Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA FOCUS DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Physical Reasoning to Synchronize Electrical Signals and Related Diagnostics in Plasma Focus Devices

Plasma Focus (PF) devices as well as other similar pulsed discharge devices requires a variety of diagnostics for their proper control and optimization, including the voltage between electrodes, the time derivative of the discharge current, detection of X-rays and neutron emissions, and pulsed laser images (Shadow, Schlieren, interferograms). This article discusses the problem of the time reference of all these outputs and proposes specific techniques for synchronizing them based on sound physical grounds. The foundations of synchronization criterion are verified in several experiments on PF devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of D-D Reaction at the Plasma Focus Device

The plasma focus device PF-1000 at IPPLM Warsaw with neutron yields of 10{sup 9}-10{sup 11} neutrons per shot is convenient for the determination of the axial neutron energy distribution in the fusion D-D reaction due to the horizontal position of a discharge axis and the distance of scintillation detectors up to 85 m from the neutron source in both axial (downstream and upstream) directions. In this paper the determination of the axial energy component of the fast deuterons producing neutrons is presented for the shot with a relative small neutron yield and nearly isotropic neutron energy distribution and the total energy of fast deuterons producing neutrons is estimated. We calculated, if the dense structure with the length of 2 cm and the density of 2xl0{sup 25} m{sup -3} could be the source of neutrons. We estimated the upper limit of energy of deuterons producing neutrons as 10-20 keV and their total number as 10{sup 18}. The deuterons with energies below 10-20 keV can't produce high number of neutrons due to the small cross-section of D-D reaction but they can be principally confined by magnetic field. We discuss the influence of magnetic field on the motion of deuterons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current and Perspective Applications of Dense Plasma Focus Devices

Dense Plasma Focus (DPF) devices' applications, which are intended to support the main-stream large-scale nuclear fusion programs (NFP) from one side (both in fundamental problems of Dense Magnetized Plasma physics and in its engineering issues) as well as elaborated for an immediate use in a number of fields from the other one, are described. In the first direction such problems as self-generated magnetic fields, implosion stability of plasma shells having a high aspect ratio, etc. are important for the Inertial Confinement Fusion (ICF) programs (e.g. as NIF), whereas different problems of current disruption phenomenon, plasma turbulence, mechanisms of generation of fast particles and neutrons in magnetized plasmas are of great interest for the large devices of the Magnetic Plasma Confinement--MPC (e.g. as ITER). In a sphere of the engineering problems of NFP it is shown that in particular the radiation material sciences have DPF as a very efficient tool for radiation tests of prospect materials and for improvement of their characteristics. In the field of broad-band current applications some results obtained in the fields of radiation material sciences, radiobiology, nuclear medicine, express Neutron Activation Analysis (including a single-shot interrogation of hidden illegal objects), dynamic non-destructive quality control, X-Ray microlithography and micromachining, and micro-radiography are presented. As the examples of the potential future applications it is proposed to use DPF as a powerful high-flux neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration for innovative experiments in nuclear physics, for the goals of radiation treatment of malignant tumors, for neutron tests of materials of the first wall, blankets and NFP device's constructions (with fluences up to 1 dpa per a year term), and ns pulses of fast electrons, neutrons and hard X-Rays for brachytherapy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Activation Technique and MCNP Calculations for Measurement of Fast Neutron Spatial Distribution at the MJ Plasma Focus Device

In this paper Plasma-Focus (PF) neutron emission properties have been studied using Monte Carlo calculations for neutron and photon transport. A Thermal Neutron Scaling Factor as a function of angular position of silver activation detectors placed around MJ Plasma Focus (PF-1000) device has been calculated. Detector responses calculated for 2.5 MeV neutrons and neutrons produced by Am-Be calibration source have been obtained .The results have shown the detector response dependence on the kind of calibration neutron source and on local geometrical/structural characteristics of the PF-1000 devices. Thus the proper calibration procedure ought to be performed for correct measurement of neutron yield within Plasma-Focus devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current sheath behavior and its velocity enhancement in a low energy Mather-type plasma focus device

The dynamics of the plasma sheath layer and its velocity enhancement have been studied in a low energy (4.9 kJ) Mather-type plasma focus device. Experiments were performed to study the effect of the Lorentz force variation on the current sheath expansion and movement, as well as the existence of traction between all parts of the sheath layer. Two different shape of anodes (cylindrical and step) along with an axial magnetic probe were used to investigate the effects of various experimental conditions, namely different charging voltages and gas pressures. In order to explore the upper limit of the current sheath velocity, a comparison has been made between the experimental data gathered by the probe and the Lee's computational model. The limitations governing the enhancement of the current sheath velocity that can lead to the deterioration of a good focusing phenomenon were also investigated. The increase of the current sheath velocity due to the usage of the step anode on ion generation and hard x-ray emissions have been demonstrated by means of an ion collector and a hard x-ray detector.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Results Of A 600 Joules Small Plasma Focus Device

Preliminary results of a 600 J (3.7 muF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0+-0.5 mubar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-to-Pinch Investigation of 5 kJ Mather-Type Plasma Focus Device

The Egyptian Atomic Energy Authority-Plasma focus (EAEA-PF2) has been upgraded to a 5 kJ plasma focus device. Its characteristics have been investigated at various pressures and different voltages in a 5 kJ Mather-type plasma focus device for Ar gas. Its time-to-pinch has been measured, simulated and analyzed at different operating conditions. It is observed from the results that, the time-to-pinch decreased when either the charging voltage increased or the gas pressure decreased. In addition, the time-to-pinch is estimated theoretically using Lee model RADPF5.15. A comparison between the experimental and theoretical time-to-pinch is discussed. Also, the drive factor of plasma focus is analyzed at different pressures and charging voltages. It is noticed that, the mass and current factors are affected by changing the pressure and voltage. Finally, it is observed that, the drive factor is proportional inversely to the pressure and directly to the charging voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

External circuit integration with electromagnetic particle in cell modeling of plasma focus devices

The pinch performance of a plasma focus (PF) device is sensitive to the physical conditions of the breakdown phase. It is therefore essential to model and study the initial phase in order to optimize device performance. An external circuit is self consistently coupled to the electromagnetic particle in cell code to model the breakdown and initial lift phase of the United Nations University/International Centre for Theoretical Physics (UNU-ICTP) plasma focus device. Gas breakdown during the breakdown phase is simulated successfully, following a drop in the applied voltage across the device and a concurrent substantial rise in the circuit current. As a result, the plasma becomes magnetized, with the growing value of the magnetic field over time leading to the gradual lift off of the well formed current sheath into the axial acceleration phase. This lifting off, with simultaneous outward sheath motion along the anode and vertical cathode, and the strong magnetic fields in the current sheath region, was demonstrated in this work, and hence validates our method of coupling the external circuit to PF devices. Our method produces voltage waveforms that are qualitatively similar to the observed experimental voltage profiles of the UNU-ICTP device. Values of the mean electron energy before and after voltage breakdown turned out to be different, with the values after breakdown being much lower. In both cases, the electron energy density function turned out to be non-Maxwellian.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast-Neutron Source Based on Plasma-Focus Device

This paper describes investigations of neutrons produced by small plasma focus device PF-6 operating in the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland. Main parameters of neutron radiation have been measured by scintillation probe, and by activation technique. Current derivative probe has also been applied to measure dI/dt signal. Simultaneously neutron transport calculations have been carried out by Monte Carlo method. Finally, experimental measurements and numerical calculations have allowed concluding that plasma focus devices can be useful pulse neutron sources for different applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Order of magnitude enhancement in x-ray yield at low pressure deuterium-krypton admixture operation in miniature plasma focus device

In a 200 J fast miniature plasma focus device about 17- and 10-fold increase in x-ray yield in spectral ranges of 0.9-1.6 keV and 3.2-7.7 keV, respectively, have been obtained with deuterium-krypton (D{sub 2}-Kr) admixture at operating pressures of {<=}0.4 mbar. In the pressure range of >0.4-1.4 mbar, about twofold magnification in average x-ray yield along with broadening of optimum pressure range in both spectral ranges were obtained for D{sub 2}-Kr admixtures. An order of magnitude enhancement in x-ray yields at low pressures for admixture operation will help in achieving high performance device efficiency for lithography and micromachining applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Nitrogen on Hydrogenated Amorphous Carbon Thin Films Deposited by Plasma Focus Device

To carry out our research, a plasma focus device is used to deposit thin films of nitrogen doped hydrogenated amorphous carbon (a-C:H:N) onto the stainless steel-AISI-304 substrates at room temperature. Thin films are deposited with the same numbers of focus shots, at the same distance from the anode tip and with different partial pressures of nitrogen in the mixtures of acetylene/nitrogen as working gas. The nitrogen contents of deposited films are studied using nuclear reaction analysis (NRA) techniques. The results prove that nitrogen contents of the samples do not increase significantly by increasing partial pressure of nitrogen of the working gas for both sets of the samples. Moreover, NRA results exhibit the limitation of nitrogen incorporated into the samples, when this experimental setup is used. G-peak position and peak intensity ratio of the D-band to G-band (I{sub D}/I{sub G}) are used to investigate the diamond characters. Also, they show that sp{sup 2} clustering is highly dependent on the nitrogen atomic contents and angular position of the samples. Scanning electron microscopy (SEM) shows the granular surface morphology of the films. Furthermore, it shows that angular position of the samples with respect to the anode axis plays an important role in the grain size of the surface of the samples. The thickness of the films decreases significantly by increasing angular position of the samples, while it decreases slightly by increasing partial pressure of nitrogen of the working gas. The Vickers surface hardness of the thin films exhibits significant dependency on the sp{sup 2} clustering.

36 MATERIALS SCIENCE↗

Scaling, stability, and fusion mechanisms. Studies using plasma focus devices from tens of kilojoules to tenth of joules

Fusion studies using plasma focus devices from tens of kilojoules to less than one joule performed at the Chilean Nuclear Energy Commission are presented. The similarity of the physical behavior and the scaling observed in these machines are emphasized. Experiments on actual devices show that scaling holds at least through six order of magnitude. In particular all of these devices, from the largest to the smallest, keep the same quantity of energy per particle. Therefore, fusion reactions are possible to be obtained in ultraminiature devices (driven by generators of 0.1 J), as they are in the bigger devices (driven by generators of 1 MJ). However, the stability of the plasma depends on the size and energy of the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interaction of the high energy deuterons with the graphite target in the plasma focus devices based on Lee model

Numerical experiments are systematically carried out using the Lee model code extended to compute the ion beams on various plasma focus devices operated with Deuterium gas. The deuteron beam properties of the plasma focus are studied for low and high energy plasma focus device. The energy spectral distribution for deuteron ions ejected from the pinch plasma is calculated and the ion numbers with energy around 1 MeV is then determined. The deuteron–graphite target interaction is studied for different conditions. The yield of the reaction {sup 12}C(d,n){sup 13}N and the induced radioactivity for one and multi shots plasma focus devices in the graphite solid target is investigated. Our results present the optimized high energy repetitive plasma focus devices as an alternative to accelerators for the production of {sup 13}N short lived radioisotopes. However, technical challenges await solutions on two fronts: (a) operation of plasma focus machines at high rep rates for a sufficient period of time (b) design of durable targets that can take the thermal load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron production from puffing deuterium in plasma focus device

The current research has continued on the PF-1000 plasma focus device at the current of 2 MA by comparison of the shots with and without injected deuterium. The increase of the total neutron yield at the level of 10{sup 10}–10{sup 11} per shot was achieved after the compression of about 10 μg/cm of the deuterium from the gas-valve by about 46 μg/cm of the neon or deuterium plasma sheath. It increases five times at the decrease of the puffing deuterium mass to one-half. In shots with neon in the chamber and with puffing deuterium, a considerable decrease was confirmed of the soft X-ray emission in comparison with shots without deuterium injection. This decrease can be explained by the absence of the neon in the region of the compressed and hot plasma. The deuterium plasma from the gas-puff should then be confined in the internal structures both in the phase of implosion as well as during their formation and transformation. In shots with puffing deuterium, the evolution of instabilities in the plasma column was suppressed. The deuterium plasma has a higher conductance and better ability to form expressive and dense plasmoids and to transport the internal current in comparison with neon plasma. Neutrons were produced both at the initial phase of stagnation, as well as at a later time at the evolution of the constrictions and dense plasmoids.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative study of radiation emission without and with target in a 2.2 kJ plasma focus device

The radiation emission in a 2.2 kJ Mather-type dense plasma focus device is investigated using a five channel BPX65 PIN diode spectrometer. Estimated X-ray associated with the hollow anode without and with target in Argon gas medium is compared. At optimum conditions, the radiation emission from the system is found to be strongly influenced with target in hollow anode and the filling gas pressure. The maximum X-ray yield in 4π sr was obtained in case of hollow anode in argon gas medium with target 'Lead' due to interaction of electron beam. Results indicated that an appropriate design of hollow anode with target could enhance the radiation emission by more intense interaction of expected electron beam with target. The outcomes are helpful in designing a plasma focus with enhanced X-ray radiation with improved shot to shot reproducibility in plasma focus device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation Characteristics of the FN-II Dense Plasma Focus Device

The Fuego Nuevo II (FN-II) dense plasma focus device is a small machine (4.6 kJ), operating at the Instituto de Ciencias Nucleares, UNAM, in which neutrons, as well as soft and hard X rays have been studied with a number of diagnostics. Neutrons are studied with silver activation counters, and scintillator-photomultiplier detectors, while their angular distribution inside and outside the discharge chamber have been studied with CR-39 plastic track detectors. The soft X rays are studied with a multiple-pin-hole camera and PIN diodes, while the hard X-rays are observed with the scintillator-photomultiplier detectors mentioned above. When a needle is inserted on the inner electrode, a bright spot of hard x-rays can be concentrated, and used for the production of high-contrast radiography. Dosimetric measurements have been made for X-rays crossing a 300 micron aluminum window, through the axis of the machine, showing an average dose of 0.11{+-}0.01 mGy per shot. In contrast, the average dose with a hollow cathode is 0.077{+-}0.006 mGy per shot.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on neutron emission from 2.2 kJ plasma focus device

The neutron emission from a low energy (2.2 kJ) plasma focus device operated in deuterium medium has been investigated by employing photo-multiplier tube (PMT) and bubble dosimeter. The neutron emission is found to be pressure dependent and anisotropic in nature. In most cases of plasma focus shots, the PMT signal shows double pulses of neutron emission with different intensities and widths. An interesting relation between intensity of hard X-ray and neutron emission is also observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Characteristics of Four Small Dense Plasma Focus Devices

Four small (in the energy range 2-7 kJ) dense plasma focus devices were elaborated and put into operation in the last several years: ING-103, DPF-10, PF-5M, and DPF-6. Each device has its own parameters (energy, current rise-time and magnitude, pulse duration of ionizing radiation of different types, weight, etc.) and together with the specific discharge chambers they are optimized for various applications. Comparative description of functioning parameters of these devices together with the results of the most successful applications is presented in the report.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗