Thermocouple cements for nuclear rocket engine nozzles.
Cement materials to attach thermocouple to stainless steel tubing in nuclear rocket engine nozzle, considering thermal conductivity, bond and tensile and compressive strengths
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Cement materials to attach thermocouple to stainless steel tubing in nuclear rocket engine nozzle, considering thermal conductivity, bond and tensile and compressive strengths
Direct nuclear reactor radiation exposure effects on sheathed Chromel-Alumel and iron-Constantan thermocouples
Explore the source record for details and available documents.
Study establishes design criteria for constructing high temperature thermocouple to measure nuclear fuel pin temperature. The study included a literature search to determine the compatibility of material useful for thermocouples, a hot zone error analysis, and a prototype design for hot junction and connector pin connections.
Transient radiation effects on power reactor thermocouples determined at various levels of nuclear radiation
Ultrasonic pulse techniques have been developed which, when applied to inert gases, provide temperature measurements up to 8000 K. The response time can be less than 1 msec. This is a significant feature in studying shock-heated or combusting gases. Using a momentary contact coupling technique, temperature has been measured inside steel from 300 to 1500 K. Thin-wire sensors have been used above 2000 K in nuclear and industrial applications where conditions preclude the use of thermocouples, resistance devices, or optical pyrometers. At 2500 K, temperature sensitivity of 0.1% is obtained in Re wire sensors 5 cm long by timing five round trips with an electronic instrument that resolves the time interval between selected echoes to 0.1 microsec. Sensors have been operated at rotational speeds over 2000 rpm and in noisy environments. Temperature profiling of up to ten regions using only a single guided path or beam has also been accomplished.
Physical sensors fabricated with thin films could result a significant savings in space and weight with improved reliability for monitoring the long-term operation of fission surface power systems. Thin film sensors of 1 µm or less are attractive for FSP applications because they can be incorporated onto component surfaces with minimal machining and the additional weight to a system is minimal compared to thick film-, wire-, or foil-based sensors. The thin, surface fabrication of the sensors is also expected to make them less susceptible to deep dose effects that affect thicker sensors. An overview of thin film sensors using thermocouples and resistive elements designed, fabricated, and demonstrated at GRC for aerospace applications exceeding 900°C is presented.
Pedestal-type calorimeter measures gamma-ray heating rates from 0.5 to 7.0 watts per gram of aluminum. Nuclear heating rate is a function of cylinder temperature change, measured by four chromel-alumel thermocouples attached to the calorimeter, and known thermoconductivity of the tested material.
Metal boot splices hard sheathed instrumentation cables used with high temperature strain gages and thermocouples. Silver brazing the conductors together, hermetically seals the splice. This boot is a highly reliable sealed splice which is equally effective at cryogenic temperatures, high temperatures, nuclear environments, and combinations of the above.
Thermocouples of the present invention provide stability and performance reliability in systems involving high temperatures and vacuums by employing a bimetallic thermocouple sensor wherein each metal of the sensor is selected from a group of metals comprising tantalum and rhenium and alloys containing only those two metals. The tantalum, rhenium thermocouple sensor alloys provide bare metal thermocouple sensors having advantageous vapor pressure compatibilities and performance characteristics. The compatibility and physical characteristics of the thermocouple sensor alloys of the present invention result in improved emf, temperature properties and thermocouple hot junction performance. The thermocouples formed of the tantalum, rhenium alloys exhibit reliability and performance stability in systems involving high temperatures and vacuums and are adaptable to space propulsion and power systems and nuclear environments.
Radioisotope power systems (RPS) have been essential to the U.S. exploration of outer space. RPS have two primary uses: electrical power and thermal power. To provide electrical power, the RPS uses the heat produced by the natural decay of a radioisotope (e.g., plutonium-238 in U.S. RPS) to drive a converter (e.g., thermoelectric elements or Stirling linear alternator). As a thermal power source the heat is conducted to whatever component on the spacecraft needs to be kept warm; this heat can be produced by a radioisotope heater unit (RHU) or by using the excess heat of a radioisotope thermoelectric generator (RTG). As of 2010, the U.S. has launched 41 RTGs on 26 space systems. These space systems have ranged from navigational satellites to challenging outer planet missions such as Pioneer 10/11, Voyager 1/2, Galileo, Ulysses, Cassini and the New Horizons mission to Pluto. In the fall of 2011, NASA plans to launch the Mars Science Laboratory (MSL) that will employ the new Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) as the principal power source. Hundreds of radioisotope heater units (RHUs) have been launched to provide warmth to Apollo 11, used to provide heating of critical components in a seismic experiment package, Pioneer 10/11, Voyager 1/2, Galileo, Cassini, Mars Pathfinder, MER rovers, etc. to provide temperature control to critical spacecraft electronics and other mechanical devices such as propulsion system propellant valves. A radioisotope (electrical) power source or system (RPS) consists of three basic elements: (1) the radioisotope heat source that provides the thermal power, (2) the converter that transforms the thermal power into electrical power and (3) the heat rejection radiator. Figure 1 illustrates the basic features of an RPS. The idea of a radioisotope power source follows closely after the early investigations of radioactivity by researchers such as Henri Becquerel (1852-1908), Marie Curie (1867-1935), Pierre Curie (1859-1906) and R. J. Strut. Almost 100 years ago, in 1913, English physicist H. G. J. Moseley (1887-1915) constructed the first nuclear battery using a vacuum flask and 20 mCi of radium (Corliss and Harvey, 1964, Proceedings of the Royal Society, 1913). After World War II, serious interest in radioisotope power systems in the U.S. was sparked by studies of space satellites such as North American Aviation s 1947 report on nuclear space power and the RAND Corporation s 1949 report on radioisotope power. (Greenfield, 1947, Gendler and Kock, 1949). Radioisotopes were also considered in early studies of nuclear-powered aircraft (Corliss and Harvey, 1964). In 1951, the U.S. Atomic Energy Commission (AEC) signed several contracts to study a 1-kWe space power plant using reactors or radioisotopes. Several of these studies, which were completed in 1952, recommended the use of RPS. (Corliss and Harvey, 1964). In 1954, the RAND Corporation issued the summary report of the Project Feedback military satellite study in which radioisotope power was considered (Lipp and Salter, 1954, RAND). Paralleling these studies, in 1954, K. C. Jordan and J. H. Birden of the AEC s Mound Laboratory conceived and built the first RTG using chromel-constantan thermocouples and a polonium-210 (210Po or Po-210) radioisotope heat source (see Figure 2). While the power produced (1.8 mWe) was low by today s standards, this first RTG showed the feasibility of RPS. A second thermal battery was built with more Po-210, producing 9.4 mWe. Jordan and Birden concluded that the Po-210 thermal battery would have about ten times the energy of ordinary dry cells of the same mass (Jordan and Birden, 1954). The heat source consisted of a 1-cm-diameter sphere of 57 Ci (1.8 Wt) of Po-210 inside a capsule of nickel-coated cold-rolled steel all inside a container of Lucite. The thermocouples were silver-soldered chromel-constantan. The thermal battery produced 1.8 mWe.
There are many challenges involved in deep-space exploration, but several of these can be mitigated, or even solved, by the development of a coating that reflects most of the Sun’s energy, yet still provides far-infrared heat emission. Such a coating would allow non-heat-generating objects in space to reach cryogenic temperatures without using an active cooling system. This would benefit deep-space sensors that require low temperatures, such as the James Webb Telescope focal plane array. It would also allow the use of superconductors in deep space, which could lead to magnetic energy storage rings, lossless power delivery, or perhaps a large-volume magnetic shield against galactic cosmic radiation. However, perhaps the most significant enablement achieved from such a coating would be the long-term, deep space storage of cryogenic liquids, such as liquid oxygen (LOX). In our Phase I NIAC study, we realized that a combination of scattering particles and a silver backing could yield a highly effective, very broadband, reflector that could potentially reflect more than 99.9% of the Sun’s irradiant power. We developed a sophisticated model of this reflector and theoretically showed that cryogenic temperatures could be achieved in deep space at one astronomical unit (1 AU) from the Sun. We showed how this new reflector could minimize heat conduction into the cryogenic tanks by coating the tank support struts. We then modelled a strawman architecture for a mission to Mars, using a coated LOX tank, coated struts, and infrared shields, to show that with our new coating it would be possible to maintain liquid oxygen passively. As a result of this work a patent application was generated and a paper published in Optics Letters. Our Phase II NIAC study had two primary goals, to develop a rigid version of the cryogenic selective surface proposed in Phase I and to test its performance in a simulated deep space environment. During the first year of the project the work concentrated on developing rigid tiles of BaF2, leading to tiles as large as 4 inches in diameter that transmitted very little visible light. In addition, during the first year a simulated deep space environment was created using a vacuum chamber and cryocooler. Using this facility, we showed that our BaF2 tiles absorbed less than ¼% of 375 nm radiation, a significant milestone for the work. During the second year of the project, we continued to develop the BaF2 tiles and we put significant effort into the construction of a deep space environment where we could project simulated solar radiation onto a sample. In the spring of 2018, we conducted our first solar simulator test with BaF2 and saw about 3.6% absorption. This is better than the state-of-the-art, but disappointing since predictions were for much lower absorption. We, erroneously, attributed this absorption to water retention by the BaF2, and decided to change materials. We considered several oxides and settled on yttrium oxide (Y2O3) for further development, because it is broadband, lightweight, has high index, and is hydrophobic. In July 2018 we conducted our first test of a rigid tile of Y2O3 in the simulated deep space environment and saw significant absorption again. We then realized that the issue was not water, but mid-wave radiation passing through the tile and being absorbed by the temperature sensor and the varnish used to hold it in place. We wrapped the sensor in silver foil, re-ran the test, and saw much lower absorption; only 1.1%. We then re-ran the BaF2 tile and saw 1.4% absorption. These values are almost adequate to maintain LOX in deep space, but we suspect that there are still issues in our test apparatus; we suspect thermocouple wires may be absorbing radiation. Further, post-NIAC, testing will better determine the performance of our new solar reflector. In order to restrict the size of this report, we will only briefly describe topics that we have previously published, allowing us to devote more time to new material. So minimal material will be devoted to modeling the material and deep space cryogenic storage, while longer sections will cover our material development, simulated deep space testing, and new applications. The Launch Service Program (LSP) requested that we explore ways to use this new coating to maintain LOX in low Earth Orbit and that work is described. In addition, the Nuclear Thermal Propulsion (NTP) Program asked us to explore ways to reduce the heat load for liquid hydrogen, resulting in the development of a spray-on version of the coating that should significantly improve in-space multi-layer insulation performance.
The SAFE-I00a test article at the NASA Marshall Space Flight Center was used to simulate a variety of potential reactor transients; the SAFEl00a is a resistively heated, stainless-steel heat-pipe (HP)-reactor core segment, coupled to a gas-flow heat exchanger (HX). For these transients the core power was controlled by a point kinetics model with reactivity feedback based on core average temperature; the neutron generation time and the temperature feedback coefficient are provided as model inputs. This type of non-nuclear test is expected to provide reasonable approximation of reactor transient behavior because reactivity feedback is very simple in a compact fast reactor (simple, negative, and relatively monotonic temperature feedback, caused mostly by thermal expansion) and calculations show there are no significant reactivity effects associated with fluid in the HP (the worth of the entire inventory of Na in the core is .<el, so fluid movement and temperature changes will cause very minor effects). In previous SAFE-100 tests, the point kinetics model was based on core thermal expansion via deflection measurements. It was found that core deflection was a strung function of how the SAFE-100 modules were fabricated and assembled (in terms of straightness, gaps, and other tolerances). To remove the added variable of how this particular core expands as compared to a different concept, it was decided to use a temperature based feedback model (based on several thermocouples placed throughout the core).
For aircraft engine control, one key parameter to detect on an airplane is the exhaust gas temperature (EGT). Presently, thermocouples are used to perform this measurement. These electrical sensors perform adequately; however, fully utilizing the benefits of optical sensors requires replacing electrical architectures with optical architectures. Part of this requires replacing electrical sensors with optical sensors, such as the EGT sensor chosen for these tests. The objective of the development and testing of this prototype sensor system was to determine the feasibility of operating an optical sensor in a hostile aircraft environment. The fiber optic sensor system was developed to measure temperatures from 20C to 600C in an aircraft environment and was utilized to monitor the EGT of an OV-10D aircraft engine. The sensor has successfully flown over 50 hours and proven to be immune to surface deterioration of the optical element (located inside the sensor head) and able to withstand and operate in normal and sustained severe flight conditions where forces on the airplane exceeded 4 g's. Potential commercial uses for this sensor include monitoring temperature for aeropropulsion system control, military vehicle and naval engine control, conventional and nuclear power plant monitoring and industrial plan monitoring where EMI issues are critical.