Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Qubit noise deconvolution

We present a noise deconvolution technique to remove a wide class of noises when performing arbitrary measurements on qubit systems. In particular, we derive the inverse map of the most common single qubit noisy channels, and exploit it at the data processing step to obtain noise-free estimates of observables evaluated on a qubit system subject to known noise. We illustrate a self-consistency check to ensure that the noise characterization is accurate providing simulation results for the deconvolution of a generic Pauli channel, as well as experimental evidence of the deconvolution of decoherence noise occurring on Rigetti quantum hardware.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiqubit noise deconvolution and characterization

We present a noise deconvolution technique for obtaining noiseless expectation values of noisy observables at the output of multiqubit quantum channels. For any number of qubits or in the presence of correlations, our protocol applies to any mathematically invertible noise model, even when its inverse map is not physically implementable, i.e., when it is neither completely positive nor trace preserving. For a generic observable affected by Pauli noise it provides a quadratic speedup, always producing a rescaling of its Pauli basis components. We show that it is still possible to achieve the deconvolution while experimentally estimating the noise parameters, whenever these are unknown (bypassing resource-heavy techniques such as quantum process tomography). We provide a simulation, with examples for both Pauli and non-Pauli channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-images deconvolution improves signal-to-noise ratio on gated stimulated emission depletion microscopy

Time-gated detection, namely, only collecting the fluorescence photons after a time-delay from the excitation events, reduces complexity, cost, and illumination intensity of a stimulated emission depletion (STED) microscope. In the gated continuous-wave- (CW-) STED implementation, the spatial resolution improves with increased time-delay, but the signal-to-noise ratio (SNR) reduces. Thus, in sub-optimal conditions, such as a low photon-budget regime, the SNR reduction can cancel-out the expected gain in resolution. Here, we propose a method which does not discard photons, but instead collects all the photons in different time-gates and recombines them through a multi-image deconvolution. Our results, obtained on simulated and experimental data, show that the SNR of the restored image improves relative to the gated image, thereby improving the effective resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DeconTools

DeconTools is a software package used for detecting features in MS data by using the isotopic signatures of expected components. The tool uses different algorithms for different parts of the deconvolution process: noise reduction, peak detection, prediction of theoretical isotopic envelope and scoring functions that quantitate the quality of signature observed in the data.

Crowell, Kevin↗

SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation

Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used to recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.

60 APPLIED LIFE SCIENCES↗

X-ray atomic absorption of cesium and xenon in the L-edge region

X-ray absorption of atomic cesium is measured in the L-edge region, using a beryllium-window cell for cesium vapor. For comparison, absorption in Xe gas in the same energy region is remeasured with improved signal-to-noise ratio. By combining deconvolution and modeling, the edge profiles are studied to determine the threshold energies and the shape of the edge apex with exponential slope of the high-energy flank. In both elements, multielectron excitations show the same basic ordering in compact groups, largely independent of the core-hole subshell, following the energy sequence of coexcited valence and subvalence orbitals. The main effect of 6s electron in Cs, apart from 2(s,p)6s excitation, is the enhancement of single- as well as some multielectron resonant channels. The spectra of both elements show the ''polarization effect'': a convex basic curvature of the L{sub 2} and L{sub 3} segments, a concave L{sub 1} segment. Previously, Kutzner demonstrated a convincing theoretical explanation of the effect on Xe in a relativistic random-phase approximation with relaxation involving overlap integrals with continuum [Rad. Phys. Chem. 70, 95 (2004)].

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-C-207A-04: Accuracy of Acoustic-Based Proton Range Verification in Water

Purpose: To determine the accuracy and dose required for acoustic-based proton range verification (protoacoustics) in water. Methods: Proton pulses with 17 µs FWHM and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 8.9 cGy/pulse) were generated by a clinical, hospital-based cyclotron at the University of Pennsylvania. The protoacoustic signal generated in a water phantom by the 190 MeV proton pulses was measured with a hydrophone placed at multiple known positions surrounding the dose deposition. The background random noise was measured. The protoacoustic signal was simulated to compare to the experiments. Results: The maximum protoacoustic signal amplitude at 5 cm distance was 5.2 mPa per 1 × 10{sup 7} protons (1.6 cGy at the Bragg peak). The background random noise of the measurement was 27 mPa. Comparison between simulation and experiment indicates that the hydrophone introduced a delay of 2.4 µs. For acoustic data collected with a signal-to-noise ratio (SNR) of 21, deconvolution of the protoacoustic signal with the proton pulse provided the most precise time-of-flight range measurement (standard deviation of 2.0 mm), but a systematic error (−4.5 mm) was observed. Conclusion: Based on water phantom measurements at a clinical hospital-based cyclotron, protoacoustics is a potential technique for measuring the proton Bragg peak range with 2.0 mm standard deviation. Simultaneous use of multiple detectors is expected to reduce the standard deviation, but calibration is required to remove systematic error. Based on the measured background noise and protoacoustic amplitude, a SNR of 5.3 is projected for a deposited dose of 2 Gy.

60 APPLIED LIFE SCIENCES↗

Radiation Mapping for an Unmanned Aerial Vehicle: Development and Simulated Testing of Algorithms for Source Mapping and Navigation Path Generation

Image reconstruction algorithms were developed for radiation source mapping and used for generating the search path of a moving radiation detector, such as one onboard an unmanned aerial vehicle. Simulations consisted of first assuming radioactive sources of varying complexity and estimating the radiation fields that would then be produced by that source distribution. Next, the "measurements" that would result from a pair of adjacent spatial locations were computed. A crude estimate of the source distribution likely to have produced such "measurements" was reconstructed based upon the limited measurements. Location of the next "measurement" was then determined as halfway between the location of the estimated source and the current "measurement." With each additional sample, improved source distribution reconstructions were made and used to inform the immediate direction of detector motion. Source reconstruction or mapping was formulated as an inverse problem solved with either maximum a posteriori or least squares (LS) regression deconvolution methods. Different amounts of noise were added to the simulated "measurements," allowing evaluation of the methods' performances as functions of signal-to-noise ratio of the measured map. As expected, methods that promote sparsity were better suited in reconstructing point sources. Reliable prior information of the source distribution also improved the reconstruction results, especially with distributed sources. With a non-negative least square algorithm and the suggested paths it generated, location of sources was successfully estimated to an accuracy of 0.014 m within nine iterations in a single-source scenario and 12 iterations in a two-source scenario, given a 10% error on the integrated counts and a Poisson distribution of the noise associated with the measured counts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction

Purpose: Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy–Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. Methods: The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy–Richardson deconvolution algorithm to the current estimation of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Results: Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. Conclusions: This study demonstrates the feasibility of incorporating the Lucy–Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RISE: robust iterative surface extension for sub-nanometer X-ray mirror fabrication

Precision optics have been widely required in many advanced technological applications. X-ray mirrors, as an example, serve as the key optical components at synchrotron radiation and free electron laser facilities. They are rectangular silicon or glass substrates where a rectangular Clear Aperture (CA) needs to be polished to sub-nanometer Root Mean Squared (RMS) to keep the imaging capability of the incoming X-ray wavefront at the diffraction limit. The convolutional polishing model requires a CA to be extended with extra data, from which the dwell time is calculated via deconvolution. However, since deconvolution is very sensitive to boundary errors and noise, the existing surface extension methods can hardly fulfill the sub-nanometer requirement. On one hand, the figure errors in a CA were improperly modeled during the extension, leading to continuity issues along the boundary. On the other hand, uncorrectable high-frequency errors and noise were also extended. In this study, we propose a novel Robust Iterative Surface Extension (RISE) method that resolves these problems with a data fitting strategy. RISE models the figure errors in a CA with orthogonal polynomials and ensures that only correctable errors are fit and extended. Combined with boundary conditions, an iterative refinement of dwell time is then proposed to compensate the errors brought by the extension and deconvolution, which drastically reduces the estimated figure error residuals in a CA while the increase of total dwell time is negligible. To our best knowledge, RISE is the first data fitting-based surface extension method and is the first to optimize dwell time based on iterative extension. An experimental verification of RISE is given by fabricating two elliptic cylinders (10 mm × 80 mm CAs) starting from a sphere with a radius of curvature around 173 m using ion beam figuring. The figure errors in the two CAs greatly improved from 204.96 nm RMS and 190.28 nm RMS to 0.62 nm RMS and 0.71 nm RMS, respectively, which proves that RISE is an effective method for sub-nanometer level X-ray mirror fabrication.

36 MATERIALS SCIENCE↗

Mammograms restoration by using Wiener filter

Restoration of digital mammograms, as a pre-processing tool, using deconvolution procedures, is analysed. It implies, knowing Modulation Transfer Function (MTF) of the mammography device and the estimation of the mammogram’s noise. Wiener filter is used, as the most objective in mammograms restoration by deconvolution. Using MATLAB program the deconvolution procedures are conducted in two ways with different level of approximation. The first method approximates the noise/signal power ratio by a constant and the second method uses autocorrelation functions of the noise and signals. Abilities and limitations of the methods are analysed and checked by using the raw images of the bar-pattern due to better visualisation of the obtained results. The raw images are obtained at a Computed Radiography (CR) mammography device in Clinical Centre in Podgorica. It is found that quality of the restored image highly depends of knowledge of type and magnitude of noise. In the both methods spatial resolution of the restored images are improved, but much better in a case where autocorrelation functions of the noise and signal are used. This procedure is proposed as an objective pre-processing tool to put back imperfectness of mammography devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transient recovery problem in acoustics: A multichannel model-based deconvolution approach

Critical acoustical systems operating in complex environments contaminated with disturbances and noise offer an extreme challenge when excited by out-of-the-ordinary, impulsive, transient events that can be undetected and seriously affect their overall performance. Transient impulse excitations must be detected, extracted, and evaluated to determine any potential system damage that could have been imposed; therefore, the problem of recovering the excitation in an uncertain measurement environment becomes one of multichannel deconvolution. Recovering a transient and its initial energy has not been solved satisfactorily, especially when the measurement has been truncated and only a small segment of response data is available. The development of multichannel deconvolution techniques for both complete and incomplete excitation data is discussed, employing a model-based approach based on the state-space representation of an identified acoustical system coupled to a forward modeling solution and a Kalman-type processor for enhancement and extraction. In conclusion, synthesized data are utilized to assess the feasibility of the various approaches, demonstrating that reasonable performance can be achieved even in noisy environments.

42 ENGINEERING↗

Practical considerations in using a binary pseudorandom array for instrument transfer function calibration

Binary pseudo-random array (BPRA) artifacts are useful devices for calibrating the instrument transfer function (ITF) of interferometric microscopes and other optical and non-optical surface and wavefront measurement instruments. The intrinsic white noise character of the power spectral density function of the artifact simplifies the deconvolution of the ITF from the measured power spectral density (PSD). However, resampling of the BPRA intrinsic artifact features with the measurement tool's specific sampling pattern modifies the white noise character of the intrinsic spectrum and needs to be accounted for in the ITF-based data deconvolution process. We have developed an analytic solution to the spectrum of a resampled one- and two- dimensional BPRA. The resultant nominal PSD function is a simple twoparameter cosine function with a period equal to the resampled pixel width. A transfer function model for interferometric microscopes that incorporates this function, along with an ITF that includes aliasing effects and variable numerical aperture (NA), wavelength, and obscuration factor, is used to fit to the BPRA PSDs measured by an interference microscope for a range of objective and zoom lens magnification combinations.

Takacs, PZ↗

Improved deconvolution of very weak confocal signals

Deconvolution is typically used to sharpen fluorescence images, but when the signal-to-noise ratio is low, the primary benefit is reduced noise and a smoother appearance of the fluorescent structures. 3D time-lapse (4D) confocal image sets can be improved by deconvolution. However, when the confocal signals are very weak, the popular Huygens deconvolution software erases fluorescent structures that are clearly visible in the raw data. We find that this problem can be avoided by prefiltering the optical sections with a Gaussian blur. Analysis of real and simulated data indicates that the Gaussian blur prefilter preserves meaningful signals while enabling removal of background noise. This approach is very simple, and it allows Huygens to be used with 4D imaging conditions that minimize photodamage .

Day, Kasey J.↗

Improved deconvolution of very weak confocal signals

Deconvolution is typically used to sharpen fluorescence images, but when the signal-to-noise ratio is low, the primary benefit is reduced noise and a smoother appearance of the fluorescent structures. 3D time-lapse (4D) confocal image sets can be improved by deconvolution. However, when the confocal signals are very weak, the popular Huygens deconvolution software erases fluorescent structures that are clearly visible in the raw data. We find that this problem can be avoided by prefiltering the optical sections with a Gaussian blur. Analysis of real and simulated data indicates that the Gaussian blur prefilter preserves meaningful signals while enabling removal of background noise. This approach is very simple, and it allows Huygens to be used with 4D imaging conditions that minimize photodamage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam Signal Recovery Using Wiener Deconvolution

This project explores the use of Wiener deconvolution to recover an original signal that has been distorted by a known transfer function and by noise. A simulated Gaussian pulse was used as the test signal, and a transfer function was applied in the frequency domain to model system distortion. Controlled noise was then introduced to approximate real-world signal degradation. A Wiener filter was implemented to reverse the effects of the transfer function while minimizing the influence of noise. The recovered signal was compared to the original pulse to evaluate the effectiveness of the filter. Results demonstrate that Wiener deconvolution offers a stable and effective approach to signal recovery, balancing complete transfer function inversion and noise suppression.

Campbell, Savanna [El Camino Coll.]↗