Extraterrestrial optical microscopy.
Extraterrestrial optical microscopy, discussing experiment, telemetry, data interpretation and instrument characteristics concerning biological, cytochemical and petrographic microscopes
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Extraterrestrial optical microscopy, discussing experiment, telemetry, data interpretation and instrument characteristics concerning biological, cytochemical and petrographic microscopes
Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.
Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.
Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.
Herein, we demonstrate the utility of optical microscopy as an accessible technique for the in situ visualization of dendrite growth within polymer–sulfide composite solid-state electrolytes. The composite electrolyte features in situ polymerization and cross-linking of the polymer between ceramic particles, which opens up extensive opportunities for accelerated materials discovery, given the vast array of acrylate/methacrylate monomers available. Specifically, the cross-linked polymer poly(triethylene glycol dimethacrylate) (poly(TEGDMA)) was observed to effectively fill pores and inhibit dendrite growth at the lithium metal interface, attributed to its glassy state at room temperature. This work represents the first application of optical microscopy to illustrate that the incorporation of glassy, undoped polymers such as poly(TEGDMA) can serve as a viable strategy for dendrite suppression in solid-state composite electrolytes.
Near-field scanning optical microscopy is a relatively new but very powerful technique for obtaining several metrological parameters at nanometer range spatial resolution. It is logical to think deploying it into space applications like diagnostics of protein crystal growth under microgravity conditions. One may attempt to deploy existing instrumentation and expect some results. However, the existing technology and commercial instrumentation is tailored to ground based laboratory situations. Even in those laboratory conditions, the role of fluids (common in crystal growth), rough objects (such as a crystal under growth), etc. on the instrumentation is only recently being investigated. These aspects combined with effects of reduced gravity environment are going to make the problem more complex. These technological challenges must be tackled for meaningful system operation in space. Since the microscopy concept has not been attempted so far in space, all of the actual problems are unknown. Nevertheless, based on current literature, some possible problems and potential solutions are described here. One may use the discussion for system modification/optimization during initial use of this kind of microscopy in space.
Near-field scanning optical microscopy is an established technique for sub-wavelength spatial resolution in imaging, spectroscopy, material science, surface chemistry, polarimetry, etc. A significant amount of confidence has been established for thin hard specimens in air. However when soft, biological, rough, in aqueous environment object, or a combination is involved, the progress has been slow. The tip-sample mechanical interaction, heat effects to sample, drag effects to the probe, difficulty in controlling tip-sample separation in case of rough objects, light scattering from sample thickness, etc. create problems. Although these problems are not even fully understood, there have been attempts to study them with the aim of performing reliable operations. In this review we describe these attempts. Starting with general problems encountered, various effects like polarization, thermal, and media are covered. The roles of independent tip-sample distance control tools in the relevant situations are then described. Finally progress in fluid cell aspect has been summarized.
Additive manufacturing (AM) is a rapidly growing technology. An area of major importance is the integrity and repeatability of AM parts. The goal is to reduce obstacles to certify AM built parts to allow for use in critical aerospace applications. In-situ nondestructive evaluation sensors can be used for build assessment and can potentially play a key role in certifying AM parts. For example, melt pool features are understood to have a strong correlation to microstructural defects and the use of a near infrared (NIR) camera can be used to record the melt pool, cooling areas, and temperature gradients during the build. This work explores the use of a low cost NIR camera to obtain single line track imagery of the Ti-6Al-4V melt pools for various processing parameters. The NIR camera is radiometrically calibrated and configured in-line with the laser source to obtain high resolution imagery of the melt pool shape and dynamics. The challenge to measure melt pool shapes is to identify the transition points between the metal solid to liquid phase. Factors for melt pool measurements such as thermal camera pixel resolution, surface emissivity, and blurring due to the laser beam movement are discussed. Lastly, the melt pool imagery are compared to optical microscopy measurements for validation.
Thermochemical models of detonation that estimate performance (e.g., detonation velocity, energy delivery, etc.), are based on assumptions that carbon condensates (soot) formed during detonation is largely similar to bulk carbon. However, soot constituents can range from amorphous carbon to nanodiamond and include other material phases. Since thermodynamic properties of the soot such as compressibility are imperative for accurate thermochemical modeling of detonation reaction chemistry, experimental measurements of the equation of state (EOS) which determine the compressibility are vital. Due to the mixed-phase nature of detonation soot, typical methods to measure the EOS (e.g., x-ray diffraction) are untenable. In this study, the high-pressure EOS up to 20 GPa was determined for detonation soot collected from PBX 9502, Composition B (Comp B), Hexanitrostilbene (HNS), and LX-21 high explosives by employing a direct volume technique using optical microscopy and interferometry in a diamond anvil cell. Comp B soot was determined to be the least compressible [K 0 = 57.9(17) GPa] with HNS soot [K 0 = 53.7(15) GPa], LX-21 soot [K 0 = 45.8(51) GPa], and PBX 9502 soot [K 0 = 28.2(27) GPa] being more compressible, likely due to differences in nanodiamond content as compared to amorphous carbon and graphite content.
We report what is believed to be the first experimental demonstration of silver coating by a wet chemical process on tapered fiber tips used in near-field scanning optical microscopy. The process is at room temperature and pressure and takes only a few minutes to complete. Many tips can be simultaneously coated.
We report what is believed to be the first experimental demonstration of gold coating by a chemical baking process on tapered fiber tips used in near-field scanning optical microscopy. Many tips can be simultaneously coated.
Explore the source record for details and available documents.
A bench metallograph was converted into a micro contact imager by the addition of a tribometer employing a steel ball in sliding contact with a glass disk. The sliding contact was viewed in real time by means of projection microscope optics. The dynamics of abrasive particles and of solid lubricant particles within the contact were observed in detail. The contact was characterized by a constantly changing pattern of elastic strain with the passage of surface discontinuities and solid particles. Abrasive particles fragmented upon entering the contact, embedded in one surface and scratched the other; in contrast, the solid lubricant particles flowed plastically into thin films. The rheological behavior of the lubricating solids gave every appearance of a paste-like consistency within the Hertzian contact.
A bench metallograph was converted into a 'micro contact imager' by the addition of a tribometer employing a steel ball in sliding contact with a glass disk. The sliding contact was viewed in real time by means of projection microscope optics. The dynamics of abrasive particles and of solid lubricant particles within the contact were observed in detail. The contact was characterized by a constantly changing pattern of elastic strain with the passage of surface discontinuities and solid particles. Abrasive particles fragmented upon entering the contact, embedded in one surface and scratched the other; in contrast, the solid lubricant particles flowed plastically into thin films. The rheological behavior of the lubricating solids gave every appearance of a paste-like consistency within the Hertzian contact.
Metal surface finishes of tin, zinc and cadmium are often applied to electronic components, mechanical hardware and other structures. These finishes sometimes unpredictably may form metal whiskers over periods that can take from hours to months or even many years. The metal whiskers are crystalline structures commonly having uniform cross sectional area along their entire length. Typical whisker dimensions are nominally on the order of only a few microns (um) across while their lengths can extend from a few microns to several millimeters. Metal whiskers pose a reliability hazard to electronic systems primarily as an electrical shorting hazard. The extremely narrow dimensions of metal whiskers can make observation with optical techniques very challenging. The videos herein were compiled to demonstrate the complexities associated with optical microscope inspection of electronic and mechanical components and assemblies for the presence or absence of metal whiskers. The importance of magnification, light source and angle of illumination play critical roles in being able to detect metal whiskers when present. Furthermore, it is demonstrated how improper techniques can easily obscure detection. It is hoped that these videos will improve the probability of detecting metal whiskers with optical inspection techniques.
The quantum efficiency of micro-light emitting diodes (micro-LEDs) is lower than that of large area LEDs. This efficiency reduction is typically attributed to the nonradiative Shockley–Read–Hall recombination at the surface defects and current leakage through the sidewall region without a clear distinction between these effects. In this work, we attempt to find out which of these phenomena is most critical for the reduced efficiency of micro-LEDs. This has been done by mapping electroluminescence (EL) and photoluminescence (PL) and measuring PL dynamics in blue GaN micro-LEDs fabricated by dry etching. It has been found that in the as-etched device, the EL intensity is much lower than in devices with KOH etching and atomic layer deposition of SiO 2 . This effect is especially pronounced close to the sidewalls. On the other hand, PL decay times are similar in as-etched and passivated devices, both in their center and at the sidewalls. This allows concluding that the main mechanism of the reduced efficiency of micro-LEDs fabricated by dry etching is the current leakage in the sidewall region and not the nonradiative recombination. The KOH etching has been found to be the most efficient means to eliminate the current leakage.
The hyperaccumulation phenomenon holds significant potential for Ni agromining in ultramafic areas; however, data on tropical hyperaccumulator species, particularly regarding metal distribution and tolerance mechanisms, remain scarce. Here, this study characterized the foliar elemental distribution of Blepharidium guatemalense, analyzed its metal localization at both tissue and cellular levels, and quantified its Ni accumulation when grown in Brazilian ultramafic soil. Plants were grown in pots for 90 days, and Ni concentrations in the aerial biomass and bio-ore were determined. Synchrotron-based micro-X-ray fluorescence (S-µXRF) was used to assess metal distribution in tissues, supplemented by microscopic examination with dimethylglyoxime (DMG) to visualize Ni accumulation in specific cell types. B. guatemalense reached 19,000 mg kg −1 Ni in leaves. Processing leaf biomass produced ash containing 24 wt% Ni, indicating promising metal-recovery potential for the species. S-µXRF revealed that Ni was predominantly localized in the central and secondary veins of the leaves, suggesting efficient vascular transport. Microscopic analysis using the colorimetric reagent DMG further showed that Ni accumulation occurs near the epidermis and phloem, suggesting that B. guatemalense employs specific physiological mechanisms for Ni translocation, potentially supporting both defense and growth functions. These results establish B. guatemalense as a promising candidate for large-scale Ni agromining in tropical regions.
Explore the source record for details and available documents.