Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PIXE ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PIXE analysis of medieval silver coins

We applied the proton-induced X-ray emission (PIXE) analytical technique to twenty-eight medieval silver coins, selected from the Tunisian treasury. The purpose is to study the fineness evolution from the beginning of the 7th to the 15th centuries AD. Each silver coin was cleaned with a diluted acid solution and then exposed to a 3 MeV proton beam from a 1.7 MV tandem accelerator. To allow the simultaneous detection of light and heavy elements, a funny aluminum filter was positioned in front of the Si(Li) detector entrance which is placed at 135{sup o} to the beam direction. The elements Cu, Pb, and Au were observed in the studied coins along with the major component silver. The concentration of Ag, presumably the main constituent of the coins, varies from 55% to 99%. This significant variation in the concentration of the major constituent reveals the economical difficulties encountered by each dynasty. It could be also attributed to differences in the composition of the silver mines used to strike the coins in different locations. That fineness evolution also reflects the poor quality of the control practices during this medieval period. In order to verify the ability of PIXE analytical method to distinguish between apparently similar coins, we applied hierarchical cluster analysis to our results to classify them into different subgroups of similar elemental composition.

36 MATERIALS SCIENCE↗

On the Applications of IBA Techniques to Biological Samples Analysis: PIXE and RBS

The analytical techniques based on ion beams or IBA techniques give quantitative information on elemental concentration in samples of a wide variety of nature. In this work, we focus on PIXE technique, analyzing thick target biological specimens (TTPIXE), using 3 MeV protons produced by an electrostatic accelerator. A nuclear microprobe was used performing PIXE and RBS simultaneously, in order to solve the uncertainties produced in the absolute PIXE quantifying. The advantages of using both techniques and a nuclear microprobe are discussed. Quantitative results are shown to illustrate the multielemental resolution of the PIXE technique; for this, a blood standard was used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RBS and PIXE analysis of chlorine contamination in ALD-Grown TiN films on silicon

The performance, strengths and limitations of RBS and PIXE for the characterization of trace amounts of Cl in TiN thin films are critically compared. The chlorine atomic concentration in ALD grown TiN thin films on Si is determined for samples grown at temperatures ranging from 350 Degree-Sign C to 550 Degree-Sign C. We show that routine Rutherford backscattering spectrometry measurements (1.5 MeV He{sup +}) and PIXE measurements (1.5 MeV H{sup +}) on 20 nm thick TiN films allow one to determine the Cl content down to 0.3 at% with an absolute statistical accuracy reaching 0.03 at%. Possible improvements to push the sensitivity limit for both approaches are proposed.

36 MATERIALS SCIENCE↗

PIXE Analysis of Metal Hull Bolts From HMB DeBraak

HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium, tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PIXE ANALYSIS ON AN ANCIENT SCROLL SAMPLE

For years, scientists have developed several new techniques to read texts of Herculaneum scrolls without destroying them. Recently, the use of a custom built high-resolution CT scanner was proposed to scan and then virtually unroll the scrolls for reading. Identification of any unique chemical signatures in the ancient ink would allow better calibration of the CT scanner to improve the chances of resolving the ink from the burned papyrus background. To support this effort, we carried out one pilot study to see whether the composition of the ink can be obtained from an ancient scroll sample using PIXE technique. PIXE data were collected and analyzed in two different regions of the ancient scroll sample (ink and blank regions). This preliminary work shows that elemental distributions from the ink used in this scroll mainly contained Al, Fe and Ti as well as minor trace amounts of Cr, Cu and Zn.

Environmental Molecular Sciences Laboratory↗

IBIXFIT: A Tool For The Analysis Of Microcalorimeter PIXE Spectra

PIXE analysis software has been for long mainly tuned to the needs of Si(Li) detector based spectra analysis and quantification methods based on K{sub {alpha}} or L{sub {alpha}} X-ray lines. Still, recent evidences related to the study of relative line intensities and new developments in detection equipment, namely the emergence of commercial microcalorimeter based X-ray detectors, have brought up the possibility that in the near future PIXE will become more than just major lines quantification. A main issue that became evident as a consequence of this was the need to be able to fit PIXE spectra without prior knowledge of relative line intensities. Considering new developments it may be necessary to generalize PIXE to a wider notion of ion beam induced X-ray (IBIX) emission, to include the quantification of processes such as Radiative Auger Emission. In order to answer to this need, the IBIXFIT code was created based much on the Bayesian Inference and Simulated Annealing routines implemented in the Datafurnace code [1]. In this presentation, the IBIXFIT is used to fit a microcalorimeter spectrum of a Ba{sub x}Sr{sub (1-x)}TiO{sub 3} thin film sample and the specific possibility of selecting between fixed and free line ratios combined with other specificities of the IBIXFIT algorithm are shown to be essential to overcome the problems faced.

74 ATOMIC AND MOLECULAR PHYSICS↗

Status of ion sources at National Institute of Radiological Sciences

The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ion radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.

07 ISOTOPE AND RADIATION SOURCES↗

A PIXE Study of Trace Elements in Sediments of Toledo River, Parana, Brazil

In this work we characterize sediment samples from several points in the River Toledo--PR, using the PIXE (Particle Induced X-Ray Emission) spectroscopy technique, in order to quantify trace elements in these samples aiming to provide information about pollution levels for trace elements. The samples were collected in six points of river, during a period of twelve months (12/2001 to 11/2002). The collected material was air-dried at room temperature and then pressed in pellets. The samples were irradiated under vacuum using a H beam of 2,39 MeV in the LAMFI (Laboratorio de Analises de Materials por Feixe Ionico). Produced x-rays were detected using a Si(Li) detector and a standard electronics. Using the Axil program to analyze PIXE spectra it was possible to identify and quantify some elements present in the samples. A multi-elemental referenced material (Buffalo River sediment--RM 8704) was used to validate the PIXE analysis with thick targets. Twelve months of monitoring of six river points were analyzed and these allowed us to identify 18 elements such as Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr e Pb. The following elements were monitored: V, Cr, Mn, Co, Ni, Cu, Zn e Pb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elemental X-ray Imaging Using the Maia Detector Array: The Benefits and Challenges of Large Solid-Angle

The fundamental parameter method for quantitative SXRF and PIXE analysis and imaging using the dynamic analysis method is extended to model the changing X-ray yields and detector sensitivity with angle across large detector arrays. The method is implemented in the GeoPIXE software and applied to cope with the large solid-angle of the new Maia 384 detector array and its 96 detector prototype developed by CSIRO and BNL for SXRF imaging applications at the Australian and NSLS synchrotrons. Peak-to-background is controlled by mitigating charge-sharing between detectors through careful optimization of a patterned molybdenum absorber mask. A geological application demonstrates the capability of the method to produce high definition elemental images up to {approx}100 M pixels in size.

43 PARTICLE ACCELERATORS↗

Characterization of Aerosols Containing Zn, Pb, and Cl from an Industrial Region of Mexico City

During the March, 2006 MILAGRO campaign, measurements in the Northern Mexico City Metropolitan Area revealed the frequent appearance of particles with a characteristically high content of internally mixed Zn, Pb, Cl, and P. A comprehensive study of the chemical and physical properties of these particles was performed using a complementary combination of aerosol measurement techniques. Individual particles were analyzed using Aerosol Time-of-Flight Mass Spectrometry (ATOFMS) and Computer Controlled Scanning Electron Microscopy/Energy Dispersive X-Ray spectroscopy (CCSEM/EDX). Proton Induced X-Ray Emission (PIXE) analysis of bulk aerosol samples provided time-resolved mass concentrations of individual elements. The PIXE measurements indicated that Zn is more strongly correlated with Cl than with any other element and that Zn concentrations are higher than other non-ferrous transition metals. The Zn- and Pb - containing particles have both spherical and non-spherical morphologies. Many metal rich particles had needle-like structures and were found to be composed of ZnO and/or Zn(NO 3 ) 2 ∙6H 2 O as indicated by scanning transmission x-ray microscopy/near edge X-ray absorption spectroscopy (STXM/NEXAFS). The Zn and Pb rich particles were primarily in the submicron size range and internally mixed with elemental carbon. The unique chemical associations most closely match signatures acquired for garbage incineration. This unique combination of complementary analytical techniques has allowed for a comprehensive evaluation of Zn- and Pb- containing particles in a complex urban environment, highlighting unique characteristics that give powerful insight into their origin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Need for portable accelerators in cultural heritage

Ion Beam Accelerators (IBA) centres have provided researchers with powerful techniques to analyse objects of cultural significance in a non-destructive and non-invasive manner. However, in some cases it is not feasible to remove an object from the field or museum and transport it to the laboratory. In this contributed talk, we present as a manner of a short review, examples of the benefits provided from these techniques in the study of material culture and discuss the initial steps to consider when investigating the feasibility of a compact accelerator that can be taken to sites of cultural significance for PIXE analysis. In particular, we consider the application of a compact, robust 2 MeV proton accelerator that can be taken into the field to perform PIXE measurements on rock art. We detail the main challenges and considerations for such a device.

Charles, T. K.↗

Nuclear Analytical Applications within the IAEA Nuclear Data Section

The Nuclear Data Section, International Atomic Energy Agency, supports Member States development of nuclear techniques through a number of targeted actions and projects. The Section fulfills this role by organizing Coordinated Research Projects, or through less formal Data Development Projects and/or Technical Meetings. Training workshops are also regularly organized in conjunction with the International Centre for Theoretical Physics (ICTP), Trieste, Italy. A number of projects relating to materials analysis techniques have been recently undertaken, e.g. neutron activation analysis, ion beam analysis, and proton induced X- or {gamma}-ray emission. In particular, details of the Coordinated Research Project focusing on the nuclear data requirements for the k{sub 0} method of neutron activation analysis are given. The paper illustrates how the IAEA strives to bring together relevant partners and provides a unique and structured basis for international collaboration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative Analysis of Urban Atmospheric Aerosol by Particle-Induced X-ray Emission (PIXE), Proton Elastic Scattering Analysis (PESA), and Aerosol Mass Spectrometry (AMS)

A multifaceted approach to atmospheric aerosol analysis is often desirable in field studies where an understanding of technical comparability among different measurement techniques is essential. Herein we report quantitative intercomparisons of Particle-Induced X-ray Emission (PIXE) and Proton Elastic Scattering Analysis (PESA), performed off-line under vacuum, with analysis by Aerosol Mass Spectrometry (AMS) carried out in real-time during the MCMA-2003 Field Campaign in the Mexico City Metropolitan Area. Good agreement was observed for mass concentrations of PIXE-measured sulfur (assuming it was dominated by SO 4 2- ) and AMS-measured sulfate during the most of the campaign. PESA-measured hydrogen mass was separated into sulfate H and organic H mass fractions assuming the only major contributions were (NH 4 ) 2 SO 4 and organic compounds. Comparison of the organic H mass with AMS organic aerosol measurements indicates that about 75% of the mass of these species evaporated under vacuum. However ~25% of the organics does remain under vacuum, which is only possible with low vapor pressure compounds, and which supports the presence of high molecular weight and/or highly oxidized organics consistent with atmospheric aging. Approximately 10% of the chloride detected by AMS was measured by PIXE, possibly in the form of metal-chloride complexes, while the majority of Cl was likely present as more volatile species including NH 4 Cl. This is the first comparison of PIXE/PESA and AMS, and to our knowledge also the first report of PESA hydrogen measurements for urban organic aerosols.

08 HYDROGEN↗

Composition and Characteristics of Aerosols in the Southern High Plains of Texas (USA)

Aerosol samples on polycarbonate filters were collected daily for several years in the Southern High Plains region of western Texas. Selected samples representing a variety of size modes, locations, and air quality conditions were analyzed by PIXE. Silicon and other crustal elements dominated during dust storms and in the coarse mode; sulfur dominated during anthropogenic pollution episodes and in the fine mode. A mixture of both aerosol types was present even during 'clear' conditions. The Al/Si ratio in dust events increases with wind speed. These data provide an initial assessment of aerosol chemistry in the West Texas plains.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regional PIXE facility at Chandigarh (India) and Trace Element Analysis of Aerosol and Bio-medical Samples

A regional Proton induced X-ray Emission (PIXE) facility is newly developed using 3 Mev Proton beam from Variable Energy Cyclotron, Panjab University, Chandigarh (India). A new target chamber has been designed to cater for Proton Induced Gamma Emission (PIGE) and Rutherford Back Scattering (RBS) along with PIXE measurements. The HPGe x-ray detector, the Ge (Li) gamma-ray detector and a silicon surface barrier (SSB) detector can be mounted simultaneously in the chamber for this purpose. A remotely controlled stepper motor is provided to move the target wheel holding 12/24 samples at a time. This facility is now routinely used for the detection of trace elements in the aerosol, medical and forensic science samples. The paper presents the analysis of Aerosol samples collected from highly polluted steel city of Mandi Govindgarh in Punjab state and relatively clean city of Jammu in Jammu and Kashmir region. The results from the analysis of these samples show some basic differences in the trace element profile of the two cities. The paper also describes the trace element analysis of fly ash in the vicinity of Ropar Thermal Power plant in Punjab. The scope of this study was to determine the concentration and composition of atmospheric particulate matter (PM) in the vicinity of coal-fired thermal power plants in India. The data taken for the Bio-medical samples are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elemental Analysis of Beryllium Samples Using a Microzond-EGP-10 Unit

Results concerning the structural and elemental analysis of beryllium samples obtained via different technologies using a Microzond-EGP-10 unit with the help of the PIXE and RBS methods are presented. As a result, the overall chemical composition and the nature of inclusions were determined. The mapping method made it possible to reveal the structural features of beryllium samples: to select the grains of the main substance having different size and chemical composition, to visualize the interfaces between the regions of different composition, and to describe the features of the distribution of impurities in the samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Energy PIXE at the ARRONAX Facility for Multi Elemental Analysis of Thick Samples

Proton Induced X-ray Emission (PIXE) using high energy protons is a nondestructive multi-elemental technique that can analyze medium and heavy trace elements on thick samples. A new experimental setup is being built at the ARRONAX facility (Nantes, France) for this purpose. Experiments on multi-layer targets have been made in order to identify the sequences and to measure the different layer thicknesses. Our approach is to consider the relative intensities of K{alpha}/K{beta} lines in different layers as well as the gamma intensity ray ratio from each layer versus the reference layer. Two multi-layer targets were used: the first one composed of 10 {mu}m Au, 30{mu}m Bi and 250 {mu}m Cu, and the second composed of 125 {mu}m Ti, 10 {mu}m Au and 50 {mu}m Ag. In both cases, we used Al 100 {mu}m as a reference layer. This work emphasizes the importance of having both X-ray and gamma-ray information in multi-layer analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗