Plasma spectroscopy using the shock tube as a light source
High temperature plasmas optical properties measurement by plasma spectroscopy, using gas driven shock tube as light source
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High temperature plasmas optical properties measurement by plasma spectroscopy, using gas driven shock tube as light source
Optical emission measurements provided information on the spatial distribution of energetic (primary and suprathermal) electrons producing the emissions; power dissipation during beam transit of the system; and modifications of the primary beam velocity distribution. The measurements were carried out for BPD's produced in a very large vacuum chamber using a 391.4 nm scanning photometer and total light (red sensitive) TV systems. Results for conditions Eb 500 to 2000 V, injection pitch angle 0 to 75 deg, and neutral density are presented. The typical power loss in ionization in transit of the 20 m pathlength during BPD is from 3 to 10% of the input power, an order of magnitude greater than attributable to collisional ionization alone. Differences between rocket observations and the laboratory results are noted.
Absolute emissivities of uranium plasmas in gas driven shock tube
An inductively coupled GEC Cell with modified viewing ports has been used to measure in-situ absorption in CF4 plasmas via Fourier Transform Infrared Spectroscopy, and the results compared to those obtained in a standard viewport configuration. The viewing ports were modified so that the window boundary is inside, rather than outside, of the GEC cell. Because the absorption obtained is a spatially integrated absorption, measurements made represent an averaging of absorbing species inside and outside of the plasma. This modification is made to reduce this spatial averaging and thus allow a more accurate estimation of neutral species concentrations and temperatures within the plasmas. By reducing this pathlength, we find that the apparent CF4 consumption increases from 65% to 95% and the apparent vibrational temperature of CF4 rises by 50-75 K. The apparent fraction of etch product SiF4 decreases from 4% to 2%. The data suggests that these density changes may be due to significant temperature gradients between the plasma and chamber viewports.
A plasma model, previously developed to interpret neutral-particle analyzer measurements on E x B heating devices, is adapted to analyze Doppler broadened charge-exchange-neutral lines measured by an optical monochromator. Comparison of theoretical with experimental results indicates that azimuthal drift as well as cyclotron motion are quite influential in determining line shapes and widths, and thus important in temperature determination, even when the monochromator line of sight is intersecting the plasma axis of symmetry. At this central sighting position, however, results are quite insensitive to radial ion density distribution when time lag between the charge-exchange-excitation events and emission is neglected. Line shapes and widths obtained by sighting across chords of plasma at various distances from the plasma axis of symmetry indicate a strong dependence on time lag.
A power meter was constructed to measure the power being deposited in transient laser-induced plasmas (LIP). The design rejects the radiation scattered from the laser beam by the LIP and that transmitted past the LIP. The power meter is constructed from a small metal-capped flask placed in an evacuated chamber. The steady-state heat production in the flask is determined from measurements of the temperature gradient on a thermal resistance connecting the top of the flask with a heat sink. The design worked well and should be applicable to a wide variety of situations if the dimensions of the system are adjusted to compensate for power levels substantially different from those used here.
Optical heterodyne system used to measure electron density of plasma
Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.
The data set consists of a selected number of passes, each comprising a format combination that is most appropriate for the particular data set. A list of ISIS 2 experimenters, with addresses and telephone numbers is included. A brief description of the ISIS 2 satellite is given, followed by more detailed instrument descriptions, format descriptions, data set descriptions, and the data themselves.
The Mars Spark Source Prototype (MSSP) hardware was developed as part of a proof of concept system for the detection of trace metals such as lead, cadmium, and arsenic in Martian dusts and soils. A spark discharge produces plasma from a soil sample, and detectors measure the optical emission from metals in the plasma to identify and quantify them. Trace metal measurements are vital in assessing whether or not the Martian environment will be toxic to human explorers. The current method of x-ray fluorescence can yield concentrations of major species only. Other instruments are incompatible with the volume, weight, and power constraints for a Mars mission. The new instrument will be developed primarily for use in the Martian environment, but it would be adaptable for terrestrial use in environmental monitoring. The NASA Glenn Research Center at Lewis Field initiated the development of the MSSP as part of Glenn's Director's Discretionary Fund project for the Spark Analysis Detection of Trace Metal Species in Martian Dusts and Soils. The objective of this project is to develop and demonstrate a compact, sensitive optical instrument for the detection of trace hazardous metals in Martian dusts and soils.
Emission and absorption spectra of water vapor plasmas generated in a wall-stabilized arc at atmospheric pressure and 4 current, and at 0.03 atm and 15 to 50 A, were measured at high spatial and spectral resolution. The gas temperature was determined from the shape of Doppler-broadened rotational lines of OH. The observed nonequilibrium population distributions over the energy levels of atoms are interpreted in terms of a theoretical state model for diffusion-controlled arc plasmas. Excellent correlation is achieved between measured and predicted occupation of hydrogen energy levels. It is shown that the population distribution over the nonpredissociating rotational-vibrational levels of the A 2 Sigma state of OH is close to an equilibrium distribution at the gas temperature, although the total density of this state is much higher than its equilibrium density. The reduced intensities of the rotational lines originating in these levels yielded Boltzmann plots that were strictly linear.
The Mars Spark Source Prototype (MSSP) hardware has been developed as part of a proof of concept system for the detection of trace metals such as lead, cadmium, and arsenic in Martian dusts and soils. A spark discharge produces plasma from a soil sample and detectors measure the optical emission from metals in the plasma that will allow their identification and quantification. Trace metal measurements are vital for the assessment of the potential toxicity of the Martian environment for human exploration. The current method of X-ray fluorescence can yield concentrations only of major species. Other instruments are incompatible with the volume, weight, and power constraints for a Mars mission. The instrument will be developed primarily for use in the Martian environment, but would be adaptable for terrestrial use in environmental monitoring. This paper describes the Mars Spark Source Prototype hardware, the results of the characterization tests, and future plans for hardware development.
Photometric spectra of the forbidden S II emission lines at 6716 and 6731 A originating in the Jovian magnetosphere are examined. The summed apparent emission rate in the two sulfur lines is plotted against the central-meridian longitude of Jupiter in System III. It is found that the total sulfur brightness exhibited a distinct minimum when the Jovian magnetic dipole was in the plane defined by the earth-Jupiter vector and the Jovian rotational axis. The observations are shown to be qualitatively consistent with an annular emitting region at the magnetic equator with a thickness of about 1 Jupiter radius and an inner radius of 4 to 5 Jupiter radii. The observations also imply a (logarithmic) characteristic electron density of approximately 3.7 per cu cm and a (logarithmic) average column abundance of about 11.5 per sq cm for singly ionized sulfur.
Explore the source record for details and available documents.
Plasma electron density measurements, interferometric and spectroscopic techniques compared with Stark H-beta line and absolute continuum intensity method
Saturation induced optical nonreciprocity in He-Ne ring laser plasma, eliminating frequency locking by using Faraday effect
Optical observations of a beam-plasma discharge (BPD) in the laboratory showed that the discharge remained confined to a diameter little more than double that of the beam for injection parallel to the magnetic field and approximately equal to that of the beam for injection at large pitch angles. The diameter was independent of beam current but varied linearly with beam velocity and inversely with magnetic field strength. The ionization rate inferred from the total emission of 3914 A, integrated over the radial extent of the beam, was proportional to the excess beam current above that requied for BPD ignition. The proportionality constant ( 12 + or - 2) x 10 to the 14th ions/cm s A was valid over a wide range of pressure and of magnetic field strength. Power loss to ionization in a 20 m path was estimated at up to 4 percent of the beam power. Evidence is presented for effective confinement of suprathermal electrons (parallel to B) by some unidentified process other than electrostatic confinement.
The binary system Capella has been observed on 1979 March 15 and on 1980 March 15-17, with the objective grating spectrometer on board the Einstein Observatory. The spectrum measured with the 1000 1/mm grating covers the range 5-30 A with a resolution less than 1 A. The spectra show evidence for a bimodal temperature distribution of emission measure in an optically thin plasma with one component about 5,000,000 K and the other one about 10,000,000 K. Spectral features can be identified with line emissions from O VIII, Fe XVII, Fe XVIII, Fe XXIV, and Ne X ions. Good spectral fits have been obtained assuming standard cosmic abundances. The data are interpreted in terms of emission from hot static coronal loops rather similar to the magnetic arch structures found on the sun. It is shown that the conditions for such a model can exist on Capella. Typical values of loop base pressure and half-length are derived for both temperature components and discussed in relation to UV observations.