Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Interrogation Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fieldable Nuclear Material Identification System

The Fieldable Nuclear Material Identification System (FNMIS), funded by the NA-241 Office of Dismantlement and Transparency, provides information to determine the material attributes and identity of heavily shielded nuclear objects. This information will provide future treaty participants with verifiable information required by the treaty regime. The neutron interrogation technology uses a combination of information from induced fission neutron radiation and transmitted neutron imaging information to provide high confidence that the shielded item is consistent with the host's declaration. The combination of material identification information and the shape and configuration of the item are very difficult to spoof. When used at various points in the warhead dismantlement sequence, the information complimented by tags and seals can be used to track subassembly and piece part information as the disassembly occurs. The neutron transmission imaging has been developed during the last seven years and the signature analysis over the last several decades. The FNMIS is the culmination of the effort to put the technology in a usable configuration for potential treaty verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active-Interrogation Measurements of Induced-Fission Neutrons from Low-Enriched Uranium

Protection and control of nuclear fuels is paramount for nuclear security and safeguards; therefore, it is important to develop fast and robust controlling mechanisms to ensure the safety of nuclear fuels. Through both passive- and active-interrogation methods we can use fast-neutron detection to perform real-time measurements of fission neutrons for process monitoring. Active interrogation allows us to use different ranges of incident neutron energy to probe for different isotopes of uranium. With fast-neutron detectors, such as organic liquid scintillation detectors, we can detect the induced-fission neutrons and photons and work towards quantifying a sample’s mass and enrichment. Using MCNPX-PoliMi, a system was designed to measure induced-fission neutrons from U-235 and U-238. Measurements were then performed in the summer of 2010 at the Joint Research Centre in Ispra, Italy. Fissions were induced with an associated particle D-T generator and an isotopic Am-Li source. The fission neutrons, as well as neutrons from (n, 2n) and (n, 3n) reactions, were measured with five 5” by 5” EJ-309 organic liquid scintillators. The D-T neutron generator was available as part of a measurement campaign in place by Padova University. The measurement and data-acquisition systems were developed at the University of Michigan utilizing a CAEN V1720 digitizer and pulse-shape discrimination algorithms to differentiate neutron and photon detections. Low-enriched uranium samples of varying mass and enrichment were interrogated. Acquired time-of-flight curves and cross-correlation curves are currently analyzed to draw relationships between detected neutrons and sample mass and enrichment. In the full paper, the promise of active-interrogation measurements and fast-neutron detection will be assessed through the example of this proof-of-concept measurement campaign. Additionally, MCNPX-PoliMi simulation results will be compared to the measured data to validate the MCNPX-PoliMi code when used for active-interrogation simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Layered shielding design for an active neutron interrogation system

The use of source and detector shields in active neutron interrogation can improve detector signal. In simulations, a shielded detector with a source rotated π/3 rad relative to the opening decreased neutron flux roughly three orders of magnitude. Several realistic source and detector shield configurations were simulated. A layered design reduced neutron and secondary photon flux in the detector by approximately one order of magnitude for a deuterium–tritium source. The shield arrangement can be adapted for a portable, modular design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric Evaluation of Active Neutron Interrogation for the Detection of Shielded Highly-Enriched Uranium in the Field

Parametric studies using numerical simulations are being performed to assess the performance capabilities and limits of active neutron interrogation for detecting shielded highly enriched uranium (HEU). Varying the shield material, HEU mass, HEU depth inside the shield, and interrogating neutron source energy, the simulations account for both neutron and photon emission signatures from the HEU with resolution in both energy and time. The results are processed to represent different irradiation timing schemes and several different classes of radiation detectors, and evaluated using a statistical approach considering signal intensity over background. This paper describes the details of the modeling campaign and some preliminary results, weighing the strengths of alternative measurement approaches for the different irradiation scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Neutron Interrogation as a Method for Verification of the Absence of Special Nuclear Material in Arms Control Dismantlement

The next step in arms control reductions will deal with both strategic and non-strategic weapons, presenting new and hard challenges for verification. One verification approach that might be used in support of these reductions is the concept of deferred verification, which forgoes inspections at sensitive nuclear sites and relies on an inspection regime having access to the open segment of a State's nuclear sector, in "monitored transfer zones." A component of this approach is the anticipated need for an instrument suite capable of detecting well-shielded highly-enriched uranium or plutonium where it isn't supposed to be. This specific need was recently identified by the United Nations Institute for Disarmament Research in an enabling operating concept they call "contain and dispose." At the foundation of this approach is the idea that items declared as "not nuclear" are, by definition, not treaty limited and are thus "fair-game" for inspection and questioning. Active Neutron Interrogation (ANI), using beta-delayed neutron emissions as the signature for special nuclear material (SNM) detection, is a promising method to address this challenge. The method is quick, has high sensitivity and high specificity for detecting shielded SNM, is robust against changing background radiation environments, is robust against the presence of unknown shielding, and avoids the use of gamma-ray spectrometry which may introduce complications due to the potential release of sensitive information. This paper will present recent research activities exploring technical aspects of using ANI as a FAIRGAME verification method and discuss future prospects and research needs

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Estimation of the Performance of Multiple Active Neutron Interrogation Signatures for Detecting Shielded HEU

A comprehensive modeling study has been carried out to evaluate the utility of multiple active neutron interrogation signatures for detecting shielded highly enriched uranium (HEU). The modeling effort focused on varying HEU masses from 1 kg to 20 kg; varying types of shields including wood, steel, cement, polyethylene, and borated polyethylene; varying depths of the HEU in the shields, and varying engineered shields immediately surrounding the HEU including steel, tungsten, and cadmium. Neutron and gamma-ray signatures were the focus of the study and false negative detection probabilities versus measurement time were used as a performance metric. To facilitate comparisons among different approaches an automated method was developed to generate receiver operating characteristic (ROC) curves for different sets of model variables for multiple background count rate conditions. This paper summarizes results or the analysis, including laboratory benchmark comparisons between simulations and experiments. The important impact engineered shields can play towards degrading detectability and methods for mitigating this will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed Gamma-ray Assay for Nuclear Materials Safeguards. Comprehensive Technology Readiness Assessment

Spectroscopic analysis of beta-delayed gamma-rays emitted from fission products following active interrogation was investigated as a non-destructive assay technique for detection and characterization of nuclear materials in shielded and complex configurations. This measurement technique is expected to be applicable to a variety of applications within the nuclear material safeguards, arms control, and emergency response areas, where active neutron interrogation is acceptable. Potential applications of the delayed gamma-ray assay in the nuclear material safeguards area include characterization of U and Pu isotopic content in spent and unirradiated nuclear fuel, enrichment measurements, verification of bulk material in containers, and the characterization of nuclear wastes. In the arms control area, this method can be used as a part of warhead dismantlement measurements to confirm separation of components, and may be applicable in warhead confirmation. In the context of emergency response, it can be used for detailed diagnostics of an unknown item. At present, the delayed gamma-ray assay technology reliably qualifies for the Technical Readiness Level 3 (TRL 3). The R&D work completed under this project has successfully demonstrated the empirical proof-of-concept for this active interrogation technology for a variety of measurement configurations, neutron sources, and nuclear material samples. A robust first-principles analytical signature modeling methodology was developed, experimentally validated, and can be easily extrapolated to a range of realistic measurement scenarios. Several response analysis methodologies have been implemented and deemed reliable for a variety of active interrogation applications in the areas of nuclear material safeguards, arms control, and emergency response. The initial readiness level before the start of this project was assessed at TRL 0, since only fragmentary records of the signature observations and speculative statements of the relevant non-destructive assay applications existed at that time. The delayed gamma-ray technology readiness can be easily advanced to TRL 4 in a short period, if a certain measurement application is specified and set for a demonstration in a laboratory environment. The critical hardware components of the delayed gamma-ray measurement technology (neutron generators, gamma-ray spectrometers) are readily available as COTS and can be configured for a specific deployment configuration. The primary risk of the delayed gamma-ray assay methodology is defined by the applicationspecific uncertainties. Evaluation of the system performance can be effectively completed once the expected measurement purpose, nuclear material characteristics, dimensions, and radiation exposure constraints are specified. A minor risk can be associated with the delayed gamma-ray response analysis techniques. Several approaches were proposed and demonstrated primarily using the modeled signatures. The observed performance may not be easily transferrable to the conditions of a real measurement setup, and some additional R&D may be required. Overall, the delayed gamma-ray assay technology can be recommended for follow-up demonstrations addressing relevant measurement applications in the areas of nuclear material safeguards, arms control, and emergency response.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detectors for Active Interrogation Applications

Active interrogation creates an environment that is particularly challenging from a radiation-detection standpoint: the elevated background levels from the source can mask the desired signatures from the SNM. Neutron based interrogation experiments have shown that nanosecond-level timing is required to discriminate induced-fission neutrons from the scattered source neutrons. Previous experiments using high-energy bremsstrahlung X-rays have demonstrated the ability to induce and detect prompt photofission neutrons from single target materials; however, a real-world application would require spectroscopic capability to discern between photofission neutrons emitted by SNM and neutrons emitted by other reactions in non-SNM. Using digital pulseshape discrimination, organic liquid scintillators are capable of reliably detecting neutrons in an intense gamma-ray field. Photon misclassification rates as low as 1 in 10 6 have been achieved, which is approaching the level of gaseous neutron detectors such as 3 He without the need for neutron moderation. These scintillators also possess nanosecond-timing resolution, making them candidates for both neutron-and photon-driven active interrogation systems. Lastly, we have applied an array of liquid and NaI(Tl) scintillators to successfully image 13.7 kg of HEU interrogated by a DT neutron generator; the system was in the direct presence of the accelerator during the experiment.

36 MATERIALS SCIENCE↗

Variations in AmLi source spectra and their estimation utilizing the 5 Ring Multiplicity Counter

Active-mode assay systems are widely used for the safeguards of uranium items to verify compliance with the Non-Proliferation Treaty. Systems such as the Active-Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL) use americium-lithium (AmLi) neutron sources to induce fissions which are measured to determine the sample mass. These systems have historically relied on calibrations derived from well-defined standards. Recently, restricted access to standards or more difficult measurements have resulted in a reliance on modeling and simulation for the calibration of systems, which introduces potential simulation biases. Furthermore, the AmLi source energy spectra commonly used in the safeguards community do not accurately represent measurement results and the spectrum uncertainty can represent a large contribution to the total modeling uncertainty in active-mode systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated Neutron Interrogation Source in the Active Well [Slides]

The Active Well Coincidence Counter (AWCC) is a technology developed by Los Alamos National Laboratories for the use of non-destructive assay of Uranium materials for international nuclear inspectorates such as the IAEA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MPACT FY2011 Advanced Time-Correlated Measurement Research at INL

Simulations and experiments have been carried out to investigate advanced time-correlated measurement methods for characterizing and assaying nuclear material for safeguarding the nuclear fuel cycle. These activities are part of a project studying advanced instrumentation techniques in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control Technologies (MPACT) program. For fiscal year 2011 work focused on examining the practical experimental aspects of using a time-tagged, associated-particle electronic neutron generator for interrogating low-enrichment uranium in combination with steady-state interrogation using a moderated 241Am-Li neutron source. Simulation work for the project involved the use of the MCNP-PoliMi Monte Carlo simulation tool to determine the relative strength and the time-of-flight energy spectra of different sample materials under irradiation. Work also took place to develop a post-processor parser code to extract comparable data from the MCNP5&6 codes. Experiments took place using a commercial deuterium-tritium associated-particle electronic neutron generator to irradiate a number of uranium-bearing material samples. Time-correlated measurements of neutron and photon signatures of these measurements were made using five liquid scintillator detectors in a novel array, using high-speed waveform digitizers for data collection. This report summarizes the experiments that took place in FY2011, presents preliminary analyses that have been carried out to date for a subpart of these experiments, and describes future activities planned in this area. The report also describes support Idaho National Laboratory gave to Oak Ridge National Laboratory in 2011 to facilitate 2-dimensional imagery of mixed-oxide fuel pins for safeguards applications as a part of the MPACT program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Associated Particle Tagging (APT) in Magnetic Spectrometers

Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI).

Jordan, David V.↗