Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ODOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NASA Animal Enclosure Module Mouse Odor Containment Study for STS-107 September 15, 1999;SJSU Odor Panel Data

Experiment #153 by Scott Brady is manifested for shuttle flight STS-107. This evaluation of space flight induced stress and its effects on neuronal plasticity will use 18 six month old C57Bl/6 male mice. A 21 day evaluation study was proposed to determine the length of time groups of 6, 9, or 12 mice could be housed in the Animal Enclosure Module (AEM) without odor breakthrough. This study was performed at NASA-Ames Research Center beginning on September 15, 1999. NASA personnel, were responsible for animal care, maintenance, facilities, hardware, etc. San Jose State personnel performed the odor panel evaluations and data reduction. We used similar procedures and methods for earlier tests evaluating female mice.

Holley, Daniel C.↗

Elaborated Odor Test for Extended Exposure

Concerns were raised when incidental exposure to a proprietary bonding material revealed the material had an irritating odor. The NASA-STD-6001B document describes a supplemental test method option for programs to evaluate materials with odor concerns (Test 6, Odor Assessment). In addition to the supplemental standard odor assessment with less than 10 seconds of exposure, the NASA White Sands Test Facility (WSTF) Materials Flight Acceptance Testing section was requested to perform an odor test with an extended duration to evaluate effects of an extended exposure and to more closely simulate realistic exposure scenarios. With approval from the NASA Johnson Space Center Industrial Hygienist, WSTF developed a 15-minute odor test method. WSTF performed this extended-duration odor test to evaluate the odor and physical effects of the bonding material configured between two aluminum plates, after the safety of the gas was verified via toxicity analysis per NASA-STD-6001B Test 7, Determination of Offgassed Products. During extended-duration testing, odor panel members were arranged near the test material in a small room with the air handlers and doors closed to minimize dilution. The odor panel members wafted gas toward themselves and recorded their individual assessments of odor and physical effects at various intervals during the 15-minute exposure and posttest. A posttest interview was conducted to obtain further information. Testing was effective in providing data for comparison and selection of an optimal offgassing and odor containment configuration. The developed test method for extended exposure is proposed as a useful tool for further evaluating materials with identified odors of concern if continued use of the material is anticipated.

Buchanan, Vanessa D.↗

Sampling Technique for Robust Odorant Detection Based on MIT RealNose Data

This technique enhances the detection capability of the autonomous Real-Nose system from MIT to detect odorants and their concentrations in noisy and transient environments. The lowcost, portable system with low power consumption will operate at high speed and is suited for unmanned and remotely operated long-life applications. A deterministic mathematical model was developed to detect odorants and calculate their concentration in noisy environments. Real data from MIT's NanoNose was examined, from which a signal conditioning technique was proposed to enable robust odorant detection for the RealNose system. Its sensitivity can reach to sub-part-per-billion (sub-ppb). A Space Invariant Independent Component Analysis (SPICA) algorithm was developed to deal with non-linear mixing that is an over-complete case, and it is used as a preprocessing step to recover the original odorant sources for detection. This approach, combined with the Cascade Error Projection (CEP) Neural Network algorithm, was used to perform odorant identification. Signal conditioning is used to identify potential processing windows to enable robust detection for autonomous systems. So far, the software has been developed and evaluated with current data sets provided by the MIT team. However, continuous data streams are made available where even the occurrence of a new odorant is unannounced and needs to be noticed by the system autonomously before its unambiguous detection. The challenge for the software is to be able to separate the potential valid signal from the odorant and from the noisy transition region when the odorant is just introduced.

Duong, Tuan A.↗

History of NASA’s Odor Assessment (Test 6)

NASA's Odor Assessment (Test 6) for nonmetallic materials and assembled articles for spacecraft has evolved since the Apollo program in 1966 to meet various habitable spacecraft nonmetallic programmatic requirements. The purpose of Test 6 is to determine if the odor from a material or assembled article is objectionable or revolting on an odor-characteristic scale of 0 to 4. Samples of the toxicity-screened test atmosphere from a conditioned specimen container are administered to an Odor Panel of qualified human research subject volunteers using a syringe and mask, and are assigned a scored odor characteristic of undetectable (0), barely detectable (1), easily detectable (2), objectionable (3), or revolting (4). The odor from a material or assembled article is objectionable or revolting if an average rating of 2.5 or higher is assigned by an Odor Panel. This manuscript presents the history of Test 6, beginning with the Apollo spacecraft nonmetallic materials selection guidelines and test requirements from 1966, in which tests were performed in oxygen atmospheres, and follows the odor test through Skylab, Space Shuttle, International Space Station, and Orion nonmetals testing, and acceptance requirements.

Benjamin Greene↗

Odor test

To prevent the use of spacecraft material that would outgas objectionable or nauseating odors, an odor test was developed. This test provided a means whereby candidate spacecraft materials were subjected to a particular environment and the outgassed products were evaluated by an odor panel. This panel was comprised of individuals with acute olfactory senses. The test results of the odor panel provided design engineers with data regarding potential material-odor problems. The odor-test procedure, panel-member selection, and odor scoring methods are described and typical test results are presented.

Schluter, L. A.↗

Odor intensity and characterization of jet exhaust and chemical analytical measurements

Odor and chemical analyses were carried out on the exhaust samples from a J-57 combustor can operated over a range of inlet conditions, and with several fuel types and nozzle modifications. The odor characteristics and total intensity of odor for each exhaust were determined over a range of dilutions to allow for a least squares determination of the intensity at 1,000 to 1 dilutions. Analytical measures included the concentration of total hydrocarbons and the concentrations of aromatic organic species and oxygenated organic species from collected samples which were taken concurrently. A correlation was found between the concentration of the odorous oxygenated fraction and the total intensity of aroma. Inlet operating conditions and nozzle modifications which increase the efficiency of combustion as measured by exhaust gas analyses reduce the odor intensity and the quantity of oxygenates in the exhaust. The type of fuel burned altered the intensity of odor in relation to the quantity of oxygenates produced and, in some instances, changed the odor character.

Kendall, D. A.↗

Proposed Objective Odor Control Test Methodology for Waste Containment

The Orion Cockpit Working Group has requested that an odor control testing methodology be proposed to evaluate the odor containment effectiveness of waste disposal bags to be flown on the Orion Crew Exploration Vehicle. As a standardized "odor containment" test does not appear to be a matter of record for the project, a new test method is being proposed. This method is based on existing test methods used in industrial hygiene for the evaluation of respirator fit in occupational settings, and takes into consideration peer reviewed documentation of human odor thresholds for standardized contaminates, industry stardnard atmostpheric testing methodologies, and established criteria for laboratory analysis. The proposed methodology is quantitative, though it can readily be complimented with a qualitative subjective assessment. Isoamyl acetate (IAA - also known at isopentyl acetate) is commonly used in respirator fit testing, and there are documented methodologies for both measuring its quantitative airborne concentrations. IAA is a clear, colorless liquid with a banana-like odor, documented detectable smell threshold for humans of 0.025 PPM, and a 15 PPB level of quantation limit.

Vos, Gordon↗

Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization

The purpose of this test is to evaluate the odor containment of the urine containment bag (UCB), P/N SDD46107234-306 in an environment simulating a spacecraft capsule. The goal is to determine the time of odor break through and the acceptability of the odor, once break through occurs. The goal is to simulate, as close as possible, the volume ratio (trash to free volume), trash content (vomit, urine, feces, and food trash), humidity and temperature of the capsule. The goal for minimum break through is 48 hours (Orion Block 0) from the start of the test. The goal for acceptability of odor is 2 weeks (including docked ISS time for Orion Block 0). Two UCB's will be tested simultaneously in different chambers. The one UCB will be tested empty, serving as a control. Odor break through will be based upon the when the filled UCB total organics exceeds that of the control (empty UCB) by a level detectable by a human panel (approximately 2 ppm).

Casper, Stephanie↗

Odor intensity and characterization studies of exhaust from a turbojet engine combustor

Sensory odor tests of the exhaust from a turbojet combustor operating at simulated idle conditions were made by a human panel sniffing diluted exhaust gas. Simultaneously, samples of undiluted exhaust gas were collected on adsorbent substrates, subsequently removed by solvent flushing, and analyzed chemically by liquid chromatographic methods. The concentrations of the principal malodorous species, the aromatic (unburned fuel-related) and the oxygenated (partially burned fuel) fractions, as determined chromatographically, correlated well with the intensity of the odor as determined by sniffing. Odor intensity increased as combustion efficiency decreased. Combustor modifications which increased combustion efficiency decreased odor intensity.

Butze, H. F.↗

Odor intensity and characterization studies of exhaust from a turbojet engine combustor

Sensory odor tests of the exhaust from a turbojet combustor operating at simulated idle conditions were made by a human panel sniffing diluted exhaust gas. Simultaneously, samples of undiluted exhaust gas were collected on adsorbent substrates, subsequently removed by solvent flushing, and analyzed chemically by liquid chromatographic methods. The concentrations of the principal malodorous species, the aromatic (unburned fuel-related) and the oxygenated (partially burned fuel) fractions, as determined chromatographically, correlated well with the intensity of the odor as determined by sniffing. Odor intensity increased as combustion efficiency decreased. Combustor modifications which increased combustion efficiency decreased odor intensity.

Butze, H. F.↗

Simulated microgravity [bed rest] has little influence on taste, odor or trigeminal sensitivity

Anecdotal evidence suggests that astronauts' perceptions of foods in space flight may differ from their perceptions of the same foods on Earth. Fluid shifts toward the head experienced in space may alter the astronauts' sensitivity to odors and tastes, producing altered perceptions. Our objective was to determine whether head-down bed rest, which produces similar fluid shifts, would produce changes in sensitivity to taste, odor or trigeminal sensations. Six subjects were rested three times prior to bed rest, three times during bed rest and two times after bed rest to determine their threshold sensitivity to the odors isoamylbutyrate and menthone, the tastants sucrose, sodium chloride, citric acid, quinine and monosodium glutamate, and to capsaicin. Thresholds were measured using a modified staircase procedure. Self-reported congestion was also recorded at each test time. Thresholds for monosodium glutamate where slightly higher during bed rest. None of the other thresholds were altered by bed rest.

NASA Center JSC↗

Flammability, Odor, Offgassing, and Compatibility Requirements and Test Procedures for Materials in Environments that Support Combustion

This handbook establishes NASA program requirements for evaluation, testing, and selection of materials to preclude unsafe conditions related to flammability, odor, offgassing, and fluid compatibility. Materials intended for use in space vehicles, specified test facilities, and specified ground support equipment (GSE) must meet the requirements of this document. Additional materials performance requirements may be specified in other program or NASA center specific documentation. Responsible NASA centers materials organizations must include applicable requirements of this document in their materials control programs. Materials used in habitable areas of spacecraft, including the materials of the spacecraft, stowed equipment, and experiments, must be evaluated for flammability, odor, and offgassing characteristics. All materials used in other areas must be evaluated for flammability characteristics. In addition, materials that are exposed to liquid oxygen (LOX), gaseous oxygen (GOX), and other reactive fluids' must be evaluated for compatibility with the fluid in their use application. Materials exposed to pressurized breathing gases also must be evaluated for odor and offgassing characteristics. The worst-case anticipated use environment (most hazardous pressure, temperature, material thickness, and fluid exposure conditions) must be used in the evaluation process. Materials that have been shown to meet the criteria of the required tests are acceptable for further consideration in design. Whenever possible, materials should be selected that have already been shown to meet the test criteria in the use environment. Existing test data are compiled in the NASA Marshall Space Flight Center (MSFC) Materials and Processes Technical Information System (MAPTIS) and published periodically as the latest revision of a joint document with Johnson Space Center (JSC), MSFC-HDBK-527/JSC 09604. MAPTIS can be accessed by computer datalink. Systems containing materials that have not been tested or do not meet the criteria of the required tests must be verified to be acceptable in the use configuration by analysis or testing. This verification rationale must be documented and submitted to the responsible NASA center materials organization for approval.

Source record↗

Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments

In a realistic odorant detection application environment, the collected sensory data is a mix of unknown chemicals with unknown concentrations and noise. The identification of the odorants among these mixtures is a challenge in data recognition. In addition, deriving their individual concentrations in the mix is also a challenge. A deterministic analytical model was developed to accurately identify odorants and calculate their concentrations in a mixture with noisy data.

Duong, Tuan A.↗

Odor Control Test Report of the Urine Containment Bag (UCB) for Orion Utilization

The purpose of this report is to summarize the conclusions for the odor control test of the Urine Containment Bag (UCB), P/N SDD46107234-306 in an environment simulating a space craft capsule. JSC 65891, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization, documents the test plan. The details of the test set-up and data reduction are detailed in the WSTF test report for this test WSTF #10-44500, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization,. This document outlines the project conclusions and forward plans with regard to trash containment for Constellation.

Casper, Stephanie↗

Investigating the Effects of Exposure to Blue-Enriched Light or Peppermint Odor on Alertness, Mood, and Performance Upon Awakening from Deep Sleep at Night

Introduction: Sleep inertia refers the transient neurobehavioral impairments experienced immediately after waking from sleep. This period of reduced alertness and performance poses a significant safety risk to on-call workers who may be required to perform a safety-critical task immediately after waking (e.g., emergency services, health care, and military). In these operations, the need for a rapid return to full alertness is critical to mission safety and success. Several factors may exacerbate sleep inertia, resulting in greater impairment upon waking, including: waking from deep sleep, (i.e., slow wave sleep, SWS), waking at night, and waking following prior sleep loss. Awakenings under these conditions are common for on-call and extended shift workers who may need to perform safety-critical tasks soon after waking from unprotected sleep opportunities. Therefore, there is a need for evidence-based reactive countermeasures (i.e., used upon waking) to the cognitive consequences sleep inertia. Specifically, countermeasures that can rapidly restore alertness and performance immediately following sleep. A recent review of the literature on reactive countermeasures highlighted several research gaps and promising candidates for further investigation. The review also emphasized the need for countermeasures that are operationally viable and readily deployed in occupational settings. This study aims to address the identified gaps and limitations by assessing the efficacy of exposure to two known acute alerting stimuli - blue-enriched light and peppermint odor - to improve cognitive performance, alertness, and mood immediately after waking from SWS at night. Materials and Methods: Twelve participants completed a two-week within-subject, randomized, cross-over intervention study including two in-laboratory overnight visits. During each experimental week, the subjects experienced one intervention (light or peppermint) and a control condition upon awakening from SWS at night. The presentation order of the two conditions (intervention or control) at wake-up and the order of intervention (light or peppermint) by week was randomized by sex. Prior to each in-laboratory visit, participants maintained a sleep schedule of 8.5 h for 5 nights and 5 h for one night. Compliance with this sleep schedule was confirmed by actigraphy. In the laboratory, participants went to bed at their habitual bedtime and were monitored by standard polysomnography. After at least five minutes of continuous SWS, participants were awoken and exposed, in a randomized order, to either the control or intervention condition. During the hour after awakening from SWS (at 2, 17, 32, and 47 minutes after waking), participants completed a battery of tasks including a 5-minute psychomotor vigilance task (PVT), a subjective scale of alertness (Karolinska Sleepiness Scale, KSS), and visual analogue scales (VAS) of mood. Following this sleep inertia measurement period, all lights were turned off and participants were allowed to return to sleep. They were then awoken again from their subsequent SWS period and exposed to the alternative condition (control or intervention). Following this second awakening, participants were allowed to sleep until their habitual wake time and were then released from the laboratory. Participants then followed the at-home sleep schedule and returned to the laboratory for the second intervention (light or peppermint) following the procedures described above. The light intervention involved exposure to a blue-enriched light canvas illuminated for 1 hour at a distance of ~56 cm from the participant (~200 lux and ~60 melanopic lux at angle of gaze). For the peppermint intervention, peppermint oil was pipetted onto a mask, and participants inhaled the odor with the mask covering the nose and mouth for 1 minute. The control condition for both weeks involved a dim, red ambient light (<1 lux). An odorless mask, without any oil pipetted onto the mask, was also worn in the peppermint control condition. Results: Compared to the control condition, participants exposed to blue-enriched light had fewer PVT lapses (χ2 = 5.285, p = .022), reported feeling more alert (KSS: F1,77 = 4.955, p = .029; VASalert: F1,77 = 8.226, p = .005), and had improved mood (VAScheerful: F1,77 = 8.615, p = .004; VASdepressed: F1,77 = 4.649, p = .034; VASlethargic: F1,77 = 5.652, p = .020). Exposure to peppermint oil did not improve any outcome measures on any of the tasks compared to control condition (p > .05). Conclusions: We found that participants had fewer lapses of attention upon awakening when exposed to blue-enriched light compared to dim, red light. In addition, participants reported feeling more alert, more cheerful, less depressed, and less lethargic in the blue-enriched light condition. Brief exposure to a peppermint odor, however, did not appear to improve performance, alertness, or mood under the experimental conditions. Our null results in the peppermint condition may have been due to methodological limitations such as the duration and method of administration. Given the need to mitigate the potential impact of sleep inertia on safety-critical tasks in on-call operations, our findings suggest that blue-enriched light exposure upon awakening may help to improve performance and alertness during the sleep inertia period following awakening from deep, nocturnal sleep. We are currently exploring the potential mechanisms for the effect of light on cognitive performance upon awakening as well as investigating its application in real-world settings to explore the translational efficacy of this countermeasure to occupational environments. Continued exploration into light and other reactive countermeasures, and potentially their combination, is needed in order to provide evidence-based guidance on effective sleep inertia countermeasures to improve the alertness and performance of those required to perform safety-critical tasks soon after waking.

sleep inertia↗

Olfactory bulb units - Activity correlated with inhalation cycles and odor quality.

Single olfactory bulb units were studied in two macrosmatic species of rodents under conditions intended to preserve the cyclical stimulation which normally accompanies nasal breathing. Patterns of unit activity related to the inhalation cycle were observed in all animals, often in the absence of specific stimuli, and could not be explained in simple mechanical terms. Distinctive changes in these patterns occurred in response to certain odors, and were generally independent of changes in the overall firing frequency. These findings indicate that a change in the overall firing frequency of unit discharges is neither a necessary nor sufficient measure of responsiveness to odors in the rodent olfactory bulb, and that stimulus-specific temporal distributions of unit firing may be involved in olfacto-endocrine activities.

Macrides, F.↗

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS↗

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

Toilet↗