Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Die-Away”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design of Premoderated Pulsed-Neutron Die-Away Experiments for Validating Beryllium Thermal Neutron Scattering Laws

Accurate thermal scattering laws (TSLs) are essential for reliable neutron transport simulations, particularly for systems with low-energy neutrons. Pulsed-neutron die-away (PNDA) experiments provide a highly sensitive platform for TSL validation but face challenges from fast neutron leakage and material constraints in nonhydrogenous targets such as beryllium. This work investigates the use of high-density polyethylene (HDPE) as a premoderator to reduce leakage, improve thermalization, and shorten experimental run times while preserving sensitivity to the Be TSL. Here, three premoderated configurations, encapsulation, slab, and interstitial, were evaluated using MCNP6.3® simulations with ENDF/B-VIII.0 nuclear data. The effects of the Be TSL was quantified by comparing decay constants from simulations with and without 𝑆⁡(𝛼,𝛽) treatments for both beryllium and HDPE. The results show that premoderation enables the use of as little as 5.20% of the beryllium volume required for an unreflected geometry, achieving uncertainties below 0.5% and reducing run time by up to 72.2% in the studied configurations. The interstitial configuration achieved the best balance between low statistical uncertainty and high TSL sensitivity, outperforming the slab and encapsulation designs. These findings demonstrate that carefully optimized premoderation can significantly enhance the efficiency, feasibility, and precision of PNDA experiments for Be TSL validation.

Integral Experiments↗

Pulsed-Neutron Die-Away Response of H 2 O Targets to a D-T Neutron Generator Pulse

Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target.

3He Detectors↗

Pulsed-Neutron Die-Away Response of H 2 O Targets to a D-T Generator Pulse

Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target. The neutrons scattered and thermalized within the target and were counted as a function of time using Helium-3 ( 3 He) detectors that surrounded the target. These data provide a time-decay profile of the neutron population from which the time eigenvalue of the experiment is calculated. The time eigenvalue quantity α represents the integral parameter of interest. This report describes the measurements for H 2 O targets. The measurements were conducted over several days beginning on October 23rd, 2023. All measurements were completed at the low-scatter facility at LLNL. The evaluation identifier is FUND-LLNL-DT-H2O-PNDA-001.

3He Detectors↗

IER-620 Pulsed-Neutron Die-Away (PNDA) with Oil Targets, CED3a

The Pulsed-Neutron Die-Away (PNDA) Testbed has previously been used to perform thermal scattering law validation measurements on HDPE and Lucite (IER-501) and water (IER-580). This experimental campaign expands the tests to include three additional hydrogenous materials relevant to various machining operations with fissionable materials. As such, it will use much of the same processes and equipment from the previous PNDA experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-620 Pulsed-Neutron Die-Away (PNDA) with Oil Targets, CED3a

The Pulsed-Neutron Die-Away (PNDA) Testbed has previously been used to perform thermal scattering law validation measurements on HDPE and Lucite (IER-501) and water (IER-580). This experimental campaign expands the tests to include three additional hydrogenous materials relevant to various machining operations with fissionable materials. As such, it will use much of the same processes and equipment from the previous PNDA experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-580 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experiments (PNDA) with H 2 O

This report summarizes new experiments performed with H 2 O for IER-580, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The experiments will become high-quality benchmarksthat serve to optimize and validate thermal neutron scattering laws (TSLs) of H 2 O, which are high-priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). The report presents the details of the measurements conducted in October of 2023, including the experimental set-up (PNDA equipment and H 2 O targets) and all experimentally measured data. The report gives the fitted decay constants for the die-away curves of each target sample. It also provides the tabulated data for the die-away curves in the appendices.

42 ENGINEERING↗

Neutron die-away experiment for remote analysis of the surface of the moon and the planets, phase 3

Continuing work on the two die-away measurements proposed to be made in the combined pulsed neutron experiment (CPNE) for analysis of lunar and planetary surfaces is described. This report documents research done during Phase 3. A general exposition of data analysis by the least-squares method and the related problem of the prediction of variance is given. A data analysis procedure for epithermal die-away data has been formulated. In order to facilitate the analysis, the number of independent material variables has been reduced to two: the hydrogen density and an effective oxygen density, the latter being determined uniquely from the nonhydrogeneous elemental composition. Justification for this reduction in the number of variables is based on a set of 27 new theoretical calculations. Work is described related to experimental calibration of the epithermal die-away measurement. An interim data analysis technique based solely on theoretical calculations seems to be adequate and will be used for future CPNE field tests.

Mills, W. R.↗

IER-620 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experiments (PNDA) with Propylene Glycol and Mobilmet 423

There is a strong need for new benchmarks to validate neutron thermal scattering laws (TSLs). Lawrence Livermore National Laboratory (LLNL) has designed a Pulsed-Neutron Die Away (PNDA) testbed for this purpose. The experiment has a deuterium-tritium (D-T) neutron generator that impinges a 10 -4 s, mono-energetic pulse of 14.1 MeV neutrons on a target sample. After the pulse, the neutron population moderates and establishes a thermal equilibrium within the sample, with a fundamental spatial mode and characteristic decay-time eigenvalue, ⍺. The ⍺ eigenvalue can be extracted from the experimental measurements of the time-dependent neutron flux coming off the surface of the sample and can then be used as an integral parameter (similar to k eff ) to validate nuclear data involved with neutron migration, thermalization, and absorption. For moderating materials and geometric configurations, the ⍺ eigenvalue is heavily dependent on thermal neutron scattering of the target material. For that reason, a PNDA experiment can have a higher sensitivity to TSLs than is commonly available with the k eff parameter in critical experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

Burnup Monitoring for Pebble Bed Reactor Systems

A pebble burnup monitoring system is a required component for domestic reactor safety and safeguards applications associated with pebble bed reactors (PBRs). One of the main requirements of a PBR burnup monitoring system is that it needs to be capable of rapid measurements to assess the burnup of each individual pebble to determine whether to recirculate it in the reactor or discard it as spent fuel. This report considers three different approaches for a burnup monitoring system for pebbles discharged from the reactor core in a pebble bed modular reactor-400: • passive gamma spectrometry measurement, • passive neutron coincidence measurement, and • active neutron counter based on the differential die-away technique. Conceptual designs have been created for each of these detectors, and preliminary analysis has been performed using Monte Carlo N-Particle and Oak Ridge Isotope Generation code simulations. The advantages and practical limitations (e.g., high radiation background) of each system were identified. Simulations suggest that each of the three measurement techniques can be successfully employed to distinguish between pebbles based on their number of passes through the core and to quantify the burnup of pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗