Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Aerial Neutron Detection: Neutron Signatures for Nonproliferation and Emergency Response Applications

From 2007 to the present, the Remote Sensing Laboratory has been conducting a series of studies designed to expand our fundamental understanding of aerial neutron detection with the goal of designing an enhanced sensitivity detection system for long range neutron detection. Over 35 hours of aerial measurements in a helicopter were conducted for a variety of neutron emitters such as neutron point sources, a commercial nuclear power reactor, nuclear reactor spent fuel in dry cask storage, depleted uranium hexafluoride and depleted uranium metal. The goals of the project were to increase the detection sensitivity of our instruments such that a 5.4 × 104 neutron/second source could be detected at 100 feet above ground level at a speed of 70 knots and to enhance the long-range detection sensitivity for larger neutron sources, i.e., detection ranges above 1000 feet. In order to increase the sensitivity of aerial neutron detection instruments, it is important to understand the dynamics of the neutron background as a function of altitude. For aerial neutron detection, studies have shown that the neutron background primarily originates from above the aircraft, being produced in the upper atmosphere by galactic cosmic-ray interactions with air molecules. These interactions produce energetic neutrons and charged particles that cascade to the earth’s surface, producing additional neutrons in secondary collisions. Hence, the neutron background increases as a function of altitude which is an impediment to long-range neutron detection. In order to increase the sensitivity for long range detection, it is necessary to maintain a low neutron background as a function of altitude. Initial investigations show the variation in the neutron background can be decreased with the application of a cosmic-ray shield. The results of the studies along with a representative data set are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Materials and Devices for Solid-State Neutron Detection

Neutron sensing is critical in civilian, military, industrial, biological, medical, basic research, and environmental applications. Conventional neutron sensors are limited by size, weight, cost, portability, and helium supply. Here the microfabrication of Gd conversion material-based heterojunction diodes is described for detecting thermal neutrons using electrical signals produced by internal conversion electrons (ICE). Films with negligible stress were produced at the tensile-compressive crossover point, enabling Gd coatings of any desired thickness by controlling the radiofrequency sputtering power and using the zero-point near p(Ar) of 50 mTorr at 100 W. Post-deposition Gd oxidation-induced spallation was eliminated by growing a residual stress-free 50 nm neodymium-doped aluminum cap layer atop Gd. Resultant coatings were stable for at least six years demonstrating excellent product shelf life. Depositing Gd on the diode surface eliminated air gap, leading to improved efficiency and facilitating monolithic microfabrication. The conversion electron spectrum was dominated by ICE with energies of 72, 132, and 174 keV. Results are reported on neutron reflection and moderation by polyethylene for enhanced sensitivity and γ- and X-ray elimination for improved specificity. Optimal Gd thickness was 10.4 μm with 300 μm thick partially depleted diode of 300 mm2 active surface area. Fast detection within 10 minutes at a neutron source-to-diode distance of 11.7 cm was achieved using this configuration. All ICE energies along with γ-ray and Kα X-ray were modeled to emphasize correlations between experiment and theory and to calculate efficiencies. Semiconductor thermal neutron detectors offer advantages for field-sensing of radioactive neutron sources.

47 OTHER INSTRUMENTATION↗

Neutron detection in a high gamma ray background with liquid scintillators

The capability of liquid scintillator (namely 2'' Multiplication-Sign 2'' cells of EJ301 and EJ309) of detecting neutrons in a very high gamma ray background is explored. A weak {sup 252}Cf source has been detected in a high {sup 137}Cs gamma ray background corresponding to a dose rate of 100 {mu}Sv/h with probability of detection in compliance with IEC requirements for hand held instruments. Tests were performed with new generation of CAEN digitizers, in particular the V1720 (8 Channel 12bit 250 MS/s) one.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Neutron Detection Efficiency in He-3 Proportional Counters and Liquid Scintillators

We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.

Organic scintillator, He-3, neutron detection, det↗

Optimization of lithium-glass fibers with lithium depleted coating for neutron detection

Neutron-detecting scintillating glass uses 6 Li to capture thermal neutrons to produce an a and triton particle, which have $a$ range of 6 $µm$ and 36 $µm$, respectively. Captures on the surface of the glass can cause one of the particles to not deposit their energy in the glass causing the neutron to not be detected. This effect can be mitigated in lithium glass scintillators by coating lithium- glass fibers with lithium depleted scintillating glass. Thus, the scintillator’s efficiency will be increased. Results from this work show that a 20-60% increase in neutron efficiency depending on core size can be achieved with scintillating glass coatings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic and neutron detection properties of rare earth and titanium doped LiAlO 2 single crystals

In this study, LiAlO2 crystals doped with rare-earth elements and Ti were produced by the CZ method and spectroscopic and neutron detection properties were investigated. Photoluminescence revealed no clear luminescent activation of LiAlO2 by the rare-earth dopants though some interesting luminescence was observed from secondary phases within the crystal. Gamma-ray pulse height spectra collected using a 137Cs source exhibited only a Compton edge for the crystals. Neutron modeling using Monte Carlo N-Particle Transport Code revealed most neutrons used in the detection setup are thermalized, and while using natural lithium in the crystal growth, which contains 7.6 % 6Li, a 10 mm Ø by 10 mm sample of LiAlO2 has a 70.7 % intrinsic thermal neutron capture efficiency. Furthermore, the pulse height spectra collected using a 241Am-Be neutron source demonstrated a distinct neutron peak.

Dickens, Peter T.↗

Method for manufacturing solid-state thermal neutron detectors with simultaneous high thermal neutron detection efficiency (>50%) and neutron to gamma discrimination (>1.0E4)

Methods for manufacturing solid-state thermal neutron detectors with simultaneous high thermal neutron detection efficiency (>50%) and neutron to gamma discrimination (>10.sup.4) are provided. A structure is provided that includes a p+ region on a first side of an intrinsic region and an n+ region on a second side of the intrinsic region. The thickness of the intrinsic region is minimized to achieve a desired gamma discrimination factor of at least 1.0E+04. Material is removed from one of the p+ region or the n+ region and into the intrinsic layer to produce pillars with open space between each pillar. The open space is filed with a neutron sensitive material. An electrode is placed in contact with the pillars and another electrode is placed in contact with the side that is opposite of the intrinsic layer with respect to the first electrode.

36 MATERIALS SCIENCE↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

Lithium-containing chalcophosphates for thermal neutron detection

Inorganic compounds having the formula LiMP 2 Q 6 , where M is Ga, In, Bi, Sb, As, Al, or a combination thereof, and Q is S and/or Se, are provided. Methods and devices for detecting incident neutrons and alpha-particles using the compounds are also provided. For thermal neutron detection applications, the compounds can be enriched with lithium-6 isotope ( 6 Li) to enhance their neutron detecting capabilities.

Kanatzidis, Mercouri G.↗

Relative light yield and temporal response of a stilbene-doped bibenzyl organic scintillator for neutron detection

The neutron time-of-flight (nTOF) diagnostics used to characterize implosions at the National Ignition Facility (NIF) has necessitated the development of novel scintillators that exhibit a rapid temporal response and high light yield. One such material, a bibenzyl-stilbene mixed single-crystal organic scintillator grown in a 99.5:0.5 ratio in solution, has become the standard scintillator used for nTOF diagnostics at NIF. The prompt fluorescence lifetime and relative light yield as a function of proton energy were determined to calibrate this material as a neutron detector. The temporal evolution of the intensity of the prompt fluorescent response was modeled using first-order reaction kinetics and the prompt fluorescence decay constant was determined to be 2.46 ± 0.01 (fit) ± 0.13 (systematic) ns. The relative response of the bibenzyl-stilbene mixed crystal generated by recoiling protons was measured, and results were analyzed using Birks' relation to quantify the non-radiative quenching of excitation energy in the scintillator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Boron carbide coatings for neutron detection probed by x-rays, ions, and neutrons to determine thin film quality

Due to the present shortage of {sup 3}He and the associated tremendous increase of its price, the supply of large neutron detection systems with {sup 3}He becomes unaffordable. Alternative neutron detection concepts, therefore, have been invented based on solid {sup 10}B converters. These concepts require development in thin film deposition technique regarding high adhesion, thickness uniformity and chemical purity of the converter coating on large area substrates. We report on the sputter deposition of highly uniform large-area {sup 10}B{sub 4}C coatings of up to 2 μm thickness with a thickness deviation below 4% using the Helmholtz-Zentrum Geesthacht large area sputtering system. The {sup 10}B{sub 4}C coatings are x-ray amorphous and highly adhesive to the substrate. Material analysis by means of X-ray-Photoelectron Spectroscopy, Secondary-Ion-Mass-Spectrometry, and Rutherford-Back-Scattering (RBS) revealed low impurities concentration in the coatings. The isotope composition determined by Secondary-Ion-Mass-Spectrometry, RBS, and inelastic nuclear reaction analysis of the converter coatings evidences almost identical {sup 10}B isotope contents in the sputter target and in the deposited coating. Neutron conversion and detection test measurements with variable irradiation geometry of the converter coating demonstrate an average relative quantum efficiency ranging from 65% to 90% for cold neutrons as compared to a black {sup 3}He-monitor. Thus, these converter coatings contribute to the development of {sup 3}He-free prototype detectors based on neutron grazing incidence. Transferring the developed coating process to an industrial scale sputtering system can make alternative {sup 3}He-free converter elements available for large area neutron detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Detection with Large Plastic Scintillators for RPM Applications

Homeland security requests the use Radiation Portal Monitor (RPM). They must be able to detect and differentiate gamma and neutron radiation. Gamma detection is required for illicit transportation of radioactive matter detection. Neutron detection is important to control nonproliferation of enriched material. Manufacturers worldwide propose sensors based on {sup 3}He which give the actual state of art in term of neutron detection. The imminent shortage of {sup 3}He forces manufacturers to find viable alternative. From 10 years sensors providers have the challenge to replace previous {sup 3}He detectors that are known to be the most commonly deployed neutron sensor. As {sup 3}He detectors can only detect neutron, they must be completed with gamma detector. The proposed approach is based on pulse time correlation between adjacent sensors from signal collected by EJ200 plastic scintillators. Results obtained during FP7 Scintilla project test campaigns show the system relevance for replacement of today's {sup 3}He detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of current neutron detection systems for emergency response

Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3 He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10 B), lithium-6 ( 6 Li), and gadollinium-157 ( 157 Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4 He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Multiplicity Counting Moments for Fissile Mass Estimation in Scatter-Based Neutron Detection Systems

Neutron multiplicity counting (NMC) techniques are widely used for nuclear materials accountability and international safeguards applications to quantitatively evaluate characteristic properties pertaining to fissile material. Mathematical models for NMC moments have been previously derived for systems that use capture-based detectors; however, these models are not applicable when scatter-based detectors are used because of “neutron cross talk.” Neutron cross talk occurs when a single neutron scatters and deposits energy above threshold into multiple detectors causing spurious increase in multiplicity counts; this, in turn, has caused fissile mass to be overestimated when not treated. In this paper, we propose new mathematical models derived from point kinetics to correct for neutron cross-talk effects up to any arbitrary order N, where N denotes the maximum number of counts a single neutron can cause. The new models were used to estimate the fissile mass of plutonium metal and oxide samples with effective 240 Pu mass ranging from 2.5 to 250 g. The adequacy of the models was confirmed using simulations of a conceptual scatter-based neutron multiplicity counter (e.g., organic scintillators) using MCNPX v2.7e with the PoliMi fission event generating extension. The fissile mass estimates with no correction for neutron cross-talk events yielded an average relative deviation from the true 240 Pu eff mass of 55.94% and 84.56% for metal and oxide samples, respectively. When neutron cross-talk events of order N = 2 are included in the model, the fissile mass estimates yielded an average relative deviation of 11.89% for metal and 13.21% for oxide samples. Accounting for neutron cross-talk events of order N = 3 resulted in fissile mass estimates with an average relative deviation of 9.58% and 10.51% for metal and oxide samples, respectively. These mass estimates were compared to a reference case (i.e., no neutron crosstalk effects) that yielded an average relative deviation of 6.81% and 4.77% for metal and oxide samples, respectively. In conclusion, the discrepancy between the estimates from the proposed model and the reference case is attributed to the assumed value of N, which sets a finite upper bound on the order of cross-talk events the model treats (i.e., the model for N = 3 assumes that a neutron will never cause more than three counts).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detection

A neutron detector includes a microchannel plate having a structure that defines a plurality of microchannels, and layers of materials disposed on walls of the microchannels. The layers include a layer of neutron sensitive material, a layer of semiconducting material, and a layer of electron emissive material. For example, the layer of neutron sensitive material can include at least one of hafnium (Hf), samarium (Sm), erbium (Er), neodymium (Nd), tantalum (Ta), lutetium (Lu), europium (Eu), dysposium (Dy), or thulium (Tm).

Feller, W. Bruce↗