Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PCM window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

A Comprehensive Comparison of Methods for Evaluating Dispatch of Long-Duration Energy Storage in Power Systems Models

Long-duration energy storage (LDES) could play a pivotal role in the transformation of electricity grids with high shares of variable renewable energy (VRE) such as solar and wind. However, the weather-dependent nature of VRE introduces challenges for grid balancing and stability, which LDES - along with short-duration energy storage (SDES) - can help address. However, modeling LDES in production cost models (PCMs) is particularly challenging due to the need for high temporal resolution over extended optimization windows while preserving chronology, which ensures the alignment of energy storage operations with VRE generation over multi-day periods. This report compares traditional dispatch methods with advanced LDES dispatch strategies, such as the extended horizon approach, across different PCM platforms and examines tradeoffs and scalability. The comparison reveals that the traditional 1-day optimization horizon within the PCM leads to inefficient utilization of LDES. In contrast, extending the optimization horizon as much as possible significantly reduces curtailment and improves storage dispatch, especially in renewable-dense systems. There is also promise in using state-of-charge or end volume targets set by an external model, however this requires an additional modeling set and generally increases computational burden. This paper presents a comparison of these various methods in a number of power systems, showing algorithms initially in small test systems and scaling up to large, country-wide simulations. Overall, the research presents the trade-offs of various computational methods and illustrates how LDES may play an essential role in power systems of the future.

14 SOLAR ENERGY↗

MUSiC: Critical Experiment with Bare Highly Enriched Uranium Shells Benchmark

The measurements of the Uranium Subcritical and Critical (MUSiC) experiment were performed from December 2020 through April 2021. The purpose of the experiment was to test a variety of multiplicity detection systems for a large range of multiplication values and to see how well they perform as the k eff of the MUSiC series of experiments approached the delayed critical window. Out of the ten configurations that were studied, two of them were super critical and were recently approved as benchmarks and they will be included in the International Criticality Safety Benchmark Evaluation Project (ICBESP) handbook. For each of the two experiments, uncertainties were evaluated six categories: (1) critical measurement, (2) mass, (3) composition, (4) positioning, (5) dimensions, and (6) temperature. The largest contribution to the overall uncertainty in each of the cases was due to the uncertainties in the dimensions of the HEU Rocky Flats shells. Simplified detailed models were created with an average bias of -130.5 pcm due to the removal various components surrounding the experiment. For MCNP6.2 models using ENDF-VIII.0 neutron cross section data, the average difference between the calculated and benchmark k effs was -54 pcm for the detailed model and -102 pcm for the simplified model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technology for Electrically Enhanced Thermochemical Hydrogen (TEETH)

This is the Final Technical Report for the TEETH project. The TEETH concept couples high-temperature solar-thermochemical water splitting (TCWS) with electrochemical H 2 pumping through a proton conducting membrane (PCM) and capitalizes on the benefits of the individual technologies to synergistically providing new benefits. That is, TEETH is a coupled thermochemical/electrochemical process to produce H 2 from steam using solar energy. This approach is thermodynamically equivalent to other hybrid electrolytic processes but is unique in that the equilibrium of the reaction is driven forward by close coupling an electrically driven proton-conducting-membrane to the H 2 -producing reoxidation step. The process uniquely provides and benefits from the necessary H 2 /steam separation and, also unlike other hybrid processes, benefits thermodynamically from the use of readily generated high pressure steam. The concept also satisfies the objectives of previous concepts: 1) decreasing the reduction enthalpy (the reduction temperature), of the working metal-oxide (MO); 2) eliminating the need for a windowed receiver; and 3) widening the scope of material candidates, while also obviating the need for electrical connections to the working MO and avoiding the use of aqueous electrolytes and hydrated redox species (there is no liquid phase), without increasing mechanical complexity.

08 HYDROGEN↗