostoomian, A. S.

International Ultraviolet Explorer observations of M87

A spectrum of M87 obtained in the 1150-2000 A spectral range by the IUE is discussed. The visual and UV energy distribution of the nucleus of M87 reveals an essentially continuous curve from 1300 to 10,500 A, and a turnup in flux below 2200 A. It is shown that this turnup is not a consequence of scattered light in the instrument, while a plot of the deconvolved M87 UV profile and the visual profile shows that the radiation in the 1300-2200 A spectral region is distributed in the same way as the visual radiation; it is not a point source. In addition, there is evidence in the UV for an emission line of C IV; the relative strengths of C IV, H beta, and the forbidden O III lines at 4959 and 5007 A are consistent with those seen in planetary nebulae, but the forbidden O II line at 3727 A is much too strong.

Bertola, F.

Assessing the Transferability of Statistical Predictive Models for Leaf Area Index Between Two Airborne Discrete Return LiDAR Sensor Designs Within Multiple Intensely Managed Loblolly Pine Forest Locations in the South-Eastern USA

Leaf area is an important forest structural variable which serves as the primary means of mass and energy exchange within vegetated ecosystems. The objective of the current study was to determine if leaf area index (LAI) could be estimated accurately and consistently in five intensively managed pine plantation forests using two multiple-return airborne LiDAR datasets. Field measurements of LAI were made using the LiCOR LAI2000 and LAI2200 instruments within 116 plots were established of varying size and within a variety of stand conditions (i.e. stand age, nutrient regime and stem density) in North Carolina and Virginia in 2008 and 2013. A number of common LiDAR return height and intensity distribution metrics were calculated (e.g. average return height), in addition to ten indices, with two additional variants, utilized in the surrounding literature which have been used to estimate LAI and fractional cover, were calculated from return heights and intensity, for each plot extent. Each of the indices was assessed for correlation with each other, and was used as independent variables in linear regression analysis with field LAI as the dependent variable. All LiDAR derived metrics were also entered into a forward stepwise linear regression. The results from each of the indices varied from an R2 of 0.33 (S.E. 0.87) to 0.89 (S.E. 0.36). Those indices calculated using ratios of all returns produced the strongest correlations, such as the Above and Below Ratio Index (ABRI) and Laser Penetration Index 1 (LPI1). The regression model produced from a combination of three metrics did not improve correlations greatly (R2 0.90; S.E. 0.35). The results indicate that LAI can be predicted over a range of intensively managed pine plantation forest environments accurately when using different LiDAR sensor designs. Those indices which incorporated counts of specific return numbers (e.g. first returns) or return intensity correlated poorly with field measurements. There were disparities between the number of different types of returns and intensity values when comparing the results from two LiDAR sensors, indicating that predictive models developed using such metrics are not transferable between datasets with different acquisition parameters. Each of the indices were significantly correlated with one another, with one exception (LAI proxy), in particular those indices calculated from all returns, which indicates similarities in information content for those indices. It can then be argued that LiDAR indices have reached a similar stage in development to those calculated from optical-spectral sensors, but which offer a number of advantages, such as the reduction or removal of saturation issues in areas of high biomass.

Sumnall, Matthew

Virtual Instrument Simulator for CERES

A benchtop virtual instrument simulator for CERES (Clouds and the Earth's Radiant Energy System) has been built at NASA, Langley Research Center in Hampton, VA. The CERES instruments will fly on several earth orbiting platforms notably NASDA's Tropical Rainfall Measurement Mission (TRMM) and NASA's Earth Observing System (EOS) satellites. CERES measures top of the atmosphere radiative fluxes using microprocessor controlled scanning radiometers. The CERES Virtual Instrument Simulator consists of electronic circuitry identical to the flight unit's twin microprocessors and telemetry interface to the supporting spacecraft electronics and two personal computers (PC) connected to the I/O ports that control azimuth and elevation gimbals. Software consists of the unmodified TRW developed Flight Code and Ground Support Software which serves as the instrument monitor and NASA/TRW developed engineering models of the scanners. The CERES Instrument Simulator will serve as a testbed for testing of custom instrument commands intended to solve in-flight anomalies of the instruments which could arise during the CERES mission. One of the supporting computers supports the telemetry display which monitors the simulator microprocessors during the development and testing of custom instrument commands. The CERES engineering development software models have been modified to provide a virtual instrument running on a second supporting computer linked in real time to the instrument flight microprocessor control ports. The CERES Instrument Simulator will be used to verify memory uploads by the CERES Flight Operations TEAM at NASA. Plots of the virtual scanner models match the actual instrument scan plots. A high speed logic analyzer has been used to track the performance of the flight microprocessor. The concept of using an identical but non-flight qualified microprocessor and electronics ensemble linked to a virtual instrument with identical system software affords a relatively inexpensive simulation system capable of high fidelity.

Chapman, John J.

Comparing dry aerosol size measurements

Two instruments were used to size dry aerosols for the CCN experiments: the Naval Research Laboratory (NRL) instrument which uses an electrical mobility analyzer to separate the aerosol size fractions and a diffusion chamber to grow and count the particles and the University of Wyoming (WYO) aerosol monitoring system. Measurements from these two systems were usually found to be in agreement during the CCN Workshop. Two examples are presented to compare aerosol size distribution measurements of the two instruments: experiment 8 (monodisperse NaCl) and experiment 27 (polydisperse AgI). Differential (dN/dR) and cumulative plots are shown for both instruments for experiment 8 and experiment 27; also shown are Aitken particle measurements for comparison.

Rogers, D. C.

A color graphics presentation of the Space Shuttle Orbiter windward surface entry temperature distribution

The windward surface temperature response measured during the fifth entry of the Space Shuttle Columbia is presented as solid filled color contour plots. These plots show the data from 92 instruments, at selected points in time, in a manner which makes the temperature extremes and gradients immediately obvious. Several physical phenomena, such as separated flow caused by the deflected body flap, local heating at the elevon-elevon gap, an overview of the propagation of boundary-layer transition over the Orbiter windward surface, and the thermal response of eight catalytically coated tiles, can be observed or inferred from the displayed temperatures. In addition, the maximums from each instrument have been contoured and are presented with a companion plot showing the percentage of surface area covered by each contour level. Also, the flight data are presented using the colors which correspond to the surface emittance as a function of temperature. To show the temperature transients, a computer-generated movie has been produced showing the temperature contours from 100 s to 1500 s after entry interface.

Martin, F. W., Jr.

Scanner observations of cool stars from 3400 to 11,000 A.

Evaluation of photoelectric scans of the M supergiant alpha Ori and the carbon stars 19 Psc, W Ori, and DS Peg made at 20-A resolution from 3400 to 6000 A and at 40-A resolution from 6000 to 11,000 A. The data are corrected for atmospheric extinction and for the instrumental response to obtain plots of log flux per unit frequency interval versus wavelength. The dominant spectral features are due to C2, CN, and TiO; the variation of these features with spectral class is pointed out.

Fay, T.

Hazardous Gas Leak Analysis in the Space Shuttle

Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.

Barile, Ronald G.

Hydrogen leak detection in the Space Shuttle

This study focuses on a helium gas jet flowing into room air. Measurements of helium concentration and velocity in the jet-air mixture are reported. The objective is to learn about jet characteristics so that dynamically similar hydrogen leaks may be located in the Space Shuttle. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers to monitor the shuttle environment for leaks. The mass spectrometers are fed by long sample tubes which draw gas from the payload bay, mid body, aft engine compartment and external tank. The overall purpose of this study is to improve the HGDS especially in its potential for locating hydrogen leaks. A rapid-response leak detection experiment was designed, built, and tested, following on the work done in this program last summer. The apparatus included a Perkin Elmer MGA-1200 mass spectrometer and air velocity transducer, both monitored by a Macintosh IIFX computer using LabVIEW software. A jet of helium flowing into the lab air simulated a gas leak. Steady helium or hydrogen-nitrogen jets were logged for concentration and velocity, and the power spectral density of each was computed. Last year, large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MGA-1200 was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MGA data. No peaks were detected in the power spectrum, so in the present study, 10 Hz bandwidth-averaged power levels were examined at regular frequency intervals. The practical consequences of last year's study are as follows: sampling frequency should be increased above the present rate of 1 sample per second so that transients could be observed and analyzed with frequency response methods. Many more experiments and conditions were observed in this second summer, including the effects of orifice diameter, jet velocity, sample tube design, radial effects, vertical flow, and low hydrogen concentrations (1 percent). A frequent observation was that the power spectrum, calculated from the Fourier transform of concentration fluctuations, gives a separate piece of information from concentration. Many of the tests suggest that power is high where mixing occurs at the helium-air interface. This fact is apparently independent of the concentration level, which could be high or low, but depends on the sample location relative to the jet (leak) origin, whereas high concentration may be due to a strong leak far away or a small leak close to the sample tube. If the power is low for any concentration level, this would signify helium is arriving at the sample tube by diffusion, not chaotic mixing caused by the jet interaction with air. The practical result is to propose a modification of the HGDL mass spectrometer data sampling and software so that sampling rates could be capable of observing at least 25 Hz fluctuations.

Barile, Ronald G

Ozone intercomparisons from the Balloon Intercomparison Campaign

Intercomparisons of remote and in-situ techniques used to measure stratospheric ozone are made using results obtained on the Balloon Intercomparison Campaign of 1982 and 1983. Two in-situ and four remote instruments participated. These included ECC ozonesondes, a UV absorption photometer, and microwave emission, IR emission, and absorption spectrometers. Differences are generally less than 15 percent, and are within the quoted error bars. Flights which involved different sets of instruments were made on four separate days, and results are intercompared in plots of ozone density versus altitude. A careful assessment of errors was made for each instrument, and a plot of absolute errors versus altitude is given.

Robbins, D.