Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Operation optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Direct air capture with amino acid solvent: Operational optimization using a crossflow air‐liquid contactor

Direct air capture (DAC) is a negative emission technology for removing CO2 from the atmosphere to maintain the CO 2 level within a reasonable range so as to address greenhouse effects. In this study, the operational optimization of lab-scale DAC has been investigated using a crossflow air-liquid contactor loaded with a three dimensionally printed Gyroid packing structure and a potassium sarcosinate solvent. The effects of various parameters, including feed air flow rate, liquid solvent flow rate, contactor geometry, and ambient temperature, are examined. The results demonstrate that the Gyroid packing design achieves comparable CO 2 capture performance to conventional packed beds but with a significantly lower pressure drop of up to 77.8%, suggesting its potential as an efficient and cost-effective solution for gas–liquid contactors in DAC. Additionally, the study explores the climate impact on CO 2 capture performance and finds that as the air temperature increases from 35 to 95°F at a fixed relative humidity of 80%, the CO 2 capture rate increased from 23.2% to 46.8% with better stability. The research highlights the importance of optimizing contactor design and operational conditions to improve the CO 2 capture rate and feasibility of DAC systems as a negative emission technology for addressing greenhouse effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Multi-Timescale Optimal Operation Framework for Integrated Economic and Reliability Analysis of Hybrid Power Plants

This paper introduces a hierarchical modeling framework for hybrid power plants (HPP) to facilitate the operation of HPP in power systems similar to conventional generators (Congens) in the integrated multi-timescale optimal operation framework. To consider the uncertainties of HPP renewable power in the day-ahead scheduling, distributionally robust optimization (DRO) is used. To ensure that the state-of-charge (SOC) of energy storage systems in HPPs aligns closely with the planned value for long-term reliability, real-time SOC management is incorporated. In addition, an adjustable real-time control is designed for the robust delivery of HPP real-time services. Case studies performed on a revised IEEE 39-bus system demonstrate the effectiveness of the proposed framework for HPP operation. Simulation results highlight that the proposed framework not only can help operators schedule HPP similar to Congens in varying weather conditions but can also maintain the frequency reliability of the system.

frequency stability

Marine energy supported multi-energy system planning and operation optimization for sustainable coastal community

The growing need for sustainable energy solutions in coastal areas necessitates the development of integrated systems that leverage abundant marine resources. In this study, a standalone Marine Energy Supported Multi-Energy System (MRE-MES) is designed for sustainable coastal community development, utilizing renewable marine resources, including offshore wind, wave, and solar energy, to address the energy needs of electricity, heat, freshwater, and hydrogen. The proposed MRE-MES incorporates a co-optimization model that simultaneously balances capacity planning and operational efficiency to minimize costs and environmental impacts. The system is tested under different renewable energy penetration levels and demand uncertainties, using a two-stage stochastic programming to account for variability in renewable resources and consumption needs. The experimental results indicate that in the optimal system capacity configuration, the percentage of total renewable energy generation is around 80 %, with or without capacity limitation constraints on PV, water tank, and hydrogen storage. Compared to the worst-case scenario in Monte Carlo experiments, two-stage stochastic optimization results in a more robust decision that effectively mitigates the risks posed by future uncertain demand conditions. In conclusion, the findings highlight the viability of marine energy for providing a resilient, comprehensive energy solution to coastal communities.

Capacity planning

Optimal operation of solid-oxide electrolysis cells considering long-term chemical degradation

Optimizing the performance of solid oxide electrolysis cells (SOECs) for long-term hydrogen (H 2 ) production at high temperatures is crucial, as prolonged operation leads to efficiency losses and shorter cell lifespans due to chemical degradation. Here, in this work, we adopt a quasi-steady state approach for dynamic optimization over extended operational periods to address the disparity in timescales between cell operation and degradation. Integrating a 2-D non-isothermal SOEC model with balance-of-plant (BOP) equipment, we explore three optimization objectives: minimizing terminal degradation, maximizing integral efficiency, and minimizing the levelized cost of H 2 (LCOH). Our dynamic optimization algorithm reduces LCOH by 9.5% and 16% compared to strategies focusing solely on terminal degradation and integral efficiency, respectively. For electricity prices of 0.03 $\$$/mWh and 0.3 $\$$ mWh optimal replacement schedules range from 5 to 2 years, depending on the operational mode. Furthermore, a flexible operational mode yields additional improvements in LCOH over traditional galvanostatic and potentiostatic modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Reverse Osmosis (RO) are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in (ultra-filtration) UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square error (RMSE) metric. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent covariates across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is studied for both direct and recursive RF modelling approaches across increasing forecast horizons. Accurate prediction of initial TMP is critical for optimizing RO operations, as it enables the development of robust modelling frameworks by accurately estimating membrane fouling trends, thereby enhancing process efficiency and long-term reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Ultra-filtration(UF) units are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square (RMSE) metric. Accurate prediction of initial TMP is critical for optimizing CCRO operations, as it enables the development of robust modelling frameworks that enhance process efficiency and reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION

Optimal Operation and Impact Assessment of Distributed Wind for Improving Efficiency and Resilience of Rural Electricity Systems

This project aims to empower rural utilities by developing advanced optimization models and algorithms for effectively integrating distributed wind energy alongside battery storage and other distributed energy resources (DERs). The primary objectives are to reduce peak demand, ensure reliable emergency power supply, and regulate voltage and frequency. To address operational challenges, the project introduces innovative mitigation strategies and ultrafast assessment frameworks to evaluate the impacts of distributed wind and DERs on rural grids, offering actionable solutions to potential issues. Economic viability is assessed through cost-benefit analysis using real rural utility data, ensuring the practical application of the project outcomes.

17 WIND ENERGY

Grid-Aware Charging and Operational Optimization for Mixed-Fleet Public Transit

The rapid growth of urban populations and the increasing need for sustainable transportation solutions have prompted a shift towards electric buses in public transit systems. However, the effective management of mixed fleets consisting of both electric and diesel buses poses significant operational challenges. One major challenge is coping with dynamic electricity pricing, where charging costs vary throughout the day. Transit agencies must optimize charging assignments in response to such dynamism while accounting for secondary considerations such as seating constraints. This paper presents a comprehensive mixed-integer linear programming (MILP) model to address these challenges by jointly optimizing charging schedules and trip assignments for mixed (electric and diesel bus) fleets while considering factors such as dynamic electricity pricing, vehicle capacity, and route constraints. We address the potential computational intractability of the MILP formulation, which can arise even with relatively small fleets, by employing a hierarchical approach tailored to the fleet composition. By using real-world data from the city of Chattanooga, Tennessee, USA, we show that our approach can result in significant savings in the operating costs of the mixed transit fleets.

Sen, Rishav

Operational optimization for multi-functional charging station with electric and hydrogen-powered vehicles

The rapid adoption of electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs), combined with global efforts to reduce carbon emissions, has accelerated the development of EV charging and hydrogen refueling stations. In response to this demand, this paper introduces the concept of Multi-Functional Charging Station (MFCS) that integrates power generation, EV charging, battery swapping, and hydrogen refueling. A comprehensive operational model is developed for the MFCS that couples electricity and hydrogen conversion and storage technologies to enhance infrastructure utilization and improve overall system efficiency. The model also considers multiple revenue streams, including participation in energy and ancillary markets. To validate the effectiveness of the proposed model and evaluate its performance, a series of numerical experiments are conducted with different charger numbers, different electricity purchase limits, and different charger allocations. Numerical results demonstrate that shared charger configurations can lead to 8.11 % improvement in operational profit by improving resource utilization and reducing the number of depleted batteries at the end of operations compared to allocated charger setups. By varying the number of chargers, sensitivity analysis identifies diminishing marginal returns beyond about 45 chargers, suggesting it as an optimal sizing point under current settings. The integration of electricity and hydrogen conversion is also explored under scenarios with limited external electricity purchases. In conclusion, these findings indicate that optimizing charger allocation and energy management can significantly enhance station productivity and profitability, ultimately supporting the broader adoption of electrified and hydrogen-based transportation solutions.

Charging station

Optimal Operation of Solid-Oxide Electrolysis Cell Systems Considering Synergistic Chemical and Physical Degradation

This poster summarizes work on synergistic degradation of Solid-Oxide Cells under physical and chemical degradation. We present operational insights that extend the useful life of SOCs while maintaining high efficiencies and economic viability. We also provide insights on how often the SOC must be replaced to ensure the reliability of the process. All these decisions are made through a dynamic optimization framework that utilizes new models for degradation that were developed as a part of the IDAES project.

Giridhar, Nishant

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION

Optimal Operation of Residential High Performance Water Heater for Reduction of Electricity Cost and Peak Demand Through Field Validation

Water heating accounts for about 18% of a typical US home’s energy use. Modern water heaters have enabled control options through APIs, offering customers the opportunity to reduce their energy cost and peak demand by dynamically adjusting settings. A water heater’s capacity to store energy using its storage tank makes it an asset for peak demand reduction and energy cost savings. For this reason, a mixed-integer linear programming model is proposed to minimize the energy cost of a high-performance water heater while also reducing the peak demand of the residential household under a time-of-use utility rate by dynamically changing the water heater’s running mode. Specifically, a multi-objective optimization model is formulated to determine the mode settings of the water heater considering hot water use, time-of-use rate, and peak demand limit of the residential household. The mode settings are associated with different dead bands of water temperature for triggering on/off action of the heat pump and heating element. A 66-gal hybrid electric high performance water heater was used for numerical simulation and practical experiments. The simulation results were well aligned with measurements of practical experiments, validating the soundness of the thermodynamic model. In addition, reductions of energy cost, enabling affordability, and reducing peak demand are demonstrated. The research team also developed a software framework with dashboards to automatically and continuously monitor and manage devices.

Liu, Guodong [ORNL] (ORCID:0000000213498608)

Machine Learning-Based Technique for Automated Sensor Characterization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert s time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Zepeda, Cuevas [Chicago U., KICP]

Optimizing Desalination Operations for Energy Flexibility

Despite the value of energy optimization in desalination processes, modeling dynamic operations for monthly billing periods has remained a computational challenge. This work proposes a framework for energy flexibility optimization, which includes new modeling features for independent operation of parallel skids, start-up delays associated with chemical stabilization, the consideration of industrial energy tariff structures, and inclusion of hourly electrical carbon intensities. This is done using a modular and computationally efficient formulation that guarantees a globally optimal solution with standard optimization solvers. In this study, the approach is demonstrated in two distinct case studies: a seawater desalination plant in Santa Barbara, CA, and an indirect potable reuse facility in San Jose, CA. Trends predicted from the model are validated against operational facility measurements from a demand response shutdown event. Preliminary results show that optimizing energy flexibility can result in 18.51% monthly cost savings over energy efficiency-optimized operation. The value extracted from a facility-wide shutdown during peak electricity price hours is hampered by start-up delays in post-treatment chemical stabilization. In cases in which a facility does not have much excess capacity, using a flow equalization tank or operating over a wide recovery range may be cost-effective.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

OPER: Optimality-Guided Embedding Table Parallelization for Large-scale Recommendation Model

With the sharp increasing volume of user data, Deep Learning Recommendation Model (DLRM) becomes an indispensable infrastructure in large technology companies. However, large-scale DLRM on the multi-GPU platform is still inefficient due to unbalanced workload partitioning and intensive inter-GPU communication. To this end, we propose OPER, an OPtimality guided Embedding table placement for large-scale Recommendation model training and inference. OPER explores the potential of mitigating remote memory access latency in DLRM through fine-grained embedding table placement. Specifically, OPER proposes a theoretical modeling that builds up the relationship between EMT placement and the embedding communication latency in both training and inference. OPER proves the NP hardness of finding the optimal embedding table placement and proposes a heuristic algorithm that yields near optimal placement. OPER implements a SHMEM-based embedding table training system and a unified embedding index mapping to support fine-grained embedding table sharding and placement. Comprehensive experiments reveal that OPER achieves on average 3.4× and 5.1× speedup on training and inference respectively over state-of-the-art DLRM frameworks.

Wang, Zheng