Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Effect of Dietary Countermeasures and Impact of Gravity on Renal Calculi Size Distributions Predicted by PBE-System and PBE-CFD Models

Renal stone disease is not only a concern on earth but can conceivably pose a serious risk to the astronauts health and safety in Space. In this work, two different deterministic models based on a Population Balance Equation (PBE) analysis of renal stone formation are developed to assess the risks of critical renal stone incidence for astronauts during space travel. In the first model, the nephron is treated as a continuous mixed suspension mixed product removal crystallizer and the PBE for the nucleating, growing and agglomerating renal calculi is coupled to speciation calculations performed by JESS. Predictions of stone size distributions in the kidney using this model indicate that the astronaut in microgravity is at noticeably greater but still subcritical risk and recommend administration of citrate and augmented hydration as effective means of minimizing and containing this risk. In the second model, the PBE analysis is coupled to a Computational Fluid Dynamics (CFD) model for flow of urine and transport of Calcium and Oxalate in the nephron to predict the impact of gravity on the stone size distributions. Results presented for realistic 3D tubule and collecting duct geometries, clearly indicate that agglomeration is the primary mode of size enhancement in both 1g and microgravity. 3D numerical simulations seem to further indicate that there will be an increased number of smaller stones developed in microgravity that will likely pass through the nephron in the absence of wall adhesion. However, upon reentry to a 1g (Earth) or 38g (Mars) partial gravitational fields, the renal calculi can lag behind the urinary flow in tubules that are adversely oriented with respect to the gravitational field and grow agglomerate to large sizes that are sedimented near the wall with increased propensity for wall adhesion, plaque formation, and risk to the astronauts.

Renal Stones↗

Dryout and Rewetting in the Pool Boiling Experiment Flown on STS-72 (PBE-2 B) and STS-77 (PBE-2 A)

Experiments were conducted in the microgravity of space in which a pool of liquid (R-113), initially at a precisely defined pressure and temperature, is subjected to a step imposed heat flux from a semi-transparent thin-film heater forming part of one wall of the container such that boiling is initiated and maintained for a defined period of time at a constant pressure level. A total of nine tests were conducted at three levels of heat flux and three levels of subcooling in each of the two space experiments in a GAS canister on the STS-77, -72, respectively. Three (3) modes of propagation of boiling across the heater surface and subsequent vapor bubble growths were observed, in addition to the two (2) modes observed in the previous microgravity pool boiling space flights on STS-47, -57, and -60. Of particular interest were the extremely dynamic or "explosive" growths, which were determined to be the consequence of the large increase in the liquid-vapor interface area associated with the appearance of a corrugated or rough interface. Predictions of circumstances for its onset have been carried out. Assumptions were necessary regarding the character of disturbances necessary for the instabilities to grow. Also, a new vapor bubble phenomena was observed in which small vapor bubbles migrated toward a larger bubble, eventually coalescing with this larger bubble. The heat transfer was enhanced approximately 30% as a result of these migrating bubbles, which is believed to be a vapor bubble manifestation of Marangoni convection and/or molecular momentum effects, sometimes referred to as vapor recoil. The circumstances of heat flux and liquid subcooling necessary to produce heater surface dryout for an initially stagnant liquid subjected to an imposed heat flux have been more closely identified.

Merte, Herman, Jr.↗

Coupled CFD-PBE Predictions of Renal Stone Size Distributions in the Nephron in Microgravity

In this paper, a deterministic model is developed to assess the risk of critical renal stone formation for astronauts during space travel. A Population Balance Equation (PBE) model is used to compute the size distribution of a population of nucleating, growing and agglomerating renal calculi as they are transported through different sections of the nephron. The PBE model is coupled to a Computational Fluid Dynamics (CFD) model that solves for steady state flow of urine and transport of renal calculi along with the concentrations of ionic species, calcium and oxalate, in the nephron using an Eulerian two-phase mathematical framework. Parametric simulation are performed to study stone size enhancement and steady state volume fraction distributions in the four main sections of the nephron under weightlessness conditions. Contribution of agglomeration to the stone size distribution and effect of wall friction on the stone volume fraction distributions are carefully examined. Case studies using measured astronaut urinary calcium and oxalate concentrations in microgravity as input indicate that under nominal conditions the largest stone sizes developed in Space will be still considerably below the critical range for problematic stone development. However, results also indicate that the highest stone volume fraction occurs next to the tubule and duct walls. This suggests that there is an increased potential for wall adhesion with the possibility of evolution towards critical stone sizes.

Microgravity↗

Coupled CFD-PBE Predictions of Renal Stone Size Distributions in the Nephron in Microgravity

In this paper, a deterministic model is developed to assess the risk of critical renal stone formation for astronauts during space travel. A Population Balance Equation (PBE) model is used to compute the size distribution of a population of nucleating, growing and agglomerating renal calculi as they are transported through different sections of the nephron. The PBE model is coupled to a Computational Fluid Dynamics (CFD) model that solves for steady state flow of urine and transport of renal calculi along with the concentrations of ionic species, calcium and oxalate, in the nephron using an Eulerian two-phase mathematical framework. Parametric simulation are performed to study stone size enhancement and steady state volume fraction distributions in the four main sections of the nephron under weightlessness conditions. Contribution of agglomeration to the stone size distribution and effect of wall friction on the stone volume fraction distributions are carefully examined. Case studies using measured astronaut urinary calcium and oxalate concentrations in microgravity as input indicate that under nominal conditions the largest stone sizes developed in Space will be still considerably below the critical range for problematic stone development. However, results also indicate that the highest stone volume fraction occurs next to the tubule and duct walls. This suggests that there is an increased potential for wall adhesion with the possibility of evolution towards critical stone sizes.

Crystal Growth↗

Environmental qualification testing of payload G-534, the Pool Boiling Experiment

Payload G-534, the prototype Pool Boiling Experiment (PBE), is scheduled to fly on the STS-47 mission in September 1992. This paper describes the purpose of the experiment and the environmental qualification testing program that was used to prove the integrity of the hardware. Component and box level vibration and thermal cycling tests were performed to give an early level of confidence in the hardware designs. At the system level, vibration, thermal extreme soaks, and thermal vacuum cycling tests were performed to qualify the complete design for the expected shuttle environment. The system level vibration testing included three axis sine sweeps and random inputs. The system level hot and cold soak tests demonstrated the hardware's capability to operate over a wide range of temperatures and gave wider latitude in determining which shuttle thermal attitudes were compatible with the experiment. The system level thermal vacuum cycling tests demonstrated the hardware's capability to operate in a convection free environment. A unique environmental chamber was designed and fabricated by the PBE team and allowed most of the environmental testing to be performed within the hardware build laboratory. The completion of the test program gave the project team high confidence in the hardware's ability to function as designed during flight.

Sexton, J. Andrew↗

Environmental qualification testing of the prototype pool boiling experiment

The prototype Pool Boiling Experiment (PBE) flew on the STS-47 mission in September 1992. This report describes the purpose of the experiment and the environmental qualification testing program that was used to prove the integrity of the prototype hardware. Component and box level vibration and thermal cycling tests were performed to give an early level of confidence in the hardware designs. At the system level, vibration, thermal extreme soaks, and thermal vacuum cycling tests were performed to qualify the complete design for the expected shuttle environment. The system level vibration testing included three axis sine sweeps and random inputs. The system level hot and cold soak tests demonstrated the hardware's capability to operate over a wide range of temperatures and gave the project team a wider latitude in determining which shuttle thermal altitudes were compatible with the experiment. The system level thermal vacuum cycling tests demonstrated the hardware's capability to operate in a convection free environment. A unique environmental chamber was designed and fabricated by the PBE team and allowed most of the environmental testing to be performed within the project's laboratory. The completion of the test program gave the project team high confidence in the hardware's ability to function as designed during flight.

Sexton, J. Andrew↗

Impact of random pointing and tracking errors on the design of coherent and incoherent optical intersatellite communication links

Given the rms transmitter pointing error and the desired probability of bit error (PBE), it can be shown that an optimal transmitter antenna gain exists which minimizes the required transmitter power. Given the rms local oscillator tracking error, an optimum receiver antenna gain can be found which optimizes the receiver performance. The impact of pointing and tracking errors on the design of direct-detection pulse-position modulation (PPM) and heterodyne noncoherent frequency-shift keying (NCFSK) systems are then analyzed in terms of constraints on the antenna size and the power penalty incurred. It is shown that in the limit of large spatial tracking errors, the advantage in receiver sensitivity for the heterodyne system is quickly offset by the smaller antenna gain and the higher power penalty due to tracking errors. In contrast, for systems with small spatial tracking errors, the heterodyne system is superior because of the higher receiver sensitivity.

Chen, Chien-Chung↗

Electrical design of payload G-534: The Pool Boiling Experiment

Payload G-534, the Pool Boiling Experiment (PBE), is a Get Away Special that is scheduled to fly on the shuttle in 1992. This paper will give a brief overall description of the experiment with the main discussion being the electrical design with a detailed description of the power system and interface to the GAS electronics. The batteries used and their interface to the experiment Power Control Unit (PCU) and GAS electronics will be examined. The design philosophy for the PCU will be discussed in detail. The criteria for selection of fuses, relays, power semiconductors and other electrical components along with grounding and shielding policy for the entire experiment will be presented. The intent of this paper is to discuss the use of military tested parts and basic design guidelines to build a quality experiment for minimal additional cost.

Francisco, David R.↗

Electrical design of Space Shuttle payload G-534: The pool boiling experiment

Payload G-534, the Pool Boiling Experiment (PBE), is a Get Away Special (GAS) payload that flew on the Space Shuttle Spacelab Mission J (STS 47) on September 19-21, 1992. This paper will give a brief overall description of the experiment with the main discussion being the electrical design with a detailed description of the power system and interface to the GAS electronics. The batteries used and their interface to the experiment Power Control Unit (PCU) and GAS electronics will be examined. The design philosophy for the PCU will be discussed in detail. The criteria for selection of fuses, relays, power semiconductors, and other electrical components along with grounding and shielding policy for the entire experiment are presented. The intent of this paper is to discuss the use of military tested parts and basic design guidelines to build a quality experiment for minimal additional cost.

Francisco, David R.↗

Pool Boiling Experiment Has Successful Flights

The Pool Boiling Experiment (PBE) is designed to improve understanding of the fundamental mechanisms that constitute nucleate pool boiling. Nucleate pool boiling is a process wherein a stagnant pool of liquid is in contact with a surface that can supply heat to the liquid. If the liquid absorbs enough heat, a vapor bubble can be formed. This process occurs when a pot of water boils. On Earth, gravity tends to remove the vapor bubble from the heating surface because it is dominated by buoyant convection. In the orbiting space shuttle, however, buoyant convection has much less of an effect because the forces of gravity are very small. The Pool Boiling Experiment was initiated to provide insight into this nucleate boiling process, which has many Earthbound applications, such as steam-generation power plants, petroleum, and other chemical plants. Also, by using the test fluid R-113, the Pool Boiling Experiment can provide some basic understanding of the boiling behavior of cryogenic fluids without the large cost of an experiment using an actual cryogen.

Source record↗

Pool Boiling Experiment Has Five Successful Flights

The Pool Boiling Experiment (PBE) is designed to improve understanding of the fundamental mechanisms that constitute nucleate pool boiling. Nucleate pool boiling is a process wherein a stagnant pool of liquid is in contact with a surface that can supply heat to the liquid. If the liquid absorbs enough heat, a vapor bubble can be formed. This process occurs when a pot of water boils. On Earth, gravity tends to remove the vapor bubble from the heating surface because it is dominated by buoyant convection. In the orbiting space shuttle, however, buoyant convection has much less of an effect because the forces of gravity are very small. The Pool Boiling Experiment was initiated to provide insight into this nucleate boiling process, which has many earthbound applications in steamgeneration power plants, petroleum plants, and other chemical plants. In addition, by using the test fluid R-113, the Pool Boiling Experiment can provide some basic understanding of the boiling behavior of cryogenic fluids without the large cost of an experiment using an actual cryogen.

Chiaramonte, Fran↗

Prediction of Calcium Oxalate Stone Risk with Interventions

Introduction Mitigations intended to reduce bone mineral loss in-flight also influence the level of renal stone risk to astronauts. Extending a recent study completed by our group [1], we investigate the likely influence of combined fluid intake and Ca excretion mitigation strategies. Methods A computational biochemistry model representing CaOx crystal precipitation, growth, and agglomeration [2] is combined with a probabilistic analysis to predict the in-flight CaOx renal stone incidence risk ratio (IRR) relative to pre-flight values using 1517 astronaut 24-hour urine chemistries. The output of this simulation is used to assess the combined impact of controlling fluid intake and Ca excretion on maintaining IRR < 1.2 for > 95% of the population, a threshold determined from initial analysis of the model output compared to referent populations [1]. Results and Conclusions Figure 1 illustrates the simulated in-flight astronaut population (n=40000) with CaOx IRR > 1.2. The red lines indicate the known clinical risk boundary of each factor, and the white box is considered the area of high combined clinical risk. The simulation and identified risk threshold conform well to the expected clinical risk boundaries. The results, assuming insensible water losses equal or exceed 0.7 L/day, imply mitigations achieve risks similar to pre-flight levels when either Ca < 150 mg/day or fluid volume intake > 3.2 L/day individually, or combined Ca < 200 and fluid volume intake > 2.5 L/day. We continue to investigate similar compounded effects and look to apprise engineering trades by informing relative risk changes during mission design. References [1] D. A. Goodenow-Messman, S. A. Gokoglu, M. Kassemi, and J. Myers, Jerry G., “Characterization of Astronaut CaOx Renal Stone Incidence Rates to Quantify In-flight and Post-flight Relative Risk,” npj Microgravity, in review, 2021. [2] M. Kassemi and D. Thompson, “Prediction of renal crystalline size distributions in space using a PBE analytic model. 1. Effect of microgravity-induced biochemical alterations,” Am. J. Physiol. Physiol., vol. 311, no. 3, pp. F520–F530, Sep. 2016, doi: 10.1152/ajprenal.00401.2015.

Debra A Goodenow↗