Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Lensless Particle Image Velocimetry

The application of lensless imaging to particle image velocimetry (PIV) is demonstrated. Lensless PIV eliminates the need for imaging lenses to measure flow fields near a surface. Only the camera sensor, a thin mask, and computations are required to image particles in a flow field and to compute the velocity field. The small form factor could enable embedded sensors for near-wall measurements. Flow field measurements are obtained simultaneously for a lensless system and lens-based 2D PIV system, and several different reconstruction techniques are demonstrated. The reconstructed particle images and computed velocity fields compare well for both a uniform and shear flow. The potential for stereo and 3D volumetric PIV with a single camera sensor is demonstrated through different image reconstruction approaches.

Lensless imaging↗

Particle-Displacement Tracking In Particle-Image Velocimetry

Particle images processed rapidly and automatically into velocity-vector maps. This technique requires no processing of photographic plates, no tedious visual recognition and manual designation of large numbers of image features for subsequent processing, little or no interruption by technician and is order of magnitude faster than any of prior techniques.

Wernet, Mark P.↗

Particle image velocimetry

Particle imaging velocimetry, which is rapidly becoming an essential tool for the synoptic measurement of two dimensional velocity fields, is addressed. This rapid development is carried out by a growing number of fluid mechanics experimentalists who recognize the unique capabilities of the technique to measure velocity fields in both space and time, and is supported by the concomitant development and availability of microcomputer hardware and software. Various applications of the technique to map different flow regimes are described and illustrated. Hardware implementations of the technique which utilize both conventional photography for image acquisition as well as digital 'online' methods for integrated image acquisition and processing are discussed. Recommendations to further enhance the technique and make it possible to map the three velocity components in three dimensional flow regions are given.

Lourenco, L. M.↗

Turbulent Flow Field Measurements of Separate Flow Round and Chevron Nozzles with Pylon Interaction Using Particle Image Velocimetry

Particle Image Velocimetry (PIV) measurements for six separate flow bypass ratio five nozzle configurations have recently been obtained in the NASA Langley Jet Noise Laboratory. The six configurations include a baseline configuration with round core and fan nozzles, an eight-chevron core nozzle at two different clocking positions, and repeats of these configurations with a pylon included. One run condition representative of takeoff was investigated for all cases with the core nozzle pressure ratio set to 1.56 and the total temperature to 828 K. The fan nozzle pressure ratio was set to 1.75 with a total temperature of 350 K, and the freestream Mach number was M = 0.28. The unsteady flow field measurements provided by PIV complement recent computational, acoustic, and mean flow field studies performed at NASA Langley for the same nozzle configurations and run condition. The PIV baseline configuration measurements show good agreement with mean flow field data as well as existing PIV data acquired at NASA Glenn. Nonetheless, the baseline configuration turbulence profile indicates an asymmetric flow field, despite careful attention to concentricity. The presence of the pylon increases the upper shear layer turbulence levels while simultaneously decreasing the turbulence levels in the lower shear layer. In addition, a slightly shorter potential core length is observed with the addition of the pylon. Finally, comparisons of computational results with PIV measurements are favorable for mean flow, slightly over-predicted for Reynolds shear stress, and underpredicted for Reynolds normal stress components.

Doty, Michael J.↗

Planar particle/droplet size measurement technique using digital particle image velocimetry image data

A method for determining a mass flux of an entrained phase in a planar two-phase flow records images of particles in the two-phase flow. Respective sizes of the particles (the entrained phase) are determined as a function of a separation between spots identified on the particle images. Respective velocities of the particles are determined. The mass flux of the entrained phase is determined as a function of the size and velocity of the particles.

Wernet, Mark P.↗

Young's fringe particle image velocimetry in the presence of random particle motions

In the Young's fringe approach to particle image velocimetry, random particle motions cause loss of fringe visibility by decorrelating the coherent interexposure particle separations responsible for fringe formation. Since the visibility reduction is determined by the random motion through a Fourier transform relation analogous to the Van Cittert Zernike Theorem, it has been proposed that the random motion can be characterized statistically by analyzing fringe visibility distributions in the transform plane. This paper assesses the accuracy of such measurements. In particular, the effects of finite particle population and of correlated random motion are evaluated. The theory applies to diffusive motion, turbulence, and to random motion caused by mean velocity inhomogeneities.

Rubinstein, R.↗

Two-dimensional particle displacement tracking in particle imaging velocimetry

A new particle imaging velocimetry data acquisition and analysis system, which is an order of magnitude faster than any previously proposed system, has been constructed and tested. The new particle displacement tracking (PDT) system is an all electronic technique employing a video camera and a large memory buffer frame-grabber board. Using a simple encoding scheme, a time sequence of single exposure images is time-coded into a single image and then processed to track particle displacements and determine two-dimensional velocity vectors. Use of the PDT technique in a counterrotating vortex flow produced over 1100 velocity vectors in 110 s when processed on an 80386 PC.

Wernet, Mark P.↗

On the Use of Mahalanobis Distance in Particle Image Velocimetry Post-Processing

Particle Image Velocimetry (PIV) is a method of flow measurement that has become increasingly popular as an experimental tool. New technology has made high-speed and higher-dimension (stereoscopic, tomographic, etc) methods available to an ever-growing population of researchers. These advanced methods can provide significantly more data than traditional low-speed planar PIV, but these larger data sets also require more resources to process and store. A major time sink in the post-processing of large PIV data sets is the identification and rejection of “bad” or ”spurious” vectors that survive an initial processing step in commercial software, which attempts to identify spurious vectors on an image-by-image basis and not with respect to repeated trials. The Mahalanobis distance, an almost 100-year-old statistical function, was determined to be well suited for this task for its computational efficiency and higher-dimensional nature. This work includes a summary of the Mahalanobis distance and validation of its usefulness as a tool for outlier rejection in the post-processing of PIV data.

Experimental Methods↗

Particle Image Velocimetry Applications Using Fluorescent Dye-Doped Particles

Polystyrene latex sphere particles are widely used to seed flows for velocimetry techniques such as Particle Image Velocimetry (PIV) and Laser Doppler Velocimetry (LDV). These particles may be doped with fluorescent dyes such that signals spectrally shifted from the incident laser wavelength may be detected via Laser Induced Fluorescence (LIF). An attractive application of the LIF signal is achieving velocimetry in the presence of strong interference from laser scatter, opening up new research possibilities very near solid surfaces or at liquid/gas interfaces. Additionally, LIF signals can be used to tag different fluid streams to study mixing. While fluorescence-based PIV has been performed by many researchers for particles dispersed in water flows, the current work is among the first in applying the technique to micron-scale particles dispersed in a gas. A key requirement for such an application is addressing potential health hazards from fluorescent dyes; successful doping of Kiton Red 620 (KR620) has enabled the use of this relatively safe dye for fluorescence PIV for the first time. In this paper, basic applications proving the concept of PIV using the LIF signal from KR620-doped particles are exhibited for a free jet and a twophase flow apparatus. Results indicate that while the fluorescence PIV techniques are roughly 2 orders of magnitude weaker than Mie scattering, they provide a viable method for obtaining data in flow regions previously inaccessible via standard PIV. These techniques have the potential to also complement Mie scattering signals, for example in multi-stream and/or multi-phase experiments.

Petrosky, Brian J.↗

Particle image velocimetry for the surface tension driven convection experiment using a particle displacement tracking technique

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the USML-1 Spacelab mission planned for 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electronic, two-dimensional particle image velocimetry technique called particle displacement tracking (PDT) which uses a simple space domain particle tracking algorithm. The PDT system is successful in producing velocity vector fields from the raw video data. Application of the PDT technique to a sample data set yielded 1606 vectors in 30 seconds of processing time. A bottom viewing optical arrangement is used to image the illuminated plane, which causes keystone distortion in the final recorded image. A coordinate transformation was incorporated into the system software to correct this viewing angle distortion. PDT processing produced 1.8 percent false identifications, due to random particle locations. A highly successful routine for removing the false identifications was also incorporated, reducing the number of false identifications to 0.2 percent.

Wernet, Mark P.↗

Particle image velocimetry for the Surface Tension Driven Convection Experiment using a particle displacement tracking technique

The Surface Tension Driven Convection Experiment (STDCE) is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the USML-1 Spacelab mission planned for 1992. One of the components of data collected during the experiment is a video record of the flow field. This qualitative data is then quantified using an all electronic, two-dimensional particle image velocimetry technique called particle displacement tracking (PDT) which uses a simple space domain particle tracking algorithm. The PDT system is successful in producing velocity vector fields from the raw video data. Application of the PDT technique to a sample data set yielded 1606 vectors in 30 seconds of processing time. A bottom viewing optical arrangement is used to image the illuminated plane, which causes keystone distortion in the final recorded image. A coordinate transformation was incorporated into the system software to correct this viewing angle distortion. PDT processing produced 1.8 percent false identifications, due to random particle locations. A highly successful routine for removing the false identifications was also incorporated, reducing the number of false identifications to 0.2 percent.

Wernet, Mark P.↗

Application of Digital Particle Imaging Velocimetry to Turbomachinery

Digital Particle Imaging Velocimetry (DPIV) is a powerful measurement technique, which can be used as an alternative or complementary approach to Laser Doppler Velocimetry (LDV) in a wide range of research applications. The instantaneous planar velocity measurements obtained with PIV make it an attractive technique for use in the study of the complex flow fields encountered in turbomachinery. Many of the same issues encountered in the application of LDV to rotating machinery apply in the application of PIV. Techniques for optical access, light sheet delivery, CCD camera technology and particulate seeding are discussed. Results from the successful application of the PIV technique to both the blade passage region of a transonic axial compressor and the diffuser region of a high speed centrifugal compressor are presented. Both instantaneous and time-averaged flow fields were obtained. The 95% confidence intervals for the time-averaged velocity estimates were also determined. Results from the use of PIV to study surge in a centrifugal compressor are discussed. In addition, combined correlation/particle tracking results yielding super-resolution velocity measurements are presented.

Wernet, Mark P.↗

Time Resolved Particle Image Velocimetry in Nozzle Flow

Temporally resolved particle image velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows—a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered six nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centred along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space–time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Temporally Resolved Particle Image Velocimetry↗

Optical correlator method and apparatus for particle image velocimetry processing

Young's fringes are produced from a double exposure image of particles in a flowing fluid by passing laser light through the film and projecting the light onto a screen. A video camera receives the image from the screen and controls a spatial light modulator. The spatial modulator has a two dimensional array of cells the transmissiveness of which are controlled in relation to the brightness of the corresponding pixel of the video camera image of the screen. A collimated beam of laser light is passed through the spatial light modulator to produce a diffraction pattern which is focused onto another video camera, with the output of the camera being digitized and provided to a microcomputer. The diffraction pattern formed when the laser light is passed through the spatial light modulator and is focused to a point corresponds to the two dimensional Fourier transform of the Young's fringe pattern projected onto the screen. The data obtained fro This invention was made with U.S. Government support awarded by the Department of the Army (DOD) and NASA grand number(s): DOD #DAAL03-86-K0174 and NASA #NAG3-718. The U.S. Government has certain rights in this invention.

Farrell, Patrick V.↗

Particle Imaging Velocimetry Used in a Transonic Compressor Facility

Particle Imaging Velocimetry (PIV) is an optical technique whereby a pulsed laser sheet is used to illuminate particles entrained in a fluid across an extended planar cross section of a flow field. Electronic recording of the particle positions at two closely timed laser pulses permits the computation of the flow velocity. PIV captures the instantaneous flow field, permitting the study of unsteady flow phenomena. Mean flow statistics can be computed by acquiring several hundred images and averaging the results. The first-ever successful application of PIV to acquire measurements in a high-speed rotating turbomachinery blade row was completed in NASA Lewis Research Center's W-8 Single Stage Axial Compressor Facility. Measurements were acquired in a 20-in.-diameter transonic compressor rotor operating at 17,188 rpm. A custom-designed light-sheet generating probe was used to insert the high-energy, pulsed light-sheet illumination required for recording the unblurred images of particles entrained in the fluid. Measurements of the shock wave formed within the rotor blade passage and of unsteady structures within the blade wakes were acquired. These measurements provide insight into unsteady spatial structures in the flow field which cannot be measured with the more conventional laser anemometry technique. The PIV technique provides both instantaneous and average velocity data in a transonic compressor in an order of magnitude less time than required for other conventional optical diagnostic techniques.

Wernet, Mark P.↗

Application of optical correlation techniques to particle imaging

Pulsed laser sheet velocimetry yields noninstrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usuallay MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the particle image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗

Particle-Image Velocimeter Having Large Depth of Field

An instrument that functions mainly as a particle-image velocimeter provides data on the sizes and velocities of flying opaque particles. The instrument is being developed as a means of characterizing fluxes of wind-borne dust particles in the Martian atmosphere. The instrument could also adapted to terrestrial use in measuring sizes and velocities of opaque particles carried by natural winds and industrial gases. Examples of potential terrestrial applications include monitoring of airborne industrial pollutants and airborne particles in mine shafts. The design of this instrument reflects an observation, made in field research, that airborne dust particles derived from soil and rock are opaque enough to be observable by use of bright field illumination with high contrast for highly accurate measurements of sizes and shapes. The instrument includes a source of collimated light coupled to an afocal beam expander and an imaging array of photodetectors. When dust particles travel through the collimated beam, they cast shadows. The shadows are magnified by the beam expander and relayed to the array of photodetectors. Inasmuch as the images captured by the array are of dust-particle shadows rather of the particles themselves, the depth of field of the instrument can be large: the instrument has a depth of field of about 11 mm, which is larger than the depths of field of prior particle-image velocimeters. The instrument can resolve, and measure the sizes and velocities of, particles having sizes in the approximate range of 1 to 300 m. For slowly moving particles, data from two image frames are used to calculate velocities. For rapidly moving particles, image smear lengths from a single frame are used in conjunction with particle- size measurement data to determine velocities.

Bos, Brent↗