At least 19 records

Comparative analyses of plasma probe diagnostics techniques

The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much as an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-flight calibration of mesospheric rocket plasma probes

Many effects and factors can influence the efficiency of a rocket plasma probe. These include payload charging, solar illumination, rocket payload orientation and rotation, and dust impact induced secondary charge production. As a consequence, considerable uncertainties can arise in the determination of the effective cross sections of plasma probes and measured electron and ion densities. We present a new method for calibrating mesospheric rocket plasma probes and obtaining reliable measurements of plasma densities. This method can be used if a payload also carries a probe for measuring the dust charge density. It is based on that a dust probe's effective cross section for measuring the charged component of dust normally is nearly equal to its geometric cross section, and it involves the comparison of variations in the dust charge density measured with the dust detector to the corresponding current variations measured with the electron and/or ion probes. In cases in which the dust charge density is significantly smaller than the electron density, the relation between plasma and dust charge density variations can be simplified and used to infer the effective cross sections of the plasma probes. We illustrate the utility of the method by analysing the data from a specific rocket flight of a payload containing both dust and electron probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single shot high bandwidth laser plasma probe

Herein a novel scheme to probe a plasma's ion acoustic resonances in single shot high-bandwidth pump-probe experiments is proposed. Our design utilizes concepts similar to smoothing by spectral dispersion; however, we propose a method of applying the bandwidth to the probe that avoids the effects of angular dispersion. Theoretical modeling and fluid simulations of the interaction are presented and compared. The results show the possibility of recovering a plasma's full complex index of refraction in a single shot pump-probe experiment. This wavelength dependent refractive index is directly related to the plasma's particle distribution function and can be used to recover plasma parameters including electron and ion temperatures, electron density, and plasma flow velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density dependence of impedance probe plasma potential measurements

In earlier works, we used spheres of various sizes as impedance probes in demonstrating a method of determining plasma potential, φ{sub p}, when the probe radius is much larger than the Debye length, λ{sub D}. The basis of the method in those works [Walker et al., Phys. Plasmas 13, 032108 (2006); ibid. 15, 123506 (2008); ibid. 17, 113503 (2010)] relies on applying a small amplitude signal of fixed frequency to a probe in a plasma and, through network analyzer-based measurements, determining the complex reflection coefficient, Γ, for varying probe bias, V{sub b}. The frequency range of the applied signal is restricted to avoid sheath resonant effects and ion contributions such that ω{sub pi} ≪ ω ≪ ω{sub pe}, where ω{sub pi} is the ion plasma frequency and ω{sub pe} is the electron plasma frequency. For a given frequency and applied bias, both Re(Z{sub ac}) and Im(Z{sub ac}) are available from Γ. When Re(Z{sub ac}) is plotted versus V{sub b}, a minimum predicted by theory occurs at φ{sub p} [Walker et al., Phys. Plasmas 17, 113503 (2010)]. In addition, Im(Z{sub ac}) appears at, or very near, a maximum at φ{sub p}. As n{sub e} decreases and the sheath expands, the minimum becomes harder to discern. The purpose of this work is to demonstrate that when using network analyzer-based measurements, Γ itself and Im(Z{sub ac}) and their derivatives are useful as accompanying indicators to Re(Z{sub ac}) in these difficult cases. We note the difficulties encountered by the most commonly used plasma diagnostic, the Langmuir probe. Spherical probe data is mainly used in this work, although we present limited data for a cylinder and a disk. To demonstrate the effect of lowered density as a function of probe geometry, we compare the cylinder and disk using only the indicator Re(Z{sub ac})

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bunker probe: A plasma potential probe almost insensitive to its orientation with the magnetic field

Due to their ability to suppress a large part of the electron current and thus measuring directly the plasma potential, ion sensitive probes have begun to be widely tested and used in fusion devices. For these probes to work, almost perfect alignment with the total magnetic field is necessary. This condition cannot always be fulfilled due to the curvature of magnetic fields, complex magnetic structure, or magnetic field reconnection. In this perspective, we have developed a plasma potential probe (named Bunker probe) based on the principle of the ion sensitive probe but almost insensitive to its orientation with the total magnetic field. Therefore it can be used to measure the plasma potential inside fusion devices, especially in regions with complex magnetic field topology. Experimental results are presented and compared with Ball-Pen probe measurements taken under identical conditions. We have observed that the floating potential of the Bunker probe is indeed little affected by its orientation with the magnetic field for angles ranging from 90° to 30°, in contrast to the Ball-Pen probe whose floating potential decreases towards that of a Langmuir probe if not properly aligned with the magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing plasma wakefields using electron bunches generated from a laser wakefield accelerator

Here, we show experimental results of probing the electric field structure of plasma wakes by using femtosecond relativistic electron bunches generated from a laser wakefield accelerator. Snapshots of laser-driven linear wakes in plasmas with different densities and density gradients are captured. The spatiotemporal evolution of the wake in a plasma density up-ramp is recorded. Two parallel wakes driven by a laser with a main spot and sidelobes are identified in the experiment and reproduced in simulations. The capability of this new method for capturing the electron- and positron-driven wakes is also shown via 3D particle-in-cell simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Argon–oxygen dc magnetron discharge plasma probed with ion acoustic waves

The precise determination of the relative concentration of negative ions is very important for the optimization of magnetron sputtering processes, especially for those undertaken in a multicomponent background produced by adding electronegative gases, such as oxygen, to the discharge. The temporal behavior of an ion acoustic wave excited from a stainless steel grid inside the plasma chamber is used to determine the relative negative ion concentration in the magnetron discharge plasma. The phase velocity of the ion acoustic wave in the presence of negative ions is found to be faster than in a pure argon plasma, and the phase velocity increases with the oxygen partial pressure. Optical emission spectroscopy further confirms the increase in the oxygen negative ion density, along with a decrease in the argon positive ion density under the same discharge conditions. The relative negative ion concentration values measured by ion acoustic waves are compared with those measured by a single Langmuir probe, and a similarity in the results obtained by both techniques is observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing plasma physics with spectral index maps of accreting black holes on event horizon scales

The Event Horizon Telescope (EHT) collaboration has produced the first resolved images of the supermassive black holes at the centre of our galaxy and at the centre of the elliptical galaxy M87. As both technology and analysis pipelines improve, it will soon become possible to produce spectral index maps of black hole accretion flows on event horizon scales. Here, in this work, we predict spectral index maps of both M87* and Sgr A* by applying the general relativistic radiative transfer (GRRT) code IPOLE to a suite of general relativistic magnetohydrodynamic (GRMHD) simulations. We analytically show that the spectral index increases with increasing magnetic field strength, electron temperature, and optical depth. Consequently, spectral index maps grow more negative with increasing radius in almost all models, since all of these quantities tend to be maximized near the event horizon. Additionally, photon ring geodesics exhibit more positive spectral indices, since they sample the innermost regions of the accretion flow with the most extreme plasma conditions. Spectral index maps are sensitive to highly uncertain plasma heating prescriptions (the electron temperature and distribution function). However, if our understanding of these aspects of plasma physics can be tightened, even the spatially unresolved spectral index around 230 GHz can be used to discriminate between models. In particular, Standard and Normal Evolution (SANE) flows tend to exhibit more negative spectral indices than Magnetically Arrested Disc (MAD) flows due to differences in the characteristic magnetic field strength and temperature of emitting plasma.

(magnetohydrodynamics) MHD↗

Probing the plasma near high power wave launchers in fusion devices for static and dynamic electric fields (invited)

An exploratory study was carried out in the long-pulse tokamak Tore Supra, to determine if electric fields in the plasma around high-power, RF wave launchers could be measured with non-intrusive, passive, optical emission spectroscopy. The focus was in particular on the use of the external electric field Stark effect. The feasibility was found to be strongly dependent on the spatial extent of the electric fields and overlap between regions of strong (>∼1 kV/cm) electric fields and regions of plasma particle recycling and plasma-induced, spectral line emission. Most amenable to the measurement was the RF electric field in edge plasma, in front of a lower hybrid heating and current drive launcher. Electric field strengths and direction, derived from fitting the acquired spectra to a model including time-dependent Stark effect and the tokamak-range magnetic field Zeeman-effect, were found to be in good agreement with full-wave modeling of the observed launcher.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of plasma impedance probe for measuring electron density and collision frequency in a plasma with spatial and temporal gradients

Numerical simulations and experimental measurements were combined to determine the ability of a plasma impedance probe (PIP) to measure plasma density and electron collision frequency in a plasma containing spatial gradients as well as time-varying oscillations in the plasma density. A PIP is sensitive to collision frequency through the width of the parallel resonance in the Re[Z]-vs.-frequency characteristic, while also being sensitive to electron density through the zero-crossing of the Im[Z]-vs.-frequency characteristic at parallel resonance. Simulations of the probe characteristic in a linear plasma gradient indicated that the broadening of Re[Z] due to the spatial gradient obscured the broadening due to electron collision frequency, preventing a quantitative measurement of the absolute collision frequency for gradients considered in this study. Simulation results also showed that the PIP is sensitive to relative changes in electron collision frequency in a spatial density gradient, but a second broadening effect due to time-varying oscillations made collision frequency measurements impossible. The time-varying oscillations had the effect of causing multiple zero-crossings in Im[Z] at parallel resonance. Results of experiments and simulations indicated that the lowest-frequency zero-crossing represented the lowest plasma density in the oscillations and the highest-frequency zero-crossing represented the highest plasma density in the oscillations, thus the PIP probe was found to be an effective tool to measure both the average plasma density as well as the maximum and minimum densities due to temporal oscillations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The relationship between the macroscopic state of electrons and the properties of chorus waves observed by the Van Allen Probes

Plasma kinetic theory predicts that a sufficiently anisotropic electron distribution will excite whistler mode waves, which in turn relax the electron distribution in such a way as to create an upper bound on the relaxed electron anisotropy. Here using whistler mode chorus wave and plasma measurements by Van Allen Probes, we confirm that the electron distributions are well constrained by this instability to a marginally stable state in the whistler mode chorus waves generation region. Lower band chorus waves are organized by the electron β ∥e into two distinct groups: (i) relatively large-amplitude, quasi-parallel waves with β ∥e ≳0:025 and (ii) relatively small-amplitude, oblique waves with β ∥e ≲0:025. The upper band chorus waves also have enhanced amplitudes close to the instability threshold, with large-amplitude waves being quasi-parallel whereas small-amplitude waves being oblique. These results provide important insight for studying the excitation of whistler mode chorus waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

A 10-ps, 263-nm (4{omega}) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution ({approx}1 -{mu}m full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10{sup 4} with respect to all wavelengths outside of the 263 {+-} 2 nm measurement range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of the Ion Current to a Probe in Plasma with Allowance for Ionization and Ion–Neutral Collisions: II. Cylindrical Probe

The ion current to a cylindrical probe is considered with allowance for volume ionization, ion–neutral collisions, and the ion orbital moment. A model based on the molecular dynamics method and applicable in a wide range of plasma parameters (r{sub p}/λ{sub D}= 0.01–100, r{sub i}/λ{sub D}= 0.002–200, ν{sub i}/ω{sub 0i}= 0.01–0.05, and T{sub i}/T{sub e} = 0−0.01) is proposed A convenient representation of the dependence of the relative ion current density on the Langmuir coefficient β{sup 2} and a technique for determining the plasma density from simulation results are offered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning ion sensitive probe for plasma profile measurements in the boundary of the Alcator C-Mod tokamak

A new Ion Sensitive Probe head has been created for the outer-midplane scanning probe system on the Alcator C-Mod tokamak. The new probe head contains three elements: an ion sensitive probe to measure ion temperature and plasma potential, a Langmuir probe to measure electron temperature, density, and floating potential, and a second Langmuir probe to measure ion saturation current and the density fluctuations arising from ''blob'' events. The ion sensitive probe current is normalized to this measurement to reduced deleterious effects of the strong fluctuations. Design of the high heat flux probe (>100 MW/m{sup 2}) and initial results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Movable multi-probes for plasma boundary measurement in sino-united spherical tokamak

A novel movable multi-probes is developed to get local magnetic and electrostatic profiles on Sino-UNIted Spherical Tokamak (SUNIST). This multi-probes combines a four-tips Langmuir probe, a magnetic coil, and a retarding field energy analyzer (RFEA). It can be used to simultaneously measure the poloidal magnetic field B{sub p}, electric field E{sub r}, electron temperature T{sub e}, electron density n{sub e}, and ion temperature T{sub i}. Its small overall size (20 × 20 × 38 mm{sup 3}) enables the movable multi-probes to measure the magnetic and electrostatic profiles in high spatial resolution, with negligible impact to plasma in SUNIST. This paper presents the design of the movable multi-probes, in particular, details of RFEA for reliable ion energy measurements. Preliminary experimental results of the movable multi-probes are given as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing dense plasmas for HEDS and ICF*

This paper is a retrospective of almost four decades of conceptualization and development of active x-ray probing of dense plasmas, involving multiple teams. In hindsight it was a surprisingly nonlinear and nonsystematic progression, with cycles of key epiphanies followed by multi-step technique optimization, spanning years.Further, each new idea or endeavor, whether or not realized / successful, spawned the next, and not necessarily in order of difficulty. The journey can be summarized by adapting/paraphrasing what Edward Teller said about NIF, that we develop new capabilities precisely because we don't know what those capabilities will enable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond Probing of Plasma Wakefields and Observation of the Plasma Wake Reversal Using a Relativistic Electron Bunch

We show that a high-energy electron bunch can be used to capture the instantaneous longitudinal and transverse field structures of the highly transient, microscopic, laser-excited relativistic wake with femtosecond resolution. The spatiotemporal evolution of wakefields in a plasma density up ramp is measured and the reversal of the plasma wake, where the wake wavelength at a particular point in space increases until the wake disappears completely only to reappear at a later time but propagating in the opposite direction, is observed for the first time by using this new technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗