PHASE DETECTOR AND PHASE FEEDBACK FOR A SINGLE BUNCH IN A TWO BUNCH DAMPING RING FOR THE SLAC LINEAR COLLIDER.
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Measurement of the ionization yields for nuclear recoils is related to the energy calibration of dark matter and low-energy neutrino detectors. In this study, some results of the previous measurements of the ionization yields for nuclear recoils in liquid argon using the neutron scattering technique in the two-phase detector are discussed. The methods to increase light collection of scintillation (S{sub 1}) and ionization (S{sub 2}) signals in the two-phase detector using SiPM matrices and THGEM electrodes with increased optical transparency are proposed. These steps are necessary to implement the neutron double-scattering technique, which will provide measurement of the ionization yield of recoiling nuclei in the unexplored energy range.
Progress in microelectronic technology has allowed us to design and develop a simple but, professional quality instrument for ultrasonic pulse-echo probing of the elastic properties of materials. The heart of this interfer- ometer lies in the AD8302 microchip, a gain and phase detector from Analog Devices, Inc. The interferometer was tested by measuring the temperature dependences of the ultrasound speed and attenuation in a ferro- electric KTa 0.92 Nb 0.08 O 3 (KTN) crystal at a frequency of about 40 MHz. These tests demonstrated that our instrument is capable of detecting the relative changes in the sound speed v on the level of Δv/v ~ 10 –7 . In addition, the ultrasound attenuation revealed new features in the development of the low-temperature structure of the ferroelectric KTN crystal.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Not Available
Explore the source record for details and available documents.
When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.
A two channel oblique electron cyclotron emission (ECE) radiometer was installed on the DIII-D tokamak and interfaced to four gyrotrons. Oblique ECE was used to toroidally and radially localize rotating magnetic islands and so assist their electron cyclotron current drive (ECCD) stabilization. In particular, after manipulations operated by the interfacing analogue circuit, the oblique ECE signals directly modulated the current drive in synch with the island rotation and in phase with the island O-point, for a more efficient stabilization. Apart from the different toroidal location, the diagnostic view is identical to the ECCD launch direction, which greatly simplified the real-time use of the signals. In fact, a simple toroidal extrapolation was sufficient to lock the modulation to the O-point phase. This was accomplished by a specially designed phase shifter of nearly flat response over the 1-7 kHz range. Moreover, correlation analysis of two channels slightly above and below the ECCD frequency allowed checking the radial alignment to the island, based on the fact that for satisfactory alignment the two signals are out of phase.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Dual phase xenon detectors are widely used in experimental searches for galactic dark matter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. Here, in this paper, we describe single electron backgrounds in 83m Kr calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
Purpose: To develop a dual-detector phase-matched DTS technique for continuous and fast intra-treatment lung tumor localization. Methods: Tumor localization accuracy of limited-angle DTS imaging is affected by low inter-slice resolution. The dual-detector DTS technique aims to overcome this limitation through combining orthogonally acquired beam’s eye view MV projections and kV projections for intra-treatment DTS reconstruction and localization. To aggregate the kV and MV projections for reconstruction, the MV projections were linearly converted to synthesize corresponding kV projections. To further address the lung motion induced localization errors, this technique uses respiratory phase-matching to match the motion information between on-board DTS and reference DTS to offset the adverse effects of motion blurriness in tumor localization.A study was performed using the CIRS008A lung phantom to simulate different on-board target variation scenarios for localization. The intra-treatment kV and MV acquisition was achieved through the Varian TrueBeam Developer Mode. Four methods were compared for their localization accuracy: 1. the proposed dual-detector phase-matched DTS technique; 2. the single-detector phase-matched DTS technique; 3. the dual-detector 3D-DTS technique without phase-matching; and 4. the single-detector 3D-DTS technique without phase-matching. Results: For scan angles of 2.5°, 5°, 10°, 20° and 30°, the dual-detector phase-matched DTS technique localized the tumor with average(±standard deviations) errors of 0.4±0.3 mm, 0.5±0.3 mm, 0.6±0.2 mm, 0.9±0.4 mm and 1.0±0.3 mm, respectively. The corresponding values of single-detector phase-matched DTS technique were 4.0±2.5 mm, 2.7±1.1 mm, 1.7±1.2 mm, 2.2±0.9 mm and 1.5±0.8 mm, respectively. The values of dual-detector 3D-DTS technique were 6.2±1.7 mm, 6.3±1.2 mm, 5.3±1.3 mm, 2.0±2.2 mm and 1.5±0.5 mm, respectively. And the values of single-detector 3D-DTS technique were 9.7±8.9 mm, 9.8±8.8 mm, 10.0±9.7 mm, 3.9±2.7 mm and 2.2±1.3 mm, respectively. Conclusion: The dual-detector phase-matched DTS technique substantially improves the tumor localization accuracy, which can be applied to real-time intra-treatment lung tumor localization. The research was funded by the National Institutes of Health Grant No. R01-CA184173 and a grant from Varian Medical Systems.
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. Central to achieving DUNE's physics program is a far detector that combines the many tens-of-kiloton fiducial mass necessary for rare event searches with sub-centimeter spatial resolution in its ability to image those events, allowing identification of the physics signatures among the numerous backgrounds. In the single-phase liquid argon time-projection chamber (LArTPC) technology, ionization charges drift horizontally in the liquid argon under the influence of an electric field towards a vertical anode, where they are read out with fine granularity. A photon detection system supplements the TPC, directly enhancing physics capabilities for all three DUNE physics drivers and opening up prospects for further physics explorations. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume IV presents an overview of the basic operating principles of a single-phase LArTPC, followed by a description of the DUNE implementation. Each of the subsystems is described in detail, connecting the high-level design requirements and decisions to the overriding physics goals of DUNE.
The international collaboration designing and constructing the Deep Underground Neutrino Experiment (DUNE) at the Long-Baseline Neutrino Facility (LBNF) has developed a two-phase strategy for the implementation of this leading-edge, large-scale science project. The 2023 report of the US Particle Physics Project Prioritization Panel (P5) reaffirmed this vision and strongly endorsed DUNE Phase I and Phase II, as did the previous European Strategy for Particle Physics. The construction of DUNE Phase I is well underway. DUNE Phase II consists of a third and fourth far detector module, an upgraded near detector complex, and an enhanced > 2 MW beam. The fourth FD module is conceived as a 'Module of Opportunity', aimed at supporting the core DUNE science program while also expanding the physics opportunities with more advanced technologies. The DUNE collaboration is submitting four main contributions to the 2026 Update of the European Strategy for Particle Physics process. This submission to the 'Detector instrumentation' stream focuses on technologies and R&D for the DUNE Phase II detectors. Additional inputs related to the DUNE science program, DUNE software and computing, and European contributions to Fermilab accelerator upgrades and facilities for the DUNE experiment, are also being submitted to other streams.