Engineering PapersSearch

SEARCH · Engineering Papers

Results for “OPTICAL FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

When do molecular polaritons behave like optical filters?

This review outlines several linear optical effects featured by molecular polaritons arising in the collective strong light–matter coupling regime. Under weak laser irradiation and when the single-molecule light–matter coupling can be neglected (often in the limit when the number of molecules per photon mode is large), we show that the excited-state molecular dynamics under collective strong coupling can be exactly replicated without the cavity using a shaped (or “filtered”) laser, whose field amplitude is enhanced by the cavity quality factor, shining on the bare molecules. As a consequence, the absorption within a cavity can be understood as the overlap between the polariton transmission and the bare molecular absorption, suggesting that polaritons act in part as optical filters. This framework demystifies and provides a straightforward explanation for a large class of experiments and theoretical models in molecular polaritonics, highlighting that the same effects can be achieved without the cavity with shaped laser pulses. With a few modifications, this simple conceptual picture can also be adapted to understand the incoherent nonlinear response of polaritonic systems. This review establishes a clear distinction between polaritonic phenomena that can be fully explained through classical linear optics and those that require a quantum electrodynamics approach. It also highlights the need to differentiate between effects that necessitate polaritons (i.e., hybrid light–matter states) and those that can occur in the weak coupling regime. Here, we further discuss that certain quantum optical effects like fluorescence can be partially described as optical filtering, whereas some others like cavity-induced Raman scattering go beyond this. Further exploration in these areas is needed to uncover novel polaritonic phenomena beyond optical filtering.

Schwennicke, Kai [University of California, San Di

Enhancing lifetime, forecasting, and economic benefits of photovoltaic technologies undergoing UV-induced degradation with optical filtering

Ultraviolet-induced degradation (UV-ID) of various PV cell types was analyzed under optical UV filters with different cutoff wavelengths. Cell types studied included interdigitated back contact (IBC), passivated emitter and rear totally diffused (PERT), and heterojunction technology (HJT) based on crystalline Si (c-Si), and metal halide perovskite (MHP) cells. Analyzing degradation rates in two distinct regimes proved beneficial for all cell types. We used empirical linearizing functions ln(t) for c-Si technologies and 2 √t for MHP samples where t is time. These were applied to extrapolate UV-induced degradation over the lifetime of PV modules under various levels of optical UV filtering and used to predict the relative economic benefits for PV power plants. Degradation rates for all technologies were generally faster under the long pass optical filters having shorter cutoff wavelengths transmitting more UV irradiation and at elevated temperatures when testing MHP samples in the range between 60 °C and 90 °C.

14 SOLAR ENERGY

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy

Enhancing Thomson scattering polychromator performance with multi-pass spectral filters

In photon-deficient, noncollective Thomson scattering diagnostics, filter polychromators are typically employed in the spectral analysis of Thomson-scattered signals to achieve acceptable signal-to-noise performance. Currently, the most common polychromator filter configuration employs a set of single-passband optical filters that define individual spectral channels. Here, we introduce a new spectral analysis method for Thomson scattering based on spectral filters with multiple passbands, referred to as Thomson scattering spectral multiplexing. Implementing multi-bandpass spectral filters on polychromators increases the achievable range of electron temperature measurement for a given number of filters employed. In addition, Thomson scattering spectral multiplexing reduces systematic measurement uncertainty, with fewer required spectral channels, thereby decreasing light loss from reduced optical element interactions. A multi-bandpass filter set, optimized by a genetic algorithm, has been successfully installed and tested on the Helically Symmetric eXperiment (HSX), demonstrating the benefits of the Thomson scattering spectral multiplexing method.

Instruments & Instrumentation

A near X-point charge exchange neutral spectroscopy (CENS) system for DIII-D

A 16 channel spectroscopy system has been installed on DIII-D to provide information about the energy distribution of the atomic neutrals using the Doppler shift and broadening of passive Balmer-α emission. Here, the lines of sight are dominantly in the toroidal direction, with tangencies near the lowest point on closed magnetic flux surfaces moving from the lower divertor upward into the confined plasma. This allows the system to provide details of the neutrals as they undergo various atomic physics processes while traveling upward from the lower divertor. The spectrally resolved measurements provide several advantages that complement typical optical filter based measurements of hydrogenic spectral lines. These include more direct measurements of the neutrals that fuel deeper in the plasma and capturing neutral velocity distribution information via the Doppler broadened and shifted line. In addition, the spectral separation of higher energy “thermal” neutrals and bright cold emission from the scrape-off layer allows for a more straightforward calculation of the underlying neutral densities based on the emission because of the dependence of the thermal emission on confined plasma properties that are approximately flux functions and well measured.

Atomic and molecular physics

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve

CMOS-fabricated ultraviolet light modulator using low-loss alumina piezo-optomechanical photonics

Ultra-violet (UV) and near-UV wavelengths are necessary for many important optical transitions for quantum technologies and various sensing mechanisms for biological and chemical detection. However, all well-known photonic platforms have excessively high losses in the UV, which has prevented photonic integrated circuits (PICs) being used to address these and other important application spaces. Photonic waveguides using low-loss alumina cores and silicon dioxide cladding have emerged as a promising solution because of alumina’s large optical bandgap and the high quality of films enabled by atomic layer deposition. These properties allow passive, low-loss waveguide operation down to at least 266 nm using multimode widths. However, to the best of our knowledge, active alumina PICs have only been realized using thermo-optic tuning, which precludes switching speeds shorter than approximately 100 microseconds, high circuit densities, and cryogenically compatible operation. Here, we introduce a CMOS-fabricated, piezo-optomechanical PIC platform using alumina waveguides and piezoelectric aluminum nitride strain actuators. The platform allows for sub-microsecond switching times, high circuit densities, and cryogenic operation which is desired in many UV PIC applications. We demonstrate a high-performance, reconfigurable optical filter operating at wavelengths as low as 320 nm. The filter has a 6-nanosecond switching time, a loaded linewidth of 3.3 GHz, tuning rate of 28 V/linewidth, and a hold power of less than 20 nW at one linewidth detuning. This work establishes the foundations for a new class of CMOS-fabricated, rapidly reconfigurable, and low-power UV photonic circuits compatible with wavelengths as low as 225 nm.

Castillo, Zachary A. [Sandia National Laboratories

Optical Fiber Sensor with a Hydrophobic Filter Layer for Monitoring Hydrogen under Humid Conditions

Real-time and remote monitoring of hydrogen concentration in underground hydrogen storage reservoirs is crucial to maintaining the integrity and safety of the storage facilities. High humidity in the underground deposits interferes with hydrogen sensors, introducing inaccuracy into the hydrogen sensing measurements. A hydrophobic filter layer over a hydrogen sensing layer on an optical fiber hydrogen sensor was devised to minimize the impact of the humidity on the sensor. The hydrogen sensor coated with a hydrophobic filter layer demonstrated a significant improvement in reliable hydrogen sensing under high humidity conditions (99% RH) without severe baseline drift and reduction of transmission intensity. Finally, the optical fiber hydrogen sensor revamped with the filter layer would enable the reliable measurement of hydrogen concentration under the humid conditions expected in subsurface hydrogen storage facilities.

08 HYDROGEN

GQuEST Control System Resolution

GQuEST (Gravity from Quantum Entanglement of Space-Time), is a collaboration verifying a quantum gravity model by measuring holographic effects on a microscopic scale. Its interferometer apparatus filters excessive optical noise and requires a control system that can adjust the filtration to accommodate for frequency changes in the output light. We stress-test this control system by simulating filter behaviors with parameters in their outermost regimes, and we have determined a threshold that maintains precision while minimizing resource usage. These results are important for the successful operation of GQuEST's interferometer, enabling more accurate tests of quantum gravity models and thereby advancing our understanding of gravity at the quantum mechanical level.

Nguyen, David

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION

The LSST Camera (LSSTCam)

The LSST Camera is the sole instrument for the NSF-DOE Vera C. Rubin Observatory and consists of a 3.2 gigapixel focal plane mosaic with in-vacuum controllers, dedicated guider and wavefront CCDs, a three-element corrector whose largest lens is 1.55m in diameter, six optical interference filters covering a 320-1050nm band pass with an out-of-plane filter exchange mechanism, and camera slow control and data acquisition systems capable of digitizing each image in 2 seconds.

79 ASTRONOMY AND ASTROPHYSICS

Evaluation of a catalytically aided thermal regeneration method for quartz filter-based black carbon sensing

Black carbon (BC)–a strong indicator of diesel particulate matter and other sources of incomplete carbonaceous fuel combustion–is an important air pollutant that affects public health, yet low-cost sensors capable of long-term, autonomous BC monitoring remain underdeveloped. We report on the development and evaluation of a novel BC prototype sensor that integrates soot collection on a quartz filter, in-situ optical transmission measurement, and thermal filter regeneration. To enable regeneration at lower temperatures, we evaluated the catalytic effects of various alkali metal salts pre-applied to the filter. Among these, cesium carbonate (Cs 2 CO 3 ) exhibited the strongest catalytic activity, lowering the temperature required for complete BC removal by up to 190 °C and reducing energy consumption by more than 75% compared to that required for untreated filters. The catalytic effect persisted through 10 BC collection–regeneration cycles. These findings demonstrate the potential of catalytically aided thermal regeneration in BC sensors and suggest a pathway toward energy-efficient and reduced maintenance air quality monitoring suitable for distributed BC monitoring networks.

Tang, Xiaochen [Lawrence Berkeley National Laborat

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI

Constraints on the normal branch of DGP gravity from SPT galaxy clusters with DES and HST weak-lensing mass calibration and from P l a n c k PR4 CMB anisotropies

We present constraints on the normal branch of the Dvali-Gabadadze-Porrati (nDGP) braneworld gravity model from the abundance of massive galaxy clusters. On scales below the nDGP crossover scale r c , the nDGP model features an effective gravitylike fifth force that alters the growth of structure, leading to an enhancement of the halo mass function (HMF) on cluster scales. The enhanced cluster abundance allows for constraints on the nDGP model using cluster samples. We employ the South Pole Telescope (SPT) cluster sample, selected through the thermal Sunyaev-Zel’dovich effect with the SPT and with mass calibration using weak-lensing data from the Dark Energy Survey (DES) and the Hubble Space Telescope (HST). The cluster sample contains 1,005 clusters with redshifts 0.25 < z < 1.78 , which are confirmed with the multicomponent matched filter algorithm using optical and near-infrared data. Weak-lensing data from DES and HST enable a robust mass measurement of the cluster sample. We use DES Year 3 data for 688 clusters with redshifts z < 0.95 , and HST data for 39 clusters with redshifts 0.6 < z < 1.7 . We account for the enhancement in the HMF through a semi-analytic correction factor to the standard cosmology HMF derived from the spherical collapse model in the nDGP model. We then further calibrate this model using N -body simulations. In addition, for the first time, we analyze the primary CMB temperature and polarization anisotropy measurements from Planck PR4 within the nDGP model. We obtain a competitive constraint from the joint analysis of the SPT cluster abundance with the Planck PR4 data, and report an upper bound of 1 / H 0 r c < 1.41 at 95% when assuming a cosmology with massive neutrinos.

Vogt, S. M.L. [Munich U. Observ.; LMU Munich (main

High power chip-scale laser

The lack of high-power integrated lasers has been limiting silicon photonics. Despite much progress in chip-scale laser integration, power output remains below levels required for key applications due to low energy efficiency at high pumping currents. Here we break this power limitation by coupling a broad-area multimode gain chip to a silicon-nitride ring resonator and single-mode filter. The resulting optical feedback causes the multimode-gain chip to concentrate its power into a single highly coherent mode. Our device produces more than 150 mW of power and 400 kHz linewidth. We achieve these metrics while maintaining a small footprint of 3 mm 2 .

Antman, Yair