Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

From Space to the Patient: A New Cytokine Release Assay to Monitor the Immune Status of HIV Infected Patients and Sepsis Patients

Monitoring of humans either in the healthy men under extreme environmental stress like space flight, in human immunodeficiency virus (HIV) infected patients or in sepsis is of critical importance with regard to the timing of adequate therapeutic (counter-)measures. The in vivo skin delayed-type hypersensitivity test (DTH) served for many years as a tool to evaluate cell mediated immunity. However, this standardised in vivo test was removed from the market in 2002 due to the risk of antigen stabilization. To the best of our knowledge an alternative test as monitoring tool to determine cell mediated immunity is not available so far. For this purpose we tested a new alternative assay using elements of the skin DTH which is based on an ex vivo cytokine release from whole blood and asked if it is suitable and applicable to monitor immune changes in HIV infected patients and in patients with septic shock.

Kaufmann, I.↗

Estimated dose rates to members of the public from external exposure to patients with {sup 131}I thyroid treatment

Purpose: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ({sup 131}I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered {sup 131}I. Methods: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with {sup 131}I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the {sup 131}I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient’s bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of {sup 131}I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after {sup 131}I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ specific activities of {sup 131}I in the thyroid, bladder, and combined remaining tissues were calculated as a function of time after administration. Exposures to members of the public were considered for {sup 131}I patients with normal thyroid uptake (peak thyroid uptake of ∼27% of administered {sup 131}I), differentiated thyroid cancer (DTC, 5% uptake), and hyperthyroidism (80% uptake). Results: The scenario with the patient seated behind the member of the public yielded the highest dose rate estimate of seated public transportation exposure cases. The dose rate to the adjacent room guest was highest for the exposure scenario in which the hotel guest and patient are seated by a factor of ∼4 for the normal and differentiated thyroid cancer uptake cases and by a factor of ∼3 for the hyperthyroid case. Conclusions: It was determined that for all modeled cases, the DTC case yielded the lowest external dose rates, whereas the hyperthyroid case yielded the highest dose rates. In estimating external dose to members of the public from patients with {sup 131}I therapy, consideration must be given to (patient- and case-specific) administered {sup 131}I activities and duration of exposure for a more complete estimate. The method implemented here included a detailed calculation model, which provides a means to determine dose rate estimates for a range of scenarios. The method was demonstrated for variations of three scenarios, showing how dose rates are expected to vary with uptake, voiding pattern, and patient location.

60 APPLIED LIFE SCIENCES↗

Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDI{sub vol} underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.

60 APPLIED LIFE SCIENCES↗

Predicting objective function weights from patient anatomy in prostate IMRT treatment planning

Purpose: Intensity-modulated radiation therapy (IMRT) treatment planning typically combines multiple criteria into a single objective function by taking a weighted sum. The authors propose a statistical model that predicts objective function weights from patient anatomy for prostate IMRT treatment planning. This study provides a proof of concept for geometry-driven weight determination. Methods: A previously developed inverse optimization method (IOM) was used to generate optimal objective function weights for 24 patients using their historical treatment plans (i.e., dose distributions). These IOM weights were around 1% for each of the femoral heads, while bladder and rectum weights varied greatly between patients. A regression model was developed to predict a patient's rectum weight using the ratio of the overlap volume of the rectum and bladder with the planning target volume at a 1 cm expansion as the independent variable. The femoral head weights were fixed to 1% each and the bladder weight was calculated as one minus the rectum and femoral head weights. The model was validated using leave-one-out cross validation. Objective values and dose distributions generated through inverse planning using the predicted weights were compared to those generated using the original IOM weights, as well as an average of the IOM weights across all patients. Results: The IOM weight vectors were on average six times closer to the predicted weight vectors than to the average weight vector, usingl{sub 2} distance. Likewise, the bladder and rectum objective values achieved by the predicted weights were more similar to the objective values achieved by the IOM weights. The difference in objective value performance between the predicted and average weights was statistically significant according to a one-sided sign test. For all patients, the difference in rectum V54.3 Gy, rectum V70.0 Gy, bladder V54.3 Gy, and bladder V70.0 Gy values between the dose distributions generated by the predicted weights and IOM weights was less than 5 percentage points. Similarly, the difference in femoral head V54.3 Gy values between the two dose distributions was less than 5 percentage points for all but one patient. Conclusions: This study demonstrates a proof of concept that patient anatomy can be used to predict appropriate objective function weights for treatment planning. In the long term, such geometry-driven weights may serve as a starting point for iterative treatment plan design or may provide information about the most clinically relevant region of the Pareto surface to explore.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate and Patient Intrafraction Motion: Impact on Treatment Time-Dependent Planning Margins for Patients With Endorectal Balloon

Purpose: To investigate intrafraction prostate and patient motion during different radiation therapy treatments as a function of treatment time; included were prostate patients with an endorectal balloon (ERB). Margins accounting for setup uncertainties and intrafraction motion were determined. Methods and Materials: The study included 17 patients undergoing prostate cancer radiation therapy. All patients received 3 fiducial gold markers implanted in the prostate and were then immobilized in the supine position with a knee support and treated with an ERB. Twelve patients with intermediate risk for pelvic lymph node metastases received intensity modulated radiation therapy (IMRT), and 5 patients at low risk received a 4-field box treatment. After setup based on skin marks, patients were imaged with a stereoscopic imaging system. If the marker displacement exceeded a 3-mm tolerance relative to planning computed tomography, patients were shifted and verification images were taken. All patients underwent additional imaging after treatment; IMRT patients also received additional imaging at halftime of treatment. Prostate and bone drifts were evaluated as a function of treatment time for more than 600 fractions, and margins were extracted. Results: Patient motion evaluated by bone match was strongly patient dependent but in general was smallest in the superior-inferior (SI) direction. Prostate drifts were less patient dependent, showing an increase with treatment time in the SI and anterior-posterior (AP) directions. In the lateral (LAT) direction, the prostate stayed rather stable. Mean treatment times were 5.5 minutes for 4-field box, 10 minutes for 5-field boost IMRT, and 15 minutes or more for 9-field boost and 9-field pelvic IMRT treatments. Margins resulted in 2.2 mm, 3.9 mm, and 4.3 mm for 4-field box; 3.7 mm, 2.6 mm, and 3.6 mm for 5-field boost IMRT; 2.3 mm, 3.9 mm, and 6.2 mm for 9-field boost IMRT; and 4.2 mm, 5.1 mm, and 6.6 mm for 9-field pelvic IMRT in the LAT, SI, and AP directions, respectively. Conclusion: Intrafraction prostate and patient displacement increased with treatment time, showing different behaviors for the single directions of movement. Repositioning of the patients during long treatments or shorter treatment times will be necessary to further reduce the treatment margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Outcome for Patients With Pathologic Node-Positive Prostate Cancer Treated With Intensity Modulated Radiation Therapy and Androgen Deprivation Therapy: A Case-Matched Analysis of pN1 and pN0 Patients

Purpose: Improved outcome is reported after surgery or external beam radiation therapy (EBRT) plus androgen deprivation therapy (ADT) for patients with lymph node (LN) positive (N1) prostate cancer (PC). Surgical series have shown that pathologic (p)N1 PC does not behave the same in all patients. The aim of this study was to perform a matched-case analysis to compare the outcome of pN1 and pN0 PC after high-dose EBRT plus ADT. Methods and Materials: Radiation therapy up to 80 Gy was delivered to the prostate with a minimal dose of 45 Gy to the pelvis for pN1 patients. After matching, Kaplan-Meier statistics were used to compare the 5-year biochemical and clinical relapse-free survival (bRFS and cRFS), prostate cancer–specific survival (PCSS), and overall survival (OS). Acute and late rectal and urinary toxicity was evaluated. Results: Sixty-nine pN1 PC patients were matched 1:1 with pN0 PC patients. The median follow-up time was 60 months. The 5-year bRFS and cRFS for pN1 versus pN0 PC patients were 65% ± 7% versus 79% ± 5% (P=.08) and 70% ± 6% versus 83% ± 5% (P=.04) respectively. No significant difference was found in bRFS or cRFS rates between low volume pN1 (≤2 positive LNs) and pN0 patients. The 5-year PCSS and OS were comparable between pN1 and pN0 PC patients: PCSS: 92% ± 4% versus 93% ± 3% (P=.66); OS: 82% ± 5% versus 80% ± 5% (P=.58). Severe toxicity was rare for both groups, although pN1 patients experienced significantly more acute grade 2 rectal toxicity. Conclusion: Primary EBRT plus 2 to 3 years of ADT is a legitimate treatment option for pN1 PC patients, especially those with ≤2 positive LNs, and this with bRFS and cRFS rates comparable to those in pN0 PC patients. For pN1 PC patients with >2 positive LNs, bRFS and cRFS are worse than in pN0 patients, but even in this subgroup, long-term disease control is obtained.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck

Purpose: To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Methods: Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. Results: The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or −0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1–2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39–16.8) cGy, or 10.1 (0.8–32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%–9.06%) and 10.2% (0.7%–63.6%), respectively. Conclusions: Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup, the standard deviation of setup error reduced by 31%, 42%, and 54% in RL, AP, and SI direction, respectively, and consequently, the uncertainty of the mean dose to cochlea reduced more than 50%. The authors estimate that the effects of these uncertainties on the probability of hearing loss for an individual patient could be as large as 10%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Pathologic Upgrading or Locally Advanced Disease in Early Prostate Cancer Patients Based on Biopsy Gleason Score and PSA: A Population-Based Study of Modern Patients

Purpose: Radiation oncologists rely on available clinical information (biopsy Gleason score and prostate-specific antigen [PSA]) to determine the optimal treatment regimen for each prostate cancer patient. Existing published nomograms correlating clinical to pathologic extent of disease were based on patients treated in the 1980s and 1990s at select academic institutions. We used the Surveillance, Epidemiology, and End Results (SEER) database to examine pathologic outcomes (Gleason score and cancer stage) in early prostate cancer patients based on biopsy Gleason score and PSA concentration. Methods and Materials: This analysis included 25,858 patients whose cancer was diagnosed between 2010 and 2011, with biopsy Gleason scores of 6 to 7 and clinical stage T1 to T2 disease, who underwent radical prostatectomy. In subgroups based on biopsy Gleason score and PSA level, we report the proportion of patients with pathologically advanced disease (positive surgical margin or pT3-T4 disease) or whose Gleason score was upgraded. Logistic regression was used to examine factors associated with pathologic outcomes. Results: For patients with biopsy Gleason score 6 cancers, 84% of those with PSA <10 ng/mL had surgical T2 disease with negative margins; this decreased to 61% in patients with PSA of 20 to 29.9 ng/mL. Gleason score upgrading was seen in 43% (PSA: <10 ng/mL) to 61% (PSA: 20-29.9 ng/mL) of biopsy Gleason 6 patients. Patients with biopsy Gleason 7 cancers had a one-third (Gleason 3 + 4; PSA: <10 ng/mL) to two-thirds (Gleason 4 + 3; PSA: 20-29.9 ng/mL) probability of having pathologically advanced disease. Gleason score upgrading was seen in 11% to 19% of patients with biopsy Gleason 4 + 3 cancers. Multivariable analysis showed that higher PSA and older age were associated with Gleason score upgrading and pathologically advanced disease. Conclusions: This is the first population-based study to examine pathologic extent of disease and pathologic Gleason score upgrading based on clinically available information in modern patients. These data inform the selection of radiation therapy strategies and an understanding of whether prostatectomy alone is likely to be curative for patients with early prostate cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Weight Change During the Course of Concurrent Chemoradiation Therapy on Outcomes in Stage IIIB Non-Small Cell Lung Cancer Patients: Retrospective Analysis of 425 Patients

Purpose: We retrospectively investigated the impact of weight change (WC) during concurrent chemoradiation therapy (C-CRT) on clinical outcomes of stage 3B non-small cell lung cancer (NSCLC) patients. Methods and Materials: A total of 425 patients treated with C-CRT were included. All patients received 60 to 66 Gy of thoracic radiation therapy concurrently with 1 to 3 cycles of platinum-based chemotherapy. Pre- and posttreatment weight measurements on first and last days of C-CRT were used for WC. Patients were divided into 2 groups: group 1 = weight loss (WL); group 2 = weight preservation/gain (WP) for comparative analyses. Results: Following C-CRT, 252 patients (59.3%) experienced WL, while 89 patients (20.9%) and 84 patients (19.8%) showed WP or WG. At median 24.2 months of follow-up, 142 patients (33.4%) were alive (84 WP [48.6%] and 58 WL [23.0%]), and 58 (13.6%) of them were free of disease progression (41 [23.7%] for WP and 17 [6.7%] for WL). Median overall survival (OS), locoregional progression-free survival (LRPFS), progression-free survival (PFS), and distant metastases-free survival (DMFS) for the entire population were 22.8, 14.4, 10.6, and 11.7 months, respectively. Intergroup comparisons between WP and WL cohorts revealed significantly superior OS, LRPFS, PFS, and DMFS in WP patients (P<.05 for each). On multivariate analyses, only WL and advanced T stage were associated with poor prognosis (P<.05). Conclusions: Present results in 425 stage 3B NSCLC patients demonstrated that WL during C-CRT is strongly associated with inferior survival outcomes compared to WP. This emerging finding might be useful by forming an encouraging basis for future investigations in facilitating a way to improve the outcomes of these patients experiencing WL during C-CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Escalated Stereotactic Body Radiation Therapy for Patients With Intermediate- and High-Risk Prostate Cancer: Initial Dosimetry Analysis and Patient Outcomes

Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the target volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Outcome After Radiotherapy in Patients With Atypical and Malignant Meningiomas-Clinical Results in 85 Patients Treated in a Single Institution Leading to Optimized Guidelines for Early Radiation Therapy

Purpose: Previously, we could show that the new World Health Organization (WHO) classification of meningiomas significantly correlated with outcome in patients with atypical and anaplastic histology. In the present work, we analyzed our long-term experience in radiotherapy for atypical and malignant meningioma diagnosed according to the most recent WHO categorization system. Patients and Methods: Sixty-two patients with atypical and 23 patients with malignant meningioma have been treated with radiotherapy. Sixty percent of all patients received radiotherapy (RT) after surgical resection, 19% at disease progression and 8.3% as a primary treatment. Radiation was applied using different techniques including fractionated stereotactic RT (FSRT), intensity-modulated RT, and combination treatment with carbon ions. The median PTV was 156.0 mL. An average dose of 57.6 Gy (range, 30-68.4 Gy) in 1.8-3 Gy fractions was applied. All patients were followed regularly including clinical-neurological follow-up as well as computed tomographies or magnetic resonance imaging. Results: Overall survival was impacted significantly by histological grade, with 81% and 53% at 5 years for atypical or anaplastic meningiomas, respectively. This difference was significant at p = 0.022. Eighteen patients died of tumor progression during follow-up. Progression-free survival was 95% and 50% for atypical, and 63% and 13% for anaplastic histology at 2 and 5 years. This difference was significant at p = 0.017. Despite histology, we could not observe any prognostic factors including age, resection status, or Karnofsky performance score. However, preexisting clinical symptoms observed in 63 patients improved in 29.3% of these patients. Conclusion: RT resulted in improvement of preexisting clinical symptoms; outcome is comparable to other series reported in the literature. RT should be offered after surgical resection after initial diagnosis to increase progression-free survival as well as overall survival. Novel clinical concepts are under investigation to further improve outcome in patients with high-grade meningiomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Patient Reporting of Symptomatic Adverse Events via the Patient-Reported Outcomes Version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE) in a Chemoradiotherapy Cooperative Group Multicenter Clinical Trial

Purpose: To assess the feasibility of measuring symptomatic adverse events (AEs) in a multicenter clinical trial using the National Cancer Institute's Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE). Methods and Materials: Patients enrolled in NRG Oncology's RTOG 1012 (Prophylactic Manuka Honey for Reduction of Chemoradiation Induced Esophagitis-Related Pain during Treatment of Lung Cancer) were asked to self-report 53 PRO-CTCAE items representing 30 symptomatic AEs at 6 time points (baseline; weekly ×4 during treatment; 12 weeks after treatment). Reporting was conducted via wireless tablet computers in clinic waiting areas. Compliance was defined as the proportion of visits when an expected PRO-CTCAE assessment was completed. Results: Among 226 study sites participating in RTOG 1012, 100% completed 35-minute PRO-CTCAE training for clinical research associates (CRAs); 80 sites enrolled patients, of which 34 (43%) required tablet computers to be provided. All 152 patients in RTOG 1012 agreed to self-report using the PRO-CTCAE (median age 66 years; 47% female; 84% white). Median time for CRAs to learn the system was 60 minutes (range, 30-240 minutes), and median time for CRAs to teach a patient to self-report was 10 minutes (range, 2-60 minutes). Compliance was high, particularly during active treatment, when patients self-reported at 86% of expected time points, although compliance was lower after treatment (72%). Common reasons for noncompliance were institutional errors, such as forgetting to provide computers to participants; patients missing clinic visits; Internet connectivity; and patients feeling “too sick.” Conclusions: Most patients enrolled in a multicenter chemoradiotherapy trial were willing and able to self-report symptomatic AEs at visits using tablet computers. Minimal effort was required by local site staff to support this system. The observed causes of missing data may be obviated by allowing patients to self-report electronically between visits, and by using central compliance monitoring. These approaches are being incorporated into ongoing studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: A simulation study using patient data

Purpose: 3D optical surface imaging has been applied to patient positioning in radiation therapy (RT). The optical patient positioning system is advantageous over conventional method using cone-beam computed tomography (CBCT) in that it is radiation free, frameless, and is capable of real-time monitoring. While the conventional radiographic method uses volumetric registration, the optical system uses surface matching for patient alignment. The relative accuracy of these two methods has not yet been sufficiently investigated. This study aims to investigate the theoretical accuracy of the surface registration based on a simulation study using patient data. Methods: This study compares the relative accuracy of surface and volumetric registration in head-and-neck RT. The authors examined 26 patient data sets, each consisting of planning CT data acquired before treatment and patient setup CBCT data acquired at the time of treatment. As input data of surface registration, patient’s skin surfaces were created by contouring patient skin from planning CT and treatment CBCT. Surface registration was performed using the iterative closest points algorithm by point–plane closest, which minimizes the normal distance between source points and target surfaces. Six degrees of freedom (three translations and three rotations) were used in both surface and volumetric registrations and the results were compared. The accuracy of each method was estimated by digital phantom tests. Results: Based on the results of 26 patients, the authors found that the average and maximum root-mean-square translation deviation between the surface and volumetric registrations were 2.7 and 5.2 mm, respectively. The residual error of the surface registration was calculated to have an average of 0.9 mm and a maximum of 1.7 mm. Conclusions: Surface registration may lead to results different from those of the conventional volumetric registration. Only limited accuracy can be achieved for patient positioning with an approach based solely on surface information.

60 APPLIED LIFE SCIENCES↗

Patient-Reported Outcomes in Pediatric Cancer Registration Trials: A US Food and Drug Administration Perspective

Pediatric patient-reported outcome (PRO) data can help inform the US Food and Drug Administration’s (FDA’s) benefit-risk assessment of cancer therapeutics by quantifying symptom and functional outcomes from the patient’s perspective. This study assessed use of PROs in commercial pediatric oncology trials submitted to the FDA for regulatory review. FDA databases were searched to identify pediatric oncology product applications approved between 1997 and 2020. Sponsor-submitted documents were reviewed to determine whether PRO data were collected, which instruments were used, and the quality of collected data (ie, sample size, completion rates, and use of fit-for-purpose instruments). The role of PROs in each trial (endpoint hierarchy) was also recorded in addition to whether any PRO endpoints were included in product labeling. We reviewed 17 pediatric oncology applications, 4 of which included PRO data: denosumab, tisagenlecleucel, larotrectinib, and selumetinib. In these 4 instances, PROs served as exploratory endpoints and were not incorporated in product labeling. Trials that collected PRO data were phase II or phase I/II single-arm studies with sample sizes of 28 to 88 patients. Symptomatic adverse events (AEs) were characterized using clinician-reported Common Terminology Criteria for Adverse Events (CTCAE) without additional patient self-report. PROs were infrequently used in pediatric cancer registration trials. When PROs were used, PRO data were limited by lack of a clear research objective and corresponding prospective statistical analysis plan. Contemporary PRO symptom libraries, such as the National Cancer Institute’s Pediatric PRO-CTCAE, may provide an opportunity to better evaluate the occurrence and impact of symptomatic AEs, from the patient’s perspective, in pediatric oncology trials.

Oncology↗

Optimal Timing for Assessment of Tumor Response to Neoadjuvant Chemoradiation in Patients With Rectal Cancer: Do All Patients Benefit From Waiting Longer Than 6 Weeks?

Purpose: To estimate the metabolic activity of rectal cancers at 6 and 12 weeks after completion of chemoradiation therapy (CRT) by 2-[fluorine-18] fluoro-2-deoxy-D-glucose-labeled positron emission tomography/computed tomography ([{sup 18}FDG]PET/CT) imaging and correlate with response to CRT. Methods and Materials: Patients with cT2-4N0-2M0 distal rectal adenocarcinoma treated with long-course neoadjuvant CRT (54 Gy, 5-fluouracil-based) were prospectively studied ( (ClinicalTrials.org) identifier (NCT00254683)). All patients underwent 3 PET/CT studies (at baseline and 6 and 12 weeks from CRT completion). Clinical assessment was at 12 weeks. Maximal standard uptake value (SUVmax) of the primary tumor was measured and recorded at each PET/CT study after 1 h (early) and 3 h (late) from {sup 18}FDG injection. Patients with an increase in early SUVmax between 6 and 12 weeks were considered 'bad' responders and the others as 'good' responders. Results: Ninety-one patients were included; 46 patients (51%) were 'bad' responders, whereas 45 (49%) patients were 'good' responders. 'Bad' responders were less likely to develop complete clinical response (6.5% vs. 37.8%, respectively; P=.001), less likely to develop significant histological tumor regression (complete or near-complete pathological response; 16% vs. 45%, respectively; P=.008) and exhibited greater final tumor dimension (4.3 cm vs. 3.3 cm; P=.03). Decrease between early (1 h) and late (3 h) SUVmax at 6-week PET/CT was a significant predictor of 'good' response (accuracy of 67%). Conclusions: Patients who developed an increase in SUVmax after 6 weeks were less likely to develop significant tumor downstaging. Early-late SUVmax variation at 6-week PET/CT may help identify these patients and allow tailored selection of CRT-surgery intervals for individual patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of Patient Benefit From Proton Therapy for Advanced Head and Neck Cancer Patients Based on Individual and Subgroup Normal Tissue Complication Probability Analysis

Purpose: The purpose of this study was to determine, by treatment plan comparison along with normal tissue complication probability (NTCP) modeling, whether a subpopulation of patients with head and neck squamous cell carcinoma (HNSCC) could be identified that would gain substantial benefit from proton therapy in terms of NTCP. Methods and Materials: For 45 HNSCC patients, intensity modulated radiation therapy (IMRT) was compared to intensity modulated proton therapy (IMPT). Physical dose distributions were evaluated as well as the resulting NTCP values, using modern models for acute mucositis, xerostomia, aspiration, dysphagia, laryngeal edema, and trismus. Patient subgroups were defined based on primary tumor location. Results: Generally, IMPT reduced the NTCP values while keeping similar target coverage for all patients. Subgroup analyses revealed a higher individual reduction of swallowing-related side effects by IMPT for patients with tumors in the upper head and neck area, whereas the risk reduction of acute mucositis was more pronounced in patients with tumors in the larynx region. More patients with tumors in the upper head and neck area had a reduction in NTCP of more than 10%. Conclusions: Subgrouping can help to identify patients who may benefit more than others from the use of IMPT and, thus, can be a useful tool for a preselection of patients in the clinic where there are limited PT resources. Because the individual benefit differs within a subgroup, the relative merits should additionally be evaluated by individual treatment plan comparisons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗