Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Micrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optical contact micrometer

Certain examples provide optical contact micrometers and methods of use. An example optical contact micrometer includes a pair of opposable lenses to receive an object and immobilize the object in a position. The example optical contact micrometer includes a pair of opposable mirrors positioned with respect to the pair of lenses to facilitate viewing of the object through the lenses. The example optical contact micrometer includes a microscope to facilitate viewing of the object through the lenses via the mirrors; and an interferometer to obtain one or more measurements of the object.

47 OTHER INSTRUMENTATION↗

Reversible Optical Control of Conjugated Polymer Solubility with Sub-micrometer Resolution

Organic electronics promise to provide flexible, large-area circuitry such as photovoltaics, displays, and light emitting diodes that can be fabricated inexpensively from solutions. A major obstacle to this vision is that most conjugated organic materials are miscible, making solution-based fabrication of multilayer or micro- to nanoscale patterned films problematic. Here we demonstrate that the solubility of prototypical conductive polymer poly(3-hexylthiophene) (P3HT) can be reversibly "switched off" using high electron affinity molecular dopants, then later recovered with light or a suitable dedoping solution. Using this technique, we are able to stack mutually soluble materials and laterally pattern polymer films by evaporation or with light, achieving sub-micrometer, optically limited feature sizes. After forming these structures, the films can be dedoped without disrupting the patterned features; dedoped films have identical optical characteristics, charge carrier mobilities, and NMR spectra as as-cast P3HT films. Furthermore, this method greatly simplifies solution-based device fabrication, is easily adaptable to current manufacturing workflows, and is potentially generalizable to other classes of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diameter Quality Control of Nb 3 Sn Wires for MQXF Cables in the USA

During this project, the 0.850 ± 0.003 mm Nb 3 Sn wires for the low-beta quadrupole magnets 'MQXFA' procured for the U.S. LHC Accelerator R&D Program (LARP) and the U.S. High Luminosity LHC Accelerator Upgrade Project (US HL-LHC AUP, or simply AUP) are received at Lawrence Berkeley National Laboratory (LBNL). There, the wires are respooled and then fabricated into Rutherford cables for winding coils. As part of the quality control program, AUP obtains from the wire manufacturer values of the maximum, average, minimum, and standard deviation of the two orthogonal axes, which are assessed prior to shipment approval. At LBNL, a dual-axis optical micrometer is used to measure the wire diameter of each spool every ~30 cm prior to cabling. This helps decide whether wire pieces with abnormal diameters should be distributed across the cable cross section, in order to improve cable parameter quality and mechanical stability consistency. This paper presents: 1) diameter data of LARP cables and of the first AUP cables made using wires acquired under LARP; 2) our deviation acceptance/rejection justification; and 3) the impact of wire diameter statistics on cable fabrication.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long-Length SiC/SiC Tube Irradiation Experiment at LWR Temperatures Inserted into HFIR

This report describes the pre-irradiation characterization and successful assembly of a High Flux Isotope Reactor (HFIR) irradiation experiment designed to assess radiation-induced lateral bowing of silicon carbide fiber–reinforced, silicon carbide matrix composite (SiC/SiC) components under a radial fast neutron flux gradient at representative light-water reactor (LWR) temperatures of approximately 300 °C. The over-arching goal of this work is to validate thermomechanical models of SiC/SiC composite fuel assembly distortion used to predict the extent of lateral bowing and dose at which bowing reaches a maximum value. Ultimately, these models are used to ensure that fuel assembly distortion does not block coolant channels, interfere with control rod/blade movements, and/or impact local reactivity. The experiment contains six cladding tube specimens that are approximately 558.5 mm long with representative pressurized water reactor (PWR) outer and inner diameters of 9.5 mm and 7.5 mm, respectively. The specimens were thoroughly characterized prior to irradiation using traditional dimensional inspection and surface profilometry so that these measurements can later be compared with similar measurements that will be made post-irradiation to determine radiation-induced deformations. Furthermore, fine engraving markers were inscribed along the outer surfaces of the specimen and mapped using analytic photography and a three-dimensional stage. This technique allowed for accurate measurements of the marker spacings, which can be compared with similar measurements that will be made post-irradiation to provide local radiation-induced strain mapping. A light curtain optical micrometer was also employed to measure the pre-irradiation bowing of each specimen. The experiment was successfully assembled and inserted into position VXF-19 for HFIR cycle 516, which began May 12, 2026. The experiment will be removed after cycle 519, which is currently scheduled to end in December 2026.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A simple optical system delivering a tunable micrometer pink beam that can compensate for heat-induced deformations

The radiation from an undulator reflected from one or more optical elements (usually termed `pink-beam') is used in photon-hungry experiments. The optical elements serve as a high-energy cutoff and for focusing purposes. One of the issues with this configuration is maintaining the focal spot dimension as the energy of the undulator is varied, since this changes the heat load absorbed by the first optical element. Finite-element analyses of the power absorbed by a side water-cooled mirror exposed to the radiation emitted by an undulator at the Advanced Photon Source (APS) and at the APS after the proposed upgrade (APSU) reveals that the mirror deformation is very close to a convex cylinder creating a virtual source closer to the mirror than the undulator source. Here a simple optical system is described based on a Kirkpatrick–Baez pair which keeps the focus size to less than 2 µm (in the APSU case) with a working distance of 350 mm despite the heat-load-induced change in source distance. Detailed ray tracings at several photon energies for both the APS and APSU show that slightly decreasing the angle of incidence on the mirrors corrects the change in the `virtual' position of the source. The system delivers more than 70% of the first undulator harmonic with very low higher-orders contamination for energies between 5 and 10 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cytometric Catheter for Neurosurgical Applications

Implantation of neural progenitor cells into the central nervous system has attracted strong interest for treatment of a variety of pathologies. For example, the replacement of dopamine-producing (DA) neural cells in the brain appears promising for the treatment of patients affected by Parkinson's disease. Previous studies of cell-replacement strategies have shown that less than 90% of implanted cells survive longer than 24 - 48 hours following the implantation procedure. However, it is unknown if these cells were viable upon delivery, or if they were affected by other factors such as brain pathology or an immune response. An instrumented cell-delivery catheter has been developed to assist in answering these questions by facilitating quantification and monitoring of the viability of the cells delivered. The catheter uses a fiber optic probe to perform flourescence-based cytometric measurments on cells exiting the port at the catheter tip. The current implementation of this design is on a 3.2 mm diameter catheter with 245 micrometer diameter optical fibers. Results of fluorescence testing data are presented and show that the device can characterize the quantity of cell densities ranging from 60,000 cells/ml to 600,000 cells/ml with a coefficient of determination of 0.93.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization and Application of a Hybrid Optical Microscopy/Laser Ablation Liquid Vortex Capture/Electrospray Ionization System for Mass Spectrometry Imaging with Sub-micrometer Spatial Resolution

Herein, a commercial optical microscope, laser microdissection instrument was coupled with an electrospray ionization mass spectrometer via a low profile liquid vortex capture probe to yield a hybrid optical microscopy/mass spectrometry imaging system. The instrument has bright-field and fluorescence microscopy capabilities in addition to a highly focused UV laser beam that is utilized for laser ablation of samples. With this system, material laser ablated from a sample using the microscope was caught by a liquid vortex capture probe and transported in solution for analysis by electrospray ionization mass spectrometry. Both lane scanning and spot sampling mass spectral imaging modes were used. The smallest area the system was able to ablate was ~0.544 μm × ~0.544 μm, achieved by oversampling of the smallest laser ablation spot size that could be obtained (~1.9 μm). With use of a model photoresist surface, known features as small as ~1.5 μm were resolved. The capabilities of the system with real world samples were demonstrated first with a blended polymer thin film containing poly(2-vinylpyridine) and poly(N-vinylcarbazole). Using spot sampling imaging, sub-micrometer sized features (0.62, 0.86, and 0.98 μm) visible by optical microscopy were clearly distinguished in the mass spectral images. A second real world example showed the imaging of trace amounts of cocaine in mouse brain thin tissue sections. Lastly, with use of a lane scanning mode with ~6 μm × ~6 μm data pixels, features in the tissue as small as 15 μm in size could be distinguished in both the mass spectral and optical images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new perspective on plasmonics: Confinement and propagation length of surface plasmons for different materials and geometries [A new perspective on materials for plasmonics]

Surface-plasmon polaritons are electromagnetic waves propagating on the surface of a metal. Thanks to subwavelength confinement, they can concentrate optical energy on the micrometer or even nanometer scale, enabling new applications in bio-sensing, optical interconnects, and nonlinear optics, where small footprint and strong field concentration are essential. The major obstacle in developing plasmonic applications is dissipative loss, which limits the propagation length of surface plasmons and broadens the bandwidth of surface-plasmon resonances. Here, a new analysis of plasmonic materials and geometries is presented which fully considers the tradeoff between propagation length and degree of confinement. It is based on a two-dimensional analysis of two independent figures of merit and the analysis is applied to relevant plasmonic materials, e.g., noble metals, aluminum, silicon carbide, doped semiconductors, graphene, etc. Furthermore, the analysis provides guidance on how to improve the performance of any particular plasmonic application and substantially eases the selection of the plasmonic material.

36 MATERIALS SCIENCE↗

A Bayesian desmearing algorithm for Bonse–Hart USANS with anisotropic scattering

Ultra-small-angle neutron scattering (USANS) using Bonse–Hart optics provides micrometer-scale structural insights but suffers from severe slit-geometry smearing. While well-established for isotropic systems, quantitative desmearing of anisotropic data remains a challenge because conventional corrections break down for non-radial scattering. In this work, we address this by developing a resolution-aware Bayesian framework that explicitly incorporates anisotropy via an affine deformation to the scattering pattern, guided by the principle of parsimony. This results in orientation-resolved point-spread functions that enable a self-consistent determination of both the resolution and deformation parameters. Using Gaussian process regression with uncertainty quantification and a probabilistic correction for multiple scattering, we demonstrate the framework’s effectiveness through numerical benchmarks and experimental studies of a stretched polymer melt. Our approach enables the seamless integration of SANS and USANS data, facilitating quantitative structural analysis of deformed materials at nanometer to micrometer scales.

36 MATERIALS SCIENCE↗

Imaging the magnetic nanodomains in Nd 2 Fe 14 B

Here, we study magnetic domains in Nd 2 Fe 14 B single crystals using high resolution magnetic force microscopy (MFM). Previous MFM studies and small angle neutron scattering experiments suggested the presence of nanoscale domains in addition to optically detected micrometer-scale ones. We find, in addition to the elongated, wavy nanodomains reported by a previous MFM study, that the micrometer-sized, star-shaped fractal pattern is constructed of an elongated network of nanodomains ~20 nm in width, with resolution-limited domain walls thinner than 2 nm. While the microscopic domains exhibit significant resilience to an external magnetic field, some of the nanodomains are sensitive to the magnetic field of the MFM tip.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing Charge Dynamics in Diamond with an Individual Color Center

Control over the charge states of color centers in solids is necessary to fully utilize them in quantum technologies. However, the microscopic charge dynamics of deep defects in wide-band-gap semiconductors are complex, and much remains unknown. We utilize a single-shot charge-state readout of an individual nitrogen-vacancy (NV) center to probe the charge dynamics of the surrounding defects in diamond. We show that the NV center charge state can be converted through the capture of holes produced by optical illumination of defects many micrometers away. With this method, we study the optical charge conversion of silicon-vacancy (SiV) centers and provide evidence that the dark state of the SiV center under optical illumination is SiV 2– . These measurements illustrate that charge carrier generation, transport, and capture are important considerations in the design and implementation of quantum devices with color centers and provide a novel way to probe and control charge dynamics in diamond.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Size-Dependent Thermal Shifts to MOF Nanocrystal Optical Gaps Induced by Dynamic Bonding

Conventional semiconductor nanocrystals exhibit wide-ranging optical behavior, whereas the size-dependent photophysical properties of metal–organic framework (MOF) nanocrystals remain an open research frontier. Furthermore, we present size- and temperature-dependent optical absorption spectra of common MOFs with particle sizes ranging from tens of nanometers to several micrometers. All materials exhibit optical gaps that decrease at elevated temperatures, which we attribute to the dynamic nature of MOF metal–linker bonds. Accordingly, whereas the labile titanium–carboxylate bonds of MIL-125 give rise to bandgaps that red-shift by ~600 meV over 300 K, the more rigid zinc–imidazolate bonds of ZIF-8 produce a red-shift of only ~10 meV. Furthermore, smaller particles induce far larger decreases to optical gaps. Taken together, these results suggest MOF bonding becomes more flexible with smaller nanocrystal sizes, offering a powerful tool for manipulating optical behavior through composition, temperature, and dimensionality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical Characterization of Solid-Liquid Slurries at High Weight Fractions Using Optical and Ultrasonic Methods, Final Report

Remediation of highly radioactive waste is a major technical and programmatic challenge for the DOE. Rapid, on-line physical characterization of highly concentrated slurries is required for the safe and efficient remediation of 90 million gallons of high level radioactive waste (HLW), sodium bearing waste, and mixed waste. The research presented here, describes a collaborative effort between Pacific Northwest National Laboratory (PNNL) and the University of Washington to directly address the need for rapid on-line characterization of the physical properties of HLW slurries during all phases of the remediation process, from in-tank characterization of sediments to monitoring of the concentration, particle size, and degree of agglomeration and gelation of slurries during transport. Near-surface characterization of the slurry flow in the particle size range from nanometer to micrometer is examined using optical low coherence reflectometry. Volumetric characterization at depths in the slurry flow, up to several centimeters in the particle size range from the micrometer to millimeter, is realized by utilizing ultrasonic backscatter and diffuses fields. One of the strengths, the teaming up of significant talents in both experimental and theoretical optics (University of Washington) and in ultrasonics [Pacific Northwest National Laboratory (PNNL)] provides a synergistic approach to integrate these complimentary techniques. One of the benefits of this combined approach is the physical characterization of HLW over a concentration and particle size range that is broader than can be achieved with today’s technology. This will avoid a costly increase in waste stream volume due to excess dilution, and will lessen chance of plugging pipes that could shut down expensive processing lines.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

VERY LARGE INTERSTELLAR GRAINS AS EVIDENCED BY THE MID-INFRARED EXTINCTION

The sizes of interstellar grains are widely distributed, ranging from a few angstroms to a few micrometers. The ultraviolet (UV) and optical extinction constrains the dust in the size range of a couple hundredths of micrometers to several submicrometers. The near and mid infrared (IR) emission constrains the nanometer-sized grains and angstrom-sized very large molecules. However, the quantity and size distribution of micrometer-sized grains remain unknown because they are gray in the UV/optical extinction and they are too cold and emit too little in the IR to be detected by IRAS, Spitzer, or Herschel. In this work, we employ the ∼3–8 μm mid-IR extinction, which is flat in both diffuse and dense regions to constrain the quantity, size, and composition of the μm-sized grain component. We find that, together with nano- and submicron-sized silicate and graphite (as well as polycyclic aromatic hydrocarbons), μm-sized graphite grains with C/H ≈ 137 ppm and a mean size of ∼1.2 μm closely fit the observed interstellar extinction of the Galactic diffuse interstellar medium from the far-UV to the mid-IR, as well as the near-IR to millimeter thermal emission obtained by COBE/DIRBE, COBE/FIRAS, and Planck up to λ ≲ 1000 μm. The μm-sized graphite component accounts for ∼14.6% of the total dust mass and ∼2.5% of the total IR emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Light driven microflow in ice

We optically pump water through micrometer thin ice sheets. The ice is locally moved with speeds exceeding 5 cm/s by repetitive melting and freezing, which occurs around a moving infrared laser spot. The minimal channel width is 10 {mu}m. The diffusion limitation of ice allows for fast spatial biomolecule control without predefined channels, valves, or external pumps. Dye molecules are pumped across an ice-ice interface, showing the possibility of microfluidic applications. Pumping in ice is three orders of magnitude faster than the previously shown for thermoviscous pumping in water.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional optical trapping and orientation of microparticles for coherent X-ray diffraction imaging

Optical trapping has been implemented in many areas of physics and biology as a noncontact sample manipulation technique to study the structure and dynamics of nano-andmesoscale objects. It provides a unique approach for manipulating microscopic objects without inducing undesired changes in structure. Combining optical trapping with hard X-ray microscopy techniques, such as coherent diffraction imaging and crystallography, provides a nonperturbing environment where electronic and structural dynamics of an individual particle in solution can be followed in situ. It was previously shown that optical trapping allows the manipulation of micrometer-sized objects for Xray fluorescence imaging. However, questions remain over the ability of optical trapping to position objects for X-ray diffraction measurements, which have stringent requirements for angular stability. Our work demonstrates that dynamic holographic optical tweezers are capable of manipulating single micrometer-scale anisotropic particles in a microfluidic environment with the precision and stability required for X-ray Bragg diffraction experiments-thus functioning as an "optical goniometer." The methodology can be extended to a variety of X-ray experiments and the Bragg coherent diffractive imaging of individual particles in solution, as demonstrated here, will be markedly enhanced with the advent of brighter, coherent X-ray sources.

Gao, Yuan↗

Optical manipulators of microparticles using femtosecond laser radiation

Two setups for manipulating (translocation, stretching, rotation) microscopic objects (with the dimensions from several nanometers to tens of micrometers) are developed based on optical trapping by femtosecond laser radiation. The possibility of single-cell translocation is shown. The possibility of destructing malignant cells as well as of cutting off a fragment from a malignant cell cluster due to the rapture of bonds is demonstrated in multiphoton absorption of femtosecond light pulses. The possibility of the holographic control to move several particles simultaneously is shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transparency through Structural Disorder: A New Concept for Innovative Transparent Ceramics

Transparent polycrystalline ceramics present signi fi cant eco- nomical and functional advantages over single crystal materials for optical, communication, and laser technologies. To date, transparency in these ceramics is ensured either by an optical isotropy (i.e., cubic symmetry) or a nanometric crystallite size, and the main challenge remains to eliminate porosity through complex high pressure - high temperature synthesis. Here we introduce a new concept to achieve ultimate transparency reaching the theoretical limit. We use a controlled degree of chemical disorder in the structure to obtain optical isotropy at the micrometer length scale. This approach can be applied in the case of anisotropic structures and micrometer scale crystal size ceramics. We thus report Sr 1+ x /2 Al 2+ x Si 2 - x O 8 (0 < x ≤ 0.4) readily scalable polycrystalline ceramics elaborated by full and congruent crystallization from glass. These materials reach 90% transmittance. This innovative method should drive the development of new highly transparent materials with technologically relevant applications.

36 MATERIALS SCIENCE↗