Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PDV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PDV Inspection and Analysis Demonstration: 2024 PDV Workshop

This document walks a user through a demonstration of working with PDV digitizer data using python. This demonstration and included suggested exercises will be used at the 2024 PDV workshop hands-on session as an example and skill-development training session. The tutorial allows the user to generate synthetic but realistic PDV waveform data and visualize/inspect the results using spectrograms and waveform viewing tools.

97 MATHEMATICS AND COMPUTING↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Enhanced PDV waveform search and analysis method using parallel circular-convolution / cross-correlation for improved dynamic surface velocity extraction [Poster]

Previous work on exhaustive search methodologies for extracting best-match parameters pertaining to dynamic surface quantities from PDV was done by cross-correlating synthetically generated PDV waveforms with observed counterparts using the circular-convolution theorem. This work was further developed into an open-source PDV analysis toolkit called CCPDVANALYSIS which expands upon and enhances the previously tested methods by parallelizing serial algorithmic components and incorporating a comprehensive script library for different flavors of instantaneous frequency functions utilized in generating synthetic PDV waveforms. Results of these enhancements have been shown to markedly decrease execution times of exhaustive search and extraction algorithms and produce improved velocity recoveries for low-velocity and dynamically varying velocity signals. The CCPDVANALYSIS script library demonstrates an advanced method for extracting velocities from low-velocity and non-constant velocity signals further extending and improving the methods beyond capabilities of traditional frequency domain tools.

97 MATHEMATICS AND COMPUTING↗

Technology and times scales in Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based measurement amenable to a wide range of experimental conditions. Interference between two optical signals—one Doppler shifted and the other not—is the essential principle in these measurements. A confluence of commercial technologies, largely driven by the telecommunication industry, makes PDV particularly convenient at near-infrared wavelengths. This discussion considers how measurement time scales of interest relate to the design, operation, and analysis of a PDV measurement, starting from the steady state through nanosecond resolution. Benefits and outstanding challenges of PDV are summarized, with comparisons to related diagnostics.

47 OTHER INSTRUMENTATION↗

Considerations for a PDV diagnostic capability on the National Ignition Facility

Photonic Doppler Velocimetry (PDV) has become widely and routinely used in many high-velocity experimental applications due to its improved ease of use, cost, experimental flexibility, data return, and robustness compared to earlier velocimetric methods. However, these earlier methods have advantages in applications with requirements beyond PDV’s current capabilities. Various classes of experiments at the National Ignition Facility (NIF) that are characterized by extremely high velocity or acceleration, or diagnostic requirements for high precision in timing and/or velocity, have historically seen a VISAR (velocity interferometer system for any surface) diagnostic employed due to such advantages. VISAR, however, requires specific, and sometimes challenging, experimental features, including planar geometry and normal incidence, high-reflectivity surface treatment, and a relatively large and inflexible diagnostic footprint. Therefore, the potential for implementing a PDV diagnostic at NIF has been evaluated by researchers from National Security Technologies, LLC and Lawrence Livermore National Laboratory. We present the results of this study, weigh the relative merits of the two methodologies with consideration of experimental phenomena and requirements, and discuss possible implementations and future directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme measurements with Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based diagnostic for the extreme conditions created by high-speed impact, explosive detonation, electrical pulsed power, and intense laser ablation. PDV is a conceptually simple application of the optical Doppler effect, but measurements above 1 km/s only became practical at the beginning of the twenty-first century. In this work, I discuss the evolution of PDV, its operational details, practical analysis, and outstanding challenges.

47 OTHER INSTRUMENTATION↗

Analyzing data from a PDV microphone

Photon Doppler Velocimetry (PDV) is used at Los Alamos National Laboratory to measure extremely fast velocities (on the order of 0.01 - 5 km/s) of projectiles during material testing procedures. This kind of testing is extremely important to understand how materials behave in extreme conditions (such as in nuclear explosions). PDV data is created by summing an incident beam with a Doppler shifted reflection, forming a beat frequency. The beat frequency is directly proportional to the velocity of the reflecting surface. We explored a new way of using PDV: measuring slow velocities (less than 1 m/s). The principle method we used was to measure vibrations in a Mylar sheet due to incident sound waves. I analyzed these files using both my own coding as well as a program designed at NSTec for this purpose. Analysis included performing Fourier Transforms, extracting velocity as a function of time, and playing the velocity function through a speaker to recreate the initial sound. We were able to create a successful microphone, though playback quality was poor. The limiting factor was the low velocity of the Mylar sheet, which was about 0.2 m/s. Other methods are now being explored to extract velocity data in a more efficient manner. During this project I gained extensive experience in programming, data analysis, problem solving, and communication. I learned that one must be creative in order to solve complex problems, approaching them from various angles. I also gained a lot of practice working on a team, which consisted of a high school student, another college intern, and our mentor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision and Accuracy in PDV and VISAR

This is a technical report discussing our current level of understanding of a wide and varying distribution of uncertainties in velocity results from Photonic Doppler Velocimetry in its application to gas gun experiments. Using propagation of errors methods with statistical averaging of photon number fluctuation in the detected photocurrent and subsequent addition of electronic recording noise, we learn that the velocity uncertainty in VISAR can be written in closed form. For PDV, the non-linear frequency transform and peak fitting methods employed make propagation of errors estimates notoriously more difficult to write down in closed form expect in the limit of constant velocity and low time resolution (large analysis-window width). An alternative method of error propagation in PDV is to use Monte Carlo methods with a simulation of the time domain signal based on results from the spectral domain. A key problem for Monte Carlo estimation for an experiment is a correct estimate of that portion of the time-domain noise associated with the peak-fitting region-of-interesting in the spectral domain. Using short-time Fourier transformation spectral analysis and working with the phase dependent real and imaginary parts allows removal of amplitude-noise cross terms that invariably show up when working with correlation-based methods or FFT power spectra. Estimation of the noise associated with a given spectral region of interest is then possible. At this level of progress, we learn that Monte Carlo trials with random recording noise and initial (uncontrolled) phase yields velocity uncertainties that are not as large as those observed. In a search for additional noise sources, a speckleinterference modulation contribution with off axis rays was investigated, and was found to add a velocity variation beyond that from the recording noise (due to random interference between off axis rays), but in our experiments the speckle modulation precision was not as important as the recording noise precision. But from these investigations we do appreciate that the velocity-uncertainty itself has a wide distribution of values that varies with signal-amplitude modulation (is not a single value). To provide a rough rule of thumb for the velocity uncertainty, we computed the average of the relative standard deviation distributions from 60 recorded traces (with distributions of uncertainties roughly between 0.1 % to 1 % in each trace) and found a mean of the distribution of uncertainties for our experiments is not better than 0.4 % at an analysis window width of 5 ns (although for brief intervals it can be as good as 0.1 %). Further imagination and testing may be needed to reveal other possible hydrodynamics-related sources of velocity error in PDV.

47 OTHER INSTRUMENTATION↗

Stastically determined experimental uncertainties in photon Doppler velocimetry (PDV) measurements

Shock-ramp experiments place high demands on the precision, accuracy, and temporal resolution of transformed velocimetry signals. To minimize uncertainty after total propagation of a shockramp experiment, ideally multiple PDV traces are used. However, each trace has some uncertainty that is a function of the PDV system and analysis of the velocimetry data. In order to determine a reasonable experimental estimate of minimum uncertainty, we calculate observed uncertainties in as-fielded PDV systems using multiple channels to sample the velocity on each shot. We also calculate the uncertainty’s sensitivity to choice of analysis methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small Windowed PDV Slab Shot Verification

Windowed PDV probes are used as a time of arrival diagnostic where conventional PDV measurements cannot be made with accuracy i.e., measurements where the surface measured is bare HE or the surface measured does not provide quality optical return for PDV directly. Often hydro experiments require that these diagnostics be minimally invasive, so their installation does not negatively impact the device performance or the overall experiments goals. In this report we build 3 mm diameter windowed probes and show that they give an error that is still within the error of piezo pins.

13 HYDRO ENERGY↗

What is the limiting performance of PDV (really)?

The limiting performance of PDV is determined by power spectrum location resolution - The uncertainty principle overestimates error and peak fit confidences underestimates error. Simulations indicate that PDV is: (1) Inaccurate and imprecise at low frequencies; (2) Accurate and (potentially) precise otherwise; (3) Limiting performance can be tied to sampling rate, noise fraction, and analysis duration. Frequency conversion is a good thing. PDV is competitive with VISAR, despite wavelength difference.

99 GENERAL AND MISCELLANEOUS↗

Large-Area PDV for Characterizing Explosive Particle and Fragment Velocity Distributions, STL-023-17, Year 1 of 1

This presentation describes a project to develop a PDV system that can measure over an area of 80 cm2, as opposed to the traditional point-sampling PDV. Ultimately the large-area PDV could be used to characterize the morphological evolution of a high-explosive event over the complete event, from very early stages (source terms) to an equilibrium state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting Short Rise-Time Velocity Profiles with Digital Down-Shift Analysis of Optically Up-Converted PDV Data

This work describes the digital down-shift (DDS) technique, a new method of extracting short rise-time velocity profiles in the analysis of optically up-converted PDV data. The DDS technique manipulates the PDV data by subtracting a constant velocity (i.e., the DDS velocity νDDS) from the velocity profile. DDS exploits the simple fact that the optically up-converted data ride on top of a base velocity (ν0, the apparent velocity at no motion) with a rapid rise to a high velocity (νf) of a few km/s or more. Consequently, the frequency content of the signal must describe a velocity profile that increases from ν0 to ν0 + νf. The DDS technique produces velocity reversals in the processed data before shock breakout when ν0 < νDDS < ν0 + νf. The DDS analysis process strategically selects specific DDS velocities (velocity at which the user down shifts the data) that produce anomalous reversals (maxima and/or minima), which are predictable and easy to identify in the mid-range of the data. Additional analysis determines when these maxima and minima occur. By successive application of the DDS technique and iterative analysis, velocity profiles are extracted as time as a function of velocity rather than as a function of time as it would be in a conventional velocity profile. Presented results include a description of DDS, velocity profiles extracted from laser-driven shock data with rise times of 200 ps or less, and a comparison with other techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LLNL Final Design for PDV Measurements of Godiva for Validation of Multi-Physics Simulation

This document is a Final Design (CED-2) Report for IER-268, “PDV Measurements of Godiva for Validation of Multi-Physics Simulation”. These measurements will measure surface velocities in several locations, the initial α and α-t curve as a function of fission yield using existing LLNL assets including: The portable Photonic Doppler Velocimeter (PDV) detector; The “alpha box”, and; Aluminum-encapsulated 235 U fission foils. These experiments will be simulated using multi-physics methods funded separately under LLNL-AM2. A supercritical benchmark specification will be developed; and, if funding permits, an ICSBEP (or classified equivalent) evaluation will be published.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Limiting noise fraction in PDV measurements

The limiting frequency resolution of a PDV measurement is: σf = $\sqrt\frac{6 η}{fsτ^3π}$ where f s is the sample rate, τ is the analysis time duration, and 11 is the noise fraction. Although T is a strong lever for reducing uncertainty, this parameter must be kept small to preserve time resolution. Consider a PDV measurement with sampled at 80 GS/s and analyzed in 1 ns durations. A 1% noise fraction corresponds to 0.87 MHz of frequency uncertainty, which at 1550 nm works out to 0.68 m/s. A 10% noise fraction has a limiting velocity resolution of about 7 m/s; for comparison, a VISAR system with similar response time (0.5 ns delay, 532 m/s fringe constant) would have a limiting uncertainty of 5-6 m/s. Noise fractions of 10-20% or less are desirable for measurements at this time scale.

42 ENGINEERING↗

Brief History and Summary of the PDV [Slides]

The early development of the PDV was not a straightforward process. There were many fortuitous events that occurred over several years to make it happen. The drive toward more PDV channels per digitizer was initially driven by the high cost of the digitizer. The optical pin dome diagnostic for the national labs was the driver for very large channel count.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PDV modifications.

External modifications can transform a conventional photonic doppler velocimetry (PDV) system to other useful configurations - Non-standard probes and Frequency-conversion measurements. This approach is easier than supporting every conceivable measurement in the core PDV design. Circulator specifications may be important - -30 dB isolation (common) probably not be enough, -50 dB isolation is available, and some bench testing may be needed.

99 GENERAL AND MISCELLANEOUS↗