Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PCR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PCR Based Microbial Monitor for Analysis of Recycled Water Aboard the ISSA: Issues and Prospects

The monitoring of spacecraft life support systems for the presence of health threatening microorganisms is paramount for crew well being and successful completion of missions. Development of technology to monitor spacecraft recycled water based on detection and identification of the genetic material of contaminating microorganisms and viruses would be a substantial improvement over current NASA plans to monitor recycled water samples that call for the use of conventional microbiology techniques which are slow, insensitive, and labor intensive. The union of the molecular biology techniques of DNA probe hybridization and polymerase chain reaction (PCR) offers a powerful method for the detection, identification, and quantification of microorganisms and viruses. This technology is theoretically capable of assaying samples in as little as two hours with specificity and sensitivity unmatched by any other method. A major advance in probe-hybridization/PCR has come about in a technology called TaqMan(TM), which was invented by Perkin Elmer. Instrumentation using TaqMan concepts is evolving towards devices that could meet NASA's needs of size, low power use, and simplicity of operation. The chemistry and molecular biology needed to utilize these probe-hybridization/PCR instruments must evolve in parallel with the hardware. The following issues of chemistry and biology must be addressed in developing a monitor: Early in the development of a PCR-based microbial monitor it will be necessary to decide how many and which organisms does the system need the capacity to detect. We propose a set of 17 different tests that would detect groups of bacteria and fungus, as well as specific eukaryotic parasites and viruses; In order to use the great sensitivity of PCR it will be necessary to concentrate water samples using filtration. If a lower limit of detection of 1 microorganism per 100 ml is required then the microbes in a 100 ml sample must be concentrated into a volume that can be added to a PCR assay; There are not likely to be contaminants in ISSA recycled water that would inhibit PCR resulting in false-negative results; The TaqMan PCR product detection system is the most promising method for developing a rapid, highly automated gene-based microbial monitoring system. The method is inherently quantitative. NASA and other government agencies have invested in other technologies that, although potentially could lead to revolutionary advances, are not likely to mature in the next 5 years into working systems; PCR-based methods cannot distinguish between DNA or RNA of a viable microorganism and that of a non-viable organism. This may or may not be an important issue with reclaimed water on the ISSA. The recycling system probably damages the capacity of the genetic material of any bacteria or viruses killed during processing to serve as a template in a PCR desinged to amplify a large segment of DNA (less than 650 base pairs). If necessary, vital dye staining could be used in addition to PCR, to enumerate the viable cells in a water sample; The quality control methods have been developed to insure that PCR's are working properly, and that reactions are not contaminated with PCR carryover products which could lead to the generation of false-positive results; and The sequences of the small rRNA subunit gene for a large number of microorganisms are known, and they consititue the best database for rational development of the oligonucleotide reagents that give PCR its great specificity. From those gene sequences, sets of oligonucleotide primers for PCR and Taqman detection that could be used in a NASA microbial monitor were constructed using computer based methods. In addition to space utilization, a microbial monitior will have tremendous terrestrial applications. Analysis of patient samples for microbial pathogens, testing industrial effluent for biofouling bacteria, and detection biological warfare agents on the battlefield are but a few of the diverse potential uses for this technology. Once fully developed, gene-based microbial monitors will become the fundamental tool in every lab that tests for microbial contaminants, and serve as a powerful weapon in mankind's war with the germ world.

Cassell, Gail H.

Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station

The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

gene expression

Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station

The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

quantitative PCR

A PCR Based Microbial Monitoring Alternative Method of Detection and Identification of Microbes Aboard ISS

Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS) with additional introduction of new microflora occurring with every exchange of crew or addition of equipment and supplies. These microbes are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). As this can be detrimental to astronaut health and optimal performance of ISS systems, monitoring of systems such as ECLSS to include identification of microbial contaminants could prevent adverse effects on human health and life support systems. Current monitoring on ISS is laborious and utilizes culture based methods followed by sample return to Earth for complete analysis. Future, long-distance spaceflight missions will require real-time monitoring capabilities that enable efficient and rapid assessments of the microbial environment allowing for expedited decisions and more targeted response to cope with anomalies. Polymerase chain reaction (PCR), a molecular microbial monitoring method was chosen and numerous PCR instruments investigated for their potential to perform in microgravity conditions. Using ISS as a test bed for PCR verification in microgravity will enable NASA to assess whether molecular based microbiological sensors may be components of reliable, closed-loop life support and habitation systems in spacecraft, enhancing infrastructure capabilities through increased efficiency, reliability, and time savings by enabling sample analysis on orbit. NASA selected the Water Monitoring Suite as one of the rapid spaceflight hardware demonstration activities utilizing a streamlined process to minimize the time required to fly experimental flight hardware. The RAZOR EX (BioFire Defense, Salt Lake City, UT) system was part of the water monitoring suite and is a commercial off-the-shelf (COTS) real-time PCR instrument designed for field work. The RAZOR EX was originally designed for Department of Defense (DoD) under a small business innovative research (SBIR) grant and is ruggedized, compact and provides a rapid, sample to answer in less than an hour. PCR assays using a fluorescent probe were optimized and spiked with known concentrations of DNA (Pseudomonas aeruginosa) ranging from 0.002 to 20 ng. PCR reagents were lyophilized and configured in customized pouches and tested for flight readiness. Three types of water were used to rehydrate the reagents and demonstrate the fidelity of the PCR reaction in microgravity. Molecular grade deionized water served as a control while filtered and unfiltered ISS potable water served to test for chemical or biological inhibitors. All three types were compared to parallel ground test results. Nine tests were run on ISS (3 of each water type) and the critical threshold cycle (Ct) was compared to parallel ground tests completed at Kennedy Space Center, FL and Johnson Space Center, TX. All concentrations of Pseudomonas aeruginosa DNA were detected. A comparison of the Ct produced in real time PCR indicated similarity between flight and ground samples. There appeared to be no significant difference between flight or ground PCR reactions or between any of the three water types. This testing demonstrated the ability to perform molecular testing during spaceflight operations with similar sensitivity. It will allow for future ground development of molecular protocols and minimize the need for spaceflight testing. Future testing will include development of additional targets including environmental and health related organisms.

Christina Khodadad

WetLab-2: Providing Quantitative PCR Capabilities on ISS

The objective of NASA Ames Research Centers WetLab-2 Project is to place on the ISS a system capable of conducting gene expression analysis via quantitative real-time PCR (qRT-PCR) of biological specimens sampled or cultured on orbit. The WetLab-2 system is capable of processing sample types ranging from microbial cultures to animal tissues dissected on-orbit. The project has developed a RNA preparation module that can lyse cells and extract RNA of sufficient quality and quantity for use as templates in qRT-PCR reactions. Our protocol has the advantage that it uses non-toxic chemicals, alcohols or other organics. The resulting RNA is transferred into a pipette and then dispensed into reaction tubes that contain all lyophilized reagents needed to perform qRT-PCR reactions. These reaction tubes are mounted on rotors to centrifuge the liquid to the reaction window of the tube using a cordless drill. System operations require simple and limited crew actions including syringe pushes, valve turns and pipette dispenses. The resulting process takes less than 30 min to have tubes ready for loading into the qRT-PCR unit.The project has selected a Commercial-Off-The-Shelf (COTS) qRT-PCR unit, the Cepheid SmartCycler, that will fly in its COTS configuration. The SmartCycler has a number of advantages including modular design (16 independent PCR modules), low power consumption, rapid thermal ramp times and four-color detection. The ability to detect up to four fluorescent channels will enable multiplex assays that can be used to normalize for RNA concentration and integrity, and to study multiple genes of interest in each module. The WetLab-2 system will have the capability to downlink data from the ISS to the ground after a completed run and to uplink new programs. The ability to conduct qRT-PCR on-orbit eliminates the confounding effects on gene expression of reentry stresses and shock acting on live cells and organisms or the concern of RNA degradation of fixed samples. The system can be used to validate terrestrial analyses of samples returned from ISS by providing on-orbit gene expression benchmarking prior to sample return. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time for subsequent trials, without the need for sample return and re-flight to sample multigenerational changes. The system can also be used for analysis of air, surface, water, and clinical samples to monitor environmental contaminants and crew health. The verification flight of the instrument is scheduled to launch on SpaceX-7 in June 2015. The WetLab-2 Project is supported by NASAs ISS Program at JSC, Code OZ.

ISS tools

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]

Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity

Current planetary protection policies require that spacecraft targeted to sensitive solar system bodies be assembled and readied for launch in controlled cleanroom environments. A better understanding of the distribution and frequency at which high-risk contaminant microbes are encountered on spacecraft surfaces would significantly aid in assessing the threat of forward contamination. However, despite a growing understanding of the diverse microbial populations present in cleanrooms, less abundant microbial populations are probably not adequately taken into account due to technological limitations. This novel approach encompasses a wide spectrum of microbial species and will represent the true picture of spacecraft cleanroom-associated microbial diversity. All of the current microbial diversity assessment techniques are based on an initial PCR amplification step. However, a number of factors are known to bias PCR amplification and jeopardize the true representation of bacterial diversity. PCR amplification of a minor template appears to be suppressed by the amplification of a more abundant template. It is widely acknowledged among environmental molecular microbiologists that genetic biosignatures identified from an environment only represent the most dominant populations. The technological bottleneck overlooks the presence of the less abundant minority population and may underestimate their role in the ecosystem maintenance. DNA intercalating agents such as propidium monoazide (PMA) covalently bind with DNA molecules upon photolysis using visible light, and make it unavailable for DNA polymerase enzyme during polymerase chain reaction (PCR). Environmental DNA samples will be treated with suboptimum PMA concentration, enough to intercalate with 90 99% of the total DNA. The probability of PMA binding with DNA from abundant bacterial species will be much higher than binding with DNA from less abundant species. This will increase the relative DNA concentration of previously "shadowed" less abundant species available for PCR amplification. These PCR products obtained with and without PMA treatment will then be subjected to downstream diversity analyses such as sequencing and DNA microarray. It is expected that PMA-coupled PCR will amplify the "minority population" and help in understanding microbial diversity spectrum of an environmental sample at a much deeper level. This new protocol aims to overcome the major potential biases faced when analyzing microbial 16S rRNA gene diversity. This study will lead to a technological advancement and a commercial product that will aid microbial ecologists in understanding microbial diversity from various environmental niches. Implementation of this technique may lead to discoveries of novel microbes and their functions in sustenance of the ecosystem.

Vaishampayan, Parag A.

On-orbit RNA Purification and qRT-PCR Capabilities of the WetLab-2 System

NASA Ames Research Center’s WetLab-2 system brings new capabilities to the ISS for researchers. The system can lyse cells and extract RNA on-orbit from different sample types ranging from microbial cultures to animal tissues. Our purification method has the advantage of using non-toxic chemicals and does not require alcohols or other organics. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (qRT-PCR) analysis without the need for sample return. qRT-PCR reactions are performed by dispensing the RNA into reaction tubes that contain all lyophilized reagents needed to perform the analysis. The system uses a Cepheid® SmartCycler that allows for multiplexing of assays, this can be used to normalize for RNA concentration and integrity and to study multiple genes of interest in each tube. There are a total of 16 independent PCR modules each capable of detecting up to four fluorescent channels. The WetLab- 2 system can downlink data from the ISS to the ground after a completed run and uplink new thermal cycling programs. The ability to purify and stabilize RNA on-orbit can eliminate the confounding effects of reentry stresses and shock acting on live cells and organisms or the concern of RNA degradation of some samples. It also has the benefit of minimizing the needed downmass. Conducting qRT-PCR and generating results on-orbit is also an important step towards utilizing the ISS as a National Laboratory facility. Specifically, the ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. On orbit gene expression analysis can also provide benchmarking prior to sample return. The system can also be used for analysis of air, surface, water, and clinical samples to monitor environmental pathogens and crew health. The validation flight of the WetLab-2 system using E. coli bacteria and mouse liver is scheduled to launch on SpaceX-8 this spring. Pending operations, the preliminary results from the validation flight will be presented. To support the needs of future researchers, we are adapting our system to purify RNA from two additional sample types: fibrous tissue such as muscle and mammalian adherent cells grown on alginate beads. Progress of this work will also be presented. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

Parra, Macarena

Efficient mutagenesis and genotyping of maize inbreds using biolistics, multiplex CRISPR/Cas9 editing, and Indel-Selective PCR

CRISPR/Cas9 based genome editing has advanced our understanding of a myriad of important biological phenomena. Important challenges to multiplex genome editing in maize include assembly of large complex DNA constructs, few genotypes with efficient transformation systems, and costly/labor-intensive genotyping methods. Here we present an approach for multiplex CRISPR/Cas9 genome editing system that delivers a single compact DNA construct via biolistics to Type I embryogenic calli, followed by a novel efficient genotyping assay to identify desirable editing outcomes. We first demonstrate the creation of heritable mutations at multiple target sites within the same gene. Next, we successfully created individual and stacked mutations for multiple members of a gene family. Genome sequencing found off-target mutations are rare. Multiplex genome editing was achieved for both the highly transformable inbred line H99 and Illinois Low Protein1 (ILP1), a genotype where transformation has not previously been reported. In addition to screening transformation events for deletion alleles by PCR, we also designed PCR assays that selectively amplify deletion or insertion of a single nucleotide, the most common outcome from DNA repair of CRISPR/Cas9 breaks by non-homologous end-joining. The Indel-Selective PCR (IS-PCR) method enabled rapid tracking of multiple edited alleles in progeny populations. The ‘end to end’ pipeline presented here for multiplexed CRISPR/Cas9 mutagenesis can be applied to accelerate maize functional genomics in a broader diversity of genetic backgrounds.

59 BASIC BIOLOGICAL SCIENCES

Data for "Efficient Mutagenesis and Genotyping of Maize Inbreds Using Biolistics, Multiplex CRISPR/Cas9 Editing, and Indel-Selective PCR"

CRISPR/Cas9 based genome editing has advanced our understanding of a myriad of important biological phenomena. Important challenges to multiplex genome editing in maize include assembly of large complex DNA constructs, few genotypes with efficient transformation systems, and costly/labor-intensive genotyping methods. Here we present an approach for multiplex CRISPR/Cas9 genome editing system that delivers a single compact DNA construct via biolistics to Type I embryogenic calli, followed by a novel efficient genotyping assay to identify desirable editing outcomes. We first demonstrate the creation of heritable mutations at multiple target sites within the same gene. Next, we successfully created individual and stacked mutations for multiple members of a gene family. Genome sequencing found off-target mutations are rare. Multiplex genome editing was achieved for both the highly transformable inbred line H99 and Illinois Low Protein1 (ILP1), a genotype where transformation has not previously been reported. In addition to screening transformation events for deletion alleles by PCR, we also designed PCR assays that selectively amplify deletion or insertion of a single nucleotide, the most common outcome from DNA repair of CRISPR/Cas9 breaks by non-homologous end-joining. The Indel-Selective PCR (IS-PCR) method enabled rapid tracking of multiple edited alleles in progeny populations. The ‘end to end’ pipeline presented here for multiplexed CRISPR/Cas9 mutagenesis can be applied to accelerate maize functional genomics in a broader diversity of genetic backgrounds.

gene editing

Optimization of PMA-PCR Protocol for Viability Detection of Pathogens

This presented study demonstrates the need that PMA-PCR can be used to capture the loss of viability of a sample that is much more specific and time-efficient than alternative methods. This protocol is particularly useful in scenarios in which sterilization treatments may inactivate organisms but not degrade their DNA. The use of a PCR-based method of pathogen detection without first inactivating the DNA of nonviable cells will potentially lead to false positives. The loss of culturability, by heat-killing, did not prevent amplified PCR products, which supports the use of PMA to prevent amplification and differentiate between viable and dead cells. PMA was shown to inhibit the amplification of DNA by PCR in vegetative cells that had been heat-killed.

propidium monoazide (PMA)

Novel Approach to Quantification of Telomere Length with Direct Nanopore Sequencing and PCR Amplification

The ends of human chromosomes contain telomeres, or tandem arrays of repeating DNA sequences capped by multiple associated proteins that protect chromosomal ends from degradation. Telomeres function to preserve genomic stability by preventing natural chromosomal ends from being recognized as broken DNA double-strand breaks and triggering inappropriate DNA damage responses. Mounting evidence shows telomere length is an inherited trait that decreases with cellular division and normal aging. In addition, telomere length also appears to be influenced by other factors such as cellular oxidative stress, radiation and mechanical unloading of tissues as in microgravity. To measure these potential effects of the space environment on telomere lengths and cellular aging and regenerative potential we developed a novel telomere measurement approach based on nanopore sequencing of PCR amplified bar-coded chromosome termini. Specifically, telomeres can be directly enriched using barcode sequences ligated to the end of a free end- repaired telomere using the WetLab-2 facility SmartCycler on ISS. Prior to the ligation and amplification protocol a proteinase K digestion of capping proteins followed by a single 95-degree C heat denaturation of the protease is included. After digestion and bar-code ligation, PCR amplification will initiate with the ligated barcoded sequence, suppressing amplification of intra-genomic fragments and resulting in long read barcoded telomere amplicons including the nanopore motor protein sequences. Purified PCR amplicons are then used for nanopore sequencing library generation by simple addition of motor proteins and sequencing library is loaded into the MinION nanopore DNA-sequencer. Amplicon sequence reads from the nanopore device can be base-called quickly on ISS due to barcoding ligation and subsequent PCR amplification enhancing the telomere sequence resolution. If successfully implemented on ISS this technique will provide a novel means of measuring regenerative ability of somatic stem cells in astronauts, and of determining whether spaceflight in microgravity alters their telomere lengths and causes premature cellular aging.

Ma, Kristin R.

Deep Diversity: Novel Approach to Overcoming the PCR Bias Encountered During Environmental Analysis of Microbial Populations for Alpha-Diversity

Alpha-diversity studies are of crucial importance to environmental microbiologists. The polymerase chain reaction (PCR) method has been paramount for studies interrogating microbial environmental samples for taxon richness. Phylogenetic studies using this technique are based on the amplification and comparison of the 16S rRNA coding regions. PCR, due disproportionate distribution of microbial species in the environment, increasingly favors the amplification of the most predominant phylotypes with every subsequent reaction cycle. The genetic and chemical complexity of environmental samples are intrinsic factors that exacerbate an inherit bias in PCR-based quantitative and qualitative studies of microbial communities. We report that treatment of a genetically complex total genomic environmental DNA extract with Propidium Monoazide (PMA), a DNA intercalating molecule capable of forming a covalent cross-linkage to organic moieties upon light exposure, disproportionally inactivates predominant phylotypes and results in the exponential amplification of previously shadowed microbial ?-diversity quantified as a 19.5% increase in OUTs reported via phylogenetic screening using PhyloChip.

phylogenetic microarray technologies

Nanopore Activity Assays for Detection of Biomarker Protease Activity: Design and Testing of Substrates for Both Nanopore Sequencing and PCR-Based Detection Methods

The work performed in this project has demonstrated the ability to construct proteolytic enzyme substrates that are PCR and sequencing-readable reporter molecules. Specifically, the goal was to detect those reporter molecules via PCR and Oxford Nanopore Technologies MinION sequencing methods following exposure to the biomarker protease thrombin. The assay development focused on binding the constructed peptide-oligonucleotide chimera to immobilized streptavidin. The action of thrombin on the peptide portion of the molecule released the oligonucleotide for detection. Detection of protease activity was demonstrated in a concentration-dependent manner using MALDI-MS, RT-PCR and DNA sequencing. Additional steps to remove background release of reporter molecules during the assay was used to improve the difference in detected oligonucleotide reporter following protease activity. Additional steps in assay development will be to (1) test the assay in an appropriate matrix, (2) investigate detection using additional DNA sequencing platforms and (3) demonstrate multiplexed detection of multiple protease markers in a single reaction.

59 BASIC BIOLOGICAL SCIENCES

Multiplex titration RT-PCR: rapid determination of gene expression patterns for a large number of genes

We have developed an improved method for determination of gene expression levels with RT-PCR. The procedure is rapid and does not require extensive optimization or densitometric analysis. Since the detection of individual transcripts is PCR-based, small amounts of tissue samples are sufficient for the analysis of expression patterns in large gene families. Using this method, we were able to rapidly screen nine members of the Aux/IAA family of auxin-responsive genes and identify those genes which vary in message abundance in a tissue- and light-specific manner. While not offering the accuracy of conventional semi-quantitative or competitive RT-PCR, our method allows quick screening of large numbers of genes in a wide range of RNA samples with just a thermal cycler and standard gel analysis equipment.

Non-NASA Center

Analysis of myosin heavy chain mRNA expression by RT-PCR

An assay was developed for rapid and sensitive analysis of myosin heavy chain (MHC) mRNA expression in rodent skeletal muscle. Only 2 microg of total RNA were necessary for the simultaneous analysis of relative mRNA expression of six different MHC genes. We designed synthetic DNA fragments as internal standards, which contained the relevant primer sequences for the adult MHC mRNAs type I, IIa, IIx, IIb as well as the embryonic and neonatal MHC mRNAs. A known amount of the synthetic fragment was added to each polymerase chain reaction (PCR) and yielded a product of different size than the amplified MHC mRNA fragment. The ratio of amplified MHC fragment to synthetic fragment allowed us to calculate percentages of the gene expression of the different MHC genes in a given muscle sample. Comparison with the traditional Northern blot analysis demonstrated that our reverse transcriptase-PCR-based assay was reliable, fast, and quantitative over a wide range of relative MHC mRNA expression in a spectrum of adult and neonatal rat skeletal muscles. Furthermore, the high sensitivity of the assay made it very useful when only small quantities of tissue were available. Statistical analysis of the signals for each MHC isoform across the analyzed samples showed a highly significant correlation between the PCR and the Northern signals as Pearson correlation coefficients ranged between 0.77 and 0.96 (P < 0.005). This assay has potential use in analyzing small muscle samples such as biopsies and samples from pre- and/or neonatal stages of development.

Non-NASA Center

Extraction of Pure Plastic Resins From PCR Plastic Waste by Solvent-Targeted Recovery and Precipitation (STRAP)

For this work, we have been developing a solvent‐based plastic recycling technology called STRAP. The technology is based on dissolving a targeted plastic resin in a specific solvent that does not dissolve other resins. We have demonstrated STRAP in thousands of bench scale experiments for a large variety of wastes. Recently we have demonstrated the technology for PCR, using mixed plastic wastes (MPWs), from a wet Material Recovery Facility (MRF). The process includes (1) infrared (IR) characterization to determine the plastic composition for accurate selection of the solvent to be used for the extraction of the pure resins. (2) Shredding to the right size and aspect ratio required for flowable and fast dissolvable process. (3) Mixing the MPW in the first solvent to dissolve the first resin. (4) Filtration of the solution plastic blend, to separate the nondissolved plastic from the solution. (5) Further filtration of the solution to remove micron‐sized particle of pigments and fibers. (6) Cooling for precipitation. (7) Filtration of pure resins. (8) Drying of a pure resin. (9) Extrusion of the resin to pellets. (10) Generating films or other products from the pure resin. Steps 1–10 can be considered as one‐cycle that extracted the first resin. (11) A second resin can be extracted with a respective solvent from the plastic that did not dissolve in the first cycle and following steps 1–10 described above. The process also includes characterization of interim and final products. The effort includes building a pilot system at 25 kg/h throughput. We will present specific results for various PCR.

IR characterization

Q-PCR based bioburden assessment of drinking water throughout treatment and delivery to the International Space Station

Previous studies indicated evidence of opportunistic pathogens samples obtained during missions to the International Space Station (ISS). This study utilized TaqMan quantitative PCR to determine specific gene abundance in potable and non-potable ISS waters. Probe and primer sets specific to the small subunit rRNA genes were used to elucidate overall bacterial rRNA gene numbers. while those specific for Burkholderia cepacia and Stenotrophomonas maltophilia were optimized and used to probe for the presence of these two opportunistic pathogens. This research builds upon previous microbial diversity studies of ISS water and demonstrates the utility of Q-PCR tool to examine water quality.

Q-PCR