Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ORGANIC HALOGEN COMPOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synthesis and characterization of the La{sub 1-x}Sr{sub x}FeO{sub 3-{delta}} system and the fluorinated phases La{sub 1-x}Sr{sub x}FeO{sub 3-x}F{sub x}

The oxyfluorides La{sub 1-x}Sr{sub x}FeO{sub 3-x}F{sub x} have been prepared by fluorination of the precursor oxides La{sub 1-x}Sr{sub x}FeO{sub 3-{delta}} via a low temperature route using poly(vinylidene fluoride) (PVDF). The structures of the oxides and oxyfluorides were investigated in detail by the Rietveld analysis of powder diffraction data. The oxyfluorides crystallize in the space group Pnma for 0<x{<=}0.9 (SrFeO{sub 2}F itself is cubic, space group Pm-3m) and show a sort of two-step structural distortion for decreasing x. Furthermore, a structural comparison of the oxyfluorides with the oxides is given, revealing an increase of the volume per La{sub 1-x}Sr{sub x}FeX{sub 3} unit during fluorination, of which the magnitude highly depends on the value of x. - Graphical abstract: The crystal structures of the perovskites La{sub 1-x}Sr{sub x}FeO{sub 3-x}F{sub x} for x=0.8 (a), 0.5 (b) and 0.1 (c). Highlights: > Oxyfluorides La{sub 1-x}Sr{sub x}FeO{sub 3-x}F{sub x} were prepared via low temperature fluorination using PVDF. > A structural investigation of the compounds La{sub 1-x}Sr{sub x}FeO{sub 3-x}F{sub x} is presented in detail. > Differences in structure are discussed in comparison with the precursor oxides La{sub 1-x}Sr{sub x}FeO{sub 3-{delta}}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stabilization of positive charge on polytetrafluoroethylene electret films treated with titanium-tetrachloride vapor

The surface of polytetrafluoroethylene films was treated with titanium-tetrachloride vapor. The treatment was carried out in a flow reactor by means of molecular-layer deposition, a method from the arsenal of chemical nanotechnology. X-ray photoelectron spectroscopy reveals that such a treatment results in considerable changes in the chemical composition at and near the surface of the fluoropolymer film. Both, defluorination and oxidation of the surface were observed. At the same time, samples treated with titanium tetrachloride show a significant enhancement in the thermal stability of the positive homocharge. The thermally stimulated surface-potential-decay curves were observed to shift to higher temperatures by more than 100 deg. C

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AngioJet Thrombectomy for Occluded Dialysis Fistulae: Outcome Data

This study evaluates AngioJet thrombectomy of occluded autogenous dialysis fistulae and polytetrafluoroethylene (PTFE) grafts in a UK hemodialysis population. Comparison is made with published data of alternative percutaneous thrombectomy methods. All patients with occluded dialysis fistulae who sought care at the Royal Liverpool University Hospital between October 2006 and June 2008 were included in the study. All patients were treated with the AngioJet Rheolytic Thrombectomy Device (Possis, Minneapolis, MN). Demographics, time of occlusion, adjunctive therapies, complications, and follow-up data have been prospectively recorded. A total of 64 thrombectomy procedures were performed in 48 patients. Forty-four autogenous fistulas were treated in 34 patients (19 brachiocephalic, 8 radiocephalic, and 7 transposed brachiobasilic). Twenty PTFE grafts were treated in 14 patients (9 brachioaxillary, 3 brachiocephalic loop grafts, 1 brachiobasilic, and 1 femoro-femoral). The average length of occlusion was 24 cm. Average time to intervention was 4 days. Immediate primary patency was 91%. Primary patency at 1, 3, and 6 months, respectively, was 71%, 60%, and 37%. Secondary patency at 3, 6, and 12 months was 87%, 77%, and 62%, respectively. Angioplasty was carried out in all procedures. Patients required stent insertion in 34 of the 64 thrombectomies to treat angioplasty-resistant stenoses. Complications included a puncture-site hematoma, and three angioplasty-related vein ruptures in one patient, all treated with covered stent grafts. Two cases of distal brachial arterial embolization were successfully treated by thrombosuction. AngioJet thrombectomy in dialysis access occlusion is safe and effective, comparing favorably with other methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas

Purpose: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. Materials and Methods: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa{sup Registered-Sign}, Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. Results: Mean follow-up time was 97 weeks (range 4-270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. Conclusions: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility study of the separation of chlorinated films from plastic packaging wastes

This study describes the possible separation of chlorinated plastic films (PVC and PVDC) from other heavy plastic packaging waste (PPW) by selective twist formation and gravity separation. Twists formation was mechanically induced in chlorinated plastic films, whereas twist formation did not occur in PS and PET films. After twist formation, all the films had the apparent density of less than 1.0 g/cm{sup 3} and floated in water even though the true density was more than 1.0 g/cm{sup 3}. However, the apparent density of the PS and the PET films increased with agitation to more than 1.0 g/cm{sup 3}, whereas that of chlorinated plastic films was kept less than 1.0 g/cm{sup 3}. The main reason would be the air being held inside the chlorinated plastic films which was difficult to be removed by agitation. Simple gravity separation after twist formation was applied for artificial film with 10 wt.% of the chlorinated films and real PPW films with 9 wt.% of the chlorinated films. About 76 wt.% of the artificial PPW films and 75 wt.% of real PPW films after the removal of PP and PE were recovered as settling fraction with 4.7 wt.% and 3.0 wt.% of chlorinated plastic films, respectively. These results indicate that simple gravity separation process after twist formation can be used to reduce the chlorinated plastic concentration from mixed heavy PPW films.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of substrate roughness on the apparent surface free energy of sputter deposited superhydrophobic polytetrafluoroethylene coatings: A comparison of experimental data with different theoretical models

We have studied the effect of substrate roughness on the wettability and the apparent surface free energy (SFE) of sputter deposited polytetrafluoroethylene (PTFE) coatings deposited on untreated glass (average roughness, R{sub a}=2.0 nm), plasma etched glass (R{sub a}=7.4 nm), and sandblasted glass (R{sub a}=4500 nm) substrates. The wettability of the PTFE coatings deposited on substrates with varying roughnesses was evaluated by measuring the apparent contact angle (CA) using a series of probe liquids from nonpolar aprotic to polar protic. The wettability measurements indicate that an apparent water CA of 152 deg. with a sliding angle of 8 deg. was achieved for PTFE coatings deposited on a substrate with R{sub a}=4500 nm. The superhydrophobicity observed in these coatings is attributed to the presence of dual scale roughness, densely packed microstructure and the presence of CF{sub 3} groups. Unlike the bulk PTFE which is mainly dispersive, the sputter deposited PTFE coatings are expected to have some degree of polar component due to the plasma treatment. In order to calculate the dispersive SFE of PTFE coatings, we have used the Girifalco-Good-Fowkes (GGF) method and validated it with the Zisman model. Furthermore, the Owens-Wendt model has been used to calculate the dispersive and the polar components of the apparent SFE of the PTFE coatings. These results are further corroborated using the Fowkes method. Finally, an ''equation of state'' theory proposed by Neumann has been used to calculate the apparent SFE values of the PTFE coatings. The results indicate that the apparent SFE values of the PTFE coatings obtained from the Owens-Wendt and the Fowkes methods are comparable to those obtained from the Neumann's method. The analyses further demonstrate that the GGF and the Zisman methods underestimate the apparent SFE values of the sputter deposited PTFE coatings.

36 MATERIALS SCIENCE↗

Low temperature fluorination of Sr{sub 3}Fe{sub 2}O{sub 7-x} with polyvinylidine fluoride: An X-ray powder diffraction and Moessbauer spectroscopy study

Fluorination of the Ruddlesden Popper phase, Sr{sub 3}Fe{sub 2}O{sub 7-x} by heat treatment with polyvinylidine fluoride (PVDF) gives a range of novel oxide fluoride compounds. Fluorination with 1 mol equivalent PVDF leads to a filling of the normal Ruddlesden Popper structure anion sites and a material of composition Sr{sub 3}Fe{sub 2}O{sub 5+x}F{sub 2-x} (x Almost-Equal-To 0.28(4)) which contains both Fe{sup 4+} and Fe{sup 3+}. Increasing the amount of PVDF to 2 mol equivalent leads to an increase in anion content due to filling of half the interstitial sites within the structure, with iron being completely reduced to Fe{sup 3+} leading to a composition Sr{sub 3}Fe{sub 2}O{sub 4}F{sub 4}. An increase in the amount of PVDF to Almost-Equal-To 3 mol equivalent leads to a further increase in unit cell volume, attributed to complete filling of the interstitial sites and a composition Sr{sub 3}Fe{sub 2}O{sub 3}F{sub 6}. {sup 57}Fe Moessbauer spectra in the temperature range 10-300 K demonstrated the complexity of the magnetic interactions in each of the three phases which reflect different local compositions of oxygen and fluorine around the iron ions thus influencing the superexchange pathways. - Graphical abstract: Low temperature (375 Degree-Sign C) fluorination of Sr{sub 3}Fe{sub 2}O{sub 7-x} with poly(vinylidene fluoride) leads to the production of three new Ruddlesden Popper oxide fluorides with progressive filling of the anion sites within the structure. Highlights: Black-Right-Pointing-Pointer The fluorination of Sr{sub 3}Fe{sub 2}O{sub 7-x} using PVDF. Black-Right-Pointing-Pointer The control of the fluorine content with amount of PVDF used. Black-Right-Pointing-Pointer The synthesis of three new Fe based oxide fluorides. Black-Right-Pointing-Pointer The identification of the structures of these oxide fluorides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extended model of the photoinitiation mechanisms in photopolymer materials

In order to further improve photopolymer materials for applications such as data storage, a deeper understanding of the photochemical mechanisms which are present during the formation of holographic gratings has become ever more crucial. This is especially true of the photoinitiation processes, since holographic data storage requires multiple sequential short exposures. Previously, models describing the temporal variation in the photosensitizer (dye) concentration as a function of exposure have been presented and applied to two different types of photosensitizer, i.e., Methylene Blue and Erythrosine B, in a polyvinyl alcohol/acrylamide based photopolymer. These models include the effects of photosensitizer recovery and bleaching under certain limiting conditions. In this paper, based on a detailed study of the photochemical reactions, the previous models are further developed to more physically represent these effects. This enables a more accurate description of the time varying dye absorption, recovery, and bleaching, and therefore of the generation of primary radicals in photopolymers containing such dyes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Ischemic Model Using a Radiofrequency Wire Electrode in a Rabbit Hindlimb

The purpose of this study was to establish an ischemic rabbit hindlimb model using a radiofrequency (RF) wire electrode. We inserted a polytetrafluoroethylene-coated wire with a 2-cm exposed tip into the left superficial femoral artery of seven New Zealand white rabbits and performed RF ablation (RFA) while pulling the wire back. We assessed the clinical findings, angiography, computed tomography perfusion, and permeability surface until 6 weeks after RFA. The angiography demonstrated complete obstruction from the proximal external iliac artery to the distal superficial femoral artery and showed a gradual increment in the angiogenic score, which represents the degree of angiogenesis (r = 0.86, p < 0.0001). The left-to-right ratios of the computed tomography perfusion and permeability surface were significantly reduced after 4 days (p < 0.05), and then they gradually increased with time. We conclude that endovascular RFA using an RF wire electrode is a reproducible and measurable way to create an ischemic rabbit hindlimb model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double-Layered PTFE-Covered Nitinol Stents: Experience in 32 Patients with Malignant Esophageal Strictures

We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. After stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9-348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent's migration rate.

36 MATERIALS SCIENCE↗

Pull-Through Technique for Recanalization of Occluded Portosystemic Shunts (TIPS): Technical Note and Review of the Literature

Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of the TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Separation of packaging plastics by froth flotation in a continuous pilot plant

The objective of the research was to apply froth flotation to separate post-consumer PET (Polyethylene Terephthalate) from other packaging plastics with similar density, in a continuously operated pilot plant. A representative sample composed of 85% PET, 2.5% PVC (Polyvinyl Chloride) and 11.9% PS (Polystyrene) was subjected to a combination of alkaline treatment and surfactant adsorption followed by froth flotation. A mineral processing pilot plant, owned by a Portuguese mining company, was adapted for this purpose. The experimentation showed that it is possible to produce an almost pure concentrate of PET, containing 83% of the PET in feed, in a single bank of mechanical flotation cells. The concentrate grade attained was 97.2% PET, 1.1% PVC and 1.1% PS. By simulation it was shown that the Portuguese recycling industry specifications can be attained if one cleaning and one scavenger stages are added to the circuit.

07 ISOTOPE AND RADIATION SOURCES↗

Electronic Structure and Gas-Phase Behaviour of the Heaviest Elements

Electronic structures and gas-phase adsorption behaviour of the heaviest elements 112, 113 and 114 and of their lighter homologs Hg, Tl and Pb is studied on the basis of ab initio Dirac-Coulomb atomic and four-component Density Functional Theory molecular and cluster calculations. The heaviest elements were shown to have low adsorption enthalpies on Teflon and should, therefore, be well transported through Teflon capillaries from the target chamber to the chemistry set up. Adsorption enthalpies of these elements on the Au(111) surface are predicted as -44.5 kJ/mol, -158.6 kJ/mol and -68.5 kJ/mol, respectively, giving the following sequence in the adsorption temperatures 113>114>112.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of the Viatorr Expanded Polytetrafluoroethylene-Covered Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Creation in Children: Initial Clinical Experience

Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent until the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of PTFE Stent Grafts for Hemodialysis-related Central Venous Occlusions: Intermediate-Term Results

Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14), and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent graft demonstrates encouraging intermediate-term patency results for central vein occlusions. Further prospective studies with long-term assessment and larger patient populations will be required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of external metabolizing systems when testing for endocrine disruption in the T-screen assay

Although, it is well-established that information on the metabolism of a substance is important in the evaluation of its toxic potential, there is limited experience with incorporating metabolic aspects into in vitro tests for endocrine disrupters. The aim of the current study was a) to study different in vitro systems for biotransformation of ten known endocrine disrupting chemicals (EDs): five azole fungicides, three parabens and 2 phthalates, b) to determine possible changes in the ability of the EDs to bind and activate the thyroid receptor (TR) in the in vitro T-screen assay after biotransformation and c) to investigate the endogenous metabolic capacity of the GH3 cells, the cell line used in the T-screen assay, which is a proliferation assay used for the in vitro detection of agonistic and antagonistic properties of compounds at the level of the TR. The two in vitro metabolizing systems tested the human liver S9 mix and the PCB-induced rat microsomes gave an almost complete metabolic transformation of the tested parabens and phthalates. No marked difference the effects in the T-screen assay was observed between the parent compounds and the effects of the tested metabolic extracts. The GH3 cells themselves significantly metabolized the two tested phthalates dimethyl phthalate (DMP) and diethyl phthalate (DEP). Overall the results and qualitative data from the current study show that an in vitro metabolizing system using liver S9 or microsomes could be a convenient method for the incorporation of metabolic and toxicokinetic aspects into in vitro testing for endocrine disrupting effects.

60 APPLIED LIFE SCIENCES↗