Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Non Intrusive Load Monitoring (NILM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characteristics and Performance of Existing Load Disaggregation Technologies

Non-intrusive load monitoring (NILM) or non-intrusive appliance load monitoring (NIALM) is an analytic approach to disaggregate building loads based on a single metering point. This advanced load monitoring and disaggregation technique has the potential to provide an alternative solution to high-priced traditional sub-metering and enable innovative approaches for energy conservation, energy efficiency, and demand response. However, since the inception of the concept in the 1980’s, evaluations of these technologies have focused on reporting performance accuracy without investigating sources of inaccuracies or fully understanding and articulating the meaning of the metrics used to quantify performance. As a result, the market for, as well as, advances in these technologies have been slowly maturing. To improve the market for these NILM technologies, there has to be confidence that the deployment will lead to benefits. In reality, every end-user and application that this technology may enable does not require the highest levels of performance accuracy to produce benefits. Also, there are other important characteristics that need to be considered, which may affect the appeal of NILM products to certain market targets (i.e. residential and commercial building consumers) and the suitability for particular applications. These characteristics include the following: 1) ease of use, the level of expertise/bandwidth required to properly use the product; 2) ease of installation, the level of expertise required to install along with hardware needs that impact product cost; and 3) ability to inform decisions and actions, whether the energy outputs received by end-users (e.g. third party applications, residential users, building operators, etc.) empower decisions and actions to be taken at time frames required for certain applications. Therefore, stakeholders, researchers, and other interested parties should be kept abreast of the evolving capabilities, uses, and characteristics of NILM that make them attractive for certain building environments and different classes of end-users. The intent of this report is to raise awareness of trending NILM approaches. Additionally, three existing technologies were acquired and evaluated using the Residential Building Stock Assessment (RBSA) owner-occupied test bed operated by the Northwest Energy Efficiency Alliance (NEEA) to understand performance accuracy of current NILM products under realistic conditions. Based on this field study experience, the characteristics exhibited by the NILM products included in the assessment are also discussed in this report in terms of ease of use, ease of installation, ability to inform decisions and actions. Results of the analysis performed to investigate the accuracy of the participating NILM products in estimating energy use of individual appliances are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Harmonic Signals Dataset

The Harmonic Signals Dataset (HSD) consists of one-dimensional time series data collected from current sensors with a goal of providing data for research and development of Non-Intrusive Load Monitoring (NILM) with high sample rate (800kHz) sensors. NILM seeks to detect and characterize electrical equipment operating within a facility by sensing changes in electrical current on the building power system associated with the equipment. To provide data with a known ground truth, but with the realism of a signal introduced within a building facility, a series of known ground truth signals were injected as voltage into the power system of a building and measurements of the signals at multiple locations across the building power system were made with electrical current sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NILM Applications for the Energy-Efficient Home

We present a forecast for systems-focused applications of non-intrusive load monitoring (NILM), which meet the needs of homeowners, the technology sector, the service sector, and/or utilities. We discuss both near- and long-term applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multivariate exploration of non-intrusive load monitoring via spatiotemporal pattern network

Non-intrusive load monitoring (NILM) of electrical demand for the purpose of identifying load components has thus far mostly been studied using univariate data, e.g., using only whole building electricity consumption time series to identify a certain type of end-use such as lighting load. However, using additional variables in the form of multivariate time series data may provide more information in terms of extracting distinguishable features in the context of energy disaggregation. In this work, a novel probabilistic graphical modeling approach, namely the spatiotemporal pattern network (STPN) is proposed for energy disaggregation using multivariate time-series data. The STPN framework is shown to be capable of handling diverse types of multivariate time-series to improve the energy disaggregation performance. The technique outperforms the state of the art factorial hidden Markov models (FHMM) and combinatorial optimization (CO) techniques in multiple real-life test cases. Furthermore, based on two homes' aggregate electric consumption data, a similarity metric is defined for the energy disaggregation of one home using a trained model based on the other home (i.e., out-of-sample case). The proposed similarity metric allows us to enhance scalability via learning supervised models for a few homes and deploying such models to many other similar but unmodeled homes with significantly high disaggregation accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Classification of Unintended Radiated Emissions in a Multi-Device Environment

Here, unintended radiated emissions (URE) from electronic devices are conducted on to the power infrastructure and can be collected and analyzed for non-intrusive load monitoring (NILM) applications. Dimensionally aligned signal projections (DASP) were previously introduced as specialized signal transforms to enable device classification using machine learning on statistical features derived from the DASP transforms. In this work, we explore multi-device classification which requires more sophisticated methods owing to the complexity of the feature space such as large dynamic range, non-contiguous features, over-lapping features, and nonlinear interactions of features. In particular, we introduce an additional DASP algorithm for increased resolution and sensitivity to intermodulation products and examine the utility of convolutional neural networks (CNNs) to extract and learn features directly from DASP images for classification of single and multiple device URE captures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report On Non-Intrusive Load Monitoring Of Welding Processes

The conventional method of weld process monitoring is to monitor the process output electrical power close to the point of welding. Non-Intrusive Load Monitoring (NILM) describes the method of monitoring primary or utility electrical power into a welding process well away from the point of welding. The objective of this project was to determine if there is sufficient information within the welding process input power to understand process output power characteristics, and, if so, determine if there is sufficient resolution within the input electrical characteristics to infer some measures of weld quality. To understand the relationship between process input and output power, both input and output power were monitored for two welding processes (GMAW and GTAW) and two different power source types (inverter and SCR). Welds were made with and without intentional disturbances. The results showed that there is a strong correlation between input and output power and that the influence of process disturbances are evident within the input power. A simple method using input power only was devised and successfully demonstrated to discriminate between a weld made with no intentional disturbance (a nominal weld) from a weld made with an intentional disturbance (off-nominal weld). The primary conclusions of this work is that NILM of process input power is sensitive to process disturbances that could influence weld quality and that the approach warrants additional study.

36 MATERIALS SCIENCE↗

HVAC load Disaggregation using Low-resolution Smart Meter Data

Traditional non-intrusive load monitoring (NILM) methods are effective for load disaggregation using high resolution smart meter data collected by power quality meters. However, smart meter data collected and stored by utilities are normally 15-, 30- or 60-minute in granularity, making most NILM methods ineffective. This paper presents a novel sequential energy disaggregation (SED) algorithm for extracting heating, ventilation, and air conditioning (HVAC) energy consumptions from residential and small commercial building loads using 30 min smart meter data. Large, infrequently-used loads are first detected and removed from the total building energy consumption. Then, base energy consumption curves, defined as the energy consumption without heating and cooling loads, are identified using the mild-day method. After that, the heating and cooling loads are extracted using an average value subtracting method. Simulation results with real data show that the proposed SED method is computationally efficient, simple to implement and robust in performance across different types of buildings.

Liang, Ming↗

Improving Robustness of Spectrogram Classifiers with Neural Stochastic Differential Equations

Signal analysis and classification is fraught with high levels of noise and perturbation. Computer-vision-based deep learning models applied to spectrograms have proven useful in the field of signal classification and detection; however, these methods aren't designed to handle the low signal-to-noise ratios inherent within non-vision signal processing tasks. While they are powerful, they are currently not the method of choice in the inherently noisy and dynamic critical infrastructure domain, such as smart-grid sensing, anomaly detection, and non-intrusive load monitoring. Currently, these models can be brittle, which makes them susceptible to noisy input. This also means they have sub-optimal stability of explanation outputs. Experts and technicians using these models to make decisions in real world scenarios need assurance that a model is performing as it is supposed to. The classification or prediction outputs it generates should be sound and grounded, not likely to change in the presence of shifting noise landscapes. In this work, we explore the idea of Neural Stochastic Differential Equations (NSDE's) to improve the robustness of models trained to classify time series data and the effect of NSDE's on the explainability of outputs. We then test the effectiveness of these approaches by applying them to a non-intrusive load monitoring (NILM) dataset that consists of simulated harmonic signals injected into a real building.

Brogan, Joel↗

ShareAnalytics

ShareAnalytics is a lightweight extensible platform for collaborative data analytics and facility characterization via Non-intrusive Load Monitoring (NILM). It consists of three core components: a full stack web application, a dashboard tool for analyzing streaming data and a High Performance Computing (HPC) cluster leveraging slurm for resource management to perform real time analysis. The entire framework is implemented in Docker for ease of deployment and to allow the user to test the platform before making a significant investment in hardware if they require additional computing resources. While many other platforms for analyzing streaming data exists, ShareAnalytics is unique in that HPC capabilities and facility characterization via scored analytics are fully integrated into the platform.

Oesch, TimothyS↗

Business Case for Nonintrusive Load Monitoring

This report explores how utilities, researchers, and consumers could benefit from a lower cost approach to submetering using non-intrusive load monitoring (NILM). NILM is a process of using data from a single point of monitoring, such as a utility smart meter, to provide an itemized accounting of end use energy consumption in residential and small commercial buildings. Pacific Northwest National Laboratory (PNNL) prepared this report for the Bonneville Power Administration (BPA). PNNL participated in an advisory group as part of a research project sponsored by the U.S. Department of Energy (DOE), the Bonneville Power Administration, and the State of Washington. The Electric Power Research Institute (EPRI) convened the advisory committee for two workshops held to identify ways in which NILM may be used. PNNL, on behalf of DOE, helped to cosponsor the first of these workshops. Results of an end-use monitoring study of a bank branch conducted by PNNL are also presented for purposes of illustrating the need for better data in energy savings modeling (DOE 2013a).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active Learning Framework for Non-Intrusive Load Monitoring: Preprint

Non-Intrusive Load Monitoring (NILM) is a set of techniques that estimate the electricity usage of individual appliances from power measurements taken at a limited number of locations in a building. One of the key challenges in NILM is having too much data without class labels yet being unable to label the data manually for cost or time constraints. This paper presents an active learning framework that helps existing NILM techniques to overcome this challenge. Active learning is an advanced machine learning method that interactively queries a user for the class label information. Unlike most existing NILM systems that heuristically request user inputs, the proposed method only needs minimally sufficient information from a user to build a compact and yet highly representative load signature library. Initial results indicate the proposed method can reduce the user inputs by up to 90% while still achieving similar disaggregation performance compared to a heuristic method. Thus, the proposed method can substantially reduce the burden on the user, improve the performance of a NILM system with limited user inputs, and overcome the key market barriers to the wide adoption of NILM technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-Intrusive Load Monitoring of HVAC Components using Signal Unmixing

Heating, Ventilating and Air Conditioning units (HVAC) are a major electrical energy consumer in buildings. Monitoring of the operation and energy consumption of HVAC would increase the awareness of building owners and maintenance service providers of the condition and quality of performance of these units, enabling conditioned-based maintenance which would help achieving higher energy efficiency. In this paper, a novel non-intrusive load monitoring method based on group constrained non-negative matrix factorization is proposed for monitoring the different components of HVAC unit by only measuring the whole building aggregated power signal. At the first level of this hierarchical approach, power consumption of the building is decomposed to energy consumption of the HVAC unit and all the other electrical devices operating in the building such as lighting and plug loads. Then, the estimated power signal of the HVAC is used for estimating the power consumption profile of the HVAC major electrical loads such as compressors, condenser fans and indoor blower. Experiments conducted on real data collected from a building testbed maintained at the Oak Ridge National Laboratory (ORNL) demonstrate high accuracy on the disaggregation task.

Flexible Research Platform↗

Flaming Moe

Current clamp measurements collected on various small electronic devices. Details on the data set can be found in J. M. Vann, T. P. Karnowski, R. Kerekes, C. D. Cooke and A. L. Anderson, A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions, in IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 1, pp. 122-131, Feb. 2018, doi: 10.1109/TEMC.2017.2692962.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Non-Intrusive Load Monitoring of EBW Processes A Second Study [Slides]

The Objective is to Determine if induced off-nominal welding disturbances: (1) Beam arc out (weld on high vapor pressure aluminum plate); (2) Pulsed beam voltage; (3) Pulsed beam current; and (4) Pulsed beam focus current can be observed in the input power to the high-voltage cabinet powering the EB gun, ie Non-Instrusive Load Monitoring (NILM).

36 MATERIALS SCIENCE↗

Non-Intrusive Appliance Identification with Appliance-Specific Networks

The problem of noninstrusive load monitoring (NILM) is usually formulated as a single-channel blind source separation task, whose successful solution enable fast and convenient load identification and energy disaggregation. When applied at test time, NILM algorithms aim to identify the operating characteristics of individual appliances from an aggregate power measurement of the entire house. Recent advances in deep learning gave rise to many methods that mostly focus on learning a direct mapping from aggregate measurement to individual appliance power. However, these methods are not only computationally expensive, but they often suffer from overfitting and do not generalize very well. In this article, we propose a novel NILM method that leverages advances in statistical learning that have not been properly applied in this domain before. The proposed method consists of three stages: first, a Bayesian nonparametric learning-based approach for appliance state extraction; second, synthetic minority oversampling technique for data augmentation and mitigating the heavy imbalance in switching events; and third, appliance-specific lightweight long short-term memory networks for status classification for each appliance. Here, we adopt a “differential” input (the difference before and after the switching event) to reduce the complexity of network training and make the proposed method robust to multiappliance switching events. Experiments are conducted to demonstrate the effectiveness of the proposed method, achieving superior performance when compared to recent methods. An ablation study is conducted to demonstrate the effectiveness of each module of our method. Finally, we investigate the quality of generated synthetic samples.

42 ENGINEERING↗

Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

Unlike sub-metering, which requires that individual loads are equipped with their own meters, nonintrusive load monitors (NILM) use algorithms to discern the individual loads from a single metering point. Although a number of these technologies are now commercially available to utilities and homeowners, with several more to become available in the coming years, it is not yet understood how accurately these technologies can disaggregate a home’s electrical load. Pacific Northwest National Laboratory (PNNL) and its partners at the Northwest Energy Efficiency Alliance (NEEA) have identified and acquired six of these technologies and will be testing them in the PNNL Lab Homes as well as the owner-occupied Residential Test Bed operated by NEEA. As a result of this testing, PNNL and NEEA will evaluate the selected NILMs against a repeatable test protocol so that their accuracy can be compared across NILM technologies. In the field deployment in the NEEA Test Bed Homes, PNNL and NEEA will evaluate the real-world accuracy of the NILMs responding to dynamic loads. To evaluate the accuracy of NILM technologies regardless of their intended application, a standardized test protocol is required that applies representative loads and establishes consistent metrics against which the NILM can be evaluated and compared. To establish this standardized test protocol, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

NILM↗

Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

47 OTHER INSTRUMENTATION↗