Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Neuromuscular dynamic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Role of Musculoskeletal Dynamics and Neuromuscular Control in Stress Development in Bone

The role of forces produced by the musculotendon units in the stress development of the long bones during gait has not been fully analyzed. It is well known that the musculotendons act as actuators producing the joint torques which drive the body. Although the joint torques required to perform certain motor tasks can be recovered through a kinematic analysis, it remains a difficult problem to determine the actual forces produced by each muscle that resulted in these torques. As a consequence, few studies have focused on the role of individual muscles in the development of stress in the bone. This study takes a control theoretic approach to the problem. A seven-link, eight degrees of freedom model of the body is controlled by various muscle groups on each leg to simulate gait. The simulations incorporate Hill-type models of muscles with activation and contraction dynamics controlled through neural inputs. This direct approach allows one to know the exact muscle forces exerted by each musculotendon throughout the gait cycle as well the joint torques and reaction forces at the ankle and knee. Stress and strain computed by finite element analysis on skeletal members will be related to these derived loading conditions. Thus the role of musculoskeletal dynamics and neuromuscular control in the stress development of the tibia during gait can be analyzed.

DeWoody, Yssa

Investigation of limb-sidestick dynamic interaction with roll control

A fixed-base simulation has been carried out to investigate and quantify limb/manipulator dynamics and interactions between the neuromuscular subsystem, force sensing sidestick configuration, high-gain command augmentation, and command filtering, and also to investigate possible relationships between these interactions and the roll ratchet phenomenon. The data obtained support the suggestion that the roll ratchet phenomenon is a closed-loop pilot-vehicle system interaction in which the pilot's neuromuscular system dynamics play a central role. Ratchet tendencies are shown to be most severe on force sensing sidestick manipulators with small stick deflections.

Johnston, D. E.

Linking the Pilot Structural Model and Pilot Workload

Behavioral models are developed that closely reproduced pulsive control response of two pilots using markedly different control techniques while conducting a tracking task. An intriguing find was that the pilots appeared to: 1) produce a continuous, internally-generated stick signal that they integrated in time; 2) integrate the actual stick position; and 3) compare the two integrations to either issue or cease a pulse command. This suggests that the pilots utilized kinesthetic feedback in order to sense and integrate stick position, supporting the hypothesis that pilots can access and employ the proprioceptive inner feedback loop proposed by Hess's pilot Structural Model. A Pilot Cost Index was developed, whose elements include estimated workload, performance, and the degree to which the pilot employs kinesthetic feedback. Preliminary results suggest that a pilot's operating point (parameter values) may be based on control style and index minimization.

Pilot workload

Comparing Theoretically Scaled Biomechanical Models

BACKGROUND An investigation into incorporating space suit aspects required a 50th-percentile male model which was not part of the existing dataset of models. Previously, theoretical models for 5th-percentile female and 95th-percentile male were created utilizing a scaled test subject as close as possible to the target height and weight. Scaling factors were created by taking the height ratio and applying it uniformly to the model body segments, then fine tuning to ensure the theoretical model’s height is as expected. This study was initiated to examine the existing method of isometrically scaling in OpenSim [1,2] and to create alternative methods which do not rely on an existing subject being close in height and weight to the theoretical model of interest. Generating a theoretical biomechanical model provides additional abilities without the reliance on available OpenSim models or real subjects. Gained abilities include creating different percentile models and attaining representative anthropometry for any target height/weight, such as targeting specific crew populations or gaps within the current dataset. METHODS AND RESULTS This study includes 3 methods for generating the theoretical model; utilizing the modified unscaled OpenSim Full Body Rajagopal Model (FBRM) [3,4], a dataset of scaled OpenSim models, and existing scaling factors from Dumas et al. [5]. All methods use the Anthropometric Survey of US Army Personnel (ANSUR II) [6] as an input of necessary anthropometric measurements. The following measurements are retrieved from the ANSUR II collection: mass, stature, cervicale height, acromial height, axilla height, waist height, trochanterion height, lateral femoral epicondyle height, lateral malleolus height, acromion-radiale length, radiale-stylion length, palm length, ball of foot length, bicristal breadth, bimalleolar breadth. Some of the measurements are direct segment lengths and others are utilized to derive segment lengths. Height, weight, and age ranges are the required inputs to parse the collection for a mean value of the measurements. A simple iterative process may be necessary for the output of mean mass and stature consistent with the theoretical model of interest. In some cases, one may specify exact values instead of a range but that is dependent upon whether those exact values pertain to a single subject from the ANSUR II collection. Equations from Dumas et al. were used to calculate scaling factors for the two methods that utilize OpenSim scaled and unscaled models. In the third method, Dumas’ scaling factors were used directly instead of generating our own. After scaling factors are achieved, they are applied along with the mass and segment lengths retrieved from ANSUR II in order to calculate the segment mass, Center of Mass (CoM), mass Moment of Inertia (MoI), and the joint location in the parent frame. The theoretical models from the different methods were compared to the previous existing method of isometrically scaling in OpenSim, as well as the standards found in NASA STD-3000 [7] and the NASA Human Integration Design Handbook [8]. The whole-body center of mass is the main comparison performed between the models and the standards. The body segment mass properties were also compared when possible. In some cases, the standards do not provide complete data, or the center of mass location is not provided with respect to the appropriate joint coordinate system. For a 50th-percentile male subject, results from isometric scaling in OpenSim and the method utilizing the unscaled FBRM were compared to the standards in NASA STD-3000. According to the standard, the whole-body vertical CoM location was taken from the head vertex to the CoM. The standards provide 80.2 cm for the CoM vertical component whereas isometric scaling in OpenSim and utilizing the unscaled FBRM provide 82.2 and 82.3 cm, respectively. Through definition, the whole-body CoM in the medial/lateral direction agreed across the models. Investigation is on-going to clearly identify the reference point pertaining to dorsal/ventral whole-body CoM position in standards and relate that to the theoretical models. REFERENCES [1] Delp, S.L., et al., “OpenSim: Open-source Software to Create and Analyze Dynamic Simulations of Movement”, IEEE Transactions on Biomedical Engineering, (2007). [2] Seth, A., Hicks J.L., Uchida, T.K., Habib, A., Dembia, C.L., Dunne, J.J., Ong, C.F., DeMers, M.S., Rajagopal, A., Millard, M., Hamner, S.R., Arnold, E.M., Yong, J.R., Lakshmikanth, S.K., Sherman,n M.A., Delp, S.L. OpenSim: Simulating musculoskeletal dynamics and neuromuscular control to study human and animal movement. Plos Computational Biology, 14(7). (2018) [3] R. K. Huffman, W. K. Thompson, C. A. Gallo, L. J. Quiocho, “Improvement of Scaling and Inverse Kinematic Results with Additional Upper Body Joints Added to Opensim Rajagopal Model”, NASA Human Research Program Investigator’s Workshop, (2019). [4] Huffman R.K., Thompson W., Gallo C., “Modified OpenSim Rajagopal Full Body Model”, New Technology Report, MSC-26872-1. (August 2020). [5] Dumas R., Cheze L. and Verriest J., 2007. “Adjustments to McConville et al. and Young et al. body segment inertial parameters”. Journal of Biomechanics 40, pp. 543-553 [6] Gordon C.C., 2012 “Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics”, US Army Natick Soldier RD&E Center. [7] NASA STD-3000/REV-B, 1995. “The Man-System Integration Standards” [8] NASA/SP-2010-3407/REV-1, 2014. “The Human Integration Design Handbook (HIDH)”

F N Matari

Neurological applications of man-machine systems analysis

Quantitative descriptions of human control properties are formulated that take into account the dynamics of muscle actuation units, neuromuscular sensor units, and sensory feedback mechanics. Detailed dynamic measurements on neurologically disordered patients are correlated with clinical manifestations of various neurological syndromes to quantify operator behavior.

Mcruer, D. T.

Modeling and measuring limb fine-motor unsteadiness

Fine-motor unsteadiness its properties, conceptual and analytical models, and experimental measurements is examined. Based on a data review, the tentative model derived includes: neuromuscular system, grip interface, and control system dynamic elements. The properties of this model change with muscle tension and match a wide group of extant data. A simple experiment was performed to investigate the amplitude/force relationships of the tremor mode. As the finger-pull force increased from 5 to 20 Newtons, the tremor mode frequency for a given individual stayed within roughly + or - 1 Hz over a range from 9-12 Hz, while the average magnitude of the rms tremor acceleration increased tenfold. A standardized test for making such measurements is given and applications in the fields of psychophysiological stress and strain measurements are mentioned.

Magdaleno, R. E.

Dual Extended Kalman Filter for the Identification of Time-Varying Human Manual Control Behavior

A Dual Extended Kalman Filter was implemented for the identification of time-varying human manual control behavior. Two filters that run concurrently were used, a state filter that estimates the equalization dynamics, and a parameter filter that estimates the neuromuscular parameters and time delay. Time-varying parameters were modeled as a random walk. The filter successfully estimated time-varying human control behavior in both simulated and experimental data. Simple guidelines are proposed for the tuning of the process and measurement covariance matrices and the initial parameter estimates. The tuning was performed on simulation data, and when applied on experimental data, only an increase in measurement process noise power was required in order for the filter to converge and estimate all parameters. A sensitivity analysis to initial parameter estimates showed that the filter is more sensitive to poor initial choices of neuromuscular parameters than equalization parameters, and bad choices for initial parameters can result in divergence, slow convergence, or parameter estimates that do not have a real physical interpretation. The promising results when applied to experimental data, together with its simple tuning and low dimension of the state-space, make the use of the Dual Extended Kalman Filter a viable option for identifying time-varying human control parameters in manual tracking tasks, which could be used in real-time human state monitoring and adaptive human-vehicle haptic interfaces.

manual control

Effect of manipulator and feel system characteristics on pilot performance in roll tracking

The control system features of force vs displacement stick command, feel/force displacement gradient, 'feel' system vs command prefilter dynamic lag, and flight control system effective time delay, have been investigated by a fixed-base simulation employing both joysticks and side-sticks in order to ascertain their effect on pilot opinion, pilot performance, and their hand/arm neuromuscular subsystem interaction. The results obtained indicate that the use of displacement sensing added the feel system dynamic lag to the command path and increased effective system flight delay, thereby lowering pilot opinion and performance but reducing the possibility of roll instability; the use of force sensing as stick command to exclude feel system dynamic lag had the obverse effect.

Aponso, Bimal L.

Investigation of limb-sidestick dynamic interaction with roll control

A fixed-base simulation was performed to identify and quantify interactions between the pilot's hand/arm neuromuscular subsystem and such features of typical modern fighter aircraft roll rate command control system mechanization as: (1) force sensing side-stick type manipulator; (2) vehicle effective roll time constant; and (3) flight control system effective time delay. The simulation results provide insight to high frequency pilot induced oscillations (PIO) (roll ratchet), low frequency PIO, and roll-to-right control and handling problems previously observed in experimental and production fly-by-wire control systems. The simulation configurations encompass and/or duplicate several actual flight situations, reproduce control problems observed in flight, and validate the concept that the high frequency nuisance mode known as roll ratchet derives primarily from the pilot's neuromuscular subsystem. The simulations show that force-sensing side-stick manipulator force/displacement/command gradients, command prefilters, and flight control system time delays need to be carefully adjusted to minimize neuromuscular mode amplitude peaking (roll ratchet tendency) without restricting roll control bandwidth (with resulting sluggish or PIO prone control).

Johnston, D. E.

The Influence of Robotic Assistance on Reducing Neuromuscular Effort and Fatigue during Extravehicular Activity Glove Use

The three-layered, pressurized space suit glove worn by Extravehicular Activity (EVA) crew members during missions commonly causes hand and forearm fatigue. The Spacesuit RoboGlove (SSRG), a Phase VI EVA space suit glove modified with robotic grasp-assist capabilities, has been developed to augment grip strength in order to improve endurance and reduce the risk of injury in astronauts. The overall goals of this study were to i) quantify the neuromuscular modulations that occur in response to wearing a conventional Phase VI space suit glove (SSG) during a fatiguing task, and ii) determine the efficacy of Spacesuit RoboGlove (SSRG) in reversing the adverse neuromuscular modulations and restoring altered muscular activity to barehanded levels. Six subjects performed a fatigue sequence consisting of repetitive dynamic-gripping interspersed with isometric grip-holds under three conditions: barehanded, wearing pressurized SSG, and wearing pressurized SSRG. Surface electromyography (sEMG) from six forearm muscles (flexor digitorum superficialis (FDS), flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), extensor digitorum (ED), extensor carpi radialis longus (ECRL), and extensor carpi ulnaris (ECU)) and subjective fatigue ratings were collected during each condition. Trends in amplitude and spectral distributions of the sEMG signals were used to derive metrics quantifying neuromuscular effort and fatigue that were compared across the glove conditions. Results showed that by augmenting finger flexion, the SSRG successfully reduced the neuromuscular effort needed to close the fingers of the space suit glove in more than half of subjects during two types of tasks. However, the SSRG required more neuromuscular effort to extend the fingers compared to a conventional SSG in many subjects. Psychologically, the SSRG aided subjects in feeling less fatigued during short periods of intense work compared to the SSG. The results of this study reveal the promise of the SSRG as a grasp-assist device that can improve astronaut performance and reduce the risk of injury by offsetting neuromuscular effort. Modifications to the experimental protocol are needed, however, to improve the outcome of the neuromuscular fatigue metrics and determine the effectiveness of SSRG in increasing astronaut endurance. Nevertheless, these findings will improve the understanding of astronaut-spacesuit interaction and provide direction toward designing improved spacesuit gloves and robotic-assist devices, like the SSRG.

Madden, Kaci E.

Correspondence between discrete and continuous models of excitable media: trigger waves

We present a theoretical framework for relating continuous partial differential equation (PDE) models of excitable media to discrete cellular automata (CA) models on a randomized lattice. These relations establish a quantitative link between the CA model and the specific physical system under study. We derive expressions for the CA model's plane wave speed, critical curvature, and effective diffusion constant in terms of the model's internal parameters (the interaction radius, excitation threshold, and time step). We then equate these expressions to the corresponding quantities obtained from solution of the PDEs (for a fixed excitability). This yields a set of coupled equations with a unique solution for the required CA parameter values. Here we restrict our analysis to "trigger" wave solutions obtained in the limiting case of a two-dimensional excitable medium with no recovery processes. We tested the correspondence between our CA model and two PDE models (the FitzHugh-Nagumo medium and a medium with a "sawtooth" nonlinear reaction source) and found good agreement with the numerical solutions of the PDEs. Our results suggest that the behavior of trigger waves is actually controlled by a small number of parameters.

Non-NASA Center

Investigation of interactions between limb-manipulator dynamics and effective vehicle roll control characteristics

A fixed-base simulation was performed to identify and quantify interactions between the pilot's hand/arm neuromuscular subsystem and such features of typical modern fighter aircraft roll rate command control system mechanization as: (1) force sensing side-stick type manipulator; (2) vehicle effective role time constant; and (3) flight control system effective time delay. The simulation results provide insight to high frequency pilot induced oscillations (PIO) (roll ratchet), low frequency PIO, and roll-to-right control and handling problems previously observed in experimental and production fly-by-wire control systems. The simulation configurations encompass and/or duplicate actual flight situations, reproduce control problems observed in flight, and validate the concept that the high frequency nuisance mode known as roll ratchet derives primarily from the pilot's neuromuscular subsystem. The simulations show that force-sensing side-stick manipulator force/displacement/command gradients, command prefilters, and flight control system time delays need to be carefully adjusted to minimize neuromuscular mode amplitude peaking (roll ratchet tendency) without restricting roll control bandwidth (with resulting sluggish or PIO prone control).

Johnston, D. E.

The Functional Task Test (FTT): An Interdisciplinary Testing Protocol to Investigate the Factors Underlying Changes in Astronaut Functional Performance

Exposure to space flight causes adaptations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. To achieve this goal we developed an interdisciplinary testing protocol (Functional Task Test, FTT) that evaluates both astronaut functional performance and related physiological changes. Functional tests include ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall and object translation tasks. Physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper- and lower-body muscle strength, power, endurance, control, and neuromuscular drive. Crewmembers perform this integrated test protocol before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on two sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Preliminary results from both Shuttle and ISS crewmembers indicate decrement in performance of the functional tasks after both short and long-duration space flight. On-going data collection continues to improve the statistical power required to map changes in functional task performance to alterations in physiological systems. The information obtained from this study will be used to design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

Bloomberg, J. J.

Theoretical linear approach to the combined man-manipulator system in manual control of an aircraft

An approach to the calculation of the dynamic characteristics of the combined man manipulator system in manual aircraft control was derived from a model of the neuromuscular system. This model combines the neuromuscular properties of man with the physical properties of the manipulator system which is introduced as pilot manipulator model into the manual aircraft control. The assumption of man as a quasilinear and time invariant control operator adapted to operating states, depending on the flight phases, of the control system gives rise to interesting solutions of the frequency domain transfer functions of both the man manipulator system and the closed loop pilot aircraft control system. It is shown that it is necessary to introduce the complete precision pilot manipulator model into the closed loop pilot aircraft transfer function in order to understand the well known handling quality criteria, and to derive these criteria directly from human operator properties.

Brauser, K.

A Transfer of Training Study of Control Loader Dynamics

The control inceptor used in a simulated vehicle is an important part in maintaining the fidelity of a simulation. The force feedback provided by the control inceptor gives the operator important cues to maintain adequate performance. The dynamics of a control inceptor are typically based on a second order spring mass damper system with damping, force gradient, breakout force, and natural frequency parameters. Changing these parameters can have a great effect on pilot or driver control of the vehicle. The neuromuscular system has a very important role in manipulating the control inceptor within a vehicle. Many studies by McRuer, Aponso, and Hess have dealt with modeling the neuromuscular system and quantifying the effects of a high fidelity control loader as compared to a low fidelity control loader. Humans are adaptive in nature and their control behavior changes based on different control loader dynamics. Humans will change their control behavior to maintain tracking bandwidth and minimize tracking error. This paper reports on a quasi-transfer of training experiment which was performed at the NASA Langley Research Center. The quasi transfer of training study used a high fidelity control loader and a low fidelity control loader. Subjects trained in both simulations and then were transferred to the high fidelity control loader simulation. The parameters for the high fidelity control loader were determined from the literature. The low fidelity control loader parameters were found through testing of a simple computer joystick. A disturbance compensatory task is employed. The compensatory task involves implementing a simple horizon out the window display. A disturbance consisting of a sum of sines is used. The task consists of the subject compensating for the disturbance on the roll angle of the aircraft. The vehicle dynamics are represented as 1/s and 1/s2. The subject will try to maintain level flight throughout the experiment. The subjects consist of non-pilots to remove any effects of pilot experience. First, this paper discusses the implementation of the disturbance compensation task. Second, the high and low fidelity parameters used within the experiment are presented. Finally, an explanation of results from the experiments is presented.

Cardullo, Frank M.