2013 Pittsburgh Energy & Emissions Baseline: Examining Pittsburgh’s Energy Use to Inform Regional Innovation
Presented by NETL at Pittsburgh 2030 District Partners Meeting, 05/17
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Presented by NETL at Pittsburgh 2030 District Partners Meeting, 05/17
Measurements of sulfuric acid (H 2 SO 4 ) and sulfur trioxide (SO 3 ) were conducted in Pittsburgh, Pennsylvania, during field campaigns in Fall 2023 and Fall 2024. These measurements identified nocturnal concentrations of H 2 SO 4 comparable to those of daytime values. Nocturnal H 2 SO 4 concentrations were observed to increase by 5 × 10 5 to 5 × 10 7 molecules cm –3 above background on 16 of the 31 measurement nights. The median peak concentration during events was 6.5 × 10 6 molecules cm –3 , with a maximum of 1.0 × 10 8 molecules cm –3 , exceeding previously reported nighttime concentrations. Increases in H 2 SO 4 concentrations were positively correlated with the anomalously high SO 3 concentrations and condensation sink rates, indicating that the formation of H 2 SO 4 increased to overcome the loss rates to particles. Increases in particulate mass and the mass fraction of metals commonly emitted from coal combustion and steel production were also observed. The air masses were traced back to the southeast of Pittsburgh, a region home to a steel mill, coke plant, and a steel processing plant. The observations indicate a previously unrecognized nighttime formation pathway for H 2 SO 4 , potentially from heterogeneous catalysis with metal or black carbon, originating from steel and coke plant emissions. Further measurements are needed to identify key compounds and chemical processes driving these increases in nocturnal H 2 SO 4 concentrations.
Particle size distributions are used to calculate nucleation rates during new particle formation (NPF). However, the low time resolution and poor sensitivity of instruments deployed to observe particle size distributions can lead to inaccurate estimates of nucleation rates. We calculated nucleation rates in Pittsburgh, PA from particle size distributions measured with the new high time resolution Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM) and from gas precursor concentrations measured with a chemical ionization mass spectrometer. The CPC FARM nucleation rates were calculated by examining the appearance rate of particles in the smallest size bin at 1.6 nm. The nucleation rate of 1.6 nm determined every second resulted in positive and negative rates, indicating the influence of inhomogeneous mixing and advection of precursor gases and clusters. These effects are not currently considered when estimating nucleation rates from measurements. The nucleation rates from the CPC FARM were compared to the nucleation rates determined from a transient acid‐base reaction model using measured sulfuric acid concentration, strong base concentrations, and CPC detection efficiencies. The transient form of the model allowed the advection of heterogeneously mixed precursors to influence the nucleation rate. Good agreement between particle and gas‐based nucleation rates is observed during sulfuric acid‐driven NPF events. This study demonstrates that high time resolution measurements of short‐lived and rapidly formed particles are needed to accurately capture nucleation rates, which are likely influenced by advection of nucleation precursors and clusters in heterogeneous environments such as urban areas.
The Pittsburgh International Airport (PIT)—with the Allegheny County Airport Authority (which manages PIT)—has established itself as a leader in resiliency by becoming the first major United States (U.S.) airport to have a self-sustaining microgrid, providing electricity, heating, and cooling for airport operations. The microgrid is powered by natural gas and solar power produced on the airport property and was completed in Summer 2021. This study examines the feasibility of producing jet fuel at the airport to provide a secure supply of aviation fuel, furthering PIT’s ability to weather supply disruptions and operate self-sufficiently. Gas-to-liquids (GTL) is a commercially available technology that converts natural gas to liquid hydrocarbons, including synthetic jet fuel. A GTL facility at PIT could convert natural gas from onsite wells to jet fuel, effectively doubling the onsite fuel stores in the event of a supply disruption. Moreover, GTL provides a pathway to renewable jet fuel production and reduced greenhouse gas (GHG) emissions from the aviation sector, particularly if renewable natural gas (RNG) is used as a feedstock or other renewable energy sources are used for energy inputs. This study has found that it would be technically feasible to construct and operate a GTL facility on PIT’s property. The approximately 6,000-barrel per day (BPD) facility evaluated would produce nearly 70 million (MM) gallons (gal) of synthetic jet fuel per year, which could supplant nearly all (85 percent) current jet fuel consumption at PIT. Given the current blend limitation of 50 percent Fischer-Tropsch fuels by volume, the plant would have excess production capacity available for the United States Air Force (USAF) Pittsburgh Air Reserve Station and the USAF 171st Air Refueling Wing co-located at the airport.
This brochure provides an overview of the challenges and successes of Pittsburgh, PA, a 2007 Solar America City awardee, on the path toward becoming a solar-powered community. Accomplishments, case studies, key lessons learned, and local resource information are given.
Climate-induced extreme weather events, such as floods and heatwaves, pose significant challenges to the resilience of urban power distribution grids. This paper examines the outage and restoration dynamics of Pittsburgh's power grid during the flood event in April 2024 and three heatwaves in June, July, and August 2024. We introduce a comprehensive modeling framework that integrates outage and restoration processes, enabling the quantification of resilience metrics, including total customer-hours of power outage, maximum residual values, and restoration durations across various ZIP codes. Our analysis highlights spatial disparities in outage impacts and restoration efficiencies, with ZIP Code 15222 experiencing the highest cumulative disruptions, while ZIP Code 15217 shows lower susceptibility. By linking statistical trends with weather events, this study underscores the critical need for targeted infrastructure upgrades and advanced restoration strategies. Furthermore, the proposed framework offers valuable insights for planning and managing resilient power systems in the face of increasing climate stress.
Field testing was performed in a new construction unoccupied test house in Pittsburgh, Pennsylvania. Four air-based heating, ventilation, and air conditioning distribution systems--a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms--were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.
Field testing was performed in a new construction unoccupied test house in Pittsburgh, PA. Four air-based heating, ventilation, and air conditioning distribution systems—a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms—were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.
The United States (U.S.) Department of Energy (DOE) and the National Energy Technology Laboratory (NETL) are working in conjunction with the City of Pittsburgh (City) to transform how energy is produced, transported, and consumed in the City. This transformation will rely on 21st Century Energy Infrastructure designs, which leverage advanced technology and design techniques to modernize energy infrastructure, create new business models and markets, and expand technology research and development opportunities. Achieving this vision will require developing solutions that are unique to the City: its climate, topography, energy needs, resources, and existing infrastructure.a In this way, the City will demonstrate what the American “City of the Future” looks like, with all its attendant environmental, economic, and job-creation benefits. It will also serve as a template for other cities seeking to reinvent their energy systems.
This study examines energy consumption patterns within the Pittsburgh metropolitan area to establish a baseline for energy consumption and associated air emissions. Monthly electricity and natural gas consumption for the residential, commercial, and industrial sectors is reported at the zip code-level, utilizing 2013 utility data (the last complete year available). Electricity load profiles for the Duquesne Light service territory are also reported, examining hourly, daily, and monthly load trends. These data were then utilized to identify trends in consumption, emissions associated with different sectors and fuel types, and potential opportunities for improvement.
Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies that improve housing conditions and lower energy bills, incorporate energy efficiency and renewable energy strategies into existing, community-driven development efforts; and generate quality local jobs. This presentation provides a summary of potential employment impacts of residential energy efficiency investments in the Hill District, aligned with NREL's housing stock analysis; a scan of existing energy efficiency and clean energy workforce and education stakeholders in and around the Hill District; and gaps and potential opportunities for new or expanded training to align with energy efficiency and clean energy goals.
In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. Four air-based HVAC distribution systems were assessed:-a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.
In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania, to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. The team evaluated a market-available through-wall air transfer fan system that provides air to the bedrooms.The relative ability of this system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability.
Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies. This report summarizes the insights from stakeholder engagement with organizations that provide home repair services, weatherization, and residential energy efficiency in the Hill District as well as from a building analysis to characterize Hill District housing stock and the potential costs and benefits of energy efficiency and electrification measures.
On September 8, 1994, a Boeing 737-300 passenger airplane was on a downwind approach to the Pittsburgh International Airport at an altitude of 5000 feet above ground level (6000 feet MSL). While in a shallow left turn onto a downwind approach heading, the airplane crossed into the vortex trail of a Boeing 727 flying in the same approach pattern about 4 miles ahead. The B-737 airplane rolled and turned sharply to the left, exited the vortex wake and plunged into the ground. Weather was not a factor in the accident. The airplane was equipped with a 11+ channel digital Flight Data Recorder (FDR) and a multiple channel Cockpit Voice Recorder (CVR). Both recorders were recovered from the crash site and provided excellent data for the development of an accident scenario. Radar tracking of the two airplanes as well as the indicated air speed (IAS) perturbations clearly visible on the B-737 FDR recordings indicate that the upset was apparently initiated by the airplane's crossing into the wake of the B-727 flying ahead in the same traffic pattern. A 6 degree-of-freedom simulation program for the B-737 airplane using MATLAB and SIMULINK was constructed. The simulation was initialized at the stabilized flight conditions of the airplane about 13 seconds prior to its entry into the vortex trail of the B-727 airplane. By assuming a certain combination of control inputs, it was possible to produce a simulated motion that closely matched that recorded on the FDR.
For more than a decade, the Sleep and Chronobiology Center (SCC) at the University of Pittsburgh has received funding from the National Institute on Aging (NIA), the National Institute of Mental Health (NIMH) and the National Aeronautics and Space Administration (NASA) in order to study the sleep and circadian rhythms of healthy older people, as well as the sleep and circadian rhythms of astronauts and cosmonauts. We have always been struck by the strong synergism between the two endeavors. What happens to the sleep and circadian rhythms of people removed from the terrestrial time cues of Earth is in many ways similar to what happens to people who are advancing in years. Most obviously, sleep is shorter and sleep depth is reduced, but there are also more subtle similarities between the two situations, both in circadian rhythms and in sleep, and in the adaptive strategies needed to enhance 24h zeitgebers.
Increasingly, there is a need in both research and clinical practice to document and quantify sleep and waking behaviors in a comprehensive manner. The Pittsburgh Sleep Diary (PghSD) is an instrument with separate components to be completed at bedtime and waketime. Bedtime components relate to the events of the day preceding the sleep, waketime components to the sleep period just completed. Two-week PghSD data is presented from 234 different subjects, comprising 96 healthy young middle-aged controls, 37 older men, 44 older women, 29 young adult controls and 28 sleep disorders patients in order to demonstrate the usefulness, validity and reliability of various measures from the instrument. Comparisons are made with polysomnographic and actigraphic sleep measures, as well as personality and circadian type questionnaires. The instrument was shown to have sensitivity in detecting differences due to weekends, age, gender, personality and circadian type, and validity in agreeing with actigraphic estimates of sleep timing and quality. Over a 12-31 month delay, PghSD measures of both sleep timing and sleep quality showed correlations between 0.56 and 0.81 (n = 39, P < 0.001).
The National Energy Technology Laboratory has established an agreement to help the City of Pittsburgh improve its energy infrastructure.