Emission lifetimes of europium-doped pyrochlores for phosphor thermometry

The luminescent lifetime of La2Zr2O7 and La2Hf2O7 has been determined as a function of temperature. We have shown that the luminescence of both materials can be used to determine the temperature of a surface up to 1073 K. The results are qualitatively explained via multiphonon emission. Phonon energies and the number of phonons needed to cross the energy gap are estimated. The results are useful in the design of phosphors for noncontact thermometry in high-temperature applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phosphor Thermometry Signal Analysis and Interpretation

Since the last International Temperature Symposium, phosphor thermometry has continued to mature with considerable attention given to combustion and turbine engine applications. More recently the utility to problems on the micro- and nano-scales has appreciated, particularly in regard to biological and biomedical situations. The method is therefore used for a wide range of situations. Signal interpretation is important and experience teaches that without sufficient care phosphor signals can be misleading. In order to advance the method, signal analysis investigations should prove fruitful. The specific aspect addressed here is the question of waveform sampling. A simple phenomenological approach is described that explores how the number of points digitized per waveform affects the measurement repeatability and accuracy. This is demonstrated for single shot signals and the average of 512 sequential waveforms. A bright temperature-independent luminescence signal from YVO4:Eu is sampled every 800 ps for a highly sampled condition and every 8 microseconds for a low sampled condition. When the average of 512 waveforms are compared for the two sampling conditions, they differ by only 0.4%. For the highly sampled case, a noisy single shot waveform compared to the averaged waveform differed by 1.8%. Future efforts on this subject will address intermediate and lower sampling rates. Also, variable window techniques should be explored that are especially important for non-log-linear signals. Investigations, such as this, give the developer the requisite information for designing analysis systems appropriate for the intended application in terms of precision, accuracy, and response time.

Fluorescence thermometry↗

Design of Phosphor Thermometry System for Transient High Heat Flux Surface Thermometry

Abstract: A transformative calibration methodology is presented for predicting transient surface temperatures in a thermally conducting medium from in-depth, time-varying temperature measurements. The surface temperature is resolved using two experimental runs and a newly devised first-kind Volterra integral equation. The first experimental run involves calibration with known surface temperature while the second run involves resolving the surface temperature of interest through the ill-posed integral equation. This paper presents the concept genesis and numerically demonstrates the concept for feasibility, robustness, stability and accuracy. From this demonstration, we propose to implement surface placed thermographic phosphors in the calibration stage of the inverse method for estimating the required surface temperature. As a preliminary study, we consider transient, constant property, onedimensional heat conduction in a semi-infinite medium. It is mathematically demonstrated that a Volterra integral equation of the first kind is developed for estimating the surface temperature using a calibrated system (host material and sensor). Sensor characterization, explicit sensor positioning and thermophysical properties are implicitly contained in the new calibration integral equation. The calibration integral equation displays only four terms; namely, the measured front surface temperature and corresponding measured in-depth temperature response associated with the calibration run; and, the unknown surface temperature and its measured in-depth temperature response associated with the second run. Preliminary numerical results indicate the merit of the concept. This paper suggests using thermographic phosphors for estimating the surface temperature in the calibration portion of the process owing to their rapid thermal response, good surface thermal contact characteristics and lack of capacitance for assuring minimal delay. Though the present paper describes the theoretical basis for resolving such problems, it is intended for near-term application using the UTK s high-heat flux laser facility which is presently under development

Fluorescence thermometry↗

Progress Toward Luminescence-Based VAATE Turbine Blade And Vane Temperature Measurement

Progress towards fielding luminescence-based temperature measurements for the Versatile Affordable Advanced Turbine Engine (VAATE) program is described. The near term programmatic objective is to monitor turbine vane temperatures and health by luminescence from a rare-earth doped thermal barrier coating (TBC), or from a thermographic phosphor layer coated onto a TBC. The first goal is to establish the temperature measurement capability to 1300 C with 1 percent uncertainty in a test engine. An eventual goal is to address rotating turbine blades in an F135 engine. The project consists of four phases, of which the first two have been completed and are described in this paper. The first phase involved laser heating of a 2.54-cm-diameter test sample, coated with a TBC and a thermographic phosphor layer, to produce a thermal gradient across the TBC layer similar to that expected in a turbine engine. Phosphor temperatures correlated well with those measured by long wavelength pyrometry. In the second phase, 10x10- cm coupons were exposed to a jet fuel flame at a burner rig facility. The thermographic phosphor/TBC combination survived the aggressive flame and high exhaust gas velocity, even though the metal substrate melted. Reliable temperature measurements were made up to about 1400 C using YAG:Dy as the thermographic phosphor. In addition, temperature measurements using YAG:Tm showed very desirable background radiation suppression.

Fluorescence thermometry↗

An Optothermal Raman Model Accounting for Convection, Radiation, and Substrate Effects for Evaluation of the Thermal Conductivity of Two‐Dimensional Coatings

Thermal conductivity of two‐dimensional (2D) materials is important to characterize as this will govern thermal transport physics in the various thermal and energy applications benefitting from the unique properties of these materials. Here, analytical and numerical techniques are presented to determine the thermal conductivity and interfacial conductance of a 2D material coating using confocal micro‐Raman spectroscopy as a noncontact diagnostic. While several methods have been proposed for calculating the values of thermal conductivity, interfacial conductance, and spatial temperature profile, these models often do not consider effects of radiation, convection, and substrate resistance on the temperature and heat flux profiles. We present a model to calculate the thermal conductivity and interfacial conductance which accounts for convection, radiation, and substrate effects to characterize a variety of 2D material coatings, which is demonstrated using large area graphene transferred onto copper and nickel substrates. Convection and radiation effects are found to have a negligible effect on the temperature profile of supported coatings, while the substrate effects have a considerable effect and therefore impact the quantification of thermal conductivity and interfacial conductance in addition to limiting the spatial resolution of the technique. These findings will allow for more accurate and reproducible extraction of the thermal conductivity of graphene and other 2D material coatings when employing noncontact optothermal Raman spectroscopy methods.

2D coatings↗

Interface-Dependent Radiative Lifetimes of Yb3+, Er3+ Co-doped Single NaYF4 Upconversion Nanowires

The development of upconversion nanomaterials for many photonic applications requires a detailed understanding of their radiative lifetimes that in turn depend critically on local environmental conditions. In this work, hexagonal (ß-phase) sodium-yttrium-?uoride (NaYF4) nanowires (NWs) were synthesized and substitutionally co-doped with a luminescent solid solution of trivalent erbium and ytterbium ions. A single-beam laser trapping instrument was used in tandem with a piezo-controlled, variable-temperature stage to precisely vary the nanowire’s distance from the substrate. The spontaneous photoluminescence lifetime of the 4S3/2 ? 4I15/2 transition from Er3+ ions was observed to change by >60% depending on the ions’ separation distance from a planar (water/glass) dielectric interface. The 4S3/2 state lifetime is observed to increase by a factor of 1.62 ± 0.01 as the distance from the quartz coverslip increases from ~0 nm to~40 µm. Less signi?cant changes in the luminescence lifetime (=10%) were observed over a temperature range between 25 and 50 °C. The distance dependence of the lifetime is interpreted quantitatively in the context of classical electromagnetic coupling between Er3+ ions within the nanowire and the adjacent dielectric interface. We also demonstrate potential applications of the NaYF4 NWs for both controlling and probing temperatures at nanometer scales by integrating them within a poly(dimethylsiloxane) composite matrix.

upconversion, nanowires, radiative lifetime, optic↗

Raman and infrared thermometry for microsystems.

This paper compares measurements made by Raman and infrared thermometry on a SOI (silicon on insulator) bent-beam thermal microactuator. Both techniques are noncontact and used to experimentally measure temperatures along the legs and on the shuttle of the thermal microactuators. Raman thermometry offers micron spatial resolution and measurement uncertainties of {+-}10 K; however, typical data collection times are a minute per location leading to measurement times on the order of hours for a complete temperature profile. Infrared thermometry obtains a full-field measurement so the data collection time is much shorter; however, the spatial resolution is lower and calibrating the system for quantitative measurements is challenging. By obtaining thermal profiles on the same SOI thermal microactuator, the relative strengths and weaknesses of the two techniques are assessed.

42 ENGINEERING↗

Raman and infrared thermometry for microsystems.

This paper compares measurements made by Raman and infrared thermometry on a SOI (silicon on insulator) bent-beam thermal microactuator. Both techniques are noncontact and used to experimentally measure temperatures along the legs and on the shuttle of the thermal microactuators. Raman thermometry offers micron spatial resolution and measurement uncertainties of {+-}10 K; however, typical data collection times are a minute per location leading to measurement times on the order of hours for a complete temperature profile. Infrared thermometry obtains a full-field measurement so the data collection time is much shorter; however, the spatial resolution is lower and calibrating the system for quantitative measurements is challenging. By obtaining thermal profiles on the same SOI thermal microactuator, the relative strengths and weaknesses of the two techniques are assessed.

42 ENGINEERING↗

Raman scattering in single-crystal sapphire at elevated temperatures

Sapphire is a widely used high-temperature material and this work presents thorough characterization of all the measurable Raman scattering modes in sapphire and their temperature dependencies. Here, Raman scattering in bulk sapphire rods is measured from room temperature to 1081 °C and is illustrated as a method of noncontact temperature measurement. A single-line argon ion laser at 488 nm was used to excite the sapphire rods inside a cylindrical furnace. All the anti-Stokes peaks (or lines) were observable through the entire temperature range of interest, while Stokes peaks were observable until they were obscured by background thermal emission. Temperature measurements were found to be most reliable for A 1g and E g modes using the peaks at ±418, ±379, +578, +645, and, +750 cm -1 (+ and – are designated for Stokes and anti-Stokes peaks respectively). The 418 cm -1 peak was found to be the most intense peak. The temperature dependence of peak position, peak width, and peak area of the ±418 and ±379 peaks is presented. For +578, +645 and +750, the temperature dependence of peak position is presented. The peaks’ spectral positions provide the most precise temperature information within the experimental temperature range. Finally, the resultant temperature calibration curves are given, which indicate that sapphire can be used in high-temperature Raman thermometry with an accuracy of about 1.38°C average standard deviation over the entire >1000°C temperature range.

20 FOSSIL-FUELED POWER PLANTS↗