Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Acquisition of partial grain orientation information using optical microscopy

Optical microscopy (OM) is often the first technique used to characterize surfaces of materials because of its simplicity and low cost. However, the information obtained by OM is usually limited to the geometry and spatial distribution of microstructural features. We present an advanced OM technique to perform quantitative microstructure analysis of polycrystalline metals and to assess partial grain orientation information from measurements of reflectance over a range of incident light directions. Our technique relies on the collection of a series of optical micrographs under controlled illumination conditions. We find a marked direction-dependence of reflectance and ascribe it to sub-micron facets on the surfaces of individual grains. These surface facets are, in turn, correlated to grain orientation. We automate our technique via digital processing and numerical analysis of micrographs, enabling it to generate a wealth of microstructure data while remaining simple to use and inexpensive to implement.

36 MATERIALS SCIENCE↗

Plasmon-Tunable Tip Pyramids: Monopole Nanoantennas for Near-Field Scanning Optical Microscopy

Squeezing optical fields into nanometer scale is the key step to perform spatially resolved near-field optics. In scattering-type near-field optical microscopy, this task is accomplished by nanoantennas that convert propagating radiation to local near-fields and vice versa. The usual nanoantenna is composed by an elongated metal structure whose longitudinal dimension is scaled to support dipole modes of localized surface plasmon resonances. However, monopole modes can also be explored if the elongated metal nanoparticle is electrically grounded on a flat metallic plateau that acts like a mirror providing the monopole's image that closes the dipole system. Here, a method for batch production of monopole nanoantennas for scattering-type near-field scanning optical microscopy is presented. The nanoantennas are composed of a micropyramidal body with a nanopyramidal end whose lateral dimension can be scaled to fine-tune localized surface plasmon resonance modes. In conclusion, the monopole character of the nanoantennas is revealed by electron energy loss spectroscopy, and their efficiency and reproducibility are tested in tip-enhanced Raman spectroscopy experiments performed on single-layer graphene and single-walled carbon nanotubes.

47 OTHER INSTRUMENTATION↗

Adaptive optics for optical microscopy [Invited]

Optical microscopy is widely used to visualize fine structures. When applied to bioimaging, its performance is often degraded by sample-induced aberrations. In recent years, adaptive optics (AO), originally developed to correct for atmosphere-associated aberrations, has been applied to a wide range of microscopy modalities, enabling high- or super-resolution imaging of biological structure and function in complex tissues. Here, we review classic and recently developed AO techniques and their applications in optical microscopy.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of laser-induced modification of collagen structure using nonlinear optical microscopy

Nonlinear optical microscopy is used to monitor changes in the collagen structure of patellar ligament after IR laser heating up to a temperature of 60 °C. Pre-denaturation modification of the tissue matrix exhibits specific properties and consists in splitting of initially parallel fibre bundles into array of divergent fibres. Image processing employing Fast Fourier transform analysis is used for characterising images of the fibre structure and determining the collagen orientation index. An increase in manifestation of laser-induced disordering with an increase in IR laser radiation power from 0.3 to 2 W is accompanied by a decrease in the collagen orientation index. The specific disorganisation of the collagen tissue structure during laser heating is supposed to be due to fast speed and local action of the laser heating, which leads to mechanical distortions of the structural elements of tissue matrix. (paper)

36 MATERIALS SCIENCE↗

Generalized spectral method for near-field optical microscopy

Electromagnetic interaction between a sub-wavelength particle (the “probe”) and a material surface (the “sample”) is studied theoretically. The interaction is shown to be governed by a series of resonances corresponding to surface polariton modes localized near the probe. The resonance parameters depend on the dielectric function and geometry of the probe as well as on the surface reflectivity of the material. Calculation of such resonances is carried out for several types of axisymmetric probes: spherical, spheroidal, and pear-shaped. For spheroids, an efficient numerical method is developed, capable of handling cases of large or strongly momentum-dependent surface reflectivity. Application of the method to highly resonant materials, such as aluminum oxide (by itself or covered with graphene), reveals a rich structure of multi-peak spectra and nonmonotonic approach curves, i.e., the probe-sample distance dependence. These features also strongly depend on the probe shape and optical constants of the model. For less resonant materials such as silicon oxide, the dependence is weak, so that the spheroidal model is reliable. The calculations are done within the quasistatic approximation with radiative damping included perturbatively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extraterrestrial optical microscopy.

Extraterrestrial optical microscopy, discussing experiment, telemetry, data interpretation and instrument characteristics concerning biological, cytochemical and petrographic microscopes

Soffen, G. A.↗

Comparing non-destructive 3D X-ray computed tomography with destructive optical microscopy for microstructural characterization of fiber reinforced composites

Due to their lightweight, relatively high stiffness properties, and formability into complex shapes, discontinuous fiber composites are advantageous for producing small and medium size components. Improved characterization techniques and post-processing methodologies are required for more reliable quantification of the microstructure and defect distributions in these materials, in order to employ model-based approaches to assess their structural integrity. This work compares a non-destructive X-ray approach with a destructive optical microscopy approach for characterizing the microstructural attributes, specifically the fiber volume fraction, porosity volume fraction, fiber orientation distribution, and fiber length distribution of discontinuous glass fibers in a polypropylene matrix. Additionally, a method for destructively determining the ambiguous components of the orientation tensor (related to the sign ambiguity of the out-of-plane angle in a destructive cross-sectional cut of a fiber) over a large surface area is included. It was found that fiber volume fraction and average fiber aspect ratio matched well, while fiber orientation and porosity detection had small but notable differences. The differences in the detection capabilities of each technique are quantified and discussed shedding light on the specific advantages and disadvantages of each approach, and enabling engineers to quantify uncertainty in their microstructural characterization measurements especially as they relate to model based structural integrity activities.

Non-destructive testing↗

The equation of state of 5-nitro-2,4-dihydro-1,2,4,-triazol-3-one determined via in-situ optical microscopy and interferometry measurements

Quasi-hydrostatic high-pressure equations of state (EOS) are typically determined, for crystalline solids, by measuring unit-cell volumes using x-ray diffraction (XRD) techniques. However, when characterizing low-symmetry materials with large unit cells, conventional XRD approaches may become problematic. To overcome this issue, we examined the utility of a “direct” approach toward determining high pressure material volume by measuring surface area and sample thickness using optical microscopy and interferometry (OMI), respectively. We have validated this experimental approach by comparing results obtained for 2,4,6-triamino-1,3,5-trinitrobenzene TATB with an EOS determined from synchrotron XRD measurements; and, a good match is observed. We have measured the high pressure EOS of 5-nitro-2,4-dihydro-1,2,4,-triazol-3-one (α-NTO) up to 28 GPa. No high-pressure XRD EOS data have been published on α-NTO, probably due to its complex crystal structure. The results of this study suggest that OMI is a reliable and versatile alternative for determining EOSs, especially when conventional methodologies are impractical.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

Deep-learning-aided extraction of optical constants in scanning near-field optical microscopy

Scanning near-field optical microscopy is one of the most effective techniques for spectroscopy of nanoscale systems. However, inferring optical constants from the measured near-field signal can be challenging because of a complicated and highly nonlinear interaction between the scanned probe and the sample. Conventional fitting methods applied to this problem often suffer from the lack of convergence or require human intervention. Here, we develop an alternative approach where the optical parameter extraction is automated by a deep learning network. The network provides an initial estimate that is subsequently refined by a traditional fitting algorithm. In conclusion, we show that this method demonstrates superior accuracy, stability against noise, and computational speed when applied to simulated near-field spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Axial Plane Optical Microscopy

We present axial plane optical microscopy (APOM) that can, in contrast to conventional microscopy, directly image a sample’s cross-section parallel to the optical axis of an objective lens without scanning. APOM combined with conventional microscopy simultaneously provides two orthogonal images of a 3D sample. More importantly, APOM uses only a single lens near the sample to achieve selective-plane illumination microscopy, as we demonstrated by three-dimensional (3D) imaging of fluorescent pollens and brain slices. This technique allows fast, high-contrast, and convenient 3D imaging of structures that are hundreds of microns beneath the surfaces of large biological tissues.

47 OTHER INSTRUMENTATION↗

Multiparallel Three-Dimensional Optical Microscopy

Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.

Nguyen, Lam K.↗

Phase stabilized homodyne of infrared scattering type scanning near-field optical microscopy

Scattering type scanning near-field optical microscopy (s-SNOM) allows sub diffraction limited spatial resolution. Interferometric homodyne detection in s-SNOM can amplify the signal and extract vibrational responses based on sample absorption. A stable reference phase is required for a high quality homodyne-detected near-field signal. This work presents the development of a phase stabilization mechanism for s-SNOM to provide stable homodyne conditions. The phase stability is found to be better than 0.05 rad for the mid infrared light source. Phase stabilization results in improved near field images and vibrational spectroscopies. Spatial inhomogeneities of the boron nitride nanotubes are measured and compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗