Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “P-V”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Telescope Wavefront Aberration Compensation with a Deformable Mirror in an Adaptive Optics System

With the goal of reducing the surface wavefront error of low-cost multi-meter-diameter mirrors from about 10 waves peak-to-valley (P-V), at lpm wavelength, to approximately 1-wave or less, we describe a method to compensate for slowly varying wavefront aberrations of telescope mirrors. A deformable mirror is utilized in an active optical compensation system. The kMS wavefront error of a 0.3m telescope improved to 0.05 waves (0.26 waves P-V) from the original value of 1.4 waves RMS (6.5 waves P-V), measured at 633nm, and the Strehl ratio improved to 89% from the original value of 0.08%.

active optics↗

Poster Presentation: Optical Test of NGST Developmental Mirrors

An Optical Testing System (OTS) has been developed to measure the figure and radius of curvature of NGST developmental mirrors in the vacuum, cryogenic environment of the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The OTS consists of a WaveScope Shack-Hartmann sensor from Adaptive Optics Associates as the main instrument, a Point Diffraction Interferometer (PDI), a Point Spread Function (PSF) imager, an alignment system, a Leica Disto Pro distance measurement instrument, and a laser source palette (632.8 nm wavelength) that is fiber-coupled to the sensor instruments. All of the instruments except the laser source palette are located on a single breadboard known as the Wavefront Sensor Pallet (WSP). The WSP is located on top of a 5-DOF motion system located at the center of curvature of the test mirror. Two PC's are used to control the OTS. The error in the figure measurement is dominated by the WaveScope's measurement error. An analysis using the absolute wavefront gradient error of 1/50 wave P-V (at 0.6328 microns) provided by the manufacturer leads to a total surface figure measurement error of approximately 1/100 wave rms. This easily meets the requirement of 1/10 wave P-V. The error in radius of curvature is dominated by the Leica's absolute measurement error of VI.5 mm and the focus setting error of Vi.4 mm, giving an overall error of V2 mm. The OTS is currently being used to test the NGST Mirror System Demonstrators (NMSD's) and the Subscale Beryllium Mirror Demonstrator (SBNM).

Hadaway, James B.↗

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

NASA Discipline Cardiopulmonary↗

Cardiac atrophy after bed-rest deconditioning: a nonneural mechanism for orthostatic intolerance

BACKGROUND: The cardiovascular adaptation to bed rest leads to orthostatic intolerance, characterized by an excessive fall in stroke volume (SV) in the upright position. We hypothesized that this large fall in SV is due to a change in cardiac mechanics. METHODS AND RESULTS: We measured pulmonary capillary wedge pressure (PCWP), SV, left ventricular end-diastolic volume (LVEDV), and left ventricular mass (by echocardiography) at rest, during lower-body negative pressure, and after saline infusion before and after 2 weeks of bed rest with -6 degrees head-down tilt (n=12 subjects aged 24+/-5 years). Pressure (P)-volume (V) curves were modeled exponentially by P=ae(kV)+b and logarithmically by P=-Sln[(Vm-V)/(Vm-V0)], where V0 indicates volume at P=0, and the constants k and S were used as indices of normalized chamber stiffness. Dynamic stiffness (dP/dV) was calculated at baseline LVEDV. The slope of the line relating SV to PCWP during lower-body negative pressure characterized the steepness of the Starling curve. We also measured plasma volume (with Evans blue dye) and maximal orthostatic tolerance. Bed rest led to a reduction in plasma volume (17%), baseline PCWP (18%), SV (12%), LVEDV (16%), V0 (33%), and orthostatic tolerance (24%) (all P<.05). The slope of the SV/PCWP curve increased from 4.6+/-0.4 to 8.8+/-0.9 mL/mm Hg (P<.01) owing to a parallel leftward shift in the P-V curve. Normalized chamber stiffness was unchanged, but dP/dV was reduced by 50% at baseline LVEDV, and cardiac mass tended to be reduced by 5% (P<.10). CONCLUSIONS: Two weeks of head-down-tilt bed rest leads to a smaller, less distensible left ventricle but a shift to a more compliant portion of the P-V curve. This results in a steeper Starling relationship, which contributes to orthostatic intolerance by causing an excessive reduction in SV during orthostasis.

NASA Discipline Cardiopulmonary↗

Properties of planetary fluids at high pressure and temperature

In order to derive models of the interiors of Uranus, Neptune, Jupiter and Saturn, researchers studied equations of state and electrical conductivities of molecules at high dynamic pressures and temperatures. Results are given for shock temperature measurements of N2 and CH4. Temperature data allowed demonstration of shock induced cooling in the the transition region and the existence of crossing isotherms in P-V space.

Nellis, W. J.↗

High-pressure phase transition and equation of state of CsI

Stuructural properties of CsI at high pressure have been investigated by the use of synchrotron X-ray-diffraction techniques with the diamond-anvil cell at 300 K. The results indicate that the material undergoes a continuous distortion from B2 to an hcp-like phase, which is stable to at least 302 GPa. The intermediate orthorhombic phase is geometrically different from previous assignments and about 10 percent denser. With the new structure, the p-V results of static pressure experiments, shock-wave studies, and theoretical calculations are now in good agreement.

Mao, H. K.↗

The analysis of high pressure experimental data

This letter is concerned with the analysis of high pressure experimental data. It is demonstrated that ln H plots based on the Vinet et al. (1988) universal equation of state are a simple sensitive means for identifying anomalous P-V data in high pressure experiments and for detecting structural and phase transitions in solids subjected to high pressure.

Schlosser, Herbert↗

Compensation for 6.5 K cryogenic distortion of a fused quartz mirror by refiguring

A 46 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single-arch cross section was tested at the NASA-Ames Research Center Cryogenic Optical Test Facility to measure its cryogenic distortion at 6.5 K. Then the mirror was refigured with the inverse of the measured cryogenic distortion to compensate for this figure defect. The mirror was retested at 6.5 K and found to have a significantly improved figure. The compensation for cryogenic distortion was not complete, but preliminary analysis indicates that the compensation was better than 0.25 waves P-V if edge effects are ignored. The feasibility of compensating for cryogenic distortion by refiguring has thus been verified.

Augason, Gordon C.↗

SiC lightweight telescopes for advanced space applications. I - Mirror technology

A SiC based telescope is an extremely attractive emerging technology which offers the lightweight and stiffness features of beryllium, the optical performance of glass to diffraction limited visible resolution, superior optical/thermal stability to cryogenic temperatures, and the cost advantages of an aluminum telescope. SSG has developed various SiC mirrors with and without a silicon coating and tested these mirrors over temperature ranges from +50 C to -250 C. Our test results show less than 0.2 waves P-V in visible wavefront change and no hysteresis over this wide temperature range. Several SSG mirrors are representative of very lightweight SiC/Si mirrors including (1) a 9 cm diameter, high aspect ratio mirror weighing less than 30 grams and (2) a 23 cm diameter eggcrated mirror weighing less than 400 grams. SSG has also designed and analyzed a 0.6 meter SiC based, on axis, three mirror reimaging telescope in which the primary mirror weighs less than 6 kg and a 0.5 meter GOES-like scan mirror. SSG has also diamond turned several general aspheric SiC/Si mirrors with excellent cryo optical performance.

Anapol, Michael I.↗

SiC lightweight telescopes for advanced space applications. II - Structures technology

A critical technology area for lightweight SiC-based telescope systems is the structural integrity and thermal stability over spaceborne environmental launch and thermal operating conditions. Note, it is highly desirable to have an inherently athermal design of both SiC mirrors and structure. SSG has developed an 8 inch diameter SiC telescope system for brassboard level optical and thermal testing. The brassboard telescope has demonstrated less than 0.2 waves P-V in the visible wavefront change over +50 C to -200 C temperature range. SSG has also fabricated a SiC truss structural assembly and successfully qualified this hardware at environmental levels greater than 3 times higher than normal Delta, Titan, and ARIES launch loads. SSG is currently developing two SiC telescopes; an 20 cm diameter off-axis 3 mirror re-imaging and a 60 cm aperture on-axis 3 mirror re-imager. Both hardware developments will be tested to flight level environmental, optical, and thermal specifications.

Anapol, Michael I.↗

Investigations into mirror fabrication metrology analysis

This final report describes the work performed under this delivery order from June 1993 through August 1994. The scope of work included three distinct tasks in support of the AXAF-I program. The objective of the first task was to perform investigations of the grinding and polishing characteristics of the zerodur material by fabricating several samples. The second task was to continue the development of the integrated optical performance modeling software for AXAF-I. The purpose of third and final task was to develop and update the database of AXAF technical documents for an easy and rapid access. The MSFC optical and metrology shops were relocated from the B-wing of Building 4487 to Room BC 144 of Building 4466 in the beginning of this contract. This included dismantling, packing, and moving the equipment from its old location, and then reassembling it at the new location. A total of 65 zerodur samples, measuring 1 inch x 2 inches x 6 inches were ground and polished to a surface figure of lambda/10 p-v, and a surface finish of 5A rms were fabricated for coating tests. A number of special purpose tools and metal mirrors were also fabricated to support various AXAF-I development activities. In the metrology area, the ZYGO Mark 4 interferometer was relocated and also upgraded with a faster and more powerful processor. Surface metrology work was also performed on the coating samples and other optics using ZYGO interferometer and WYKO profilometer. A number of new features have been added to the GRAZTRACE program to enhance its analysis and modeling capabilities. A number of new commands have been added to the command mode GRAZTRACE program to provide a better control to the user on the program execution and data manipulation. Some commands and parameter entries have been reorganized for a uniform format. The command mode version of the convolution program CONVOLVE has been developed. An on-line help system and a user's manual have also been developed for the benefit of the users. The database of AXAF technical documents continues to progress. The titles, company name, date, and location of over 390 documents have been entered in this database. This database provides both a data search and retrieval function, and a data adding function. These functions allow a user to quickly search the data files for documents or add new information. A detailed user's guide has also been prepared. This user guide includes a document classification guide, a list of abbreviations, and a list of acronyms, which have been used in compiling this database of AXAF-I technical documents.

Dimmock, John O.↗

Static-thrust Investigation of Full-scale PV-2 Helicopter Rotors Having NACA 0012.6 and 23012.6 Airfoil Sections

An investigation was conducted to compare the performance of two 25-ft-diam rotors which had identical dimensions and were similar in construction but different in blade airfoil-sections. Tests were conducted at indicated blade pitch angles from 3 degrees to 11.5 degrees and rotor speeds of 200, 290, and 371 rpm. The 23012.6 rotor required 2 percent less power to hover than the 0012.6. At thrust coefficients above design, the performance of the 23012.6 became better than the 0012.6 rotor.

PROPELLERS, HELICOPTER - P-V ENG FORUM 2↗