Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Volatile particles measured by vapor-particle separator

Vapor-Particle Separator (VPS) is a new technology developed for characterization of the volatile fraction of particulate matter in a combustion aerosol population. VPS incorporates a novel metallic membrane and operates in a cross-flow filtration mode for separation of vapor and solid (i.e. non-volatile) particles. Demonstration of the VPS technology on aircraft engine-emitted particles has led to the improvement of the technology and increased confidence on the robustness of its field performance. In this study, the performance of the VPS was evaluated against the Particle Measurement Programme (PMP) volatile particle remover (VPR), a standardized device used in heavy duty diesel engines for separation and characterization of non-volatile particulate matter. Using tetracontane particles in the laboratory reveals that the VPS performed reasonably well in removing the volatile species. In the field conditions, a single-mode particle size distribution was found for emitted particles from a T63 turboshaft engine at both idle and cruise engine power conditions. Removal of the volatile T63 engine particles by the VPS was consistent with that of PMP VPR. In tests on an F117 turbofan engine, the size distribution at the idle (4% rated) engine power condition was found to be bimodal, with the first mode consisting of particles smaller than 10nm, which are believed to be mostly semi-volatile particles, while the second mode of larger size was a mixture of semi-volatile and non-volatile particles. The distribution was single modal at the 33% rated engine power with no secondary mode observed. Altogether, for particles emitted by both engines, the removal efficiency of the VPS appears to surpass that of the PMP VPR by 8-10%.

42 ENGINEERING↗

Enhanced Detection of Primary Biological Aerosol Particles Using Machine Learning and Single-Particle Measurement

Accurately identifying primary biological aerosol particles (PBAPs) using analytical techniques poses inherent challenges due to their resemblance to other atmospheric carbonaceous particles. Here, we present a study of an enhanced method for detecting PBAPs by combining single-particle measurement with advanced supervised machine learning (SML) techniques. We analyzed ambient particles from a variety of environments and lab-generated standards, focusing on chemical composition for traditional rule-based and clustering approaches and incorporating morphological features into the SML approaches, neural networks and XGBoost, for improved accuracy. This study demonstrates that SML methods outperform traditional methods in quantifying PBAPs, achieving significant improvements in precision, recall, F1-score, and accuracy, leading to an increased number of detected PBAPs by at least 19%. The adaptability of the proposed XGBoost-based SML model is showcased in comparison to traditional methods in categorizing PBAPs for blind data sets from different geographical locations. Two field case studies were investigated, over agricultural land and Amazonia rain forest, representing relatively low and high concentrations of PBAPs, respectively, where XGBoost consistently detected up to 3.5 times more PBAPs than traditional methods. Precise detection of PBAPs in the atmosphere could significantly improve the prediction of climatic impacts by them.

42 ENGINEERING↗

Differential emissivity based evaporable particle measurement

A differential emissivity imaging device for measuring evaporable particle properties can include a heated plate, a thermal camera, a memory device, and an output interface. The heated plate can have an upper surface oriented to receive falling evaporable particles. The evaporable particles have a particle emissivity and the upper surface has a plate surface emissivity. The thermal camera can be oriented to produce a thermal image of the upper surface. A memory device can include instructions that cause the imaging device to calculate a mass of the individual evaporable particle via heat conduction using a calculated surface area and an evaporation time.

Garrett, Tim↗

Macquarie Island Cloud and Radiation Experiment (MICRE) Ice Nucleating Particle Measurements Field Campaign Report

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Macquarie Island Cloud and Radiation Experiment (MICRE) Ice Nucleating Particle Measurements campaign was aligned as a supplemental activity with the second year of the overall MICRE campaign. The purpose of the supplemental campaign was to provide a first-ever annual cycle of ice nucleating particle (INP) measurements at a Southern Ocean (SO) site, toward the investigation/characterization of sources of INPs in the marine boundary layer as being from the production or primary sea spray aerosol (SSA) emissions versus other long-range transport influences. Furthermore, measuring the variability in INPs seasonally in this region, as this may relate to meteorology and ocean biological processes, is expected to help constrain (via parameterizations) numerical model simulations of cloud phase and regional climate. In concert with other SO studies during the time frame of the campaign (March 2017 to March 2018), MICRE sought to evaluate the hypotheses that SSA INPs represent the major INP source in the SO and, due to their generally less efficient INP activation properties compared to terrestrial sources, that they may directly influence the persistence of supercooled clouds in a unique manner for this climatic region. These measurements supplemented the original deployment of primarily radiation measurements provided in the ARM MICRE request and the associated Australian Antarctic Division (AAD) Antarctic Clouds and Radiation Experiment (ACRE). Assistance and collaboration was obtained from the AAD, the Commonwealth Scientific and Industrial Research Organization (CSIRO) and the Australian Bureau of Meteorology (BOM). Follow-up plans will include investigations with their additional aerosol, cloud, and radiative transfer measurements. AAD also saw to the transport to Australia and storage of filters at the end of the campaign. The added effort involved an average of twice-weekly collections (a 48-hour and a 72-hour collection) of pre-sterilized, open-faced, polycarbonate filter samples for post-processing of INP number concentrations and tests to analyze the nature of INP sources. Collections were made by AAD technician Emry Thaggard Crocker after online training from our team. Images of the filter sampler and site are shown in Figure 1. Sampling occurred from an approximate elevation of 4m MSL. Filters were returned frozen to Colorado State University (CSU) at the end of the campaign. Initial processing to obtain INP temperature spectra (0 to -28°C) of the concentrations of INPs active via the immersion freezing mechanism were conducted using the CSU ice spectrometer (IS) instrument systems (Hiranuma et al. 2015; McCluskey et al. 2018). In this method, particles are first removed from filters using ultrapure water while under mechanical agitation. Arrays of the particle suspensions from a portion of filter rinses are then cooled to obtain immersion freezing data per volume of water, and finally are related to sampling volumes to obtain numbers per volume of air following the analysis methods of Vali (1971). A total of 103 filters were collected, including blanks at selected intervals throughout the project. For archival and completion of tasks under this ARM proposal, nearly half of the filter collections (46) were processed for basic temperature spectra, and half of these (23) were also tested for microbial/proteinaceous contributions toward INPs via 95°C pre-treatment of portions of the original suspensions.

Southern Ocean, aerosols, marine clouds, MARCUS ca↗

Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) Ice Nucleating Particle Measurements Field Campaign Report

Evidence exists that sea-spray-sourced ice nucleating particles (INPs) are organic in origin, resulting from biological and biochemical processes in seawater and the sea surface microlayer, and represent a distinctly different and variable, but oftentimes much less effective, INP population in comparison to long-range transported desert dust (DeMott et al. 2016; McCluskey et al. 2018a). Over the Southern Ocean (SO), far from land sources, these INPs may dominate in the marine boundary layer (McCluskey et al. 2018b). Thereby, marine INPs may affect cloud phase and lifetime in this region where pervasive supercooled and mixed-phase boundary-layer clouds appear underrepresented in climate models. This motivated collection of ice nucleating particle concentration measurements during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Measurements of Aerosols, Radiation and Clouds over the Southern Ocean (MARCUS) deployment of the second ARM Mobile Facility (AMF2) on the Aurora Australis vessel from early November, 2017 (Austral spring) to late March, 2018 (Austral fall). During this period, four voyages were made from Hobart, Tasmania to the Australian Antarctic Division bases at Casey, Davis, and Mawson, as well as a final resupply cruise to Macquarie Island, the sight of the related Macquarie Island Cloud and Radiation Experiment (MICRE) campaign. Aerosol filter collections of alternating 24- and 48-hour duration were made during all voyages. These filters were returned frozen for subsequent processing to determine variability in the temperature spectrum of the concentrations of INPs active via the immersion freezing mechanism and to conduct additional analyses to indicate the chemical and biological nature of INPs over the SO. The MARCUS data set provides the first spatial and seasonal picture of INP concentrations over the SO in more than four decades, complementing the full annual cycle of INP data we collected for a point location in MICRE.

Ice nucleation, aerosols, arctic processes, marine↗

A precise measurement of the jet energy scale derived from single-particle measurements and in situ techniques in proton–proton collisions at $\sqrt{s}=$ 13 TeV with the ATLAS detector

The jet energy calibration and its uncertainties are derived from measurements of the calorimeter response to single particles in both data and Monte Carlo simulation using proton–proton collisions at $\sqrt{s} = 13$ TeV collected with the ATLAS detector during Run 2 at the Large Hadron Collider. The jet calibration uncertainty for anti-$k_T$ jets with a jet radius parameter of R$_\textrm{jet} = 0.4$ and in the central jet rapidity region is about 2.5% for transverse momenta ($p_{\text {T}}$) of 20 $\text {GeV}$ , about 0.5% for $p_{\text {T}} = 300$ GeV and 0.7% for $p_{\text {T}} = 4$ TeV . Excellent agreement is found with earlier determinations obtained from -balance based in situ methods ($Z/\gamma$ +jets). The combination of these two independent methods results in the most precise jet energy measurement achieved so far with the ATLAS detector with a relative uncertainty of 0.3% at $p_\textrm{T} = 300$ GeV and 0.6% at 4 TeV. The jet energy calibration is also derived with the single-particle calorimeter response measurements separately for quark- and gluon-induced jets and furthermore for jets with R jet varying from 0.2 to 1.0 retaining the correlations between these measurements. Differences between inclusive jets and jets from boosted top-quark decays, with and without grooming the soft jet constituents, are also studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New evaluation on angular distributions and energy spectra for neutron-induced charged-particle measurements

Recent development on neutron-induced charged particle reaction measurements can provide high-quality double differential cross sections at Los Alamos Neutron Science Center. With newly measured cross section data, we found lacking nuclear outputs for neutron-induced charged particle reactions in the latest ENDF/B-VIII.0 library, when compared with Monte Carlo simulations. Here, this paper presents how we improved the missing angular distributions and energy spectra for these reactions and the validation of our new evaluations with the measurements performed with the LENZ instrument at LANSCE. The impact of this additional evaluation is demonstrated by comparing the MCNP simulations with the LENZ experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Optical Particle Measurements during EPCAPE Field Campaign Report

This campaign requested the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility optical particle counter (OPC) at the first ARM Mobile Facility (AMF1) located at the Scripps Pier in La Jolla, California during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE). The addition of the OPC was requested for two reasons. (1) Close the gap between the scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) size distribution from the Aerosol Observing System (AOS) measurements. (2) Principal investigator Petters has been working with Tracking Aerosol Convection Interaction Experiment (TRACER) data to compute particle fluxes from Doppler lidar (Petters et al. 2024). Briefly, backscatter flux is obtained using the eddy covariance technique using the Doppler vertical velocity and attenuated backscatter. Building upon prior studies, we were able to relate backscatter to particle number concentration by calibrating the lidar retrievals against optical particle counter-measured ground-based aerosol size distribution and radiosonde-interpolated relative humidity at lidar sample height. Performing similar analysis was of interest to EPCAPE to better understand the emissions and vertical transport of large particles into the overlying stratus clouds. However, as stated above, this analysis requires an optical size distribution that covers the 0.3-30-μm-diameter size range. The OPC was deployed between 2023-04-14 and 2024-02-14. The deployment, data quality analysis, and data archiving was handled by the DOE ARM instrument mentor team without additional involvement by the principal investigator. Data quality was marked as “routine” for the majority of the campaign.

54 ENVIRONMENTAL SCIENCES↗

COMBLE Ice Nucleating Particle Measurements

These data list ice nucleating particle (INP) number concentrations active in the immersion freezing mode per large volumes of air collected using filters, sampled atop the AOS trailer, part of AMF1, sited at Nordmela Harbor, Andøya Island, Norway, from 01 December 2019 to 26 May 2020, as part of the Cold-air Outbreaks in the Marine Boundary Layer Experiment (COMBLE). Collections were made over periods of 6 to 74 hours (average 34 h and 42 m3 filtered), with periods tailored to integrate cold-air outbreaks or flanking periods of non-cold-air outbreak air. We used open-faced polycarbonate filters that were sampled at a height of 4 m AGL on the AOS trailer (6 m below its inlet), 6-8 m ASL and 30 m inland from the harbor wall, and near the other AMF measurements. Filters were stored and returned frozen to Colorado State University (CSU), where immersion freezing measurements over a range from 0 to typically -28°C were made using the CSU Ice Spectrometer (IS). This first entailed the removal of particles (agitation of filter in 0.1 µm filtered ultrapure water) from filters to create aliquot suspensions that were subdivided (and frozen) for subsequent analyses. One portion was used to obtain a basic temperature spectrum of INP number concentrations on the basis of the freezing of an array of smaller liquid aliquots during cooling, and relation of the frozen fraction to the total air volume sampled. A subset of other portions of the original suspension aliquots were heat treated (95°C for 20 min) to denature biological INPs (a reduction in concentrations reveals the proportion of all INPs that were likely of biological origin, such as microbial or proteinaceous) and digested in 10% H2O2 at 95°C under UV-B illumination to remove all organic carbon INPs; the residual is presumed to be inorganic (likely mineral) INPs. Other samples have been archived frozen for future potential testing of INP source compositions and aerosol chemical and biological source attribution.

54 ENVIRONMENTAL SCIENCES↗

An alpha particle measurement system using an energetic neutral helium beam in ITER (invited)

An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He{sup +} ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He{sup +} ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microphysical properties of atmospheric soot and organic particles: measurements, modeling, and impacts

Atmospheric soot and organic particles from fossil fuel combustion and biomass burning modify Earth’s climate through their interactions with solar radiation and through modifications of cloud properties by acting as cloud condensation nuclei and ice nucleating particles. Recent advancements in understanding their individual properties and microscopic composition have led to heightened interest in their microphysical properties. This review article provides an overview of current advanced microscopic measurements and offers insights into future avenues for studying microphysical properties of these particles. To quantify soot morphology and ageing, fractal dimension ( D f ) is a commonly employed quantitative metric which allows to characterize morphologies of soot aggregates and their modifications in relation to ageing factors like internal mixing state, core-shell structures, phase, and composition heterogeneity. Models have been developed to incorporate D f and mixing diversity metrics of aged soot particles, enabling quantitative assessment of their optical absorption and radiative forcing effects. The microphysical properties of soot and organic particles are complex and they are influenced by particle sources, ageing process, and meteorological conditions. Furthermore, soluble organic particles exhibit diverse forms and can engage in liquid–liquid phase separation with sulfate and nitrate components. Primary carbonaceous particles such as tar balls and soot warrant further attention due to their strong light absorbing properties, presence of toxic organic constituents, and small size, which can impact human health. Future research needs include both atmospheric measurements and modeling approaches, focusing on changes in the mixing structures of soot and organic particle ensembles, their effects on climate dynamics and human health.

54 ENVIRONMENTAL SCIENCES↗

Neutral particle measurements of fusion tritons in JET

A neutral particle analyzer [A.D. Izvozchikov et al., JET Report No. JET-R(91)-12, 1991] operating in the MeV energy range was used to measure the flux of neutralized d-d fusion tritons emitted from the hot-ion H-mode deuterium plasma heated by deuterium neutral beams. It was found that tritons in the energy range of 0.3-1.1 MeV were largely neutralized by the beam atoms and the beam halo atoms. This enabled us to find the localized energy distribution function of the fusion tritons in the central plasma region. Simulation of the triton energy distribution function shows that MeV ions in the JET hot-ion H-mode plasma behave classically.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MARCUS Ice Nucleating Particle Measurements (revised 7/2020)

These data list ice nucleating particle (INP) number concentrations active in the immersion freezing mode. Aerosol filters were collected during 4 voyages of the Aurora Australis vessel from 02 November 2017 to 22 March 2018, as part of the Measurements of Aerosols, Radiation and Clouds over the Southern Ocean (MARCUS) study. These voyages transected the Southern Ocean from Hobart, Tasmania to four Australian Antarctic Division stations, including three in Antarctica. Collections were made over alternating periods of 24 and 48 hours using open-faced polycarbonate filters that were approximately 18 m MSL, sited near the AOS trailer and other AMF measurements. The volume of air filtered ranged from 19000 to 38000 standard liters per filter sample. Filters were stored and returned frozen to Colorado State University (CSU), where immersion freezing measurements over a range from 0 to -28 degC were made using the CSU Ice Spectrometer (IS). Collected particles from each filter were resuspended in filtered, deionized water, and then dispensed into the IS and cooled to obtain cumulative INP temperature spectra. Aliquots of suspensions from selected samples were also heat treated (95 degC for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95 degC under UV-B for 20 min to remove all organic carbon INPs, prior to measurement using the IS.

54 ENVIRONMENTAL SCIENCES↗