Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nonionizing Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of computational small animal models and their applications in preclinical imaging and therapy research

The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

Purpose: Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors’ framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. Methods: The authors’ image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. Results: The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology—MRI fusion, in the context of an initial use case involving characterization of chronic inflammation in a mouse model. The authors’ evaluation considered three mice, two with an inflammation phenotype and one control. The authors’ iterative 3D histology reconstruction yielded a 70.1% ± 2.7% overlap with the ex vivo MRI volume. Across a total of 17 anatomic landmarks manually delineated at the division of airways, the target registration error between the ex vivo MRI and 3D histology reconstruction was 0.85 ± 0.44 mm, suggesting that a good alignment of the ex vivo 3D histology and ex vivo MRI had been achieved. The 3D histology-in vivo MRI coregistered volumes resulted in an overlap of 73.7% ± 0.9%. Preliminary computerized feature analysis was performed on an additional four control mice, for a total of seven mice considered in this study. Gabor texture filters appeared to best capture differences between the inflamed and noninflamed regions on MRI. Conclusions: The authors’ 3D histology reconstruction and multimodal registration framework were successfully employed to reconstruct the histology volume of the lung and fuse it with in vivo MRI to create a ground truth map for inflammation on in vivo MRI. The analytic platform presented here lays the framework for a rigorous validation of the identified imaging features for chronic lung inflammation on MRI in a large prospective cohort.

60 APPLIED LIFE SCIENCES↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Narrowband Lyman-continuum imaging of galaxies at z ∼ 2.85

We present results from a survey for z ∼ 2.85 Lyman-continuum (LyC) emission in the HS1549+1933 field and place constraints on the amount of ionizing radiation escaping from star-forming galaxies. Using a custom narrowband filter (NB3420) tuned to wavelengths just below the Lyman limit at z ≥ 2.82, we probe the LyC spectral region of 49 Lyman break galaxies (LBGs) and 91 Lyα emitters (LAEs) spectroscopically confirmed at z ≥ 2.82. Four LBGs and seven LAEs are detected in NB3420. Using V-band data probing the rest-frame nonionizing UV, we observe that many NB3420-detected galaxies exhibit spatial offsets between their LyC and nonionizing UV emission and are characterized by extremely blue NB3420–V colors, corresponding to low ratios of nonionizing to ionizing radiation (F {sub UV}/F {sub LyC}) that are in tension with current stellar population synthesis models. We measure average values of (F {sub UV}/F {sub LyC}) for our LBG and LAE samples, correcting for foreground galaxy contamination and H I absorption in the intergalactic medium. We find (F{sub UV}/F{sub LyC}){sub corr}{sup LBG}=82±45 and (F{sub UV}/F{sub LyC}){sub corr}{sup LAE}=7.4±3.6. These flux density ratios correspond, respectively, to relative LyC escape fractions of f{sub esc,} {sub rel}{sup LBG}=5%--8% and f{sub esc,} {sub rel}{sup LAE}=18%--49%, absolute LyC escape fractions of f{sub esc}{sup LBG}=1%--2% and f{sub esc}{sup LAE}=5%--15%, and a comoving LyC emissivity from star-forming galaxies of 8.8-15.0 × 10{sup 24} erg s{sup –1} Hz{sup –1} Mpc{sup –3}. In order to study the differential properties of galaxies with and without LyC detections, we analyze narrowband Lyα imaging and rest-frame near-infrared imaging, finding that while LAEs with LyC detections have lower Lyα equivalent widths on average, there is no substantial difference in the rest-frame near-infrared colors of LBGs or LAEs with and without LyC detections. These preliminary results are consistent with an orientation-dependent model where LyC emission escapes through cleared paths in a patchy interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Countdown to perovskite space launch: Guidelines to performing relevant radiation-hardness experiments

Perovskite photovoltaics (PVs) are under intensive development for promise in terrestrial energy production. Soon, the community will find out how much of that promise may become reality. Perovskites also open new opportunities for lower cost space power. However, radiation tolerance of space environments requires appropriate analysis of relevant devices irradiated under representative radiation conditions. We present guidelines designed to rigorously test the radiation tolerance of perovskite PVs. We review radiation conditions in common orbits, calculate nonionizing and ionizing energy losses (NIEL and IEL) for perovskites, and prioritize proton radiation for effective nuclear interactions. Low-energy protons (0.05-0.15 MeV) create a representative uniform damage profile, whereas higher energy protons (commonly used in ground-based evaluation) require significantly higher fluence to accumulate the equivalent displacement damage dose due to lower scattering probability. Furthermore, high-energy protons may "heal" devices through increased electronic ionization. These procedural guidelines differ from those used to test conventional semiconductors.

14 SOLAR ENERGY↗

Synthetic, Switchable Enzymes

The construction of switchable, radiation-controlled, aptameric enzymes - "swenzymes” - is, in principle, feasible. We propose a strategy to make such catalysts from 2 (or more) aptamers each selected to bind specifically to one of the substrates in, for example, a 2-substrate reaction. Construction of a combinatorial library of candidate swenzymes entails selecting a set of a million aptamers that bind one substrate and a second set of a million aptamers that bind the second substrate; the aptamers in these sets are then linked pairwise by a linker, thus bringing together the substrates. In the presence of the substrates, some linked aptamer pairs catalyze the reaction when exposed to external energy in the form of a specific frequency of low-intensity, nonionizing electromagnetic or acoustic radiation. Such swenzymes are detected via a separate product-capturing aptamer that changes conformation on capturing the product; this altered conformation allows it (1) to bind to every potential swenzyme in its vicinity (thereby giving a higher probability of capture to the swenzymes that generate the product) and (2) to bind to a sequence on a magnetic bead (thereby permitting purification of the swenzyme plus product-capturing aptamer by precipitation). Attempts to implement the swenzyme strategy may help elucidate fundamental problems in enzyme catalysis.

59 BASIC BIOLOGICAL SCIENCES↗

Ultraviolet radiation therapy and UVR dose models

Ultraviolet radiation (UVR) has been an effective treatment for a number of chronic skin disorders, and its ability to alleviate these conditions has been well documented. Although nonionizing, exposure to ultraviolet (UV) radiation is still damaging to deoxyribonucleic acid integrity, and has a number of unpleasant side effects ranging from erythema (sunburn) to carcinogenesis. As the conditions treated with this therapy tend to be chronic, exposures are repeated and can be high, increasing the lifetime probability of an adverse event or mutagenic effect. Despite the potential detrimental effects, quantitative ultraviolet dosimetry for phototherapy is an underdeveloped area and better dosimetry would allow clinicians to maximize biological effect whilst minimizing the repercussions of overexposure. This review gives a history and insight into the current state of UVR phototherapy, including an overview of biological effects of UVR, a discussion of UVR production, illness treated by this modality, cabin design and the clinical implementation of phototherapy, as well as clinical dose estimation techniques. Several dose models for ultraviolet phototherapy are also examined, and the need for an accurate computational dose estimation method in ultraviolet phototherapy is discussed.

60 APPLIED LIFE SCIENCES↗

SU-E-J-114: Towards Integrated CT and Ultrasound Guided Radiation Therapy Using A Robotic Arm with Virtual Springs

Purpose: Currently there is an urgent need in Radiation Therapy for noninvasive and nonionizing soft tissue target guidance such as localization before treatment and continuous monitoring during treatment. Ultrasound is a portable, low cost option that can be easily integrated with the LINAC room. We are developing a cooperatively controlled robot arm that has high intrafraction reproducibility with repositioning of the ultrasound probe. In this study, we introduce virtual springs (VS) to assist with interfraction probe repositioning and we compare the soft tissue deformation introduced by VS to the deformation that would exist without them. Methods: Three metal markers were surgically implanted in the kidney of one dog. The dog was anesthetized and immobilized supine in an alpha cradle. The reference ultrasound probe position and force to ideally visualize the kidney was defined by an experienced ultrasonographer using the Clarity ultrasound system and robot sensor. For each interfraction study, the dog was removed from the cradle and re-setup based on CBCT with bony anatomy alignment to mimic regular patient setup. The ultrasound probe was automatically returned to the reference position using the robot. To accommodate the soft tissue anatomy changes between each setup the operator used the VS feature to adjust the probe and obtain an ultrasound image that matched the reference image. CBCT images were acquired and each interfraction marker location was compared with the first interfraction Result. Results: Analysis of the marker positions revealed that the kidney was displaced by 18.8 ± 6.4 mm without VS and 19.9 ± 10.5 mm with VS. No statistically significant differences were found between two procedures. Conclusion: The VS feature is necessary to obtain matching ultrasound images, and they do not introduce further changes to the tissue deformation. Future work will focus on automatic VS based on ultrasound feedback. Supported in part by: NCI R01 CA161613; Elekta Sponsored Research.

60 APPLIED LIFE SCIENCES↗

Tolerance of Perovskite Solar Cells to Targeted Proton Irradiation and Electronic Ionization Induced Healing

Mixed organic–inorganic halide perovskite solar cells (PSCs) are of interest for space photovoltaic applications due to their apparent tolerance to high-energy proton radiation. Here, the use of a more stable wide-bandgap FA0.8Cs0.2PbI2.4Br0.6Cl0.02 perovskite with thin encapsulation enables, for the first time, the detailed dependence of fluence and energy of energetic protons on device performance. Energies were chosen to provide the highest concentration of displacements within the active region, and therefore the highest amount of degradation. Not only are these devices tolerant when compared to conventional technologies, but an unexpected increase in open circuit voltage and power density is observed for increased electronic ionization when the proton energy is increased. This study aims to expand the description of the proton radiation tolerance to include not only nonionizing nuclear energy losses that are most detrimental to current technologies, but electronic ionization, which is shown to yield benefits in PSCs.

device performance↗

Microangiography in Living Mice Using Synchrotron Radiation

Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 {mu}m/pixel. The optimal dose of contrast agent is 100 {mu}l per injection and the injecting rate is 33 {mu}l/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43{+-}6.8 {mu}m. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Pediatric Abdominal Organ Motion With a 4-Dimensional Magnetic Resonance Imaging Method

Purpose: To characterize respiration-induced abdominal organ motion in children receiving radiation treatment with a 4-dimensional (4D) magnetic resonance imaging (MRI) method. Methods and Materials: We analyzed free-breathing coronal 4D MRI datasets acquired from 35 patients (aged 1-20 years) with abdominal tumors. A deformable image registration of the 4D MRI datasets was performed to derive motion trajectories of selected anatomic landmarks, from which organ motions were quantified. The association between organ motion and patient characteristics was investigated and compared with previous studies. The relation between patient height and organ motion was further investigated to predict organ motion in prospective patients. Results: Organ motion and its individual variation were reduced in younger patients (eg, kidney peak-to-peak motion <5 mm for all but 1 patient aged ≤8 years), although special motion management may be warranted in some adolescents. The liver and spleen exhibited greater motion than did the kidneys, while intraorgan variation was present. The motions in the liver and kidneys agreed with those reported by the previous 4D computed tomography studies. Individual variations of organ motion in younger patients were due, in part, to changes in respiration rate, which ostensibly reflected the effect of anesthesia. The prediction of organ motion was limited by large individual variations, particularly for older patients. Conclusions: The 4D MRI acquisition method and motion analysis described in this study provide a nonionizing approach to understand age-associated organ motion, which aids in the planning of abdominal radiation therapy for pediatric patients. Use of 4D MRI facilitates monitoring of changes in target motion patterns during treatment courses and in various studies of the effect of organ motion on radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positron annihilation characteristics in mesostructural silica films with various porosities

Porous silica films with various porosities were prepared via a sol-gel method using a nonionic amphiphilic triblock copolymer F127 as the structure-directing agent. Doppler broadening of positron annihilation radiation (DBAR) spectra were collected for the prepared films using a variable energy slow positron beam. Different linear relationships between positron annihilation line shape parameters S and W are found for the as-deposited films and calcined ones, indicative of the decomposition of the copolymer porogen in the as-deposited films upon calcination. This also reveals the variation of positron annihilation sites as a function of F127 loading or porosity. Strong correlations between positronium 3γ annihilation fraction, S parameter and porosity of the mesoporous silica films with isolated pores are obtained, which may provide a complementary method to determine closed porosities of mesoporous silica films by DBAR.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bronchoscopic Implantation of a Novel Wireless Electromagnetic Transponder in the Canine Lung: A Feasibility Study

Purpose: The success of targeted radiation therapy for lung cancer treatment is limited by tumor motion during breathing. A real-time, objective, nonionizing, electromagnetic localization system using implanted electromagnetic transponders has been developed (Beacon electromagnetic transponder, Calypso Medical Technologies, Inc., Seattle, WA). We evaluated the feasibility and fixation of electromagnetic transponders bronchoscopically implanted in small airways of canine lungs and compared to results using gold markers. Methods and Materials: After approval of the Animal Studies Committee, five mongrel dogs were anesthetized, intubated, and ventilated. Three transponders were inserted into the tip of a plastic catheter, passed through the working channel of a flexible bronchoscope, and implanted into small airways of a single lobe using fluoroscopic guidance. This procedure was repeated for three spherical gold markers in the opposite lung. One, 7, 14, 28, and 60 days postimplantation imaging was used to assess implant fixation. Results: Successful bronchoscopic implantation was possible for 15 of 15 transponders and 12 of 15 gold markers; 3 markers were deposited in the pleural space. Fixation at 1 day was 15 of 15 for transponders and 12 of 12 for gold markers. Fixation at 60 days was 6 of 15 for transponders and 7 of 12 for gold markers, p value = 0.45. Conclusions: Bronchoscopic implantation of both transponders and gold markers into the canine lung is feasible, but fixation rates are low. If fixation rates can be improved, implantable electromagnetic transponders may allow improved radiation therapy for lung cancer by providing real-time continuous target tracking. Developmental work is under way to improve the fixation rates and to reduce sensitivity to implantation technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation effects in single-walled carbon nanotube papers

The effects of ionizing radiation on the temperature-dependent conductivity of single-walled carbon nanotube (SWCNT) papers have been investigated in situ in a high vacuum environment. Irradiation of the SWCNT papers with 4.2 MeV alpha particles results in a steady decrease in the SWCNT paper conductivity, resulting in a 25% reduction in room temperature conductivity after a fluence of 3x10{sup 12} alpha particles/cm{sup 2}. The radiation-induced temperature-dependent conductivity modification indicates that radiation damage causes an increase in the effective activation barrier for tunneling-like conductivity and a concomitant increase in wavefunction localization of charge carriers within individual SWCNTs. The spatial defect generation within the SWCNT paper was modeled and confirms that a uniform displacement damage dose was imparted to the paper. This allows the damage coefficient (i.e., differential change in conductivity with fluence) for alpha particles, carbon ions, and protons to be compared with the corresponding nonionizing energy loss (NIEL) of the incident particle. The resulting nonlinear relationship with NIEL between these parameters is distinct from the more typical linear response observed in many bulk semiconductors and superconductors and indicates that localized radiation damage in the SWCNT papers has a greater impact than distributed damage. Although SWCNT papers behave largely as a bulk material with properties that are a convolution of the underlying SWCNT distribution, the radiation response appears to be largely dominated by degradation in the preferred one-dimensional conduction within these two-dimensionally confined nanostructures.

36 MATERIALS SCIENCE↗

Radiation tolerance of a high quality synthetic single crystal chemical vapor deposition diamond detector irradiated by 14.8 MeV neutrons

Diamond exhibits many properties such as an outstanding radiation hardness and fast response time both important to design detectors working in extremely radioactive environments. Among the many applications these devices can be used for, there is the development of a fast and radiation hard neutron detector for the next generation of fusion reactors, such as the International Thermonuclear Experimental Reactor project, under construction at Cadarache in France. A technology to routinely produce electronic grade synthetic single crystal diamond detectors was recently developed by our group. One of such detectors, with an energy resolution of 0.9% as measured using an {sup 241}Am{alpha} particle source, has been heavily irradiated with 14.8 MeV neutrons produced by the Frascati Neutron Generator. The modifications of its spectroscopic properties have been studied as a function of the neutron fluence up to 2.0x10{sup 14} n/cm{sup 2}. In the early stage of the irradiation procedure an improvement in the spectroscopic performance of the detector was observed. Subsequently the detection performance remains stable for all the given neutron fluence up to the final one thus assessing a remarkable radiation hardness of the device. The neutron damage in materials has been calculated and compared with the experimental results. This comparison is discussed within the nonionizing energy loss (NIEL) hypothesis, which states that performance degradation is proportional to NIEL.

36 MATERIALS SCIENCE↗

Detection of radiation induced lung injury in rats using dynamic hyperpolarized {sup 129}Xe magnetic resonance spectroscopy

Purpose: Radiation induced lung injury (RILI) is a common side effect for patients undergoing thoracic radiation therapy (RT). RILI can lead to temporary or permanent loss of lung function and in extreme cases, death. Combining functional lung imaging information with conventional radiation treatment plans may lead to more desirable treatment plans that reduce lung toxicity and improve the quality of life for lung cancer survivors. Magnetic Resonance Imaging of the lung following inhalation of hyperpolarized{sup 129}Xe may provide a useful nonionizing approach for probing changes in lung function and structure associated with RILI before, during, or after RT (early and late time-points). Methods: In this study, dynamic{sup 129}Xe MR spectroscopy was used to measure whole-lung gas transfer time constants for lung tissue and red blood cells (RBC), respectively (T{sub Tr-tissue} and T{sub Tr-RBC}) in groups of rats at two weeks and six weeks following 14 Gy whole-lung exposure to radiation from a {sup 60}Co source. A separate group of six healthy age-matched rats served as a control group. Results: T{sub Tr-tissue} values at two weeks post-irradiation (51.6 ± 6.8 ms) were found to be significantly elevated (p < 0.05) with respect to the healthy control group (37.2 ± 4.8 ms). T{sub Tr-RBC} did not show any significant changes between groups. T{sub Tr-tissue} was strongly correlated with T{sub Tr-RBC} in the control group (r = 0.9601 p < 0.05) and uncorrelated in the irradiated groups. Measurements of arterial partial pressure of oxygen obtained by arterial blood sampling were found to be significantly decreased (p < 0.05) in the two-week group (54.2 ± 12.3 mm Hg) compared to those from a representative control group (85.0 ± 10.0 mm Hg). Histology of a separate group of similarly irradiated animals confirmed the presence of inflammation due to radiation exposure with alveolar wall thicknesses that were significantly different (p < 0.05). At six weeks post-irradiation, T{sub Tr-tissue} returned to values (35.6 ± 9.6 ms) that were not significantly different from baseline. Conclusions: Whole-lung tissue transfer time constants for{sup 129}Xe (T{sub Tr-tissue}) can be used to detect the early phase of RILI in a rat model involving 14 Gy thoracic {sup 60}Co exposure as early as two weeks post-irradiation. This knowledge combined with more sophisticated models of gas exchange and imaging techniques, may allow functional lung avoidance radiation therapy planning to be achievable, providing more beneficial treatment plans and improved quality of life for recovering lung cancer patients.

60 APPLIED LIFE SCIENCES↗

Effects of Proton Irradiation on the Performance of Skipper CCDs

Skipper CCDs are a mature detector technology that has been suggested for future space telescope instruments requiring sub-electron readout noise in the near-ultraviolet to the near-infrared. While modern skipper CCDs inherit from the radiation-tolerant p-channel detectors developed by LBNL, the effects of high doses of ionizing radiation on skipper CCDs (such as those expected in space) remains largely unmeasured. We report preliminary results on the performance of p-channel skipper CCDs following irradiation with 217-MeV protons at the Northwestern Medicine Proton Center. The total nonionizing energy loss (NIEL) experienced by the detectors exceeds 6 years at the Sun-Earth Lagrange Point 2 (L2). We demonstrate that the skipper amplifier continues to function as expected following this irradiation. Owing to the low readout noise of these detectors, controlled irradiation tests can be used to sensitively characterize the charge transfer inefficiency, dark current, and the density and time constants of charge traps as a function of proton fluence. We conclude with a brief outlook toward future tests of these detectors at other proton and gamma-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-20: Commissioning and Acceptance Testing of the C-Rad CatalystHD Surface Imaging System

Introduction: With the increasing use of surface-based, nonionizing image-guided radiotherapy (IGRT) systems, a comprehensive set of clinical acceptance and commissioning procedures are needed to ensure correct functionality and proper clinical integration. Although TG-147 provides a specific set of parameters, measurement methodologies have yet to be described. The aim of this study was to provide a comprehensive overview of the commissioning and acceptance analysis performed for the C-Rad CatalystHD imaging system. Methods and Materials: Methodology for the commissioning and acceptance of the C-Rad CatalystHD imaging system was developed using commercially available clinical equipment. Following TG-147 guidelines, the following tests were performed: integration of peripheral equipment, system drift, static spatial reproducibility and localization accuracy, static end-to-end analysis, static rotational accuracy, dynamic spatial accuracy, dynamic temporal accuracy, dynamic radiation delivery and a comprehensive end-to-end analysis. Results: The field of view (FOV) of the CatalystHD was 105×109×83 cm3 in the lateral, longitudinal and vertical directions. For thermal equilibrium and system drift, a thermal drift of 1.0mm was noted. A 45 min warmup time is recommended if the system has been shut off an extended period of time (>24 hours) before the QA procedure to eliminate any thermal drift. Spatial reproducibility was found to be 0.05±0.03 mm using a rigid phantom. For the static localization accuracy, system agreement with couch shifts was within 0.1±0.1 mm and positioning agreement with kV-CBCT was 0.16±0.10 mm. For static rotational accuracy, system agreement with a high precision rotational stage (0.01 deg precision) was within 0.10±0.07 deg. Dynamic spatial and temporal localization accuracy was found to be within 0.2±0.1 mm. Conclusion: A comprehensive commissioning and acceptance study was performed using commercially available phantoms and in-house methodologies to provide a performance evaluation of the CatalystHD imaging system.

60 APPLIED LIFE SCIENCES↗