Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PHOTOMULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of the timing properties of the new Philips components (Amperex) XP2020/UR photomultiplier and the XP2020 photomultiplier

Timing characteristics are measured for the Philips Components (Amperex) XP2020/UR photomultiplier. The transit time jitter is significantly better than that of previously available XP2020 tubes. In a study of the transit time jitter, a single photoelectron resolution of 286 +/-3 ps was obtained for the XP2020 and 190 +/-2 ps for the XP2020/UR.

Kuhlen, M.

Evaluation of the amperex 56 TVP photomultiplier

Characteristics were measured for the Amperex 56 TVP 42 mm-diameter photomultiplier. Some typical photomultiplier characteristics-such as gain, dark current, transit and rise times-are compared with data provided. Photomultiplier characteristics generally not available such as the single photoelectron time spread, the relative collection efficiency, the relative anode pulse amplitude as a function of the voltage between the photocathode and focusing electrode, and the position of the photocathode sensing area were measured and are discussed for two 56 TVP's. The single photoelectron time spread, the relative collection efficiency, and the transit time difference as a function of the voltage between photocathode and focusing electrode were also measured and are discussed, particularly with respect to the optimization of photomultiplier operating conditions for timing applications.

Lo, C. C.

Characterization of gigahertz (GHz) bandwidth photomultipliers

The average impulse response, root-mean-square times jitter as a function of signal level, single photoelectron distribution, and multiphotoelectron dark-count distribution have been measured for two static crossed-field and five electrostatic photomultipliers. The optical signal source for the first three of these tests was a 30 picosecond mode-locked laser pulse at 0.53 micron. The static crossed-field detectors had 2-photoelectron resolution, less than 200 ps rise times, and rms time jitters of 30 ps at the single photoelectron level. The electrostatic photomultipliers had rise times from 1 to 2.5 nanoseconds, and rms time jitters from 160 to 650 ps at the same signal level. The two static crossed-field photomultipliers had ion-feedback-generated dark pulses to the 50-photoelectron level, whereas one electrostatic photomultiplier had dark pulses to the 30-photoelectron level.

Abshire, J. B.

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele

Compact photomultiplier housing with controlled cooling.

Description of a compact photomultiplier housing which can provide controlled cooling to the photomultiplier tube down to -90 C. The cooling is accomplished by flowing liquid nitrogen cooled helium gas through a series of coils which envelop the photocathode portion of the tube. The temperature is controlled by controlling the flow of the gas with a fine adjustable needle valve. The temperature is measured near the photocathode of the photomultiplier by a calibrated thermistor.

SHARDANAND

Gated photomultiplier response characterization for DIAL measurements

The characteristics of various detector responses are studied to understand the cause of various systematic biases and to minimize these undesirable effects in measurements of transient signals with large dynamic range. Signal-induced bias, gain variation, and the linearity of commonly used gated photomultipliers in the current integrating mode are quantitatively evaluated. Analysis of the results indicates that impurity ions inside the photomultiplier tubes (PMT) are the source of the signal induced bias and gain variation. Two different PMTs used in this study show significant differences in the magnitude and decay behavior of signal-induced bias. It was found that it can be minimized by using an external amplifier to reduce PMT gain, and by applying a low potential between the cathode and first dynode. The linearity of a PMT is also studied over a large dynamic range of input intensities employing a new technique which does not require an absolute calibration. The result of this study shows that the photomultiplier response is linear only for a limited input intensity range below a certain anode current.

Lee, H. Sang

Optical characterization of deep-level defects in n-type Al x In y Ga 1- x - y P for the development of solid-state photomultiplier analogs

Characterizing intrinsic defects is an essential step in evaluating materials for novel optoelectronic device applications. For photomultipliers, suppressing dark currents is critical, but a tradeoff is present between maximizing the band gap while remaining sensitive to the wavelength of interest and minimizing the incorporation of fresh defects by growing not-yet-optimized alloys. We present a series of capacitance-based measurements, including deep-level optical spectroscopy, steady-state photocapacitance, and illuminated capacitance-voltage, on photodiodes with lightly n-type Al x In y Ga 1−x−y P absorber regions. Several deep levels are identified, including one near the midgap. Although the inclusion of aluminum increases each trap density by approximately 10×, the hole capture cross-section also appears to decrease, suggesting that Shockley–Read–Hall dark currents may be suppressed. These materials may be good candidates for the development into silicon photomultiplier analogs with a wider bandgap for scintillator applications.

III–V

Fluorescence and phosphorescence of photomultiplier window materials under electron irradiation

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation were investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV grade, optical grade, and electron-irradiated samples of MGF2 and LiF, CaF2, BaF2, sapphire, fused silica, and UV transmitting glasses were obtained over the spectral range of 200 nm to 650 nm. Fluorescence yields, expressed as the number of counts in a solid angle of 2 pi steradian per 1MeV of incident electron energy deposited, were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively.

Viehmann, W.

Photomultiplier window materials under electron irradiation - Fluorescence and phosphorescence

The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation have been investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV-grade, optical-grade, and electron-irradiated samples of MgF2 and LiF, and of CaF2, BaF2, sapphire, fused silica, and UV-transmitting glasses were obtained over the 200-650-nm spectral range. Fluorescence yields were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively. Optical-grade MgF2 and LiF, as well as electron-irradiated UV-grade samples of these two materials, show enhanced fluorescence due to color-center formation and associated emission bands in the blue and red wavelength regions. Large variations in fluorescence intensities were found in UV-grade sapphire samples of different origins, particularly in the red end of the spectrum, presumably due to various amounts of chromium-ion content. Phosphorescence decay with time is best described by a sum of exponential terms, with time constants ranging from a few minutes to several days.

Viehmann, W.

A system for measuring the pulse height distribution of ultrafast photomultipliers

A system for measuring the pulse height distribution of gigahertz bandwidth photomultipliers was developed. This system uses a sampling oscilloscope as a sample-hold circuit and has a bandwidth of 12 gigahertz. Test results are given for a static crossed-filed photomultiplier tested with a demonstration system. Calculations on system amplitude resolution capabilities are included for currently available system components.

Abshire, J. B.

Systems for measuring response statistics of gigahertz bandwidth photomultipliers

New systems have been developed for measuring the average impulse response, the pulse-height spectrum, the transit-time statistics as a function of signal level, and the dark-count spectrum of gigahertz bandwidth photomultipliers. Measurements showed that the 0.53 microns pulse used as an optical test source had a 30 picoseconds and less than 70 ps pulse width. Calibration data showed the system resolution to be less than 20 ps for root mean square transit-time measurements. Test data for a static crossed-field photomultiplier showed 2-photoelectron resolution and less than 30-ps time jitter over the 1- to 100-photoelectron range.

Abshire, J. B.

Performance of photomultiplier tubes and sodium iodide scintillation detector systems

The performance of photomultiplier tubes (PMT's) and scintillation detector systems incorporating 50.8 by 1.27 cm NaI (T l) crystals was investigated to determine the characteristics of the photomultiplier tubes and optimize the detector geometry for the Burst and Transient Source Experiment on the Gamma Ray Observatory. Background information on performance characteristics of PMT's and NaI (T l) detectors is provided, procedures for measurement of relevant parameters are specified, and results of these measurements are presented.

Meegan, C. A.

Calibration of a photomultiplier array spectrometer

A systematic approach to the calibration of a photomultiplier array spectrometer is presented. Through this approach, incident light radiance derivation is made by recognizing and tracing gain characteristics for each photomultiplier tube.

Bailey, Steven A.

Performance comparison of high speed microchannel plate photomultiplier tubes

The transit time spread characteristics of high speed microchannel photomultipliers has improved since the upgrade of the NASA CDSLR network to MCP-PMT's in the mid-1980's. The improvement comes from the incorporation of 6 micron (pore size) microchannels and offers significant improvement to the satellite ranging precision. To examine the impact on ranging precision, two microchannel plate photomultiplier tubes (MCP-PMT) were evaluated for output pulse characteristics and temporal jitter. These were a Hamamatsu R 2566 U-7 MCP-PMT (6 micron) and an ITT 4129f MCP-PMT (12 micron).

Varghese, Thomas

A New Method for Reduction of Photomultiplier Signal-Induced Noise

For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.

Koble, Andrea

Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (~120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ~15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ~15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY