Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron spectrum unfolding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data Augmentation for Neutron Spectrum Unfolding with Neural Networks

Neural networks require a large quantity of training spectra and detector responses in order to learn to solve the inverse problem of neutron spectrum unfolding. In addition, due to the under-determined nature of unfolding, non-physical spectra which would not be encountered in usage should not be included in the training set. While physically realistic training spectra are commonly determined experimentally or generated through Monte Carlo simulation, this can become prohibitively expensive when considering the quantity of spectra needed to effectively train an unfolding network. In this paper, we present three algorithms for the generation of large quantities of realistic and physically motivated neutron energy spectra. Using an IAEA compendium of 251 spectra, we compare the unfolding performance of neural networks trained on spectra from these algorithms, when unfolding real-world spectra, to two baselines. We also investigate general methods for evaluating the performance of and optimizing feature engineering algorithms.

McGreivy, James (ORCID:0000000321723411)↗

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimising Foil Selection for Neutron Activation Systems

Abstract Neutron spectrum unfolding using activation foils is currently the primary technique planned for measuring the neutron energy spectrum at the first wall of power-generating fusion reactors. Room for improvement in the effectiveness of current foil selection was identified, and a program produced to select foils procedurally in order to maximise the accuracy of the unfolding procedure. Using Kullback–Leibler Divergence to quantify the accuracy, the spectrum unfolded by the procedurally selected set of foils is found to be more accurate than the spectrum unfolded by a set of foils used in the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Neutron Fluence and Kerma Responses to Bare, Steel-Reflected, and Lucite-Reflected Steady-State Operations of the ORNL Health Physics Research Reactor

The experiments evaluated in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the Fast Burst Reactor. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. In this evaluation, a total of 12 experiments were evaluated (6 shield configurations and two responses). Six of them are considered acceptable as benchmark experiments and are thoroughly described: the measurands are bare, steel-shielded and Lucite-shielded neutron fluences and neutron KERMA responses to steady-state operations of the HPRR. It is important to mention that there is a general lack of information in the experimental methodology and neutron spectrum unfolding, and in some cases, unexpected and unexplained discrepancies between calculation and experiment. The HPRR’s unique characteristics were that it is a fast reactor, the use of a Lucite shield as the shielding material, and the use of the neutron fluence as the main benchmark measurand. There are no known, significant correlations between benchmarks in this evaluation and benchmarks in other evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and description of a spectrum unfolding method for the $\mathrm{CATRiNA}$ neutron detector array

We report the CATRiNA deuterated neutron detector array at Florida State University consists of 16 2" x 2" and 16 $" x 2" EJ-315 detectors with characteristic light output and pulse-shape discrimination capabilities. The unique properties of the detectors, in part due to the anisotropic nature of (d,n) scattering, are used to extract the energy of neutrons via pulse-height spectrum unfolding. The unfolding method uses the light output and response matrix of the detectors to extract neutron energies, independent of the traditional time-of-flight (ToF) technique. Detailed response matrices of the CATRiNA detectors were measured at the Edwards Accelerator Laboratory at Ohio University via the 9 Be(d,n) and 27 Al(d,n) reactions. Full characterization of the detectors using digital electronics, as well as a description of the unfolding method are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Level Neutron Spectroscopy

Although the most sought-after hot plasma fusion reactions use deuterium-tritium due to its higher fusion cross-section, the deuteron-deuteron fusion reaction is also used and is suspected in Low Energy Nuclear Reactions (LENR). Although LENR reactions are largely aneutronic, the D(d,n)3He reaction produces a 2.45 MeV kinetic energy neutron. In the course of fusion experiments at NASA, ranging from bremsstrahlung photoneutron-initiated fusion to Pd/D co-deposition, we’ve made use of liquid and solid neutron scintillator spectrometers, bubble detectors and Solid State Nuclear Track Detectors (CR-39). We have observed the unfolded neutron energy spectrum from primary fusion and boosted fusion or stripped neutrons from photoneutron induced fusion. Despite an average deuteron energy of 64 keV, the peak unfolded neutron flux was only a few neutrons/minute. The major problem was the 10e14vgamma ray/neutrons/second flux ratio.

Neutron spectroscopy↗

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of particle-dependent light response for defining detector response functions

This study comprehensively characterizes two scintillation detectors, an organic deuterated liquid and a stilbene crystal, concerning their response to charged particles such as electrons, protons, alphas, and carbon nuclei. The Birks function was used to determine the detectors’ response to charged particles, enabling the determination of particle-dependent light responses. The particle-dependent light characterization was used to determine detector response functions (DRF) using Geant in combination with Gamma Detector Response and Analysis Software (GADRAS). These DRFs enhance GADRAS by enabling full spectral analysis functionality for previously underrepresented detector materials. Additionally, neutron-specific DRFs are determined for neutron energy spectrum unfolding applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗