Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARALLEL PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Boron-lined parallel-plate Collar

This report presents boron-lined parallel plate technology features, experimental benchmarking of initial MCNP model, and parallel-plate UNCL collar optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cerenkov and cyclotron Cerenkov instabilities in a dielectric loaded parallel plate waveguide sheet electron beam system

A dielectric loaded parallel plate waveguide sheet electron beam system can be taken as a reliable model for the practical dielectric loaded rectangular waveguide sheet beam system that has a transverse cross section with a large width to height ratio. By using kinetic theory, the dispersion equations for Cerenkov and cyclotron Cerenkov instabilities in the parallel plate waveguide sheet beam system have been obtained rigorously. The dependences of the growth rate of both instabilities on the electric and structural parameters have also been investigated in detail through numerical calculations. It is worthwhile to point out that adopting an electron beam with transverse velocity can evidently improve the growth rate of Cerenkov instability, which seems like the case of cyclotron Cerenkov instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams

Purpose: The electron fluence inside a parallel-plate ionization chamber positioned in a water phantom and exposed to a clinical electron beam deviates from the unperturbed fluence in water in absence of the chamber. One reason for the fluence perturbation is the well-known “inscattering effect,” whose physical cause is the lack of electron scattering in the gas-filled cavity. Correction factors determined to correct for this effect have long been recommended. However, more recent Monte Carlo calculations have led to some doubt about the range of validity of these corrections. Therefore, the aim of the present study is to reanalyze the development of the fluence perturbation with depth and to review the function of the guard rings. Methods: Spatially resolved Monte Carlo simulations of the dose profiles within gas-filled cavities with various radii in clinical electron beams have been performed in order to determine the radial variation of the fluence perturbation in a coin-shaped cavity, to study the influences of the radius of the collecting electrode and of the width of the guard ring upon the indicated value of the ionization chamber formed by the cavity, and to investigate the development of the perturbation as a function of the depth in an electron-irradiated phantom. The simulations were performed for a primary electron energy of 6 MeV. Results: The Monte Carlo simulations clearly demonstrated a surprisingly large in- and outward electron transport across the lateral cavity boundary. This results in a strong influence of the depth-dependent development of the electron field in the surrounding medium upon the chamber reading. In the buildup region of the depth-dose curve, the in–out balance of the electron fluence is positive and shows the well-known dose oscillation near the cavity/water boundary. At the depth of the dose maximum the in–out balance is equilibrated, and in the falling part of the depth-dose curve it is negative, as shown here the first time. The influences of both the collecting electrode radius and the width of the guard ring are reflecting the deep radial penetration of the electron transport processes into the gas-filled cavities and the need for appropriate corrections of the chamber reading. New values for these corrections have been established in two forms, one converting the indicated value into the absorbed dose to water in the front plane of the chamber, the other converting it into the absorbed dose to water at the depth of the effective point of measurement of the chamber. In the Appendix, the in–out imbalance of electron transport across the lateral cavity boundary is demonstrated in the approximation of classical small-angle multiple scattering theory. Conclusions: The in–out electron transport imbalance at the lateral boundaries of parallel-plate chambers in electron beams has been studied with Monte Carlo simulation over a range of depth in water, and new correction factors, covering all depths and implementing the effective point of measurement concept, have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Casimir effect for parallel plates involving massless Majorana fermions at finite temperature

We study the Casimir effect for parallel plates with massless Majorana fermions obeying the bag boundary conditions at finite temperature. The thermal influence will modify the effect. It is found that the sign of the Casimir energy remains negative if the product of the plate distance and the temperature is larger than a special value, otherwise the energy will change to positive. The Casimir energy rises with the stronger thermal influence. We show that the attractive Casimir force between two parallel plates becomes greater with increasing temperature. In the case of the piston system involving the same Majorana fermions with the same boundary conditions, the attractive force on the piston will be weaker in higher-temperature surroundings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-448: On the Perturbation Factor P-cav of the Markus Parallel Plate Ion Chambers in Clinical Electron Beams, Monte Carlo Based Reintegration of An Historical Experiment

Purpose: All present dosimetry protocols recommend well-guarded parallel-plate ion chambers for electron dosimetry. For the guard-less Markus chamber an energy dependent fluence perturbation correction pcav is given. This perturbation correction was experimentally determined by van der Plaetsen by comparison of the read-out of a Markus and a NACP chamber, which was assumed to be “perturbation-free”. Aim of the present study is a Monte Carlo based reiteration of this experiment. Methods: Detailed models of four parallel-plate chambers (Roos, Markus, NACP and Advanced Markus) were designed using the Monte Carlo code EGSnrc and placed in a water phantom. For all chambers the dose to the active volume filled with low density water was calculated for 13 clinical electron spectra (E{sub 0}=6-21 MeV) at the depth of maximum and at the reference depth under reference conditions. In all cases the chamber's reference point was positioned at the depth of measurement. Moreover, the dose to water DW was calculated in a small water voxel positioned at the same depth. Results: The calculated dose ratio D{sub NACP}/D{sub Markus}, which according to van der Plaetsen reflects the fluence perturbation correction of the Markus chamber, deviates less from unity than the values given by van der Plaetsen's but exhibits a similar energy dependence. The same holds for the dose ratios of the other well guarded chambers. But, in comparison to water, the Markus chamber reveals the smallest overall perturbation correction which is nearly energy independent at both investigated depths. Conclusion: The simulations principally confirm the energy dependence of the dose ratio D{sub NACP}/D{sub Markus} as published by van der Plaetsen. But, as shown by our simulations of the ratio D{sub W}/D{sub Markus}, the conclusion drawn in all dosimetry protocols is questionable: in contrast to all well-guarded chambers the guard-less Markus chamber reveals the smallest overall perturbation correction and also the smallest energy dependence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the wall perturbation correction for a parallel-plate NACP-02 chamber in clinical electron beams

Purpose: In recent years, several Monte Carlo studies have been published concerning the perturbation corrections of a parallel-plate chamber in clinical electron beams. In these studies, a strong depth dependence of the relevant correction factors (p{sub wall} and p{sub cav}) for depth beyond the reference depth is recognized and it has been shown that the variation with depth is sensitive to the choice of the chamber's effective point of measurement. Recommendations concerning the positioning of parallel-plate ionization chambers in clinical electron beams are not the same for all current dosimetry protocols. The IAEA TRS-398 as well as the IPEM protocol and the German protocol DIN 6800-2 interpret the depth of measurement within the phantom as the water equivalent depth, i.e., the nonwater equivalence of the entrance window has to be accounted for by shifting the chamber by an amount {Delta}z. This positioning should ensure that the primary electrons traveling from the surface of the water phantom through the entrance window to the chamber's reference point sustain the same energy loss as the primary electrons in the undisturbed phantom. The objective of the present study is the determination of the shift {Delta}z for a NACP-02 chamber and the calculation of the resulting wall perturbation correction as a function of depth. Moreover, the contributions of the different chamber walls to the wall perturbation correction are identified. Methods: The dose and fluence within the NACP-02 chamber and a wall-less air cavity is calculated using the Monte Carlo code EGSnrc in a water phantom at different depths for different clinical electron beams. In order to determine the necessary shift to account for the nonwater equivalence of the entrance window, the chamber is shifted in steps {Delta}z around the depth of measurement. The optimal shift {Delta}z is determined from a comparison of the spectral fluence within the chamber and the bare cavity. The wall perturbation correction is calculated as the ratio between doses for the complete chamber and a wall-less air cavity. Results: The high energy part of the fluence spectra within the chamber strongly varies even with small chamber shifts, allowing the determination of {Delta}z within micrometers. For the NACP-02 chamber a shift {Delta}z=-0.058 cm results. This value is independent of the energy of the primary electrons as well as of the depth within the phantom and it is in good agreement with the value recommended in the German dosimetry protocol. Applying this shift, the calculated wall perturbation correction as a function of depth is varying less than 1% from zero up to the half value depth R{sub 50} for electron energies in the range of 6-21 MeV. The remaining depth dependence can mainly be attributed to the scatter properties of the entrance window. When neglecting the nonwater equivalence of the entrance window, the variation of p{sub wall} with depth is up to 10% and more, especially for low electron energies. Conclusions: The variation of the wall perturbation correction for the NACP-02 chamber in clinical electron beams strongly depends on the positioning of the chamber. Applying a shift {Delta}z=-0.058 cm toward the focus ensures that the primary electron spectrum within the chamber bears the largest resemblance to the fluence of a wall-less cavity. Hence, the influence of the chamber walls on the perturbation correction can be separated out and the residual variation of p{sub wall} with depth is minimized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-350: Effective Point of Measurement and Total Perturbation Correction P for Parallel-Plate Ion Chambers in High-Energy Photon Beams

Purpose: This paper aims to determine the effective point of measurement and the total perturbation correction p of parallel-plate chambers for clinical photon dosimetry. Methods: The effective point of measurement (EPOM) was calculated using the EGSnrc Monte Carlo code system with the EGSnrc user code egs- chamber. Depth dose curves of the ionization chambers were calculated in a water phantom for several high energy photon spectra (4, 6, 10, 15, 18 MV-X). Different normalization criterions (normalization to the maximum of the depth dose curve and normalization to the value in 10 cm depth) have been applied. The EPOM was determined by shifting the normalized depth dose curve of a small water voxel against the depth ionization curve until the disagreement (calculated by the root mean square deviation) reaches a minimum. In addition, the total perturbation correction p was calculated by the ratio of the dose to water and the product of the dose determined in the chamber and the water to air stopping power ratio. Results: The EPOM varied slightly depending on the chosen normalization criterion. For all chambers the necessary shift of the EPOM decreased linearly with increasing beam quality specifier TPR{sub 20/10}. For the Roos and NACP chamber, the results were positive suggesting that the chambers need to be shifted towards the focus. For the Markus chamber, the required shift was negative and for the Advanced Markus chamber partly negative and partly positive. The total perturbation correction p was almost independent of the depth. Only for regions below 1 cm the perturbation correction deviated significantly from unity. Conclusion: In the present study, the effective point of measurement and the total perturbation correction p was determined for four parallel-plate ionization chambers and five clinical relevant photon spectra. Applying the calculated EPOM, the residual perturbation correction p was mostly depth independent.

60 APPLIED LIFE SCIENCES↗

Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector

Purpose: This work presents the experimental extraction of the overall perturbation factor P{sub Q} in megavoltage electron beams for NACP-02 and Roos parallel-plate ionization chambers using a plastic scintillation detector (PSD). Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6, 12, and 18 MeV clinical electron beams. The authors also measured depth-dose curves using the NACP-02 and PTW Roos chambers. Results: The authors found that the perturbation factors for the NACP-02 and Roos chambers increased substantially with depth, especially for low-energy electron beams. The experimental results were in good agreement with the results of Monte Carlo simulations reported by other investigators. The authors also found that using an effective point of measurement (EPOM) placed inside the air cavity reduced the variation of perturbation factors with depth and that the optimal EPOM appears to be energy dependent. Conclusions: A PSD can be used to experimentally extract perturbation factors for ionization chambers. The dosimetry protocol recommendations indicating that the point of measurement be placed on the inside face of the front window appear to be incorrect for parallel-plate chambers and result in errors in the R{sub 50} of approximately 0.4 mm at 6 MeV, 1.0 mm at 12 MeV, and 1.2 mm at 18 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Analysis of 10” Parallel Plate Relief Device

All Cryomodule (CM) and Cryogenic Distribution System (CDS) relieving into Helium Low Pressure (LP) return header, which is connected to compressor suction so, helium can be preserved during small flow relieving event and recirculated to system. However, during worst case scenario, Helium LP header requires a parallel plate relief device to relieve excess pressure from header. To complete the CDS Warm piping header, a new design for a 10 parallel plate relief device is necessary to relieve outside of the tunnel into atmosphere.

Chicas, Kelly↗

Oscillation modes of direct current microdischarges with parallel-plate geometry

Two different oscillation modes in microdischarge with parallel-plate geometry have been observed: relaxation oscillations with frequency range between 1.23 and 2.1 kHz and free-running oscillations with 7 kHz frequency. The oscillation modes are induced by increasing power supply voltage or discharge current. For a given power supply voltage, there is a spontaneous transition from one to other oscillation mode and vice versa. Before the transition from relaxation to free-running oscillations, the spontaneous increase of oscillation frequency of relaxation oscillations form 1.3 kHz to 2.1 kHz is measured. Fourier transform spectra of relaxation oscillations reveal chaotic behavior of microdischarges. Volt-ampere (V-A) characteristics associated with relaxation oscillations describes periodical transition between low current, diffuse discharge, and normal glow. However, free-running oscillations appear in subnormal glow only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron beam guiding by grooved SiO{sub 2} parallel plates without energy loss

Using a pair of grooved SiO{sub 2} parallel plates, stably guided electron beams were obtained without energy loss at 800–2000 eV. This shows that the transmitted electrons are guided by a self-organized repulsive electric field, paving the way for a self-adaptive manipulation of electron beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preparation of magnetized nanodusty plasmas in a radio frequency-driven parallel-plate reactor

Nanodust is produced in an rf-driven push-pull parallel-plate reactor using argon with an acetylene admixture at 5–30 Pa. A scheme for the preparation of nanodust clouds with particle radii up to 400 nm for investigations in magnetized plasmas is proposed. The confinement that keeps the nanodust of different radii inside a moderately magnetized discharge (B ≤ 500 mT) is investigated by a comparison of 2d-Langmuir probe measurements in the dust-free plasma without and with a magnetic field and by the analysis of scattered light of nanodust clouds. It is shown that the dust cloud changes its shape when the dust density changes. This results in a reversed α-γ{sup ′} transition from a dense dust cloud with a central disk-like void to a dilute dust cloud with a toroidal void. When the dust density is further reduced, filaments are observed in the central part of the cloud, which were absent in the high-density phase. It is concluded that the dense nanodust cloud is able to suppress plasma filamentation in magnetized plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Poisson–Boltzmann solutions for charged parallel plates: When opposite charges repel

I present an exact solution of the Poisson–Boltzmann equation for two parallel plates and discuss the solution properties. I discuss in more detail plates with opposite charges: In this case, there are two critical separations, L c,1 < L c,2 . For separations less than L c,1 , the force between plates is repulsive. It switches to attractive at L c,1 , but with the electric potential having the same sign on both plates. For L > L c,2 , the force remains attractive, and the potential at the plates has the same sign as the charge on each plate. I also describe charge regulation, determined by pK a , and provide formulas for both the critical distance where oppositely charged plates repel and their charging process. Finally, the implications of these results for the nanoparticle assembly, as driven by electrostatic interactions, are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Parametric electroconvection in a weakly conducting fluid in a horizontal parallel-plate capacitor

We study the flows of a nonuniformly heated weakly conducting fluid in an ac electric field of a horizontal parallel-plate capacitor. Analysis is carried out for fluids in which the charge formation is governed by electroconductive mechanism associated with the temperature dependence of the electrical conductivity of the medium. Periodic and chaotic regimes of fluid flow are investigated in the limiting case of instantaneous charge relaxation and for a finite relaxation time. Bifurcation diagrams and electroconvective regimes charts are constructed. The regions where fluid oscillations synchronize with the frequency of the external field are determined. Hysteretic transitions between electroconvection regimes are studied. The scenarios of transition to chaotic oscillations are analyzed. Depending on the natural frequency of electroconvective system and the external field frequency, the transition from periodic to chaotic oscillations can occur via quasiperiodicity, a subharmonic cascade, or intermittence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of azimuthally asymmetric reactor components on a parallel plate capacitively coupled plasma

A three-dimensional fluid plasma model is used to investigate the impact of azimuthally asymmetric reactor components on spatial characteristics of parallel plate capacitively coupled plasmas. We consider three scenarios: high frequency (13.56 MHz) argon discharges with, separately, an off-axis circular plate surrounding the bottom electrode and an access port opening in the reactor sidewall, and a very high frequency (162 MHz) argon discharge with nonparallel electrodes. For the reactor with off-axis plate, both the Ar{sup +} density and flux are strongly perturbed toward the direction of maximum grounded surface area, with azimuthal variation in ion flux up to 10%. Perturbations in Ar{sup +} density due to the access port opening are localized to the region near the access port, and the impact on ion flux in the interelectrode region is minimal. Finally, the nonparallel electrodes result in a significant change in the location and shape of the Ar{sup +} density profile, going from a center-peaked discharge with parallel electrodes to a flattened off-center profile when tilted less than 1 deg. with a nominal 5 cm gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗