Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Optical position sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition

Designed 2D protein crystals as dynamic molecular gatekeepers for a solid-state device

The sensitivity and responsiveness of living cells to environmental changes are enabled by dynamic protein structures, inspiring efforts to construct artificial supramolecular protein assemblies. However, despite their sophisticated structures, designed protein assemblies have yet to be incorporated into macroscale devices for real-life applications. We report a 2D crystalline protein assembly of C98/E57/E66 L-rhamnulose-1-phosphate aldolase ( CEE RhuA) that selectively blocks or passes molecular species when exposed to a chemical trigger. CEE RhuA crystals are engineered via cobalt(II) coordination bonds to undergo a coherent conformational change from a closed state (pore dimensions <1 nm) to an ajar state (pore dimensions ~4 nm) when exposed to an HCN(g) trigger. When layered onto a mesoporous silicon (pSi) photonic crystal optical sensor configured to detect HCN (g) , the 2D CEE RhuA crystal layer effectively blocks interferents that would otherwise result in a false positive signal. The 2D CEE RhuA crystal layer opens in selective response to low-ppm levels of HCN (g) , allowing analyte penetration into the pSi sensor layer for detection. These findings illustrate that designed protein assemblies can function as dynamic components of solid-state devices in non-aqueous environments.

36 MATERIALS SCIENCE

Versatile & Intelligent Biodetection via Environmental Sensing (VIBES)

Reactive health monitoring strategies during events like the COVID-19 pandemic highlighted the need for predictive, threat-agnostic diagnostics that can detect both known diseases and novel chemical or biological threats. To address this, we investigated an optical biosensor as a breath volatile organic compound (VOC) analyzer, aiming to emulate biological olfaction. We assembled and validated the device with thin film metal coated substrate-based sensors. We immobilized small biological recognition elements on the substrates and delivered controlled concentrations of target VOCs. The sensor was irradiated with a visible laser and the sensor signal was recorded. We characterized the laser performance and tested 3 recognition elements for 2 VOCs with varying concentrations (1-100 ppm). We also evaluated enhancement of the signal using nanostructures on the metal film in comparison with planar film substrate. We demonstrated detecting ethanol reliably at concentrations as low as ~2 ppm along with preliminary detection of acetone (<100 ppm). We also found several unexpected factors that influence the sensor behavior that should be addressed to further refine the device’s performance. The nanostructures were, as expected, found to amplify the sensor signals. These findings demonstrate the feasibility of the optical bio-sensing modality for breath VOC monitoring at physiologically relevant levels. This positions LLNL to develop a low-cost, scalable, broad-spectrum health monitoring capability aligned with the Early Detection thrust of the Bioresilience Mission Focus Area and attract external funding.

47 OTHER INSTRUMENTATION

MOSAIC-CONUS: A Multimodal, Multi-Temporally Paired Dataset for Earth Sciences

Earth embeddings—vector representations of geographic locations indexed in space and time—are emerging as a unifying interface for geospatial AI. However, their quality depends not only on model design, but on how multimodal Earth observation (EO) data are spatially indexed, temporally aligned, and cross-modally associated during pretraining. We introduce MOSAIC-CONUS (Multimodal Observations with Spatially Aligned Imagery, Urban Points of Interest, In-Situ Measurements and Text Captions), a large-scale EO dataset over the contiguous United States, organized around 250,000 stratified point indices that serve as stable spatial keys across seven modalities: active radar, passive optical imagery, lidar-derived elevation, land cover, functional context, hydrometeorological measurements, and textual summaries. Unlike existing EO datasets, MOSAIC-CONUS introduces four contributions not jointly addressed in prior work: 1. an open-source, large-scale multimodal EO corpus structured around point-indexed data designed to support Earth embedding learning; 2. explicit radar-optical pairing tables spanning twelve temporal alignment regimes, formalizing cross-sensor alignment as a controllable variable for analyzing how temporal mismatch across modalities influences learned embeddings quality; 3. a benchmark suite spanning cross-modal retrieval, annual nightlights regression, and basin-held-out streamflow prediction, positioning MOSAIC-CONUS as a benchmark-ready resource for multimodal AI systems; and 4. a language-based embedding layer through co-registered textual summaries, enabling Earth embeddings to function as a queryable interface for agentic AI systems. The dataset and pairing protocols are publicly released.

54 ENVIRONMENTAL SCIENCES

A dedicated mirror-magnet experiment to study quench characteristics and dependencies in $Nb_{3}Sn$ coils and explore improvements of diagnostics capabilities

A single Nb3Sn short quadrupole coil in a mirror-magnet configuration was employed to investigate a wide range of phenomena and to serve as test-bed for diagnostics developments. A configurable array of spot-heaters was installed on the inner coil surface for control of induced quench conditions. Several different quench antenna arrays were positioned along the coil inner surface, and included significant sensor overlap for assessment of their relative efficiency and operation. Multiple acoustic sensors were placed on the pole and at coil ends. Optical fibers in grid configurations were put in different places on the coil and magnet for strain assessment, along with standard resistive strain gauges. Current spikes in the magnet circuit were monitored. This plethora of instrumentation aimed to support investigations on induced and spontaneous quenches, among other goals, and was supplemented by standard voltage-tap-based measurements. Voltage tap data of induced quenches from various spot-heater configurations was investigated for similarities to voltage development in spontaneous quenches. Quench antennas provided insights about current redistribution in the quenching coil and coil splices. The Quench Current-boosting Device was applied and the effect on coil training examined. This paper describes motivations behind the research, the overall test setup and main results.

Stoynev, Stoyan [Fermilab]

Swept-Lookback Deflectometry for High Performance Concentrating Solar Power Optical Metrology

This report describes an initial investigation into a proposed solution to the important problem of performing a detailed evaluation of heliostat optical performance, in situ in a heliostat field. Our approach is to place digital cameras in a position near the receiver where they look back toward the heliostat mirrors. The pixels of each camera sensor identify a set of small cells on the mirror surface, each corresponding to a “mixel.” By either passing reflected sunbeam over the camera or passing the camera through the reflected sunbeam, the cameras intercept sunlight reflected from each mixel. We then analyze the recorded video data to determine times when each mixel transitions from dark to light, and then back to dark. We then use these transitions to construct vectors from the camera to the mixel, and then from the mixel to the edge of the Sun at that moment. We then compute the surface normal at the mixel, which bisects the angle between these vectors. Performing this analysis for all mixels in the mirror yields a high-resolution map of slope across the mirror surface. We have implemented most of this process, successfully collecting data for an example heliostat facet and computing a preliminary estimated slope map. However, more work remains to complete this calculation, since certain factors and transformations are not yet included. Our observations so far support our hypothesis that such a system is possible, but we have not yet completed our quantitative evaluation of the concept.

14 SOLAR ENERGY

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Window obscuration sensors for mobile gas and chemical imaging cameras

An infrared (IR) imaging system for determining a concentration of a target species in an object is disclosed. The imaging system can include an optical system including a focal plane array (FPA) unit behind an optical window. The optical system can have components defining at least two optical channels thereof, said at least two optical channels being spatially and spectrally different from one another. Each of the at least two optical channels can be positioned to transfer IR radiation incident on the optical system towards the optical FPA. The system can include a processing unit containing a processor that can be configured to acquire multispectral optical data representing said target species from the IR radiation received at the optical FPA. One or more of the optical channels may be used in detecting objects on or near the optical window, to avoid false detections of said target species.

Mallery, Ryan

Incubating advances in integrated photonics with emerging sensing and computational capabilities

As photonic technologies grow in multidimensional aspects, integrated photonics holds a unique position and continuously presents enormous possibilities for research communities. Applications include data centers, environmental monitoring, medical diagnosis, and highly compact communication components, with further possibilities continuously growing. Herein, we review state-of-the-art integrated photonic on-chip sensors that operate in the visible to mid-infrared wavelength region on various material platforms. Among the different materials, architectures, and technologies leading the way for on-chip sensors, we discuss the optical sensing principles that are commonly applied to biochemical and gas sensing. Our focus is on passive optical waveguides, including dispersion-engineered metamaterial-based structures, which are essential for enhancing the interaction between light and analytes in chip-scale sensors. We harness a diverse array of cutting-edge sensing technologies, heralding a revolutionary on-chip sensing paradigm. Our arsenal includes refractive-index-based sensing, plasmonics, and spectroscopy, which forge an unparalleled foundation for innovation and precision. Furthermore, we include a brief discussion of recent trends and computational concepts, incorporating Artificial Intelligence & Machine Learning (AI/ML) and deep learning approaches over the past few years to improve the qualitative and quantitative analysis of sensor measurements.

Jain, Sourabh (ORCID:0000000279923275)

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Performance of cross-flow turbines with varying blade materials and unsupported blade span

Cross-flow turbines could play a larger role in the diversification of the global energy supply if the impact of more cost-competitive design choices on performance and rotor dynamics was better understood. This study focuses on rotor performance and blade strain measurements while varying the following parameters: blade materials and blade free end length by changing strut support position. Towing tank experiments were performed with a modular 1-meter diameter cross-flow turbine consisting of three NACA 0018 blades with two support struts. One strut was fixed at the lower end of the turbine, while the second strut was adjustable, thereby changing the length of the free end. The blade materials tested were carbon, E-glass, and hollow E-glass fiber composites, in decreasing order of stiffness and cost. High-resolution distributed fiber optic sensors were embedded in two of the three rotor blades for each material and provided hundreds of strain measurements per blade. Turbine performance and blade strain were measured while varying tow speed and tip speed ratio. Performance tests were conducted at towing speeds sufficiently high for the performance to be independent of Reynolds number. E-glass blades and carbon blades performed similarly for the most rigid strut configurations. Higher strain was measured on the E-glass blades, and their performance was reduced for less rigid configurations compared to the carbon fiber blades. The performance of the highly deflective hollow E-glass blades was lower overall and became even more degraded for longer unsupported blade span. Furthermore, the results provide insight into the use of various blade materials in cross-flow turbines and guidance on allowable free end length for each material type.

16 TIDAL AND WAVE POWER

Spin squeezing in an ensemble of nitrogen–vacancy centres in diamond

Spin-squeezed states provide a seminal example of how the structure of quantum mechanical correlations can be controlled to produce metrologically useful entanglement. These squeezed states have been demonstrated in a wide variety of quantum systems ranging from atoms in optical cavities to trapped ion crystals. By contrast, despite their numerous advantages as practical sensors, spin ensembles in solid-state materials have yet to be controlled with sufficient precision to generate targeted entanglement such as spin squeezing. Here we report the experimental demonstration of spin squeezing in a solid-state spin system. Our experiments are performed on a strongly interacting ensemble of nitrogen–vacancy colour centres in diamond at room temperature, and squeezing (−0.50 ± 0.13 dB) below the noise of uncorrelated spins is generated by the native magnetic dipole–dipole interaction between nitrogen–vacancy centres. To generate and detect squeezing in a solid-state spin system, we overcome several challenges. First, we develop an approach, using interaction-enabled noise spectroscopy, to characterize the quantum projection noise in our system without directly resolving the spin probability distribution. Second, noting that the random positioning of spin defects severely limits the generation of spin squeezing, we implement a pair of strategies aimed at isolating the dynamics of a relatively ordered sub-ensemble of nitrogen–vacancy centres. Furthermore, our results open the door to entanglement-enhanced metrology using macroscopic ensembles of optically active spins in solids.

Atomic and molecular physics

Experimental Investigation of Low-Frequency Distributed Acoustic Sensor Responses to Two Parallel Propagating Fractures

Low-frequency distributed acoustic sensing (LF-DAS) is a diagnostic tool for hydraulic fracture propagation with far-field monitoring using fiber optic sensors. LF-DAS senses strain rate variation caused by stress field change due to fracture propagation. Fiber optic sensors are installed in the monitoring wells in the vicinity of a fractured well. From the strain responses, fracture propagation can be evaluated. To understand subsurface conditions with multiple propagating fractures, a laboratory-scale hydraulic fracture experiment was performed simulating the LF-DAS response to fracture propagation with embedded distributed optical fiber strain sensors under these conditions. The experiment was performed using a transparent cube of epoxy with two parallel radial initial flaws centered in the cube. Fluid was injected into the sample to generate fractures along the initial flaws. The experiment used distributed high-definition fiber optic strain sensors with tight spatial resolutions. The sensors were embedded at two different locations on opposite sides of the initial flaws, serving as observation/monitoring locations. We also employed finite element modeling to numerically solve the linear elastic equations of equilibrium continuity and stress–strain relationships. The measured strains from the experiment were compared to simulation results from the finite element model. The experimentally derived strain and strain-rate waterfall plots from this study show the responses to both fractures propagating, while the fracture at the lower position took most of the fluid during the experiment. Interestingly, a fracture first began propagating from the upper flaw of the two flaws, but once the lower fracture was initiated, it grew much faster than the upper fracture. Both fibers were intercepted by the lower fracture, further verifying the strain signature as a fracture is approaching and intersecting an offset fiber.

Chemistry

Light-powered end-to-end neutron detection and imaging with an edge-deployed optical AI chip

Neutron detection is widely used in many applications including nuclear physics, nuclear energy, nuclear technologies and nuclear safeguards. Developing an end-to-end neutron detection and imaging workflow paves way towards fully automated processes for many applications. We implemented an automated workflow for neutron detection experiments which use a solid state image sensor to capture neutron hits as a digital image. We deploy the workflow to an edge-based optical neural network (ONN) to increase the radiation-hardness and lifetime of neutron detection instruments. We present a two-stage neural network framework for detection of neutrons at sub-pixel resolution. The first stage uses a region proposal network to efficiently detect and extract neutron hits from the input camera image. The second stage feeds the extracted hits into a fully connected neural network to predict the sub-pixel hit position. The performance of the two-stage framework is evaluated using the edge-based ONN. The results show that we can achieve above 96% neutron detection accuracy as well as sub-pixel and sub-micron position resolution, while enjoying the advantages of the ONN hardware including radiation-hardness, low energy consumption and high computing speed for integrated edge camera and hardware deployment, when compared with electronic counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Molecularly Imprinted Polymer Sensor Empowered by Bound States in the Continuum for Selective Trace-Detection of TGF-beta

The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.

77 NANOSCIENCE AND NANOTECHNOLOGY

Technical note: Recommendations for diagnosing cloud feedbacks and rapid cloud adjustments using cloud radiative kernels

Abstract. The cloud radiative kernel method is a popular approach to quantify cloud feedbacks and rapid cloud adjustments to increased CO2 concentrations and to partition contributions from changes in cloud amount, altitude, and optical depth. However, because this method relies on cloud property histograms derived from passive satellite sensors or produced by passive satellite simulators in models, changes in obscuration of lower-level clouds by upper-level clouds can cause apparent low-cloud feedbacks and adjustments, even in the absence of changes in lower-level cloud properties. Here, we provide a methodology for properly diagnosing the impact of changing obscuration on cloud feedbacks and adjustments and quantify these effects across climate models. Averaged globally and across global climate models, properly accounting for obscuration leads to weaker positive feedbacks from lower-level clouds and stronger positive feedbacks from upper-level clouds while simultaneously removing a mostly artificial anti-correlation between them. Given that the methodology for diagnosing cloud feedbacks and adjustments using cloud radiative kernels has evolved over several papers, and obscuration effects have only occasionally been considered in recent papers, this paper serves to establish recommended best practices and to provide a corresponding code base for community use.

54 ENVIRONMENTAL SCIENCES

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND